Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DATA CORRELATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Internal respiratory surrogate in multislice 4D CT using a combination of Fourier transform and anatomical features

Purpose: The purpose of this study was to develop a novel algorithm to create a robust internal respiratory signal (IRS) for retrospective sorting of four-dimensional (4D) computed tomography (CT) images. Methods: The proposed algorithm combines information from the Fourier transform of the CT images and from internal anatomical features to form the IRS. The algorithm first extracts potential respiratory signals from low-frequency components in the Fourier space and selected anatomical features in the image space. A clustering algorithm then constructs groups of potential respiratory signals with similar temporal oscillation patterns. The clustered group with the largest number of similar signals is chosen to form the final IRS. To evaluate the performance of the proposed algorithm, the IRS was computed and compared with the external respiratory signal from the real-time position management (RPM) system on 80 patients. Results: In 72 (90%) of the 4D CT data sets tested, the IRS computed by the authors’ proposed algorithm matched with the RPM signal based on their normalized cross correlation. For these data sets with matching respiratory signals, the average difference between the end inspiration times (Δt{sub ins}) in the IRS and RPM signal was 0.11 s, and only 2.1% of Δt{sub ins} were more than 0.5 s apart. In the eight (10%) 4D CT data sets in which the IRS and the RPM signal did not match, the average Δt{sub ins} was 0.73 s in the nonmatching couch positions, and 35.4% of them had a Δt{sub ins} greater than 0.5 s. At couch positions in which IRS did not match the RPM signal, a correlation-based metric indicated poorer matching of neighboring couch positions in the RPM-sorted images. This implied that, when IRS did not match the RPM signal, the images sorted using the IRS showed fewer artifacts than the clinical images sorted using the RPM signal. Conclusions: The authors’ proposed algorithm can generate robust IRSs that can be used for retrospective sorting of 4D CT data. The algorithm is completely automatic and requires very little processing time. The algorithm is cost efficient and can be easily adopted for everyday clinical use.

60 APPLIED LIFE SCIENCES↗

Radioisotope Identification with List-Mode Gamma Ray Data: A rigorous assessment on the value of temporal information applied to radioisotope identification.

This work explores the potential of utilizing temporal data from gamma-ray detectors, known as list-mode data, to enhance radioisotope identification. Traditional identification methods, which rely on full gamma-ray spectrum analysis, often require long dwell times and struggle with “confuser” sources, or spectra with similarly spaced spectral peaks. We hypothesize that by leveraging the probabilistic nature of nuclear decay and the time-encoded information from decay sequences and interactions with surrounding materials, we can improve classification accuracy over static spectral analysis. This research rigorously examines the temporal content of list-mode data through exploratory data analysis via correlation discovery and information theory. We further propose a basic classification model that can utilize spectral or temporal data (or both) to determine if the incorporation of temporal information can improve radioisotope identification. The findings suggest that the temporal information present in list-mode gamma-ray data has merit and should be further investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dataset_for_Conserved_macromolecular_architecture_of_Poplar_secondary_cell_walls_revealed_by_ssNMR_and_atomistic_modeling

This dataset contains solid-state 13C NMR data and atomistic molecular dynamics simulation files supporting the study of nanoscale secondary cell wall architecture across 13 genetically diverse Populus trichocarpa genotypes grown under uniform greenhouse conditions in 13C-enriched CO2 atmospheres (~89% 13C enrichment).The dataset contains two collections of solid-state 13C NMR data. (1) 200 MHz data (Bruker Avance III HD, 4 mm HX probe, 10 kHz MAS): raw Bruker TopSpin experiment folders and DMFIT-exported ascii spectra for selective and non-selective 1D 13C-13C spin diffusion experiments (3000 ms mixing) used to quantify inter-polymer spatial proximities, and short-mixing (1 ms) reference spectra used for polymeric abundance quantification by spectral deconvolution. (2) 600 MHz data (Bruker Avance III, 1.6 mm PhoenixNMR HXY probe, 30 kHz MAS): raw Bruker TopSpin experiment folders containing 2D CORD, 2D CP-INADEQUATE, and 13C/1H relaxation (T1, T1rho) experiments for all 13 genotypes, with processed Excel workbooks per experiment type. Molecular dynamics simulation code, coordinate files, and analysis scripts (NAMD/CHARMM/Python) for six atomistic cell wall models are included. Summarized ssNMR data are compiled into a single excel file and subjected to statistical analysis. Multivariate analysis code (PCA, Pearson correlation) and summary data are provided as excel worksheets and Jupyter notebooks (Python 3).

09 BIOMASS FUELS↗

Environmental parameters of the Tennessee River in Alabama. 2: Physical, chemical, and biological parameters

Physical, chemical and biological water quality data from five sites in the Tennessee River, two in Guntersville Reservoir and three in Wheeler Reservoir were correlated with climatological data for three annual cycles. Two of the annual cycles are for the years prior to the Browns Ferry Nuclear Power Plant operations and one is for the first 14 months of Plant operations. A comparison of the results of the annual cycles indicates that two distinct physical conditions in the reservoirs occur, one during the warm months when the reservoirs are at capacity and one during the colder winter months when the reservoirs have been drawn-down for water storage during the rainy months and for weed control. The wide variations of physical and chemical parameters to which the biological organisms are subjected on an annual basis control the biological organisms and their population levels. A comparison of the parameters of the site below the Power plant indicates that the heated effluent from the plant operating with two of the three reactors has not had any effect on the organisms at this site. Recommendations given include the development of prediction mathematical models (statistical analysis) for the physical and chemical parameters under specific climatological conditions which affect biological organisms. Tabulated data of chemical analysis of water and organism populations studied is given.

Rosing, L. M.↗

Seismicity and the subduction process

There is considerable variation between subduction zones in the largest characteristic earthquake within each zone. Assuming that coupling between downgoing and upper plates is directly related to characteristic earthquake size, tests for correlations between variation in coupling and other physical features of subduction zones are conducted: the lateral extent and penetration depth of Benioff zones, age of subducting lithosphere, convergence rate, and back-arc spreading. Using linear multivariate regression, coupling is correlated with two variables: convergence rate and lithosphere age. Secondary correlations within the data set are penetration depth versus lithosphere age, and lateral extent versus convergence rate. Taken together, the observed correlations suggest a simple qualitative model where convergence rate and lithosphere age determine the horizontal and sinking rates, respectively, of slabs: these parameters influence the seismic coupling in the subduction zone. In the limit of a fast sinking rate and slow convergence rate, back-arc spreading occurs and thereby appears to be a passive process.

Ruff, L.↗

Global pictures of the ozone field from high altitudes from DE-I

Detailed synoptic views of the column ozone field can be obtained by the Spin-Scan Ozone Imager (SOI) (Keating et al., 1981) aboard the Dynamics Explorer I satellite. The eccentric polar orbit with an apogee altitude of 23,000 km allows high resolution global-scale images to be obtained within 12 minutes, and allows regions to be viewed for long periods of time. At perigee, a pixel size of nadir measurements of 3 km is possible, and measurements are determined using the backscattered ultraviolet technique. A wavelength measurement of 317.5 nm is used as there are limitations in filter locations and it allows comparison with Nimbus 7 SBUV/TOMS data. Consideration of the reflectivities of this data aids in checking the SOI data reduction algorithm. SOI data show short-term (less than one day) variations in the observed ozone field, and a negative correlation (greater than 0.9) between ozone and tropopause heights. It is expected, due to this correlation, that SOI data will aid in understanding the time evolution of dynamics near the tropopause.

Keating, G. M.↗

TERRA Battery Thermal Control Anomaly - Simulation and Corrective Actions

The TERRA spacecraft was launched in December 1999 from Vandenberg Air Force Base, becoming the flagship of NASA's Earth Observing System program to gather data on how the planet's processes create climate. Originally planned as a 5 year mission, it still provides valuable science data after nearly 10 years on orbit. On October 13th, 2009 at 16:23z following a routine inclination maneuver, TERRA experienced a battery cell failure and a simultaneous failure of several battery heater control circuits used to maintain cell temperatures and gradients within the battery. With several cells nearing the minimum survival temperature, preventing the electrolyte from freezing was the first priority. After several reset attempts and power cycling of the control electronics failed to reestablish control authority on the primary side of the controller, it was switched to the redundant side, but anomalous performance again prevented full heater control of the battery cells. As the investigation into the cause of the anomaly and corrective action continued, a battery thermal model was developed to be used in determining the control ability remaining and to simulate and assess corrective actions. Although no thermal model or detailed reference data of the battery was available, sufficient information was found to allow a simplified model to be constructed, correlated against pre-anomaly telemetry, and used to simulate the thermal behavior at several points after the anomaly. It was then used to simulate subsequent corrective actions to assess their impact on cell temperatures. This paper describes the rapid development of this thermal model, including correlation to flight data before and after the anomaly., along with a comparative assessment of the analysis results used to interpret the telemetry to determine the extent of damage to the thermal control hardware, with near-term corrective actions and long-term operations plan to overcome the anomaly.

Grob, Eric W.↗

Partial scan artifact reduction (PSAR) for the assessment of cardiac perfusion in dynamic phase-correlated CT

Purpose: Cardiac CT achieves its high temporal resolution by lowering the scan range from 2{pi} to {pi} plus fan angle (partial scan). This, however, introduces CT-value variations, depending on the angular position of the {pi} range. These partial scan artifacts are of the order of a few HU and prevent the quantitative evaluation of perfusion measurements. The authors present the new algorithm partial scan artifact reduction (PSAR) that corrects a dynamic phase-correlated scan without a priori information. Methods: In general, a full scan does not suffer from partial scan artifacts since all projections in [0, 2{pi}] contribute to the data. To maintain the optimum temporal resolution and the phase correlation, PSAR creates an artificial full scan p{sub n}{sup AF} by projectionwise averaging a set of neighboring partial scans p{sub n}{sup P} from the same perfusion examination (typically N{approx_equal}30 phase-correlated partial scans distributed over 20 s and n=1,...,N). Corresponding to the angular range of each partial scan, the authors extract virtual partial scans p{sub n}{sup V} from the artificial full scan p{sub n}{sup AF}. A standard reconstruction yields the corresponding images f{sub n}{sup P}, f{sub n}{sup AF}, and f{sub n}{sup V}. Subtracting the virtual partial scan image f{sub n}{sup V} from the artificial full scan image f{sub n}{sup AF} yields an artifact image that can be used to correct the original partial scan image: f{sub n}{sup C}=f{sub n}{sup P}-f{sub n}{sup V}+f{sub n}{sup AF}, where f{sub n}{sup C} is the corrected image. Results: The authors evaluated the effects of scattered radiation on the partial scan artifacts using simulated and measured water phantoms and found a strong correlation. The PSAR algorithm has been validated with a simulated semianthropomorphic heart phantom and with measurements of a dynamic biological perfusion phantom. For the stationary phantoms, real full scans have been performed to provide theoretical reference values. The improvement in the root mean square errors between the full and the partial scans with respect to the errors between the full and the corrected scans is up to 54% for the simulations and 90% for the measurements. Conclusions: The phase-correlated data now appear accurate enough for a quantitative analysis of cardiac perfusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The parameter-level performance of covariance matrix conditioning in cosmic microwave background data analyses

Empirical estimates of the band power covariance matrix are commonly used in cosmic microwave background (CMB) power spectrum analyses. While this approach easily captures correlations in the data, noise in the resulting covariance estimate can systematically bias the parameter fitting. Conditioning the estimated covariance matrix, by applying prior information on the shape of the eigenvectors, can reduce these biases and ensure the recovery of robust parameter constraints. In this work, we use simulations to benchmark the performance of four different conditioning schemes, motivated by contemporary CMB analyses. The simulated surveys measure the TT, TE, and EE power spectra over the angular multipole range 300 ≤ ℓ ≤ 3500 in Δℓ = 50 wide bins, for temperature map-noise levels of 10, 6.4, and $2\, \mu$K arcmin. We divide the survey data into N real = 30, 50, or 100 uniform subsets. We show the results of different conditioning schemes on the errors in the covariance estimate, and how these uncertainties on the covariance matrix propagate to the best-fitting parameters and parameter uncertainties. The most significant effect we find is an additional scatter in the best-fitting point, beyond what is expected from the data likelihood. For a minimal conditioning strategy, N real = 30, and a temperature map-noise level of 10$\, \mu$K arcmin, we find the uncertainty on the recovered best-fitting parameter to be ×1.3 larger than the apparent posterior width from the likelihood (×1.2 larger than the uncertainty when the true covariance is used). Stronger priors on the covariance matrix reduce the misestimation of parameter uncertainties to $\lt 1{{\ \rm per\ cent}}$. As expected, empirical estimates perform better with higher N real , ameliorating the adverse effects on parameter constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

Space Shuttle Partial Stack Rollout Test Analytical Correlation In Support Of Fatigue Load Development

A rollout test with only the Solid Rocket Boosters was conducted in November 2003 to gather structural dynamic response data of the transportation environment from the Vehicle Assembly Building to the Launch Pad. The data was acquired to develop and validate analytical methods used to predict rollout Orbiter fatigue load spectra. Earlier predictions computed by a base drive approach with only 5 input drive degrees-of-freedom raised questions that commissioned the partial stack test. Not only was there a concern because of the input degree-of-freedom omission due to measurement limitations, but there was also a concern with the implementation of the "large mass" itself. Three methods were evaluated with the partial stack test data. The analytical correlations to measured strain derived SRB base loads and acceleration5 showed the earlier 5 degree-of-freedom base drive approach to yield the most conservative results for all quantities monitored except the SRB base moment about the axis in which the input drive was missing. This non-conservative shortcoming led to a recommendation to use either the 6 degree-of-freedom base drive or the 12 degree-of-freedom Craig-Bampton boundary drive methods whose results did not substantially differ.

DelBasso, Steve↗

Carbon monoxide measurements at Mace Head, Ireland

The North Atlantic Ocean is bordered by continents which may each, under the influence of seasonal weather patterns, act as sources of natural and anthropogenic trace gas and particulate species. Photochemically active species such as carbon monoxide (CO) react to form ozone (O3), a species of critical importance in global climate change. CO is sparingly soluble in water, and the relatively long lifetime of CO in the troposphere makes this species an ideal tracer of air masses with origin over land. We have measured CO using a nondispersive infrared gas filter correlation analyzer at Mace Head on the west coast of Ireland nearly continuously since August 9, 1991. Measurements of CO were acquired at 20-sec resolution and recorded as 60-sec averages. Daily, monthly, and diurnal variation data characteristics of CO mixing ratios observed at this site are reported. Depending on source regions of air parcels passing over this site, 60-min concentrations of CO range from clean air values of approximately 90 ppbv to values in excess of 300 ppbv. Data characterizing the correlation between 60-min CO and O3 mixing ratio data observed at this site are reported also.

Doddridge, Bruce G.↗

Herschel far-infrared photometry of the swift burst alert telescope active galactic nuclei sample of the local universe. I. PACS observations

Far-Infrared (FIR) photometry from the Photodetector Array Camera and Spectrometer on the Herschel Space Observatory is presented for 313 nearby, hard X-ray selected galaxies from the 58 month Swift Burst Alert Telescope (BAT) Active Galactic Nuclei catalog. The present data do not distinguish between the FIR luminosity distributions at 70 and 160 μm for Seyfert 1 and Seyfert 2 galaxies. This result suggests that if the FIR emission is from the nuclear obscuring material surrounding the accretion disk, then it emits isotropically, independent of orientation. Alternatively, a significant fraction of the 70 and 160 μm luminosity could be from star formation, independent of active galactic nucleus (AGN) type. Using a non-parametric test for partial correlation with censored data, we find a statistically significant correlation between the AGN intrinsic power (in the 14-195 keV band) and the FIR emission at 70 and 160 μm for Seyfert 1 galaxies. We find no correlation between the 14-195 keV and FIR luminosities in Seyfert 2 galaxies. The observed correlations suggest two possible scenarios: (1) if we assume that the FIR luminosity is a good tracer of star formation, then there is a connection between star formation and the AGN at sub-kiloparsec scales, or (2) dust heated by the AGN has a statistically significant contribution to the FIR emission. Using a Spearman rank-order analysis, the 14-195 keV luminosities for the Seyfert 1 and 2 galaxies are weakly statistically correlated with the F {sub 70}/F {sub 160} ratios.

79 ASTRONOMY AND ASTROPHYSICS↗

Freeboard, Snow Depth and Sea-Ice Roughness in East Antarctica from In Situ and Multiple Satellite Data

In October 2003 a campaign on board the Australian icebreaker Aurora Australis had the objective to validate standard Aqua Advanced Microwave Scanning Radiometer (AMSR-E) sea-ice products. Additionally, the satellite laser altimeter on the Ice, Cloud and land Elevation Satellite (ICESat) was in operation. To capture the large-scale information on the sea-ice conditions necessary for satellite validation, the measurement strategy was to obtain large-scale sea-ice statistics using extensive sea-ice measurements in a Lagrangian approach. A drifting buoy array, spanning initially 50 km 100 km, was surveyed during the campaign. In situ measurements consisted of 12 transects, 50 500 m, with detailed snow and ice measurements as well as random snow depth sampling of floes within the buoy array using helicopters. In order to increase the amount of coincident in situ and satellite data an approach has been developed to extrapolate measurements in time and in space. Assuming no change in snow depth and freeboard occurred during the period of the campaign on the floes surveyed, we use buoy ice-drift information as well as daily estimates of thin-ice fraction and rough-ice vs smooth-ice fractions from AMSR-E and QuikSCAT, respectively, to estimate kilometer-scale snow depth and freeboard for other days. The results show that ICESat freeboard estimates have a mean difference of 1.8 cm when compared with the in situ data and a correlation coefficient of 0.6. Furthermore, incorporating ICESat roughness information into the AMSR-E snow depth algorithm significantly improves snow depth retrievals. Snow depth retrievals using a combination of AMSR-E and ICESat data agree with in situ data with a mean difference of 2.3 cm and a correlation coefficient of 0.84 with a negligible bias.

Markus, Thorsten↗

Correlation of AH-1G helicopter flight vibration data and tailboom static test data with NASTRAN analytical results

Level flight airframe vibration at main rotor excitation frequencies was calculated. A NASTRAN tailboom analysis was compared with test data for evaluation of methods used to determine effective skin in a semimonocoque sheet-stringer structure. The flight vibration correlation involved comparison of level flight vibration for two helicopter configurations: clean wing, at light gross weight and wing stores at heavy gross weight. In the tailboom correlation, deflections and internal loads were compared using static test data and a NASTRAN analysis. An iterative procedure was used to determine the amount of effective skin of buckled panels under compression load.

Cronkhite, J. D.↗

Drug-Eluting Beads Loaded With Doxorubicin (DEBDOX) Chemoembolisation Before Liver Transplantation for Hepatocellular Carcinoma: An Imaging/Histologic Correlation Study

Purpose Most transplant centers use chemoembolisation as locoregional bridge therapy for hepatocellular carcinoma (HCC) before liver transplantation (LT). Chemoembolisation using beads loaded with doxorubicin (DEBDOX) is a promising technique that enables delivery of a large quantity of drugs against HCC. We sought to assess the imaging–histologic correlation after DEBDOX chemoembolisation.Materials and Methods All consecutive patients who had undergone DEBDOX chemoembolisation before receiving liver graft for HCC were included. Tumour response was evaluated according to Response Evaluation Criteria in Solid Tumours (RECIST) and modified RECIST (mRECIST) criteria. The result of final imaging made before LT was correlated with histological data to predict tumour necrosis.ResultsTwenty-eight patients underwent 43 DEBDOX procedures for 45 HCC. Therapy had a significant effect as shown by a decrease in the mean size of the largest nodule (p = 0.02) and the sum of viable part of tumour sizes according to mRECIST criteria (p < 0.001). An objective response using mRECIST criteria was significantly correlated with mean tumour necrosis ≥90 % (p = 0.03). A complete response using mRECIST criteria enabled accurate prediction of complete tumour necrosis (p = 0.01). Correlations using RECIST criteria were not significant.ConclusionOur data confirm the potential benefit of DEBDOX chemoembolisation as bridge therapy before LT, and they provide a rational basis for new studies focusing on recurrence-free survival after LT. Radiologic evaluation according to mRECIST criteria enables accurate prediction of tumour necrosis, whereas RECIST criteria do not.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cross-correlation search for periodic gravitational waves

In this paper we study the use of cross correlations between multiple gravitational wave (GW) data streams for detecting long-lived periodic signals. Cross-correlation searches between data from multiple detectors have traditionally been used to search for stochastic GW signals, but recently they have also been used in directed searches for periodic GWs. Here we further adapt the cross-correlation statistic for periodic GW searches by taking into account both the nonstationarity and the long-term-phase coherence of the signal. We study the statistical properties and sensitivity of this search and its relation to existing periodic wave searches, and describe the precise way in which the cross-correlation statistic interpolates between semicoherent and fully coherent methods. Depending on the maximum duration over which we wish to preserve phase coherence, the cross-correlation statistic can be tuned to go from a standard cross-correlation statistic using data from distinct detectors, to the semicoherent time-frequency methods with increasing coherent time baselines, and all the way to a full coherent search. This leads to a unified framework for studying periodic wave searches and can be used to make informed trade-offs between computational cost, sensitivity, and robustness against signal uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Natural innate cytokine response to immunomodulators and adjuvants in human precision-cut lung slices

Prediction of lung innate immune responses is critical for developing new drugs. Well-established immune modulators like lipopolysaccharides (LPS) can elicit a wide range of immunological effects. They are involved in acute lung diseases such as infections or chronic airway diseases such as COPD. LPS has a strong adjuvant activity, but its pyrogenicity has precluded therapeutic use. The bacterial lipopeptide MALP-2 and its synthetic derivative BPPcysMPEG are better tolerated. We have compared the effects of LPS and BPPcysMPEG on the innate immune response in human precision-cut lung slices. Cytokine responses were quantified by ELISA, Luminex, and Meso Scale Discovery technology. The initial response to LPS and BPPcysMPEG was marked by coordinated and significant release of the mediators IL-1{beta}, MIP-1{beta}, and IL-10 in viable PCLS. Stimulation of lung tissue with BPPcysMPEG, however, induced a differential response. While LPS upregulated IFN-{gamma}, BPPcysMPEG did not. This traces back to their signaling pathways via TLR4 and TLR2/6. The calculated exposure doses selected for LPS covered ranges occurring in clinical studies with human beings. Correlation of obtained data with data from human BAL fluid after segmental provocation with endotoxin showed highly comparable effects, resulting in a coefficient of correlation > 0.9. Furthermore, we were interested in modulating the response to LPS. Using dexamethasone as an immunosuppressive drug for anti-inflammatory therapy, we found a significant reduction of GM-CSF, IL-1{beta}, and IFN-{gamma}. The PCLS-model offers the unique opportunity to test the efficacy and toxicity of biological agents intended for use by inhalation in a complex setting in humans.

60 APPLIED LIFE SCIENCES↗

Multi-configuration Membrane Distillation Model (MCMD)

Many membrane distillation models have been created to simulate the heat and mass exchange process involved but most of the literature only validates models to a couple of cases with minor configuration changes. Tools are needed that allow tradeoffs between many configurations. The multiconfiguration membrane distillation model handles many configurations. This report introduces membrane distillation, provides theory, and presents the work to verify and validate the model against experimental data from Colorado School of Mines and a lower resolution model created at the National Renewable Energy Laboratory. Though more data analysis and testing are needed, an initial look at the model to experimental comparisons indicates that the model correlates to the data well but that design comparisons are likely to be incorrect across a broad range of configurations. More accurate quantification of heat and mass transfer through computational fluid mechanics is suggested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗