Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Celiac Trunk Embolization, as a Means of Elongating Short Distal Descending Thoracic Aortic Aneurysm Necks, Prior to Endovascular Aortic Repair

The purpose of this study was to report our experience in elongating short distal necks of descending thoracic aortic aneurysms (DTAAs) by coil embolization of the celiac trunk prior to endovascular aneurysm repair (EVAR). During 6 years seven patients (five men and two women; mean age, 74) who had DTAAs with short distal necks unsuitable for conventional EVAR, and well patent superior and inferior mesenteric arteries based on CT, were treated in one session with EVAR after the celiac trunk was coil embolized to elongate the neck. All patients were followed by CT every 3 months in the first year and every 6 months thereafter. Technical success was achieved in all patients, and no early or late ischemic complications were noted. No procedural complications occurred and good aneurysm sealing was obtained in all patients. Three endoleaks were identified after 3 months (one patient) and 6 months (two patients); all were treated successfully with insertion of an additional stent-graft. In patients with DTAAs who are candidates for EVAR but have short aneurysm distal necks, celiac trunk embolization-only if the superior and inferior mesenteric arteries are patent-is a good and safe way to elongate the neck and enable EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transsplenic Access to the Portal Vein for Management of Vascular Complication in Patients with Chronic Liver Disease

Purpose: To evaluate the safety and feasibility of percutaneous transsplenic access to the portal vein for management of vascular complication in patients with chronic liver diseases. Methods: Between Sept 2009 and April 2011, percutaneous transsplenic access to the portal vein was attempted in nine patients with chronic liver disease. Splenic vein puncture was performed under ultrasonographic guidance with a Chiba needle, followed by introduction of a 4 to 9F sheath. Four patients with hematemesis or hematochezia underwent variceal embolization. Another two patients underwent portosystemic shunt embolization in order to improve portal venous blood flow. Portal vein recanalization was attempted in three patients with a transplanted liver. The percutaneous transsplenic access site was closed using coils and glue. Results: Percutaneous transsplenic splenic vein catheterization was performed successfully in all patients. Gastric or jejunal varix embolization with glue and lipiodol mixture was performed successfully in four patients. In two patients with a massive portosystemic shunt, embolization of the shunting vessel with a vascular plug, microcoils, glue, and lipiodol mixture was achieved successfully. Portal vein recanalization was attempted in three patients with a transplanted liver; however, only one patient was treated successfully. Complete closure of the percutaneous transsplenic tract was achieved using coils and glue without bleeding complication in all patients. Conclusion: Percutaneous transsplenic access to the portal vein can be an alternative route for portography and further endovascular management in patients for whom conventional approaches are difficult or impossible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Amplatzer Vascular Plug: A Review of the Device and its Clinical Applications

The Amplatzer Vascular Plug (AVP) is an established embolic device that can be an excellent alternative to coils or detachable balloons to embolize medium to large vessels with high flow. The device is easy to use and can be precisely deployed in the target vessel with high resistance to migration and a low recanalization rate. The technical success of this device is high, indications for use are expanding, and no absolute contraindications have been reported. Since its introduction, the AVP has grown from a single device to a group of 4 models (AVP, AVP II, AVP III, and AVP 4). Each model has a unique design and features that fit different vascular anatomies, hemodynamic situations, and clinical scenarios. Therefore, the new models cannot simply be treated as replacements for older ones. Unpredictable occlusion time remains a major shortcoming for the new models of the AVP. Large vessel size, high flow status, and coagulopathy can prolong the occlusion time, which can offset the cost benefit, reduced procedure time, and reduced radiation dose typically seen with use of the AVP alone. Coils or multiple AVPs can be used to expedite the occlusion process, and large Gelfoam particles also can be used as an adjunct to achieve rapid and reliable occlusion with minimal cost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Irreversible Electroporation Adjacent to the Rectum: Evaluation of Pathological Effects in a Pig Model

To evaluate the effects of irreversible electroporation (IRE) on the rectum wall after IRE applied adjacent to the rectum. CT-guided IRE adjacent to the rectum wall was performed in 11 pigs; a total of 44 lesions were created. In five pigs, ablations were performed without a water-filled endorectal coil (group A); in six pigs, ablation was performed with the coil to avoid displacement of the rectum wall (group B). The pigs were killed after 7-15 days and the rectums were harvested for pathological evaluation. There was no evidence of perforation on gross postmortem examination. Perirectal muscle lesions were observed in 18 of 20 ablations in group A and in 21 of 24 ablations in group B. Inflammation and fibrosis of the muscularis propria was observed in ten of 18 lesions in group A and in ten of 21 lesions in group B. In group A, findings were limited to the external layer of the muscularis propria except for one lesion; in group B, findings were transmural in all cases. Transmural necrosis with marked suppurative mucosal inflammation was observed in seven of 21 lesions in group B and in no lesion in group A. IRE-ablation adjacent to the rectum may be uneventful if the rectum wall is mobile and able to contract. IRE-ablation of the rectum may be harmful if the rectum wall is fixed adjacent to the IRE-probe.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Pelvic Congestion Syndrome: Visual Analog Scale (VAS) Long-Term Follow-up Clinical Evaluation in 202 Patients

PurposeThis study was designed to evaluate the clinical outcome and patients' satisfaction after a 5 year follow-up period for pelvic congestion syndrome (PCS) coil embolization in patients who suffered from chronic pelvic pain that initially consulted for lower limb venous insufficiency.MethodsA total of 202 patients suffering from chronic pelvic pain were recruited prospectively in a single center (mean age 43.5 years; range 27-57) where they were being treated for lower limb varices. Inclusion criteria were: lower limb varices and chronic pelvic pain (>6 months), >6 mm pelvic venous caliber in ultrasonography, and venous reflux or presence of communicating veins. Both ovarian and hypogastric veins were targeted for embolization. Pain level was assessed before and after embolotherapy and during follow-up using a visual analog scale (VAS). Technical and clinical success and recurrence of leg varices were studied. Patients completed a quality questionnaire. Clinical follow-up was performed at 1, 3, and 6 months and every year for 5 years.ResultsTechnical success was 100 %. Clinical success was achieved in 168 patients (93.85 %), with complete disappearance of symptoms in 60 patients (33.52 %). Pain score (VAS) was 7.34 {+-} 0.7 preprocedural versus 0.78 {+-} 1.2 at the end of follow-up (P < 0.0001). Complications were: groin hematoma (n = 6), coil migration (n = 4), and reaction to contrast media (n = 1). Twenty-three cases presented abdominal pain after procedure. In 24 patients (12.5 %), there was recurrence of their leg varices within the follow-up. The mean degree of patients' satisfaction was 7.4/9.ConclusionsCoil embolization of PCS is an effective and safe procedure, with high clinical success rate and degree of satisfaction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of Ruptured Vertebral Artery Dissecting Aneurysms Distal to the Posterior Inferior Cerebellar Artery: Stenting or Trapping?

PurposeThe treatment of ruptured vertebral artery dissecting aneurysms (VADAs) continues to be controversial. Our goal was to evaluate the safety, efficacy, and long-term outcomes of internal trapping and stent-assisted coiling (SAC) for ruptured VADAs distal to the posterior inferior cerebellar artery (supra-PICA VADAs), which is the most common subset.MethodsA retrospective review was conducted of 39 consecutive ruptured supra-PICA VADAs treated with internal trapping (n = 20) or with SAC (n = 19) at our institution. The clinical and angiographic data were retrospectively compared.ResultsThe immediate total occlusion rate of the VADAs was 80 % in the trapping group, which improved to 88.9 % at the follow-ups (45 months on average). Unwanted occlusions of the posterior inferior cerebellar artery (PICA) were detected in three trapped cases. Incomplete obliteration of the VADA or unwanted occlusions of the PICA were detected primarily in the VADAs closest to the PICA. In the stenting group, the immediate total occlusion rate was 47.4 %, which improved to 100 % at the follow-ups (39 months on average). The immediate total occlusion rate of the VADAs was higher in the trapping group (p < 0.05), but the later total occlusion was slightly higher in the stenting group (p > 0.05).ConclusionsOur preliminary results showed that internal trapping and stent-assisted coiling are both technically feasible for treating ruptured supra-PICA VADAs. Although not statistically significant, procedural related complications occurred more frequently in the trapping group. When the VADAs are close to the PICA, we suggest that the lesions should be treated using SAC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role and Effectiveness of Percutaneous Arterial Embolization in Hemodynamically Unstable Patients with Ruptured Splanchnic Artery Pseudoaneurysms

PurposeTo assess the role and effectiveness of percutaneous arterial embolization (TAE) in patients with hemodynamic instability due to hypovolemic shock secondary to ruptured splanchnic artery pseudoaneurysms (SAPA).Materials and MethodsSeventeen patients (11 men, 6 women; mean age, 53 years) with hemodynamic instability (systolic blood pressure <90 mmHg) due to hypovolemic shock secondary to ruptured SAPA were treated by TAE. Clinical files, multidetector row computed tomography angiography, and angiographic examinations along with procedure details were reviewed.ResultsSeventeen SAPAs were present, predominantly located on gastroduodenal or pancreatic arteries (9/17; 53 %). Angiography showed extravasation of contrast medium from SAPA in 15/17 patients (88 %). Technical success rate of TAE was 100 %. TAE was performed using metallic coils in all patients (100 %), in association with gelatin sponge in 5/17 patients (29 %). TAE allowed controlling the bleeding and returning to normal hemodynamic status in 16/17 patients (94 %). In 1/17 patient (6 %), surgery was needed to definitively control the bleeding. The mortality and morbidity rate of TAE at 30 days were 0 and 12 %, respectively. Morbidity consisted in coil migration in 1/17 patient (6 %) and transient serum liver enzyme elevation in 1/17 patient (6 %).ConclusionTAE is an effective and safe treatment option for ruptured SAPA in hemodynamically unstable patients, with a success rate of 94 %. Our results suggest that TAE should be the favored option in patients with hemodynamic instability due to ruptured SAPA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emborrhoid: A New Concept for the Treatment of Hemorrhoids with Arterial Embolization: The First 14 Cases

PurposeThe ‘emborrhoid’ technique consists of the embolization of the hemorrhoidal arteries. The endovascular arterial occlusion is performed using coils placed in the terminal branches of the superior rectal arteries. The emborrhoid technique has been modeled after elective transanal Doppler-guided hemorrhoidal artery ligation which has been shown to be effective in hemorrhoidal disease. We report the first 14 cases of our experience with emborrhoid technique.Materials and MethodsFourteen patients with disabling chronic rectal bleeding were treated using the emborrhoid technique (3 women, 11 men). The stage of the hemorrhoidal disease was II (10 patients), III (3), and IV (1). This treatment was decided by a multidisciplinary team (proctologist, visceral surgeon, and radiologist). Seven patients underwent previous proctological surgery. Ten patients had coagulation disorders (anticoagulants or cirrhosis). Superior rectal arteries were embolized with pushable microcoils (0.018).ResultsTechnical success of the embolization procedure was 100 %. Clinical success at 1 month was 72 % (10/14). Of the 4 patients who experienced rebleeding, two underwent additional embolization of the posterior rectal arteries with success. No pain or ischemic complications were observed in 13 patients. One patient experienced a temporary painful and edematous, perianal reaction.ConclusionOur case studies suggest that coil embolization of the superior rectal arteries is technically feasible, safe and well tolerated. Additional studies are needed to evaluate the efficacy of this new ‘emborrhoid’ technique in the management of hemorrhoidal disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Embolisation of Proximal Type 1 Endoleaks Following Endovascular Aneurysm Sealing (EVAS) Using the Nellix Device: Technique and Outcomes

AimTo evaluate the technical success and mid-term outcomes following transcatheter embolisation of type 1a endoleak after Nellix endovascular aneurysm sealing (EVAS).Materials and MethodsSeven patients (5 men; mean age 83; range 79–90) underwent transcatheter embolisation between July 2013 and August 2014. The average time from EVAS to embolisation was 136 days (range 6–301) and from endoleak diagnosis to embolisation was 20 days (range 2–50). Embolisation was performed with coils and Onyx in six cases and Onyx only in one case. Technical success, imaging and clinical outcomes of embolisation were reviewed. Technical success was defined as elimination of the endoleak on completion angiography and first imaging follow-up. Clinical success was defined as unchanged or decreased aneurysm sac size on subsequent follow-up (average 8 months; range 103–471 days).ResultsAll cases were technically successful. One patient required a second endovascular procedure following Onyx reflux into the Nellix endograft and another patient required surgical closure of a brachial puncture site. All patients are endoleak free with stable sac size on the latest available follow-up imaging.ConclusionIf a type 1 endoleak occurs after EVAS, embolisation using Onyx with or without coils is feasible and effective with high technical success and freedom from endoleak recurrence at mid-term follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Splenic Arterial Embolization in the Treatment of Severe Portal Hypertension Due to Pancreatic Diseases: The Primary Experience in 14 Patients

ObjectiveThis retrospective study reports our experience using splenic arterial particle embolization and coil embolization for the treatment of sinistral portal hypertension (SPH) in patients with and without gastric bleeding.MethodsFrom August 2009 to May 2012, 14 patients with SPH due to pancreatic disease were diagnosed and treated with splenic arterial embolization. Two different embolization strategies were applied; either combined distal splenic bed particle embolization and proximal splenic artery coil embolization in the same procedure for acute hemorrhage (1-step) or interval staged distal embolization and proximal embolization in the stable patient (2-step). The patients were clinically followed.ResultsIn 14 patients, splenic arterial embolization was successful. The one-step method was performed in three patients suffering from massive gastric bleeding, and the bleeding was relieved after embolization. The two-step method was used in 11 patients, who had chronic gastric variceal bleeding or gastric varices only. The gastric varices disappeared in the enhanced CT scan and the patients had no gastric bleeding during follow-up.ConclusionsSplenic arterial embolization, particularly the two-step method, proved feasible and effective for the treatment of SPH patients with gastric varices or gastric variceal bleeding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Steerable Microcatheter: A New Device for Selective Catheterisation

The steerable microcatheter (SwiftNINJA, Sumitomo Bakelite, Tokyo, Japan), which has a remote-controlled flexible tip manipulated using a dial in the handgrip, was recently developed and delivered to the market. This device enables the user to change the angle of the microcatheter tip manually, and potentially makes selective catheterisation easier. We evaluated its unique characteristics and utility in selective catheterisation and coil embolization. This article describes: (1) the advantages of this device in catheterisations involving acute angle branches, and (2) a new technique of compact coil packing with the use of intentional folding by the bendable tip of the catheter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Ablation of the Marginal Venous System in Patients with Venous Malformations

Purpose: To evaluate radiofrequency ablation (RFA) for closure of marginal veins in pediatric and adult patients with venous malformations. Materials and methods: Medical records, imaging and procedure details were retrospectively reviewed in patients who underwent RFA of the marginal vein in a 17-month period. Additional sclerotherapy (n = 19) and coil embolization of the marginal vein were performed (n = 2). Results: A total of 23 marginal veins were treated in 20 patients. Mean age at treatment was 16 years ± 9.4 (1–37 years). Pre-procedural magnetic resonance imaging revealed thoracoabdominal marginal veins in 3 patients. A type I marginal vein (draining in the great saphenous vein below the popliteal vein) was identified in 1 and type IIa/IIb (draining in a median/lateral accessory saphenous vein) in 2/8 cases. Type III (draining into the profunda femoral vein) was detected in 8, and type IV (draining into gluteal veins) in 1. Mean diameter of the marginal veins was 13.2 mm ± 4 (7–20 mm). Patency was found in 1 during follow-up (22 months ± 9.8). Complete or partial occlusion was achieved in 94.5% of the veins. One patient showed signs of thrombophlebitis after the procedure, and another incomplete paresis of the peroneal nerve. Conclusion: RFA is effective as minimally invasive treatment of the marginal venous system. These veins should be treated early in life. Marginal veins with large diameter, residual tributaries and the intrafascial courses usually require adjunct coil embolization and sclerotherapy. Level of Evidence: Case series, Level IV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of Length of Virtual Stents in Treatment of Intracranial Wide-Necked Aneurysms

Background and Purpose: Precise stent deployment is important for successful treatment of intracranial aneurysms by stent-assisted coiling (SAC). We evaluated the accuracy of virtual stents generated using commercial stent planning software by comparing the length of virtual and actually deployed intracranial laser cut stents on three-dimensional digital subtraction angiography (3D-DSA) images. Methods: We retrospectively analyzed the data of 75 consecutive cases of intracranial wide-necked aneurysms treated with the SAC technique using laser cut stents. Based on 3D-DSA images acquired by C-arm CT, stent sizing and placement were intraoperatively simulated by a commercial software application. The difference in length of the stents was estimated by measuring proximal discrepancies between the end points of the virtual and actually deployed stents on fused pre-procedural and post-procedural 3D-DSA images. Discrepancies between distal stent end points were manually minimized. The Kruskal–Wallis test was applied to test whether stent location, type, and length had an effect on difference in length between virtual and real stent. Results: The median difference in length between virtual and real stents was 1.58 mm with interquartile range 1.12–2.12 mm. There was no evidence for an effect of stent location (p = 0.23), stent type (p = 0.33), or stent length (p = 0.53) on difference in length between virtual and real stents. Conclusions: Stent planning software allows 3D simulation of laser cut stents overlain on 3D-DSA images of vessels and may thus be useful for stent selection and deployment of laser cut stents during stent-assisted coiling of intracranial aneurysms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Eddy Current Probe Parameters Identification Using a Genetic Algorithm and Simultaneous Perturbation Stochastic Approximation

This study tries to identify the coil parameters using numerical methods. The eddy current testing (ECT) is used for evaluation of a crack with the aid of numerical simulations by utilizing the identification of these parameters. In this study, a comparison of the performance of the GA and SPSA algorithms to identify the parameter values of the coil sensors are presented. So, the optimization probe geometry is introduced in the simulation with Three-dimensional finite element simulations (FLUX finite element code) were conducted to obtain eddy current signals resulting from a crack in a plate made of aluminium. The simulation results are compared with experimental measurements for the defect present in a plate.

42 ENGINEERING↗

Fabrication and Tests of a Resistive-Type Superconducting Fault Current Limiter Module Based on Coated Conductors

The resistivetype superconducting fault current limiter (R-SFCL) is simple in structure, near zero impedance at normal state and can be quickly triggered by the fault current. Thus, it is a possible solution to limit the fault current in the power grid. In this paper, we report the fabrication and test for an R-SFCL module The R-SFCL module consists of seven bifilar coils connected in parallel, which were wound with two parallel 2G tapes. A 5mm spacer was co-wound between adjacent turns to act as the highvoltage insulation. In the tests, we test the current distribution among the bifilar coils, and then simulated short-circuit tests were conducted on the module to obtain its performance under fault current surge.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Passive decay heat removal system design for the integral inherent safety light water reactor (I 2 S-LWR)

The Integral, Inherently Safe Light Water Reactor (I 2 S-LWR) is an innovative Pressurized Water Reactor (PWR) concept being developed by a multi-institutional team led by Georgia Tech and in collaboration with Westinghouse, under the Department of Energy’s Nuclear Energy University Programs Integrated Research Projects (DOE NEUP IRP). The University of Michigan leads the design of the thermalhydraulic and passive safety systems, in collaboration with Westinghouse and Bringham Young University. The I 2 S-LWR features an integral primary system configuration and is more conducive to the implementation of inherent safety features by eliminating potential accidents. In this paper, a novel passive Decay Heat Removal System (DHRS), is presented, consisting of a primary loop, an intermediate loop and a cooling tower loop. This passive system is designed to remove the I 2 S-LWR decay heat in the case of emergency heat removal transients, without the need for external power or operator action. The proposed DHR uses atmosphere as ultimate heat sink, to achieve indefinite decay heat removal. In this paper, firstly, the design of primary and secondary DHRS heat exchangers is optimized. Then the DHR heat removal characteristics are studied using the best-estimate thermal hydraulic code RELAP5. In addition, CFD simulations have been performed in order to investigate the DRHS helical coil primary heat exchanger performance with different coil pipe arrangements, and optimize its design. The performance of the proposed DHRS concept is investigated in case of a Station Black-Out (SBO) scenario. Operation of two, three and four DHRS trains is studied respectively. The findings show that three out of four DHRS trains are sufficient to indefinitely remove the core decay heat successfully during a SBO, and keep the reactor in a safe state without the need of any other auxiliary active system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Control of a Bose-Einstein condensate on a chip by external optical and magnetic potentials

In this paper we explore the possibilities of control of a Bose-Einstein condensate on an atom chip by the use of potentials generated by photonic and magnetic components. We show that the fields produced by both types of components can be modelled by a generic exponential potential and derive analytic expressions that allow for an easy assessment of their impact on a trapped condensate. Using dynamical numerical simulations we study the transport of the condensate between the control structures on a chip. We study in detail different regimes of the condensate behaviour in an evanescent light potential generated by a photonic structure in the vicinity of the condensate and in magnetic potentials generated by a wire or a coil. The calculations are based on the reported parameters of atom chip setups and available photonic and magnetic components. Finally, the model is verified by an experiment with a condensate on an atom chip and a coil. - Highlights: Black-Right-Pointing-Pointer Generic potential used to describe both the optical evanescent and magnetic fields. Black-Right-Pointing-Pointer An analytic closed form solution found for the impact of a generic potential on a BEC. Black-Right-Pointing-Pointer BEC dynamics calculated for potential time sequences attainable in experiments. Black-Right-Pointing-Pointer Conditions for BEC transfer by an external field identified. Black-Right-Pointing-Pointer Exponential-potential model validated by a BEC-on-chip experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PANDEMIC: Occupancy driven predictive ventilation control to minimize energy consumption and infection risk

During the SARS-CoV-2 (COVID-19) pandemic, governments around the world have formulated policies requiring ventilation systems to operate at a higher outdoor fresh air flow rate for a sufficient time, which has led to a sharp increase in building energy consumption. Therefore, it is necessary to identify an energy-efficient ventilation strategy to reduce the risk of infection. In this study, we developed an occupant-number-based model predictive control (OBMPC) algorithm for building ventilation systems. First, we collected the occupancy and Heating, ventilation, and air conditioning system (HVAC) data from March to July 2021. Then, four different models (Auto regression moving average-based multilayer perceptron (ARMA_MLP), Recurrent neural networks (RNN), Long short-term memory networks (LSTM), and Nonhomogeneous Markov with change points detection (NH_Markov)) were used to predict the number of room occupants from 15 min to 24 h ahead with an interval output. We found that each model could predict the number of occupants with 85% accuracy using a one-person offset. Furthermore, the accuracy of 15 min of the ahead prediction could reach 95% with a one-person offset, but none of them could track abrupt changes. The occupancy prediction results were used to calculate the ventilation demand using the Wells-Riley equation, and the upper bound can maintain an infection risk lower than 2% for 93% of the day. This OBMPC model could reduce the coil load by 52.44% and shift the peak load by 3 h up to 5 kW compared with 24 × 7 h full outdoor air (OA) system when people wear masks in the space. The occupancy prediction uncertainty could cause a 9% to 26% difference in demand ventilation, a 0.3°C to 2.4°C difference in zone temperature, a 28.5% to 44.5% difference in outdoor airflow rate, and a 10.7% to 28.2% difference in coil load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗