Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPARATIVE TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Hydrogen no-vent fill testing in a 5 cubic foot (142 liter) tank using spray nozzle and spray bar liquid injection

A total of 38 hydrogen no-vent fill tests were performed in this test series using various size spray nozzles and a spray bar with different hole sizes in a 5 cubic foot receiver tank. Fill levels of 90 percent by volume or greater were achieved in 26 of the tests while maintaining a receiver tank pressure below 30 psia. Spray nozzles were mounted at the top of the tank, whereas, the spray bar was centered in the tank axially. The spray nozzle no-vent fills demonstrated tank pressure and temperature responses comparable to previous test series. Receiver tank pressure responses for the spray bar configuration were similar to the spray nozzle tests with the pressure initially rising rapidly, then leveling off as vapor condenses onto the discharging liquid streams, and finally ramping up near the end of the test due to ullage compression. Both liquid injection techniques tested were capable of filling the receiver tank to 90 percent under variable test conditions. Comparisons between the spray nozzle and spray bar configurations for well matched test conditions indicate the spray nozzle injection technique is more effective in minimizing the receiving tank pressure throughout a no-vent fill compared to the spray bar under normal gravity conditions.

Moran, Matthew E.↗

Hydrogen no-vent testing in a 5 cubic foot (142 liter) tank using spray nozzle and spray bar liquid injection

A total of 38 hydrogen no-vent fill tests were performed in this test series using various size spray nozzles and a spray bar with different hole sizes in a 5 cubic foot receiver tank. Fill levels of 90 percent by volume or greater were achieved in 26 of the tests while maintaining a receiver tank pressure below 30 psia. Spray nozzles were mounted at the top of the tank, whereas, the spray bar was centered in the tank axially. The spray nozzle no-vent fills demonstrated tank pressure and temperature responses comparable to previous test series. Receiver tank pressure responses for the spray bar configuration were similar to the spray nozzle tests with the pressure initially rising rapidly, then leveling off as vapor condenses onto the discharging liquid streams, and finally ramping up near the end of the test due to ullage compression. Both liquid injection techniques tested were capable of filling the receiver tank to 90 percent under variable test conditions. Comparisons between the spray nozzle and spray bar configurations for well matched test conditions indicate the spray nozzle injection technique is more effective in minimizing the receiving tank pressure throughout a no-vent fill compared to the spray bar under normal gravity conditions.

Moran, Matthew E.↗

Shear strength characteristics of mechanically biologically treated municipal solid waste (MBT-MSW) from Bangalore

Highlights: • Shear strength properties of mechanically biologically treated municipal solid waste. • Effect of unit weight and particle size on the shear strength of waste. • Effect of particle size on the strength properties. • Stiffness ratio and the strength ratio of MSW. - Abstract: Strength and stiffness properties of municipal solid waste (MSW) are important in landfill design. This paper presents the results of comprehensive testing of shear strength properties of mechanically biologically treated municipal solid waste (MBT-MSW) in laboratory. Changes in shear strength of MSW as a function of unit weight and particle size were investigated by performing laboratory studies on the MSW collected from Mavallipura landfill site in Bangalore. Direct shear tests, small scale and large scale consolidated undrained and drained triaxial tests were conducted on reconstituted compost reject MSW samples. The triaxial test results showed that the MSW samples exhibited a strain-hardening behaviour and the strength of MSW increased with increase in unit weight. Consolidated drained tests showed that the mobilized shear strength of the MSW increased by 40% for a unit weight increase from 7.3 kN/m{sup 3} to 10.3 kN/m{sup 3} at 20% strain levels. The mobilized cohesion and friction angle ranged from 5 to 9 kPa and 8° to 33° corresponding to a strain level of 20%. The consolidated undrained tests exhibited reduced friction angle values compared to the consolidated drained tests. The friction angle increased with increase in the unit weight from 8° to 55° in the consolidated undrained tests. Minor variations were found in the cohesion values. Relationships for strength and stiffness of MSW in terms of strength and stiffness ratios are developed and discussed. The stiffness ratio and the strength ratio of MSW were found to be 10 and 0.43.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Experimental Uncertainty for a Floating Wind Semisubmersible Under Hydrodynamic Loading

The objective of this paper is to assess the sources of experimental uncertainty in an offshore wind validation campaign focused on better understanding the nonlinear hydrodynamic response behavior of a floating semisubmersible. The test specimen and conditions were simplified compared to other floating wind test campaigns to reduce potential sources of uncertainties and better focus on the hydrodynamic load attributes. Repeat tests were used to understand the repeatability of the test conditions and to assess the level of random uncertainty in the measurements. Attention was also given to understanding bias in all components of the test. The end goal of this work is to set uncertainty bounds on the response metrics of interest, which will be used in future work to evaluate the success of modeling tools in accurately calculating hydrodynamic loads and the associated motion responses of the system.

17 WIND ENERGY↗

Efficient concepts for large erectable space structures

The status of Langley Research Center development of the nestable column concept is reviewed including results of member and truss component tests, and planned assembly studies. In addition, more recent studies of alternative member concepts are presented. Preliminary results on relative efficiency of several types of truss-type columns are compared and future test plans discussed.

Card, M. F.↗

An introduction to a unified approach to flexible rotor balancing

Two types of technique for flexible-rotor balancing are examined: the influence coefficient method, and the modal balancing method. Briefly, the influence coefficient method seeks those correction masses in a predetermined set of planes which will minimize measured vibration (readings) at a series of sensors and speeds, as predicted by influence coefficients relating vibration readings to mass additions; the influence coefficients are normally determined by a series of trial mass tests. The modal balancing method seeks to balance the rotor, one mode at a time, with a set of masses specifically selected not to disturb previously balanced lower modes, the sensitivity to this combination of masses is determined empirically by a series of trial mass tests. The two approaches are compared in supercritical-shaft balancing tests, and some common features are stressed for ultimate incorporation into a unified approach toward flexible-rotor balancing.

Parkinson, A. G.↗

Development of CFD code evaluation criteria and a procedure for assessing predictive capability and performance

Careful validation of computational fluid dynamic (CFD) codes is essential if they are to be used as engineering design tools. Validation must be carried out in a systematic manner to ensure that all code aspects as they apply to the application of interest are understood and, to the greatest extent possible, quantified. A study is being conducted in which a general code validation procedure is defined and demonstrated. A four phase validation procedure is defined in which a series of validation test cases are computed and compared with available analytical solutions and test data. The procedure is demonstrated using the REACT CFD code to compute validation cases for each of the four phases. For phase four, the application of interest, the Space Shuttle Main Engine high pressure fuel turbopump impeller flow field, is computed.

Lin, S. J.↗

Assessment of Experimental Uncertainty for a Floating Wind Semisubmersible under Hydrodynamic Loading: Preprint

The objective of this paper is to assess the sources of experimental uncertainty in an offshore wind validation campaign focused on better understanding the nonlinear hydrodynamic response behavior of a floating semisubmersible. The test specimen and conditions were simplified compared to other floating wind test campaigns to reduce potential sources of uncertainties and better focus on the hydrodynamic load attributes. Repeat tests were used to understand the repeatability of the test conditions and to assess the level of random uncertainty in the measurements. Attention was also given to understanding bias in all components of the test. The end goal of this work is to set uncertainty bounds on the response metrics of interest, which will be used in future work to evaluate the success of modeling tools in accurately calculating hydrodynamic loads and the associated motion responses of the system.

17 WIND ENERGY↗

Comparison of two Galerkin quadrature methods

We compare two methods for generating Galerkin quadrature for problems with highly forward-peaked scattering. In Method 1, the standard Sn method is used to generate the moment-to-discrete matrix and the discrete-to-moment is generated by inverting the moment-to-discrete matrix. In Method 2, which we introduce here, the standard Sn method is used to generate the discrete-to-moment matrix and the moment-to-discrete matrix is generated by inverting the discrete-to-moment matrix. Method 1 has the advantage that it preserves both N eigenvalues and N eigenvectors (in a pointwise sense) of the scattering operator with an N-point quadrature. Method 2 has the advantage that it generates consistent angular moment equations from the corresponding S{sub N} equations while preserving N eigenvalues of the scattering operator with an N-point quadrature. Our computational results indicate that these two methods are quite comparable for the test problem considered. (authors)

97 MATHEMATICS AND COMPUTING↗

Selecting a near-optimal design for multiple criteria with improved robustness to different user priorities

In a decision-making process, relying on only one objective can often lead to oversimplified decisions that ignore important considerations. Incorporating multiple, and likely competing, objectives is critical for balancing trade-offs on different aspects of performance. When multiple objectives are considered, it is often hard to make a precise decision on how to weight the different objectives when combining their performance for ranking and selecting designs. We show that there are situations when selecting a design with near-optimality for a broad range of weight combinations of the criteria is a better test selection strategy compared with choosing a design that is strictly optimal under very restricted conditions. Here, we propose a new design selection strategy that identifies several top-ranked solutions across broad weight combinations using layered Pareto fronts and then selects the final design that offers the best robustness to different user priorities. This method involves identifying multiple leading solutions based on the primary objectives and comparing the alternatives using secondary objectives to make the final decision. We focus on the selection of screening designs because they are widely used both in industrial research, development, and operational testing. The method is illustrated with an example of selecting a single design from a catalog of designs of a fixed size. However, the method can be adapted to more general designed experiment selection problems that involve searching through a large design space.

97 MATHEMATICS AND COMPUTING↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting from Hot-Humid, High Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable, legacy aluminum back surface field (Al-BSF) cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60deg C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission (IEC) Technical Specification 62804-1; 70 deg C/70% RH for 200 h; and 85 deg C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage (I-V) curve tracing. Final characterizations included: Suns-Voc; spatial mapping of external quantum efficiency (EQE); high-resolution photoluminescence (PL), EL, and dark lock-in thermography (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline-corrosion and -delamination as well as other concurrent degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

Seal-rotordynamic-coefficient test results for a model SSME ATD-HPFTP turbine interstage seal with and without a swirl brake

Results are presented from a test program that compares predictions and measurements for a model version of the Space Shuttle Main Engine (SSME) Alternate Turbopump Development (ATD) High-Pressure Fuel Turbopump (HPFTP), with and without a swirl brake. The tests were conducted in order to establish a degree of confidence in seal calculations for the ATD turbopumps. Test results demonstrate that the proposed swirl brake design is effective in reducing the seal destabilizing forces. Without the swirl brake, the cross-coupled stiffness k increases monotonically with increasing inlet tangential velocity. With the swirl break, k tends to either be constant or decrease with increasing inlet tangential velocity. Comparisons between Scharrer's (1988) theory and measurements for the seal without a swirl brake indicate that the predictions can be used to provide design guidelines only.

Childs, D. W.↗

COI Structural Analysis Presentation

This report discusses the structural analysis of the Next Generation Space Telescope Mirror System Demonstrator (NMSD) developed by Composite Optics Incorporated (COI) in support of the Next Generation Space Telescope (NGST) project. The mirror was submitted to Marshall Space Flight Center (MSFC) for cryogenic testing and evaluation. Once at MSFC, the mirror was lowered to approximately 40 K and the optical surface distortions were measured. Alongside this experiment, an analytical model was developed and used to compare to the test results. A NASTRAN finite element model was provided by COI and a thermal model was developed from it. Using the thermal model, steady state nodal temperatures were calculated based on the predicted environment of the large cryogenic test chamber at MSFC. This temperature distribution was applied in the structural analysis to solve for the deflections of the optical surface. Finally, these deflections were submitted for optical analysis and comparison to the interferometer test data.

Cline, Todd↗

100-lbf LO2/CH4 RCS Thruster Testing and Validation

100 pound thrust liquid Oxygen-Methane thruster sized for RCS (Reaction Control System) applications. Innovative Design Characteristics include: a) Simple compact design with minimal part count; b) Gaseous or Liquid propellant operation; c) Affordable and Reusable; d) Greater flexibility than existing systems; e) Part of NASA'S study of "Green Propellants." Hot-fire testing validated performance and functionality of thruster. Thruster's dependence on mixture ratio has been evaluated. Data has been used to calculate performance parameters such as thrust and Isp. Data has been compared with previous test results to verify reliability and repeatability. Thruster was found to have an Isp of 131 s and 82 lbf thrust at a mixture ratio of 1.62.

Barnes, Frank↗

Non-Nuclear Testing of Space Nuclear Systems at NASA MSFC

Highly realistic non-nuclear testing can be used to investigate and resolve potential issues with space nuclear power and propulsion systems. Non-nuclear testing is particularly useful for systems designed with fuels and materials operating within their demonstrated nuclear performance envelope. Non-nuclear testing allows thermal hydraulic, heat transfer, structural, integration, safety, operational, performance, and other potential issues to be investigated and resolved with a greater degree of flexibility and at reduced cost and schedule compared to nuclear testing. The primary limit of non-nuclear testing is that nuclear characteristics and potential nuclear issues cannot be directly investigated. However, non-nuclear testing can be used to augment the potential benefit from any nuclear testing that may be required for space nuclear system design and development. This paper describes previous and ongoing non-nuclear testing related to space nuclear systems at NASA's Marshall Space Flight Center (MSFC).

Houts, Michael G.↗

Non-Nuclear Testing of Fission Technologies at NASA MSFC

Highly realistic non-nuclear testing can be used to investigate and resolve potential issues with space nuclear power and propulsion systems. Non-nuclear testing is particularly useful for systems designed with fuels and materials operating within their demonstrated nuclear performance envelope. Non-nuclear testing also provides an excellent way for screening potential advanced fuels and materials prior to nuclear testing, and for investigating innovative geometries and operating regimes. Non-nuclear testing allows thermal hydraulic, heat transfer, structural, integration, safety, operational, performance, and other potential issues to be investigated and resolved with a greater degree of flexibility and at reduced cost and schedule compared to nuclear testing. The primary limit of non-nuclear testing is that nuclear characteristics and potential nuclear issues cannot be directly investigated. However, non-nuclear testing can be used to augment the potential benefit from any nuclear testing that may be required for space nuclear system design and development. This paper describes previous and ongoing non-nuclear testing related to space nuclear systems at NASA s Marshall Space Flight Center (MSFC).

Houts, Robert G.↗

Comparative Analysis of ACAS-Xu and DAIDALUS Detect-and-Avoid Systems

The Detect and Avoid (DAA) capability of a recent version (Run 3) of the Airborne Collision Avoidance System-Xu (ACAS-Xu) is measured against that of the Detect and AvoID Alerting Logic for Unmanned Systems (DAIDALUS), a reference algorithm for the Phase 1 Minimum Operational Performance Standards (MOPS) for DAA. This comparative analysis of the two systems' alerting and horizontal guidance outcomes is conducted through the lens of the Detect and Avoid mission using flight data of scripted encounters from a recent flight test. Results indicate comparable timelines and outcomes between ACAS-Xu's Remain Well Clear alert and guidance and DAIDALUS's corrective alert and guidance, although ACAS-Xu's guidance appears to be more conservative. ACAS-Xu's Collision Avoidance alert and guidance occurs later than DAIDALUS's warning alert and guidance, and overlaps with DAIDALUS's timeline of maneuver to remain Well Clear. Interesting discrepancies between ACAS-Xu's directive guidance and DAIDALUS's "Regain Well Clear" guidance occur in some scenarios.

Davies, Jason T.↗

Limits of adaptation, residual interferences

Methods of determining linear residual wall interference appear to be well established theoretically; however they need to be validated, for example by comparative studies of test data on the same model in different adaptive-wall wind tunnels as well as in passive, ventilated-wall tunnels. The GARTEur CAST 7 and the CAST 10/DOA 2 investigations are excellent examples of such comparative studies. Results to date in both one-variable and two-variable methods for nonlinear wall interference indicate that a great deal more research and validation are required. The status in 2D flow is advanced over that in 3D flow as is the case generally with adaptive-wall development. Nevertheless, it is now well established that for transonic testing with extensive supercritical flow present, significant wall interference is likely to exist in conventional ventilated test sections. Consequently, residual correction procedures require further development hand-in-hand with further adaptive-wall development.

Mokry, Miroslav↗