Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPACTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

X-ray phase contrast imaging of biological specimens with femtosecond pulses of betatron radiation from a compact laser plasma wakefield accelerator

We show that x-rays from a recently demonstrated table top source of bright, ultrafast, coherent synchrotron radiation [Kneip et al., Nat. Phys. 6, 980 (2010)] can be applied to phase contrast imaging of biological specimens. Our scheme is based on focusing a high power short pulse laser in a tenuous gas jet, setting up a plasma wakefield accelerator that accelerates and wiggles electrons analogously to a conventional synchrotron, but on the centimeter rather than tens of meter scale. We use the scheme to record absorption and phase contrast images of a tetra fish, damselfly and yellow jacket, in particular highlighting the contrast enhancement achievable with the simple propagation technique of phase contrast imaging. Coherence and ultrafast pulse duration will allow for the study of various aspects of biomechanics.

43 PARTICLE ACCELERATORS↗

Compact x-ray microradiograph for in situ imaging of solidification processes: Bringing in situ x-ray micro-imaging from the synchrotron to the laboratory

A laboratory based high resolution x-ray radiograph was developed for the investigation of solidification dynamics in alloys. It is based on a low-power microfocus x-ray tube and is potentially appropriate for x-ray diagnostics in space. The x-ray microscope offers a high spatial resolution down to approximately 5 {mu}m. Dynamic processes can be resolved with a frequency of up to 6 Hz. In reference experiments, the setup was optimized to yield a high contrast for AlCu-alloys. With samples of about 150 {mu}m thickness, high quality image sequences of the solidification process were obtained with high resolution in time and space.

36 MATERIALS SCIENCE↗

Design of a compact electron cyclotron resonance ion source for medium charge state light ions

At the Australian Nuclear Science and Technology Organization we are developing a new isotope ratio mass spectrometer based on the measurement of multiple charge state ions. We have carried out a review of our existing ECR ion source and identified a number of design flaws. For the new instrument, we are producing a new ECR source and have refined the design, in particular by using 3D simulations to improve the magnetic confinement field and by a combination of simulations and experiments to improve the design of the microwave coupling.

43 PARTICLE ACCELERATORS↗

Extraction of negative hydrogen ions from a compact 14 GHz microwave ion source

A pair of permanent magnets has formed enough intensity to realize electron cyclotron resonance condition for a 14 GHz microwave in a 2 cm diameter 9 cm long alumina discharge chamber. A three-electrode extraction system assembled in a magnetic shielding has formed a stable beam of negative hydrogen ions (H{sup -}) in a direction perpendicular to the magnetic field. The measured H{sup -} current density was about 1 mA/cm{sup 2} with only 50 W of discharge power, but the beam intensity had shown saturation against further increase in microwave power. The beam current decreased monotonically against increasing pressure.

43 PARTICLE ACCELERATORS↗

Note: Development of a compact x-ray particle image velocimetry for measuring opaque flows. II. Three-dimensional velocity field reconstruction

An x-ray particle image velocimetry (PIV) system using a cone-beam type x-ray was developed. The field of view and the spatial resolution are 36 x 24.05 mm{sup 2} and 20 {mu}m, respectively. The three-dimensional velocity field was reconstructed by adopting the least squares minimum residue and simultaneous multiplicative algebraic reconstruction techniques. According to a simulation study with synthetic images, the reconstructions were acceptable with 7 projections and 50 iterations. The reconstructed and supplied flow rates differed by only about 6.49% in experimental verification. The x-ray tomographic PIV system would be useful for 3D velocity field information of opaque flows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact, low power radio frequency cavity for femtosecond electron microscopy

Reported here is the design, construction, and characterization of a small, power efficient, tunable dielectric filled cavity for the creation of femtosecond electron bunches in an existing electron microscope without the mandatory use of femtosecond lasers. A 3 GHz pillbox cavity operating in the TM{sub 110} mode was specially designed for chopping the beam of a 30 keV scanning electron microscope. The dielectric material used is ZrTiO{sub 4}, chosen for the high relative permittivity ({epsilon}{sub r}= 37 at 10 GHz) and low loss tangent (tan {delta}= 2 x 10{sup -4}). This allows the cavity radius to be reduced by a factor of six, while the power consumption is reduced by an order of magnitude compared to a vacuum pillbox cavity. These features make this cavity ideal as a module for existing electron microscopes, and an alternative to femtosecond laser systems integrated with electron microscopes.

36 MATERIALS SCIENCE↗

Demonstration of charge breeding in a compact room temperature electron beam ion trap

For the first time, a small room-temperature electron beam ion trap (EBIT), operated with permanent magnets, was successfully used for charge breeding experiments. The relatively low magnetic field of this EBIT does not contribute to the capture of the ions; single-charged ions are only caught by the space charge potential of the electron beam. An over-barrier injection method was used to fill the EBIT's electrostatic trap with externally produced, single-charged potassium ions. Charge states as high as K{sup 19+} were reached after about a 3 s breeding time. The capture and breeding efficiencies up to 0.016(4)% for K{sup 17+} have been measured.

43 PARTICLE ACCELERATORS↗

Spent fuel utilization in a compact traveling wave reactor

In recent years, several innovative designs of nuclear reactors are proposed. One of them is Traveling Wave Reactor (TWR). The unique characteristic of a TWR is the capability of breeding its own fuel in the reactor. The reactor is fueled by mostly depleted, natural uranium or spent nuclear fuel and a small amount of enriched uranium to initiate the fission process. Later on in the core, the reactor gradually converts the non-fissile material into the fissile in a process like a traveling wave. In this work, a TWR with spent nuclear fuel blanket was studied. Several parameters such as reactivity coefficients, delayed neutron fraction, prompt neutron generation lifetime, and fission power, were analyzed. The discharge burnup composition was also analyzed. The calculation is performed by a continuous energy Monte Carlo code McCARD.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Materials analysis and particle probe: A compact diagnostic system for in situ analysis of plasma-facing components (invited)

The objective of the materials analysis particle probe (MAPP) in NSTX is to enable prompt and direct analysis of plasma-facing components exposed to plasma discharges. MAPP allows multiple samples to be introduced to the level of the plasma-facing surface without breaking vacuum and analyzed using X-ray photoelectron spectroscopy (XPS), ion-scattering and direct recoil spectroscopy, and thermal desorption spectroscopy (TDS) immediately following the plasma discharge. MAPP is designed to operate as a diagnostic within the {approx}12 min NSTX minimum between-shot time window to reveal fundamental plasma-surface interactions. Initial calibration demonstrates MAPP's XPS and TDS capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact solid-state neutral particle analyzer in current mode

Solid state neutral particle analyzer (ssNPA) arrays are operated in current mode on the DIII-D tokamak and the National Spherical Torus Experiment (NSTX). Compared with conventional pulse-counting NPAs, current-mode operation sacrifices energy resolution to obtain economical, high-bandwidth, pitch-angle resolved measurements. With the success from a new three-channel near-vertical-view current mode ssNPA on DIII-D, the apertures on an existing array on NSTX were expanded to increase the particle influx. The sightlines of both arrays intersect heating beams, enabling both active and passive charge exchange measurements. The spatial resolution at beam intersection is typically 5 cm on both devices. Directly deposited ultra-thin foils on the detector surface block stray photons below the energy of 1 keV and also set low energy threshold about 25 keV for deuterium particle detection. Oscillations in neutral flux produced by high frequency magnetohydrodynamics (MHD) instabilities are readily detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new compact, high sensitivity neutron imaging system

We have developed a new small neutron imaging system (SNIS) diagnostic for the OMEGA laser facility. The SNIS uses a penumbral coded aperture and has been designed to record images from low yield (10{sup 9}-10{sup 10} neutrons) implosions such as those using deuterium as the fuel. This camera was tested at OMEGA in 2009 on a rugby hohlraum energetics experiment where it recorded an image at a yield of 1.4 Multiplication-Sign 10{sup 10}. The resolution of this image was 54 {mu}m and the camera was located only 4 meters from target chamber centre. We recently improved the instrument by adding a cooled CCD camera. The sensitivity of the new camera has been fully characterized using a linear accelerator and a {sup 60}Co {gamma}-ray source. The calibration showed that the signal-to-noise ratio could be improved by using raw binning detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy spread inhibition of compact electron bunch driven by circularly polarized laser pulse

The problem of energy dispersion of a direct laser accelerated electron bunch emerging from a nano-meshed graphene target is investigated. To study the effects of the laser polarization state on the energy spread, numerical calculations and particle-in-cell simulations of evolving one-dimensional confined electron bunch dynamics are performed. It is proved that a circularly polarized laser pulse can inhibit energy dispersion more efficiently than a linearly polarized laser pulse with the same laser and target parameters. That is because the Coulomb expansion of the electron bunch gets more attenuated for a circularly polarized laser pulse compared with a linearly polarized pulse due to the slowly varying temporal laser intensity.

43 PARTICLE ACCELERATORS↗

RF undulator for compact X-ray SASE source of variable wavelength

A room-temperature RF undulator, fed by Ka-band radiation and intended to produce {approx}1 nm wavelength radiation using moderate energy electrons, is considered. The necessary electron bunches with energy 0.2-1 GeV could be produced by petawatt laser pulses injected into plasma bubbles.

43 PARTICLE ACCELERATORS↗

Cold quark matter in compact stars

We used an equation of state for the cold quark matter to the study of properties of quark stars. We also discuss the absolute stability of quark matter and compute the mass-radius relation for self-bound stars.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Creation of quantum-degenerate gases of ytterbium in a compact 2D-/3D-magneto-optical trap setup

We report on the first experimental setup based on a 2D-/3D-magneto-optical trap (MOT) scheme to create both Bose-Einstein condensates and degenerate Fermi gases of several ytterbium isotopes. Our setup does not require a Zeeman slower and offers the flexibility to simultaneously produce ultracold samples of other atomic species. Furthermore, the extraordinary optical access favors future experiments in optical lattices. A 2D-MOT on the strong {sup 1}S{sub 0}{yields}{sup 1}P{sub 1} transition captures ytterbium directly from a dispenser of atoms and loads a 3D-MOT on the narrow {sup 1}S{sub 0}{yields}{sup 3}P{sub 1} intercombination transition. Subsequently, atoms are transferred to a crossed optical dipole trap and cooled evaporatively to quantum degeneracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a fast scintillator based beam phase measurement system for compact superconducting cyclotrons

In an isochronous cyclotron, measurements of central phase of the ion beam with respect to rf and the phase width provide a way to tune the cyclotron for maximum energy gain per turn and efficient extraction. We report here the development of a phase measurement system and the measurements carried out at the Variable Energy Cyclotron Centre's (VECC's) K= 500 superconducting cyclotron. The technique comprises detecting prompt {gamma}-rays resulting from the interaction of cyclotron ion beam with an aluminium target mounted on a radial probe in coincidence with cyclotron rf. An assembly comprising a fast scintillator and a liquid light-guide inserted inside the cyclotron was used to detect the {gamma}-rays and to transfer the light signal outside the cyclotron where a matching photo-multiplier tube was used for light to electrical signal conversion. The typical beam intensity for this measurement was a few times 10{sup 11} pps.

43 PARTICLE ACCELERATORS↗

Compact cryogenically cooled Ti:Sapphire dual multi-kilohertz amplifiers for synchrotron radiation ultra-fast x-ray applications

A titanium-doped sapphire regenerative dual-amplifier array operating at multi-kHz repetition rates has been developed for synchrotron radiation ultra-fast x-ray applications. The thermal lensing of the crystal in the amplifiers is virtually eliminated by cryogenic cooling of the laser crystal. The output energy of the amplifiers is measured to be greater than 2.6 mJ and the pulse length was compressed to less than 70 fs. The output laser mode is a near perfect Gaussian TEM00 with an M{sup 2} factor of 1.02. The performance of the amplifier system is in excellent agreement with theoretical calculation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗