Mossbauer vibration calibration systems evaluated

Mossbauer effect vibration calibrator measures the velocity of high frequency, low amplitude vibration at various velocity and frequency ranges. It contains a highly precise calibrations standard unit and a vibration measuring system and may be applied to ultrafine testing and calibrating prezoelectric shakers, and vibration transducers.

Hobbs, J. V.↗

Investigation of factors affecting the heater wire method of calibrating fine wire thermocouples

An analytical investigation was made of a transient method of calibrating fine wire thermocouples. The system consisted of a 10 mil diameter standard thermocouple (Pt, Pt-13% Rh) and an 0.8 mil diameter chromel-alumel thermocouple attached to a 20 mil diameter electrically heated platinum wire. The calibration procedure consisted of electrically heating the wire to approximately 2500 F within about a seven-second period in an environment approximating atmospheric conditions at 120,000 feet. Rapid periodic readout of the standard and fine wire thermocouple signals permitted a comparison of the two temperature indications. An analysis was performed which indicated that the temperature distortion at the heater wire produced by the thermocouple junctions appears to be of negligible magnitude. Consequently, the calibration technique appears to be basically sound, although several practical changes which appear desirable are presented and discussed. Additional investigation is warranted to evaluate radiation effects and transient response characteristics.

Keshock, E. G.↗

Energy calibration of a cosmic ray ionization spectrometer

The NASA/GSFC high energy cosmic ray experiment was calibrated during the summer of 1970 using protons and pions with energies from 9.3 GeV to 17.6 GeV. The best measure found for the energy E of an incoming primary particle is sigma I, the total number of ionizing particles observed in the instrument, summed over the various iron modules. The resolution in the calibration energy range is about + or - 30 percent (s.d.) over a wide range of incident angles and positions. The calibration function may be parameterized as e = sigma I/K, where K is predominantly a function of the location of the first interaction and the trajectory of the incoming particle.

Whiteside, H.↗

Calibration of radiation detectors in the ultraviolet region between 972 and 2500 A

The development of experimental setups and procedures is considered for calibrating photosensitive devices in the spectral range 1022 to 2500 A for which no direct calibration techniques exist. An indirect technique that uses a sodium salicylate detector calibrated outside this range was developed for use as a secondary standard. The primary standard was a xenon-filled ionization chamber, which is an absolute standard over the wavelength interval 972 to 1022 A. Measurements made by this method were checked at 1470 A with a xenon lamp and at 2537 A with a mercury arc lamp and a 0.5 m blaze monochromator with a grating blazed at 2000 A. The overall accuracy of the measurements was + or - 40 percent or better.

Mcclenahan, J. O.↗

L-/S-band calibration error analysis.

Results of a statistical error analysis performed to determine the degree of uncertainty encountered when calibrating steerable receiving antennas with the solar calibration method. The analysis considers the propagation of precision error indices. It is shown that a worst-case one-sigma (1 sigma) uncertainty of plus or minus 0.8 dB in system noise temperature occurs for a solar calibration at L-band. Somewhat better precision can be achieved by monitoring the antenna gain-to-noise temperature ratio at a station; a worst-case uncertainty of plus or minus 0.5 dB (1 sigma) can be realized. An error analysis is made of a method to determine absolute antenna gain based upon solar flux density. The uncertainty in this type of measurement is plus or minus 0.7 dB (1 sigma) at L- and S-band frequencies.

Taylor, R. E.↗

Vhf/uhf stellar calibration error analysis.

Results of a statistical error analysis performed to determine the degree of uncertainty encountered when calibrating steerable vhf/uhf receiving antennas with the stellar calibration method. The analysis considers the propagation of precision error indices. It is shown that an antenna gain calibration by the stellar method has a one-sigma (1 sigma) uncertainty of plus or minus 0.65 dB at 1440 MHz (L-band), and plus or minus 0.8 dB (1 sigma) at 136 MHz (vhf). Somewhat increased precision can be achieved by monitoring the antenna gain-to-noise temperature ratio at a station; a worst-case uncertainty of plus or minus 0.4 dB (1 sigma) can be realized at both L-band and vhf. Finally, field test measurements of antenna gain, obtained at 136 MHz in the NASA space tracking and data acquisition network, demonstrate an uncertainty of plus or minus 1.0 dB or less, which effectively confirms the analytical result.

Taylor, R. E.↗

Piston manometer as an absolute standard for vacuum-gauge calibration.

Determination of total pressure in a calibration volume by measuring the force on a thin circular disk, of accurately-known area, that is freely suspended in a hole in the container wall, so that the disk is substantially flush with the wall. The disk almost fills the hole, so that there is a narrow annular gap. A continuous flow of calibrating gas, injected into the container in order to maintain a desired pressure, passes through the annular gap to a diffusion pump. The ratio of pressures on the two faces of the disk is on the order of 100:1, so that downstream pressure need be known only nominally in order to deduce the upstream pressure. Force on the disk is measured by a balance that is calibrated in situ with dead weights. In one arrangement, pressures in the range from 10 to 500 microtorr were measured with an estimated probable error of (1 microtorr + 1%).

Warshawsky, I.↗

Calibration of a laboratory spectrophotometer for specular light by means of stacked glass plates.

Stacked glass plates have been used to calibrate a laboratory spectrophotometer, over the spectral range 0.5-2.5 microns, for specular light. The uncalibrated instrument was characterized by systematic errors when used to measure the reflectance and transmittance of stacked glass plates. Calibration included first, a determination of the reflectance of a standard composed of barium sulfate paint deposited on an aluminum plate; second, the approximation of the reflectance and transmittance residuals between observed and computed values by means of cubic equations; and, finally, the removal of the systematic errors by a computer. The instrument, after calibration, was accurate to 1% when used to measure the reflectance and transmittance of stacked glass plates.

Allen, W. A.↗

Piston manometer as an absolute standard for vacuum-gauge calibration.

Determination of the total pressure in a calibration volume by measuring the force on a thin circular disk, of accurately known area, that is freely suspended in a hole in the container wall, so that the disk is substantially flush with the wall. The disk almost fills the hole, so that there is a narrow annular gap. A continuous flow of calibrating gas, injected into the container in order to maintain a desired pressure, passes through the annular gap to a diffusion pump. The ratio of pressures on the two faces of the disk is of the order of 100:1, so that downstream pressure need be known only nominally in order to deduce the upstream surface. Force on the disk is measured by a balance that is calibrated in situ with dead weights. In one arrangement, pressures in the range from 10 to 500 microtorr were measured with an estimated probable error of (1 microtorr + 1%).

Warshawsky, I.↗

Calibration of solar cells using high-altitude aircraft.

A high altitude airplane has been used to obtain the outer space short circuit current of solar cells. The solar cells are mounted in a collimating tube and are measured at approximately 5000 foot intervals between 12,000 and 47,000 feet. The air mass is calculated for each altitude using the standard formula and the resulting curve is extrapolated to air mass zero. The effects on the solar cell output of a haze layer located at the tropopause has been observed. It is necessary to fly above this layer to ensure accurate results. Airplane calibrations of several primary standard cells calibrated on high altitude balloons show agreement within 0.5 per cent. Prediction of the output of satellite power supplies using airplane calibrated cells shows an accuracy of better than 1 per cent.

Brandhorst, H. W., Jr.↗

The Nimbus 4 infrared spectroscopy experiment. I - Calibrated thermal emission spectra.

Measurement of the infrared spectrum of the earth and atmosphere between 400 and 1600/cm. In an effort to obtain spectra with high absolute accuracy, it was necessary to incorporate many factors into the calibration, including small departures from unity in the emissivity of the on-board calibration source, imbalance between cold and warm calibration ports, and effects due to orbital variations in instrument temperature. The inclusion of such higher order corrections, along with careful data screening processes, has ensured a high quality data set that can be used in a variety of geophysical and meteorological investigations. Representative samples of data are presented that illustrate the behavior of the thermal emission spectra under a variety of conditions encountered in a typical orbit, including extremes in temperature, surface reststrahlung (or residual ray) effects, and various types of cloud conditions.

Hanel, R. A.↗

Piston manometer as an absolute standard for vacuum-gage calibration in the range 2 to 500 millitorr

A thin disk is suspended, with very small annular clearance, in a cylindrical opening in the base plate of a calibration chamber. A continuous flow of calibration gas passes through the chamber and annular opening to a downstream high vacuum pump. The ratio of pressures on the two faces of the disk is very large, so that the upstream pressure is substantially equal to net force on the disk divided by disk area. This force is measured with a dynamometer that is calibrated in place with dead weights. A probable error of + or - (0.2 millitorr plus 0.2 percent) is attainable when downstream pressure is known to 10 percent.

Warshawsky, I.↗

Piston manometer as an absolute standard for vacuum gage calibration in the range 10 to 700 microtorr

Total pressure in a calibration chamber is determined by measuring the force on a disk suspended in an orifice in the baseplate of the chamber. The disk forms a narrow annular gap with the orifice. A continuous flow of calibration gas passes through the chamber and annulus to a downstream pumping system. The ratio of pressures on the two faces of the disk exceeds 100:1, so that chamber pressure is substantially equal to the product of disk area and net force on the disk. This force is measured with an electrodynamometer that can be calibrated in situ with dead weights. Probable error in pressure measurement is plus or minus (0.5 microtorr + 0.6 percent).

Warshawsky, I.↗

Calibration plan for ultraviolet spectrometer experiment S169

The calibration test equipment presented is employed to calibrate completely assembled and flight-ready Apollo Ultraviolet Spectrometers (UVS) consisting of a vacuum system in which the UVS can be installed. In it a premonochromator produces a monochromatic beam at any desired wavelength from a UV source. This beam can be focused by an adjustable transfer mirror to any point on the entrance slit of the UVS. The transfer mirror can also direct the beam to one or both of two absolutely calibrated reference photomultiplier tubes to determine the number of photons which enter the UVS. A movable mirror rhomb is also provided to intermittently monitor the number of photons in the beam when the beam is centered on the entrance slit.

Source record↗

Flight calibration tests of a nose-boom-mounted fixed hemispherical flow-direction sensor

Flight calibrations of a fixed hemispherical flow angle-of-attack and angle-of-sideslip sensor were made from Mach numbers of 0.5 to 1.8. Maneuvers were performed by an F-104 airplane at selected altitudes to compare the measurement of flow angle of attack from the fixed hemispherical sensor with that from a standard angle-of-attack vane. The hemispherical flow-direction sensor measured differential pressure at two angle-of-attack ports and two angle-of-sideslip ports in diametrically opposed positions. Stagnation pressure was measured at a center port. The results of these tests showed that the calibration curves for the hemispherical flow-direction sensor were linear for angles of attack up to 13 deg. The overall uncertainty in determining angle of attack from these curves was plus or minus 0.35 deg or less. A Mach number position error calibration curve was also obtained for the hemispherical flow-direction sensor. The hemispherical flow-direction sensor exhibited a much larger position error than a standard uncompensated pitot-static probe.

Armistead, K. H.↗

An electronically gated gamma and X-ray calibration scheme.

The construction and use are described for a radioactive calibration source that produces an electronic gating pulse when a calibration gamma ray is emitted and makes it possible to employ this source in many calibration or stabilizing tasks without the disadvantage of having to introduce extra counts into the unknown spectrum. The described source is radioactively safe, easy to construct, and has the ability of producing gating efficiencies as high as 98%.

Forrest, D. J.↗

Far ultraviolet spectral radiance calibrations at NBS.

The range of NBS radiometric calibration services has been extended into the far ultraviolet region of the spectrum where a dc high-power hydrogen wall-stabilized arc is used as a primary standard of spectral radiance. A capability in the range from 130 to 360 nm (overlapping conventional tungsten strip lamp radiometry) is presently available with estimated uncertainties between 5 and 10%, depending upon wavelength. The status of radiometric source standards in the far ultraviolet is briefly reviewed, and the hydrogen arc and NBS calibration facility are described in detail. The use of commercially available mercury Krefft-Rossler lamps and deuterium arc lamps as transfer or secondary standards is discussed, and the spectra of these lamps calibrated with the hydrogen arc standard are presented.

Ott, W. R.↗