Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Circumgalactic Oxygen Absorption and Feedback

O vi absorption in quasar spectra caused by intervening circumgalactic atmospheres suggests a downturn in the atmospheric column density in sightlines passing beyond about 100 kpc from central star-forming galaxies. This turnover supports the hypothesis that the oxygen originates in the central galaxies. When converted into oxygen space density using an Abel integral inversion, the O vi columns require ≳10{sup 9} M {sub ⊙} of oxygen concentrated near 100 kpc. Circumgalactic gas within this radius cools in less than 1 Gyr and radiates ∼10{sup 42.2} erg s{sup −1} overall. The feedback power necessary to maintain such oxygen-rich atmospheres for many Gyr cannot be easily supplied by galactic supernovae. However, massive central black holes in star-forming galaxies may generate sufficient accretion power and intermittent shock waves at r∼100 kpc to balance circumgalactic radiation losses in late-type L{sup ⋆} galaxies. The relative absence of O vi absorption observed in early-type, passive L{sup ⋆} galaxies may arise from enhanced AGN feedback from their more massive central black holes.

79 ASTRONOMY AND ASTROPHYSICS↗

Applications of Lagrangian Dispersion Modeling to the Analysis of Changes in the Specific Absorption of Elemental Carbon

We use a Lagrangian dispersion model driven by a mesoscale model with four-dimensional data assimilation to simulate the dispersion of elemental carbon (EC) over a region encompassing Mexico City and its surroundings, the study domain for the 2006 MAX-MEX experiment, which was a component of the MILAGRO campaign. The results are used to identify periods when biomass burning was likely to have had a significant impact on the concentrations of elemental carbon at two sites, T1 and T2, downwind of the city, and when emissions from the Mexico City Metropolitan Area (MCMA) were likely to have been more important. They are also used to estimate the median ages of EC affecting the specific absorption of light, aABS, at 870 nm as well as to identify periods when the urban plume from the MCMA was likely to have been advected over T1 and T2. Values of aABS at T1, the nearer of the two sites to Mexico City, were smaller at night and increased rapidly after mid-morning, peaking in the mid-afternoon. The behavior is attributed to the coating of aerosols with substances such as sulfate or organic carbon during daylight hours, but such coating appears to be limited or absent at night. Evidence for this is provided by scanning electron microscope images of aerosols collected at three sampling sites. During daylight hours the values of aABS did not increase with aerosol age for median ages in the range of 1-4 hours. There is some evidence for absorption increasing as aerosols were advected from T1 to T2 but the statistical significance of that result is not strong.

09 BIOMASS FUELS↗

Dataset used to improve liquid water absorption models in the microwave

Two datasets, one a compilation of laboratory data and one a compilation from three field sites, are provided here. These datasets provide measurements of the real and imaginary refractive indices and absorption as a function of cloud temperature. These datasets were used in the development of the new liquid water absorption model that was published in Turner et al. 2015.

54 ENVIRONMENTAL SCIENCES↗

The Structure of the Homogeneous Oxidation Catalyst, Mn(II)(Br[superscript -1])[subscript x], in Supercritical Water: An X-ray Absorption Fine-Structure Study

Extended X-ray absorption fine structure (EXAFS) and X-ray absorption near edge structure (XANES) spectroscopies were used to probe the first-shell coordination structure about Mn(II) and Br{sup -1} ions that exist as contact ion pairs in supercritical water. This work was performed to clarify why solutions of MnBr{sub 2} in supercritical water are known to effectively catalyze the aerobic oxidative synthesis of terephthalic acid from p-xylene as well as a number of other methylaromatic compounds. The Mn and Br K-edge spectra were collected at the bending magnet beamline (sector 20) at the Advanced Photon Source, Argonne National Laboratory. The first-shell coordination structure about the Mn(II) ion changes from octahedral at ambient conditions to tetrahedral at supercritical conditions. Under supercritical conditions, the measured bond distances of Mn-OH{sub 2} and Mn-Br are 2.14 and 2.46 {angstrom}, respectively. Direct contact ion pairs form with about 2 Br{sup -1} ions present in the first coordination shell of the Mn(II) ion. The structure of dissolved MnBr{sub 2}, below 1.0 m, changes from essentially [Mn(II)(H{sub 2}O){sub 6}]{sup +2} to [Mn(II)(H{sub 2}O){sub 2}(Br{sup -1}){sub 2}] in supercritical water (scH{sub 2}O). When an excess of Br{sup -1} ion is added, the bromide coordination number increases and the number of water molecules decreases. The results show that the initial MnBr{sub 2} catalyst in scH{sub 2}O is tetrahedral with two Mn-Br contact ion pairs. The presence of the acetate anion deactivates the catalyst by formation of insoluble MnO.

43 PARTICLE ACCELERATORS↗

Time-resolved infrared absorption studies of the dynamics of radical reactions.

There is very little information available about the dynamics of radical+radical interactions. These processes are important in combustion being chain termination steps as well as generating new molecular species. To study these processes, a new experimental apparatus has been constructed to investigate radical-radical dynamics. The first radical or atomic species is produced with a known concentration in a microwave discharge flow system. The second is produced by pulsed laser photolysis of a suitable photolyte. The time dependence of individual rovibrational states of the product is followed by absorption of a continuous infrared laser. This approach will allow the reaction of interest to be differentiated from other radical reactions occurring simultaneously. The experimental approach is highly versatile, being able to detect a number of molecular species of particular interest to combustion processes such as water, methane, acetylene etc. at the state specific level. State specific infrared absorption coefficients of radicals can be measured in situ allowing for the determination of the absolute concentrations and hence branching ratios for reactions having multiple reaction pathways.

03 NATURAL GAS↗

THE ABSORPTION OF HYDROGEN ON LOW PRESSURE HYDRIDE MATERIALS

For this study, hydrogen getter materials (Zircaloy-4 and pure zirconium) that have a high affinity for hydrogen (and low overpressure) have been investigated to determine the hydrogen equilibrium pressure on Zircaloy-4 and pure zirconium. These materials, as with most getter materials, offered significant challenges to overcome given the low hydrogen equilibrium pressure for the temperature range of interest. Hydrogen-zirconium data exists for pure zirconium at 500 C and the corresponding hydrogen overpressure is roughly 0.01 torr. This manuscript presents the results of the equilibrium pressures for the absorption and desorption of hydrogen on zirconium materials at temperatures ranging from 400 C to 600 C. The equilibrium pressures in this temperature region range from 150 mtorr at 600 C to less than 0.1 mtorr at 400 C. It has been shown that the Zircaloy-4 and zirconium samples are extremely prone to surface oxidation prior to and during heating. This oxidation precludes the hydrogen uptake, and therefore samples must be heated under a minimum vacuum of 5 x 10{sup -6} torr. In addition, the Zircaloy-4 samples should be heated at a sufficiently low rate to maintain the system pressure below 0.5 mtorr since an increase in pressure above 0.5 mtorr could possibly hinder the H{sub 2} absorption kinetics due to surface contamination. The results of this study and the details of the testing protocol will be discussed.

08 HYDROGEN↗

Ionic Liquid Development for Absorption Heat Pump Applications

Ionic liquids (ILs) are a unique class of solvents with many potential applications, including absorption heating/cooling. Due to the large number of possible combinations of cations and anions, it is possible to tune the IL to obtain the required properties for the application of interest. Many ILs are very hydrophilic, while even the most hydrophobic ILs often absorb significant amounts of water. The presence of water in an IL can have a large effect on the system properties. For instance, a small amount of dissolved water often leads to a dramatic reduction in the viscosity of the mixture. Dissolved water also affects the ionic conductivity of ILs and alters the solvation power of ILs for both polar and non-polar solutes. Knowledge of the phase diagram of these IL/water mixtures therefore is essential when designing absorption heating systems. Measuring isotherms often requires time consuming and/or expensive experiments, and does not necessarily lead to a deeper understanding of the molecular level interactions responsible for water-IL interactions. In contrast, molecular simulations are relatively inexpensive to perform, allowing one to screen potential ILs for a given application. Simulation also provides a detailed picture of how water and a given IL interact, thereby providing insight into ways of designing an IL to have a desired water solubility. Toward this end, atomistic-level Monte Carlo (MC) simulations have been performed to predict isotherms for a variety of IL/water mixtures. The simulations predict that exchanging some of the IL cations with a small metal cation can lead to an increase in the hydrophilicity of the IL, which impacts the capacity of the fluid and the enthalpy of mixing. Molecular dynamics simulations, which unlike Monte Carlo simulations capture timedependent properties, were also carried out to estimate the relative viscosities of the solutions.

Absorption↗

A Remote Absorption Process for Disposal of Evaporate and Reverse Osmosis Concentrates

Many commercial nuclear plants and DOE facilities generate secondary waste streams consisting of evaporator bottoms and reverse osmosis (RO) concentrate. Since liquids are not permitted in disposal facilities, these waste streams must be converted to dry solids, either by evaporation to dried solids or by solidification to liquid-free solids. Evaporation of the liquid wastes reduces their volume, but requires costly energy and capital equipment. In some cases, concentration of the contaminants during drying can cause the waste to exceed Class A waste for nuclear utilities or exceed DOE transuranic limits. This means that disposal costs will be increased, or that, when the Barnwell, SC disposal site closes to waste outside of the Atlantic Compact in July 2008, the waste will be precluded from disposal for the foreseeable future). Solidification with cement agents requires less energy and equipment than drying, but results in a volume increase of 50-100%. The doubling or tripling of waste weight, along with the increased volume, sharply increases shipping and disposal costs. Confronted with these unattractive alternatives, Diversified Technologies Services (DTS), in conjunction with selected nuclear utilities and D and D operations at Rocky Flats, undertook an exploratory effort to convert this liquid wastewater to a solid without using cement. This would avoid the bulking effect of cement, and permit the waste to be disposed of the Energy Solutions facility in Utah as well as some DOE facilities. To address the need for an attractive alternative to drying and cement solidification, a test program was developed using a polymer absorbent media to convert the concentrate streams to a liquid-free waste form that meets the waste acceptance criteria of the pertinent burial sites. Two approaches for mixing the polymer with the liquid were tested: mechanical mixing and in-situ incorporation. As part of this test program, a process control program (PCP) was developed that is 100% scalable from a concentrate test sample as small as 50 grams to full-scale processing of 100 cubic foot containers or larger. In summary: The absorption process offers utilities a viable and less costly alternative to on-site drying or solidification of concentrates. The absorption process can be completed by site personnel or by a vendor as a turnkey service. The process is suitable for multiple types of waste, including RO and evaporator concentrates, sludges, and other difficult to process waters and wet solids. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Large-scale synthesis, characterization and microwave absorption properties of carbon nanotubes of different helicities

Carbon nanotubes of high helicity (H-HCNTs, Sample A) have been synthesized in large-scale by pyrolysis of acetylene at 450 deg. C over Fe nanoparticles derived from coprecipitation/hydrogen reduction method. With controlled introduction of hydrogen during acetylene pyrolysis, CNTs of low helicity (L-HCNTs, Sample B) and worm-like CNTs (Sample C) were obtained in large quantities. The yields of the CNTs products are high, especially that of H-HCNTs (ca. 7474%). The complex permittivity and permeability of Composites A, B, and C that contain Samples A, B and C (30 wt%) were measured in the 2-18 GHz frequency range. Good absorption of electromagnetic wave (reflection loss<-20 dB) was observed in the 7.18-10.68 and 7.5-10.7 GHz range over Composites B and C (2.0-3.0 mm thickness), respectively. Thus, through the suggested route, CNTs can be produced easily and selectively in large quantities. The lightweight materials can be utilized for microwave absorption. - Graphical abstract: FESEM image of Sample B and reflection loss versus frequency of Composite B (containing 30 wt% of Sample B) in the range of 2-18 GHz.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Modelling aging effects on a thermal cycling absorption process column

Palladium coated on alumina is used in hydrogen separation systems operated at CEA/Valduc, and more particularly in Thermal Cycling Absorption Process columns. With such materials, tritium decay is known to induce aging effects which have direct side effects on hydrogen isotopes absorption isotherms. Furthermore in a TCAP column, aging occurs in an heterogeneous way. The possible impacts of these intrinsic material evolutions on the separation performances are investigated here through a numerical approach. (authors)

36 MATERIALS SCIENCE↗

Self-Absorption Corrections for Plutonium Measurements With the Tomographic Gamma Scanner - 17325

The Tomographic Gamma Scanner (TGS) is a Non-Destructive Assay (NDA) instrument that combines high-resolution gamma spectroscopy with low spatial resolution three-dimensional image reconstruction in order to reduce bias and improve precision for measurements of drummed waste. The TGS technique is especially suited to measure containers with non-uniform source distributions and low-to me-dium-density heterogeneous matrices, compared with traditional NDA methods. Canberra recently built, installed, and commissioned a TGS system, intended primarily for the measurement of plutonium (Pu) bearing waste, at a European nu-clear fuel reprocessing facility. Pu assays using the TGS technique present technical challenges distinct from those typically encountered in traditional LLW applications. Among these is the need to apply corrections for self-absorption effects that occur on scales smaller than the TGS spatial resolution, and can compromise the assay result if not included in the TGS imaging methodology. We present a brief review of the Self Absorption Correction (SAC) technique, and discuss the complications involved with its application to the TGS methodology with examples from our recent experience. This work continues a Canberra history of further developing and refining a technique to solve emerging problems, having commercialized the original methodology by partnering with the research institution that pioneered it. The TGS and the SAC methodologies were originally developed by Los Alamos National Laboratory (LANL) and John Fleissner respectively, and this work illustrates how Canberra has implemented an advancement of these techniques in a new TGS system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of a nuclear hybrid energy system using absorption chillers and stratified chilled-water storage with an mPower reactor - 187

The intermittency of renewable energy technology, such as wind and solar power, puts strain on electric grids, often forcing carbon-based and nuclear sources of energy to operate in a load follow mode. Operating nuclear reactors in a load-follow fashion is undesirable due to the associated thermal and mechanical stresses placed on the fuel and reactor components. Various methods of Thermal Energy Storage (TES) can be coupled to nuclear (or renewable) power sources to help absorb grid instabilities caused by daily load demand changes and renewable intermittency. This is known as a Nuclear Hybrid Energy System (NHES). Previous research has found that a stratified chilled-water storage tank can help displace peak cooling loads to off-peak hours. In this study, a dynamic single effect, lithium bromide absorption chiller model was developed as a callable FORTRAN subroutine. Cooling towers, a stratified chilled-water storage tank, and cooling loads characteristic of a large campus were included to form a comprehensive TES model. This TES model was coupled to a high-fidelity mPower sized Small Modular Reactor (SMR) FORTRAN code that provides the transient behavior of primary and secondary-side components. Control algorithms based on excess capacity and conditions in the stratified chilled-water storage tank were used to determine when to divert low-pressure steam from the turbines to the absorption chillers in order to keep reactor power near steady-state. Simulation results depict how the TES system and SMR interact, and demonstrate that stratified chilled-water storage is a viable TES technology for an SMR in a NHES. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Extension of the Inverse Adding-Doubling Method to the Measurement of Wavelength-Dependent Absorption and Scattering Coefficients of Biological Samples

Light interaction with biological tissue can be described using three parameters: the scattering and absorption coefficients (us and ua), as well as the anisotropy (g) which describes the directional dependence of the scattered photons. Accurately determining these optical properties for different tissue types at specific wavelengths, and simultaneously, would be beneficial for a variety of different biomedical applications. The goal of this project was to take a user-defined g-value and determine the remaining two parameters for a specified wavelength range for an integrating sphere with a collimated white light input source system. A fully automated computer program and process was developed to collect data for all wavelengths in a timely and accurate manner. LabVIEW was used to write programs to automate: raw intensity data collection from a spectrometer equipped integrating sphere, conversion of the data into a format for analysis via Scott Prahl's Inverse Adding-Doubling (IAD) C code execution, and computation of the optical properties based on the output from the IAD code. To allow data to be passed efficiently between LabVIEW and C code program modules, the two were combined into a single program (OPT 3.1). OPT 3.1 was tested using tissue mimicking phantoms and determination of the absorption and scattering coefficients showed excellent agreement with theory for wavelengths were the user inputted single g-value was sufficiently precise. Future improvements entail providing for multi-wavelength g-value entry to extend the accuracy of results to encompass the complete system multispectral range. Ultimately, the data collection process and algorithms developed through this effort will be used to study actual biological tissues for the purpose of deriving and refining models for light-tissue interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Metallic-like photoluminescence and absorption in fused silica surface flaws

Using high-sensitivity confocal time-resolved photoluminescence (PL) techniques, we report an ultra-fast PL (40ps-5ns) from impurity-free surface flaws on fused silica, including polished, indented or fractured surfaces of fused silica, and from laser-heated evaporation pits. This PL is excited by the single photon absorption of sub-band gap light, and is especially bright in fractures. Regions which exhibit this PL are strongly absorptive well below the band gap, as evidenced by a propensity to damage with 3.5eV ns-scale laser pulses.

36 MATERIALS SCIENCE↗

Reactivity of Chromium(III) Nutritional Supplements in Biological Media: An X-Ray Absorption Spectroscopic Study

Chromium(III) nutritional supplements are widely used due to their purported ability to enhance glucose metabolism, despite growing evidence on low activity and the potential genotoxicity of these compounds. Reactivities of Cr(III) complexes used in nutritional formulations, including [Cr3O(OCOEt)6(OH2)3]+ (A), [Cr(pic)3] (pic) = 2-pyridinecarboxylato(-) (B), and trans-[CrCl2(OH2)4]+ (CrCl3 {center_dot} 6H2O; C), in a range of natural and simulated biological media (artificial digestion systems, blood and its components, cell culture media, and intact L6 rat skeletal muscle cells) were studied by X-ray absorption near-edge structure (XANES) spectroscopy. The XANES spectroscopic data were processed by multiple linear-regression analyses with the use of a library of model Cr(III) compounds, and the results were corroborated by the results of X-ray absorption fine structure spectroscopy and electrospray mass spectrometry. Complexes A and B underwent extensive ligand-exchange reactions under conditions of combined gastric and intestinal digestion (in the presence of a semisynthetic meal, 3 h at 310 K), as well as in blood serum and in a cell culture medium (1-24 h at 310 K), with the formation of Cr(III) complexes with hydroxo and amino acid/protein ligands. Reactions of compounds A-C with cultured muscle cells led to similar ligand-exchange products, with at least part of Cr(III) bound to the surface of the cells. The reactions of B with serum greatly enhanced its propensity to be converted to Cr(VI) by biological oxidants (H2O2 or glucose oxidase system), which is proposed to be a major cause of both the insulin-enhancing activity and toxicity of Cr(III) compounds (Mulyani, I.; Levina, A.; Lay, P. A. Angew. Chem. Int. Ed. 2004, 43, 4504-4507). This finding enhances the current concern over the safety of consumption of large doses of Cr(III) supplements, particularly [Cr(pic)3].

59 BASIC BIOLOGICAL SCIENCES↗

Covalency Trends in Group IV Metallocene Dichlorides. Chlorine K-Edge X-Ray Absorption Spectroscopy And Time Dependent-Density Functional Theory

For 3-5d transition-metal ions, the (C{sub 5}R{sub 5}){sub 2}MCl{sub 2} (R = H, Me for M = Ti, Zr, Hf) bent metallocenes represent a series of compounds that have been central in the development of organometallic chemistry and homogeneous catalysis. Here, we evaluate how changes in the principal quantum number for the group IV (C{sub 5}H{sub 5}){sub 2}MCl{sub 2} (M = Ti, Zr, Hf; 1-3, respectively) complexes affects the covalency of M-Cl bonds through application of Cl K-edge X-ray Absorption Spectroscopy (XAS). Spectra were recorded on solid samples dispersed as a thin film and encapsulated in polystyrene matrices to reliably minimize problems associated with X-ray self-absorption. The data show that XAS pre-edge intensities can be quantitatively reproduced when analytes are encapsulated in polystyrene. Cl K-edge XAS data show that covalency in M-Cl bonding changes in the order Ti > Zr > Hf and demonstrates that covalency slightly decreases with increasing principal quantum number in 1-3. The percent Cl 3p character was experimentally determined to be 26, 23, and 18% per M-Cl bond in the thin-film samples for 1-3 respectively and was indistinguishable from the polystyrene samples, which analyzed as 25, 25, and 19% for 1-3, respectively. To aid in interpretation of Cl K-edge XAS, 1-3 were also analyzed by ground-state and time-dependent density functional theory (TD-DFT) calculations. The calculated spectra and percent chlorine character are in close agreement with the experimental observations, and show 20, 18, and 17% Cl 3p character per M-Cl bond for 1-3, respectively. Polystyrene matrix encapsulation affords a convenient method to safely contain radioactive samples to extend our studies to include actinide elements, where both 5f and 6d orbitals are expected to play a role in M-Cl bonding and where transition assignments must rely on accurate theoretical calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-Ray Absorption Spectroscopy As a Probe of Microbial Sulfur Biochemistry: the Nature of Bacterial Sulfur Globules Revisited

The chemical nature of the sulfur in bacterial sulfur globules has been the subject of controversy for a number of years. Sulfur K-edge X-ray absorption spectroscopy (XAS) is a powerful technique for probing the chemical forms of sulfur in situ, but two groups have used it with very different conclusions. The root of the controversy lies with the different detection strategies used by the two groups, which result in very different spectra. This paper seeks to resolve the controversy. We experimentally demonstrate that the use of transmittance detection for sulfur K-edge XAS measurements is highly prone to spectroscopic distortions and that much of the published work on sulfur bacteria is very likely based on distorted data. We also demonstrate that all three detection methods used for X-ray absorption experiments yield essentially identical spectra when the measurements are carried out under conditions where no experimental distortions are expected. Finally, we turn to the original question--the chemical nature of bacterial sulfur. We examine isolated sulfur globules of Allochromatium vinosum and intact cells of a strain of magnetotactic coccus and show that XAS indicates the presence of a chemical form of sulfur resembling S{sub 8}.

59 BASIC BIOLOGICAL SCIENCES↗

X-Ray Absorption Fine Structure Spectroscopic Studies of Octakis(DMSO)Lanthanoid(III) Complexes in Solution And in the Solid Iodides

Octakis(DMSO)lanthanoid(III) iodides (DMSO = dimethylsulfoxide), [Ln(OS(CH{sub 3}){sub 2}){sub 8}]I{sub 3}, of most lanthanoid(III) ions in the series from La to Lu have been studied in the solid state and in DMSO solution by extended X-ray absorption fine structure (EXAFS) spectroscopy. L{sub 3}-edge and also some K-edge spectra were recorded, which provided mean Ln-O bond distances for the octakis(DMSO)lanthanoid(III) complexes. The agreement with the average of the Ln-O bond distances obtained in a separate study by X-ray crystallography was quite satisfactory. The crystalline octakis(DMSO)lanthanoid(III) iodide salts have a fairly broad distribution of Ln-O bond distances, ca. 0.1 {angstrom}, with a few disordered DMSO ligands. Their EXAFS spectra are in excellent agreement with those obtained for the solvated lanthanoid(III) ions in DMSO solution, both of which show slightly asymmetric distributions of the Ln-O bond distances. Hence, all lanthanoid(III) ions are present as octakis(DMSO)lanthanoid(III) complexes in DMSO solution, with the mean Ln-O distances centered at 2.50 (La), 2.45 (Pr), 2.43 (Nd), 2.41 (Sm), 2.40 (Eu), 2.39 (Gd), 2.37 (Tb), 2.36 (Dy), 2.34 (Ho), 2.33 (Er), 2.31 (Tm), and 2.29 {angstrom} (Lu). This decrease in the Ln-O bond distances is larger than expected from the previously established ionic radii for octa-coordination. This indicates increasing polarization of the Ln{sup III}-O(DMSO) bonds with increasing atomic number. However, the S(1s) electron transition energies in the sulfur K-edge X-ray absorption near-edge structure (XANES) spectra, probing the unoccupied molecular orbitals of lowest energy of the DMSO ligands for the [Ln(OS(CH{sub 3}){sub 2}){sub 8}]{sup 3+} complexes, change only insignificantly from Ln = La to Lu. This indicates that there is no appreciable change in the ?-contribution to the S-O bond, probably due to a corresponding increase in the contribution from the sulfur lone pair to the bonding.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗