Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

High-Power Impulse Magnetron Sputter Deposition of Boron Carbide with Full-Face Erosion Magnetron and Mixed Ar-Ne Plasma

Boron carbide (B 4 C) is an attractive inertial confinement fusion ablator material. The fabrication of B4C ablators by magnetron sputtering requires process optimization. To increase process flexibility, here we explore high-power impulse magnetron sputter (HiPIMS) deposition of B 4 C in pure Ar and mixed Ar-Ne plasmas. Here, the results show that higher plasma discharge currents can be reached with a mixed Ar-Ne plasma in the entire working pressure range studied (5 𝑡𝑜 50 mTorr). At 45 mTorr with 10% of Ne in the Ar-Ne mix, high peak target current densities of ~1 A cm −2 were demonstrated. Films deposited with such a mixed Ar-Ne plasma with a full-face erosion magnetron source on substrates biased at −25 V exhibited higher density and improved mechanical properties, albeit with higher compressive residual stresses compared to the case of HiPIMS deposition in a pure Ar plasma. This work demonstrates additional process flexibility of the HiPIMS discharge mode for the deposition of B 4 C coatings.

Ablator capsule↗

Radar detectability studies of slow and small zodiacal dust cloud particles. I. The case of Arecibo 430 MHz meteor head echo observations

Recent model development of the Zodiacal Dust Cloud (ZDC) argues that the incoming flux of meteoric material into the Earth's upper atmosphere is mostly undetected by radars because they cannot detect small extraterrestrial particles entering the atmosphere at low velocities due to the relatively small production of electrons. In this paper, we present a new methodology utilizing meteor head echo radar observations that aims to constrain the ZDC physical model by ground-based measurements. In particular, for this work, we focus on Arecibo 430 MHz observations since this is the most sensitive radar utilized for this type of observations to date. For this, we integrate and employ existing comprehensive models of meteoroid ablation, ionization, and radar detection to enable accurate interpretation of radar observations and show that reasonable agreement in the hourly rates is found between model predictions and Arecibo observations when (1) we invoke the lower limit of the model predicted flux (∼16 t d{sup –1}) and (2) we estimate the ionization probability of ablating metal atoms using laboratory measurements of the ionization cross sections of high-speed metal atom beams, resulting in values up to two orders of magnitude lower than the extensively utilized figure reported by Jones for low-speed meteors. However, even at this lower limit, the model overpredicts the slow portion of the Arecibo radial velocity distributions by a factor of three, suggesting that the model requires some revision.

79 ASTRONOMY AND ASTROPHYSICS↗

Analytical formula for pellet fuel source density in toroidal plasma configurations based on an areal deposition model

An analytical formula for the fuel source density η F (Ψ) over a magnetic flux surface Ψ following pellet injection is derived. During pellet motion the ablated and ionized fuel will be initially deposited nearby the pellet, prior to subsequent homogenization within the magnetic flux surfaces. Here in our research, it is assumed that the deposition area projected normal to the magnetic field is on the order of the cross-sectional area of the ionized ablation column whose axis is aligned with the magnetic field. Previous pellet deposition codes [1] employed a point source deposition approximation, which overpredicts the surface-averaged density, particularly when the obliquity between the pellet trajectory and the flux surface normal approaches 90 degrees. A key finding of this study is that as the obliquity approaches 90 degrees, grazing trajectory, the areal model predicts a well behaved η F and removes the unphysical divergence stemming from the point model. To illustrate the difference exhibited between areal and point models for near grazing trajectories, we considered vertical pellet injection into a CFETR-like tokamak with a negative triangularity plasma cross section using a pellet ablation/deposition module.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diffusion, thermalization, and optical pumping of YbF molecules in a cold buffer-gas cell

We produce YbF molecules with a density of 10{sup 18} m{sup -3} using laser ablation inside a cryogenically cooled cell filled with a helium buffer gas. Using absorption imaging and absorption spectroscopy we study the formation, diffusion, thermalization, and optical pumping of the molecules. The absorption images show an initial rapid expansion of molecules away from the ablation target followed by a much slower diffusion to the cell walls. We study how the time constant for diffusion depends on the helium density and temperature and obtain values for the YbF-He diffusion cross section at two different temperatures. We measure the translational and rotational temperatures of the molecules as a function of time since formation, obtain the characteristic time constant for the molecules to thermalize with the cell walls, and elucidate the process responsible for limiting this thermalization rate. Finally, we make a detailed study of how the absorption of the probe laser saturates as its intensity increases, showing that the saturation intensity is proportional to the helium density. We use this to estimate collision rates and the density of molecules in the cell.

74 ATOMIC AND MOLECULAR PHYSICS↗

Structural Preablation Dynamics of Graphite Observed by Ultrafast Electron Crystallography

By means of time-resolved electron crystallography, we report direct observation of the structural dynamics of graphite, providing new insights into the processes involving coherent lattice motions and ultrafast graphene ablation. When graphite is excited by an ultrashort laser pulse, the excited carriers reach their equilibrium in less then one picosecond by transferring heat to a subset of strongly coupled optical phonons. The time-resolved diffraction data show that on such a time scale the crystal undergoes a contraction whose velocity depends on the excitation fluence. The contraction is followed by a large expansion which, at sufficiently high fluence, leads to the ablation of entire graphene layers, as recently predicted theoretically.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray diffuse scattering measurements of nucleation dynamics at femtosecond resolution.

Femtosecond time-resolved small and wide angle x-ray diffuse scattering techniques are applied to investigate the ultrafast nucleation processes that occur during the ablation process in semiconducting materials. Following intense optical excitation, a transient liquid state of high compressibility characterized by large-amplitude density fluctuations is observed and the buildup of these fluctuations is measured in real time. Small-angle scattering measurements reveal snapshots of the spontaneous nucleation of nanoscale voids within a metastable liquid and support theoretical predictions of the ablation process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectroscopic Characterization of Plasmoid Properties During Pellet Fueling in W7-X

This study utilizes a spectroscopic approach to investigate the properties of plasmoids that are formed during the process of cryogenic hydrogen pellet fueling in the Wendelstein 7-X (W7-X) stellarator. An analysis of the Balmer series emissions was conducted using a diagnostic that was installed during the 2024 operational campaign. Electron temperature, density, and plasma beta ( β ) values can be inferred from the emissions of radiation from the ablation plasmoid. These values are essential for validating pellet ablation models and, in the future, optimizing fueling strategies in steady-state fusion devices.

Cryogenic hydrogen pellets↗

Three-dimensional tracking of cardiac catheters using an inverse geometry x-ray fluoroscopy system

Purpose: Scanning beam digital x-ray (SBDX) is an inverse geometry fluoroscopic system with high dose efficiency and the ability to perform continuous real-time tomosynthesis at multiple planes. This study describes a tomosynthesis-based method for 3D tracking of high-contrast objects and present the first experimental investigation of cardiac catheter tracking using a prototype SBDX system. Methods: The 3D tracking algorithm utilizes the stack of regularly spaced tomosynthetic planes that are generated by SBDX after each frame period (15 frames/s). Gradient-filtered versions of the image planes are generated, the filtered images are segmented into object regions, and then a 3D coordinate is calculated for each object region. Two phantom studies of tracking performance were conducted. In the first study, an ablation catheter in a chest phantom was imaged as it was pulled along a 3D trajectory defined by a catheter sheath (10, 25, and 50 mm/s pullback speeds). SBDX tip tracking coordinates were compared to the 3D trajectory of the sheath as determined from a CT scan of the phantom after the registration of the SBDX and CT coordinate systems. In the second study, frame-to-frame tracking precision was measured for six different catheter configurations as a function of image noise level (662-7625 photons/mm{sup 2} mean detected x-ray fluence at isocenter). Results: During catheter pullbacks, the 3D distance between the tracked catheter tip and the sheath centerline was 1.0{+-}0.8 mm (mean {+-}one standard deviation). The electrode to centerline distances were comparable to the diameter of the catheter tip (2.3 mm), the confining sheath (4 mm outside diameter), and the estimated SBDX-to-CT registration error ({+-}0.7 mm). The tip position was localized for all 332 image frames analyzed and 83% of tracked positions were inside the 3D sheath volume derived from CT. The pullback speeds derived from the catheter trajectories were within 5% of the programed pullback speeds. The tracking precision of ablation and diagnostic catheter tips ranged from {+-}0.2 mm at the highest image fluence to {+-}0.9 mm at the lowest fluence. Tracking precision depended on image fluence, the size of the tracked catheter electrode, and the contrast of the electrode. Conclusions: High speed multiplanar tomosynthesis with an inverse geometry x-ray fluoroscopy system enables 3D tracking of multiple high-contrast objects at the rate of fluoroscopic imaging. The SBDX system is capable of tracking electrodes in standard cardiac catheters with approximately 1 mm accuracy and precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-161: Inverse Problems for Optical Parameters in Laser Induced Thermal Therapy

Purpose: Magnetic resonance-guided laser-induced thermal therapy (MRgLITT) is investigated as a neurosurgical intervention for oncological applications throughout the body by active post market studies. Real-time MR temperature imaging is used to monitor ablative thermal delivery in the clinic. Additionally, brain MRgLITT could improve through effective planning for laser fiber's placement. Mathematical bioheat models have been extensively investigated but require reliable patient specific physical parameter data, e.g. optical parameters. This abstract applies an inverse problem algorithm to characterize optical parameter data obtained from previous MRgLITT interventions. Methods: The implemented inverse problem has three primary components: a parameter-space search algorithm, a physics model, and training data. First, the parameter-space search algorithm uses a gradient-based quasi-Newton method to optimize the effective optical attenuation coefficient, μ-eff. A parameter reduction reduces the amount of optical parameter-space the algorithm must search. Second, the physics model is a simplified bioheat model for homogeneous tissue where closed-form Green's functions represent the exact solution. Third, the training data was temperature imaging data from 23 MRgLITT oncological brain ablations (980 nm wavelength) from seven different patients. Results: To three significant figures, the descriptive statistics for μ-eff were 1470 m{sup −1} mean, 1360 m{sup −1} median, 369 m{sup −1} standard deviation, 933 m{sup −1} minimum and 2260 m{sup −1} maximum. The standard deviation normalized by the mean was 25.0%. The inverse problem took <30 minutes to optimize all 23 datasets. Conclusion: As expected, the inferred average is biased by underlying physics model. However, the standard deviation normalized by the mean is smaller than literature values and indicates an increased precision in the characterization of the optical parameters needed to plan MRgLITT procedures. This investigation demonstrates the potential for the optimization and validation of more sophisticated bioheat models that incorporate the uncertainty of the data into the predictions, e.g. stochastic finite element methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-04: Integration of Interstitial High Intensity Therapeutic Ultrasound Applicators On a Clinical MRI-Guided High Intensity Focused Ultrasound Treatment Planning Software Platform

Purpose: Interstitial high intensity therapeutic ultrasound (HITU) applicators can be used to ablate tissue percutaneously, allowing for minimally-invasive treatment without ionizing radiation [1,2]. The purpose of this study was to evaluate the feasibility and usability of combining multielement interstitial HITU applicators with a clinical magnetic resonance imaging (MRI)-guided focused ultrasound software platform. Methods: The Sonalleve software platform (Philips Healthcare, Vantaa, Finland) combines anatomical MRI for target selection and multi-planar MRI thermometry to provide real-time temperature information. The MRI-compatible interstitial US applicators (Acoustic MedSystems, Savoy, IL, USA) had 1–4 cylindrical US elements, each 1 cm long with either 180° or 360° of active surface. Each applicator (4 Fr diameter, enclosed within a 13 Fr flexible catheter) was inserted into a tissue-mimicking agar-silica phantom. Degassed water was circulated around the transducers for cooling and coupling. Based on the location of the applicator, a virtual transducer overlay was added to the software to assist targeting and to allow automatic thermometry slice placement. The phantom was sonicated at 7 MHz for 5 minutes with 6–8 W of acoustic power for each element. MR thermometry data were collected during and after sonication. Results: Preliminary testing indicated that the applicator location could be identified in the planning images and the transducer locations predicted within 1 mm accuracy using the overlay. Ablation zones (thermal dose ≥ 240 CEM43) for 2 active, adjacent US elements ranged from 18 mm × 24 mm (width × length) to 25 mm × 25 mm for the 6 W and 8 W sonications, respectively. Conclusion: The combination of interstitial HITU applicators and this software platform holds promise for novel approaches in minimally-invasive MRI-guided therapy, especially when bony structures or air-filled cavities may preclude extracorporeal HIFU.[1] Diederich et al. IEEE UFFFC 46.5 (1999): 1218.[2] Chopra et al. PMB 50.21 (2005): 4957. Funding support was provided by Philips Healthcare and in-kind support from Acoustic MedSystems Inc. Ari Partanen is a paid employee of Philips Healthcare. Goutam Ghoshal and Everette Clif Burdette are paid employees of Acoustic MedSystems Inc.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-09: Quantification of Nanoparticle Heating and Concentration for MR-Guided Laser Interstitial Thermal Therapy

Purpose: Nanoparticle Mediated Laser Interstitial Thermal Therapy (npLITT) is a technique that utilizes tumor localized optically activated nanoparticles to increase the conformality of laser ablation procedures. Temperatures in these procedures are dependent on the particle concentration which generally cannot be measured noninvasively prior to therapy. In this work we attempt to quantify particle concentration in vivo by estimating the increase in R2* relaxation induced by bifunctional magnetic resonance (MR)-visible gold-based nanoparticles (SPIO@Au) and relate it to the temperature increase observed during real time MR temperature imaging (MRTI) of laser ablation. Methods: SPIO@Au nanoparticles (90nm) were synthesized containing a silica-iron core (for MR visibility via R2*) and gold shell (for near-infrared absorption). High resolution R2* maps were acquired before and after injecting four different particle concentrations (saline,1e10, 5e10, and 10e10 particles/mL) into HN5 flank xenografts. Tumors were monitored using MRTI during treatment with an interstitial fiber. (1 watt, 808 nm, 3 minutes) Results: The maximum temperature within the tumors increased linearly with concentration of injected particles, reaching 34.0, 37.6, 45.8, and 55.4 {sup 0}C for saline, 1e10, 5e10 and 10e10 particles/mL injections, respectively (R2=.994). The highest temperatures occur at the injection site rather than the fiber, confirming that SPIO@Au nanoparticles are the primary absorber. The differences between the median R2* measured at the injection site and the rest of the tumor were −6, 134, 111, 156 s-1 for the saline,1e10,5e10 and 10e10 particles/mL injections, respectively. This R2* change is consistent with the measured relaxivity for the 1e10 particles/mL injection but does not maintain linearity at higher concentrations. Conclusion: Bifunctional SPIO@Au nanoparticles are a promising technology for providing noninvasive estimates of particle concentration via MRI and temperature increase in npLITT procedures. Future experiments will focus on lower, physiologically relevant particle concentrations and spin echo R2 mapping to better quantify the particle concentration. This research was supported by the National Institutes of Health and National Cancer Institute under Award Numbers TL1TR000369 and P30CA016672 and was conducted at the MD Anderson Center for Advanced Biomedical Imaging in-part with equipment support from General Electric Healthcare.

60 APPLIED LIFE SCIENCES↗

Methods for Modifications of Harmonic Spectra from Laser-Produced Plasmas

We review the studies of the modifications of harmonic spectra from laser-produced plasmas. The substantial spectral broadening and blue shift of the harmonics generating in the laser plasma during transformation of the spectrum of the laser radiation formed the filaments upon passage of femtosecond pulses through the argon gas is analyzed. We also discuss the studies of harmonic spectra variations that occur as a result of the passage of the laser pulses through the carbon- and metal-containing plasmas at the variable density of ablated species and intensity of driving pulse. To show other type of modulation of harmonic emission spectra, the plasmas containing the small molecules of silver produced during ablation of the bulk silver and silver nanoparticles at the conditions suitable for efficient harmonic generation of the ultrashort pulses propagating through the laser-produced plasmas were analyzed. The time-of-flight mass-spectroscopy studies of plasmas confirmed the presence of these species in plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Jet formation in spallation of metal film from substrate under action of femtosecond laser pulse

It is well known that during ablation by an ultrashort laser pulse, the main contribution to ablation of the substance is determined not by evaporation, but by the thermomechanical spallation of the substance. For identical metals and pulse parameters, the type of spallation is determined by film thickness d{sub f}. An important gauge is metal heating depth d{sub T} at the two-temperature stage, at which electron temperature is higher than ion temperature. We compare cases with d{sub f} < d{sub T} (thin film) and d{sub f} ≫ d{sub T} (bulk target). Radius R{sub L} of the spot of heating by an optical laser is the next (after d{sub f}) important geometrical parameter. The morphology of film bulging in cases where d{sub f} < d{sub T} on the substrate (blistering) changes upon a change in radius R{sub L} in the range from diffraction limit R{sub L} ∼ λ to high values of R{sub L} ≫ λ, where λ ∼ 1 μm is the wavelength of optical laser radiation. When d{sub f} < d{sub T}, R{sub L} ∼ λ, and F{sub abs} > F{sub m}, gold film deposited on the glass target acquires a cupola-shaped blister with a miniature frozen nanojet in the form of a tip on the circular top of the cupola (F{sub abs} and F{sub m} are the absorbed energy and the melting threshold of the film per unit surface area of the film). A new physical mechanism leading to the formation of the nanojet is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulations of plasma behavior during pellet injection in ITER

Plasma behavior during pellet injection in ITER is investigated using a 1.5D BALDUR integrated predictive modeling code. In these simulations, the pellet ablation is described using the neutral gas shielding (NGS) model developed by Parks and Turnbull [Phys. Fluids 21, 1735 (1978)]. The NGS pellet ablation model that includes the {nabla}B drift effect is coupled with a plasma core transport model, which is a combination of an MMM95 anomalous transport model and an NCLASS neoclassical transport model. The combination of core transport models, together with pellet model, is used to simulate the time evolution of plasma current, ion and electron temperatures, and density profiles for ITER standard type-I ELMy H-mode discharges during the pellet injection. It is found that the injection of pellet can result in either enhancement or degradation of plasma performance. The {nabla}B drift effect on the pellet deposition is very strong in ITER. The plasma density with high field side pellets, which favorable with the {nabla}B drift effect, is much higher and pellet can penetrate much deeper than that with low field side pellets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of a brass alloy concentration composition using calibration-free laser-induced breakdown spectroscopy

Laser-induced breakdown spectroscopy (LIBS) is a technique that can provide qualitative and quantitative measurements of the characteristics of irradiated metals. In the present work, we have calculated the parameters of the plasma produced from a brass alloy sample under the action of a pulsed Nd: YAG laser operating at 1064 nm. The emission lines of copper atoms (Cu I), zinc atoms (Zn I), and lead atoms (Pb I), which are elements of a brass alloy composition, were used to investigate the parameters of the brass plasma. The spectral profiles of Cu, Zn, and Pb lines have been used to extract the electron temperature and density of the brass alloy plasma. The characteristics of Cu, Zn, and Pb were determined quantatively by the calibration-free LIBS (CF-LIBS) method considering for accurate analysis that the laser-induced ablated plasma is optically thin in local thermodynamic equilibrium conditions and the plasma ablation is stoichiometric. The Boltzmann plot method was used to evaluate the plasma temperature, and the Stark broadened profiles were used to determine the electron density. An algorithm based on the experimentally measured values of the intensity of spectral lines and the basic laws of plasma physics was developed for the determination of Cu, Zn, and Pb concentrations in the brass sample. The concentrations C{sub CF-LIBS} calculated by CF-LIBS and the certified concentrations C{sub certified} were very close.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrical Conductivity and Barrier Properties of Lithium Niobate Thin Films

The thin-film structures made of LiNbO{sub 3} and obtained via laser ablation and magnetron sputtering are studied with volt-farad and volt-ampere characteristics. A potential barrier on the Si–LiNbO{sub 3} interface was found for both types of the films with the capacitance-voltage characteristics. The current-voltage characteristics showed that there are several conduction mechanisms in the structures studied. The Poole–Frenkel effect and the currents limited by a space charge mainly contribute to the electrical conductivity in the LiNbO{sub 3} film produced with the laser ablation method. The currents limited by a space charge contribute to the main mechanism in the film heterostructure obtained with the magnetron sputtering method.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-dependent single and double pulse laser-induced breakdown spectroscopy of chromium in liquid

A study of aqueous solutions of chromium using single and double pulse laser-induced breakdown spectroscopy (LIBS) is presented. Three atomic emission lines show enhancement in emission under dual pulse LIBS excitation. The temporal evolution of line emission indicates that a shock wave front produced by the first laser pulse plays an important role in determining the decay rate of intensity by excitation transfer in single pulse LIBS and by plasma confinement in double pulse LIBS. The ratio of emission in dual pulse LIBS to single pulse LIBS with time shows a linear increase followed by the onset of saturation. A theoretical calculation of the enhancement is found to be in qualitative agreement with the experimental results, suggesting that material ablation in dual pulse LIBS should be {>=}3.5 times that of single pulse LIBS. There is indication that the increase in ablation and subsequent enhancement in emission may be due to the rarefied gas density inside the region enclosed by the shock wave produced by the first laser pulse. The limit of detection of Cr in aqueous solution has been improved by an order of magnitude with double pulse LIBS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrafast thin-film laser-induced breakdown spectroscopy of doped oxides

Single-shot femtosecond laser induced breakdown spectroscopy (LIBS) has been shown to be an effective means of detecting heavy metal dopants in porous thin films. Traditional LIBS analysis of trace dopants in modern painted surfaces or TiO2 films is difficult due to the broad noisy spectra of the titanium constituent and interference due to the substrate material. Femtosecond laser pulses provide excellent ablation of the target material with little damage to the underlying substrate. In this study a Ti:sapphire femtosecond laser pulse operated at 800 and 266 nm wavelengths and an Nd:YAG nanosecond laser operated at 266 nm were used to ablate 0.15-15 {mu}m films of TiO2 doped with varying amounts of MgO. This application shows excellent detection of Mg down to 60 ppm with little interference by the substrate material.

36 MATERIALS SCIENCE↗