Status of the variable diameter centerbody inlet program

The Variable Diameter Centerbody (VDC) inlet is an ongoing research program at LeRC. The VDC inlet is a mixed compression, axisymmetric inlet that has potential application on the next generation supersonic transport. This inlet was identified as one of the most promising axisymmetric concepts for supersonic cruise aircraft during the SCAR program in the late 1970's. Some of its features include high recovery, low bleed, good angle-of-attack tolerance, and excellent engine airflow matching. These features were demonstrated at LeRC in the past by the design and testing of fixed hardware models. A current test program in the LeRC 10' x 10' Supersonic Wind Tunnel (SWT) will attempt to duplicate these features on model hardware that actually incorporates a flight-like variable diameter centerbody mechanism.

Saunders, John D.↗

Giovanni-4: The Next Generation

This talk discusses the new aspects of Giovanni-4. Covered in the talk are new features in Giovanni-4, including shape fileservices, seasonal analysis services, the Omnibus Portal, navigation among variables, and comparison services.

analysis↗

Solution of Poisson equations for 3-dimensional grid generations

A method for generating three dimensional, finite difference grids about complicated geometries by using Poisson equations is developed. The inhomogenous terms are automatically chosen such that orthogonality and spacing restrictions at the body surface are satisfied. Spherical variables are used to avoid the axis singularity, and an alternating-direction-implicit (ADI) solution scheme is used to accelerate the computations. Computed results are presented that show the capability of the method. Since most of the results presented have been used as grids for flow-field computations, this is indicative that the method is a useful tool for generating three-dimensional grids about complicated geometries.

Fujii, K.↗

Modeling Spatial Distribution of Snow Water Equivalent by Combining Meteorological and Satellite Data with Lidar Maps

Abstract An accurate characterization of the water content of snowpack, or snow water equivalent (SWE), is necessary to quantify water availability and constrain hydrologic and land surface models. Recently, airborne observations (e.g., lidar) have emerged as a promising method to accurately quantify SWE at high resolutions (scales of ∼100 m and finer). However, the frequency of these observations is very low, typically once or twice per season in the Rocky Mountains of Colorado. Here, we present a machine learning framework that is based on random forests to model temporally sparse lidar-derived SWE, enabling estimation of SWE at unmapped time points. We approximated the physical processes governing snow accumulation and melt as well as snow characteristics by obtaining 15 different variables from gridded estimates of precipitation, temperature, surface reflectance, elevation, and canopy. Results showed that, in the Rocky Mountains of Colorado, our framework is capable of modeling SWE with a higher accuracy when compared with estimates generated by the Snow Data Assimilation System (SNODAS). The mean value of the coefficient of determination R 2 using our approach was 0.57, and the root-mean-square error (RMSE) was 13 cm, which was a significant improvement over SNODAS (mean R 2 = 0.13; RMSE = 20 cm). We explored the relative importance of the input variables and observed that, at the spatial resolution of 800 m, meteorological variables are more important drivers of predictive accuracy than surface variables that characterize the properties of snow on the ground. This research provides a framework to expand the applicability of lidar-derived SWE to unmapped time points. Significance Statement Snowpack is the main source of freshwater for close to 2 billion people globally and needs to be estimated accurately. Mountainous snowpack is highly variable and is challenging to quantify. Recently, lidar technology has been employed to observe snow in great detail, but it is costly and can only be used sparingly. To counter that, we use machine learning to estimate snowpack when lidar data are not available. We approximate the processes that govern snowpack by incorporating meteorological and satellite data. We found that variables associated with precipitation and temperature have more predictive power than variables that characterize snowpack properties. Our work helps to improve snowpack estimation, which is critical for sustainable management of water resources.

54 ENVIRONMENTAL SCIENCES↗

Predictability of the early summer surface air temperature over Western South Asia

Variability of the Surface Air Temperature (SAT) over the Western South Asia (WSA) region leads to frequent heatwaves during the early summer (May-June) season. The present study uses the European Centre for Medium-Range Weather Forecast’s fifth-generation seasonal prediction system, SEAS5, from 1981 to 2022 based on April initial conditions (1-month lead) to assess the SAT predictability during early summer season. The goal is to evaluate the SEAS5’s ability to predict the El Niño-Southern Oscillation (ENSO) related interannual variability and predictability of the SAT over WSA, which is mediated through upper-level (200-hPa) geopotential height anomalies. This teleconnection leads to anomalously warm surface conditions over the region during the negative ENSO phase, as observed in the reanalysis and SEAS5. We evaluate SEAS5 prediction skill against two observations and three reanalyses datasets. The SEAS5 SAT prediction skill is higher with high spatial resolution observations and reanalysis datasets compared to the ones with low-resolution. Overall, SEAS5 shows reasonable skill in predicting SAT and its variability over the WSA region. Moreover, the predictability of SAT during La Niña is comparable to El Niño years over the WSA region.

54 ENVIRONMENTAL SCIENCES↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

A simple way to integrate distributed storage into a wholesale electricity market

Abstract Current plans to decarbonize the electric supply system imply that the generation from wind and solar sources will grow substantially. This growth will increase the uncertainty of system operations due to the inherent variability of these renewable sources, and as a result, more reserve capacity will be required to provide the ramping (flexibility) needed for reliable operations. This paper assumes that all of the increased uncertainty comes from wind farms on the grid, and it shows how distributed storage managed locally by aggregators can provide the ramping needed without introducing a separate market for flexibility. This can be accomplished when the aggregators minimize the expected daily cost of the energy purchased from the grid for their customers by submitting optimal bids into the wholesale market with high and low price thresholds for discharging and charging the storage. This model is illustrated using a stochastic multi-period security constrained optimal power flow together with realistic data for a reduction of the network in the Northeast Power Coordinating Council region of the United States. The results show that the bidding strategy for distributed storage provides ramping to the grid just as effectively as storage managed by a system operator.

Lamadrid, Alberto J.↗

Decontamination of urban surfaces contaminated with radioactive materials and consequent onsite recycling of the waste water

Enhancing rapid remediation strategies is paramount for recovery after a large-scale nuclear contamination event in an urban environment. Some current strategies recommend use of readily available equipment, materials, and facilities to expedite recovery. For example, applying pressurized water to contaminated surfaces may effectively remove radioactive contamination. In this study, a commercial power washer removes soluble forms of 152 Eu 3 + , 85 Sr 2 + , and 137 Cs + contamination from common porous building materials, and computer simulations characterize the recycling of the resultant contaminated wash water. Pressure washing the porous building materials under spray conditions typical with do-it-yourself units improved decontamination factors (DFs) for 152 Eu compared to low-pressure application of tap water (majority of two-tailed t-test p-values < 0.1), but pressure did not improve DFs for 137 Cs or 85 Sr. For both pressurized and low-pressure applications, adding potassium ions (K + ) to promote ion exchange reactions produced significantly higher DFs for tested radionuclides on asphalt, brick, and concrete. The resultant contaminated wash water can be processed through self-prepared chemical filtration beds of clay and sand. Modeled in a prior study, the beds yielded linear trends (R 2 > 0.98) in sensitivity analyses between most bed configuration variables and bed performance variables, permitting flexible ad-hoc bed design. The experimental and simulation results led to estimates of the remediation rate and waste generated after cleaning 250 m 2 of cesium-contaminated concrete from the combined deployment of a power washer and two different mobile treatment beds. Furthermore, the first treatment bed was designed to reduce treatment time and processed 1900 L of wash solution in 70 min using 880 kg of clay/sand infill material. Designed to reduce the solid waste generated, the second bed processed the same solution volume in 1040 min (17 h) using 170 kg of clay/sand infill material. The results of this analysis warrant further investigation of power washing with recycled salt solution as an effective rapid decontamination method with manageable waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High temporal resolution generation expansion planning for the clean energy transition

As power systems integrate increasing quantities of wind, solar and energy storage resources, it is important to revisit power system capacity expansion modeling methods and assumptions that have been utilized in thermal- dominated systems. We conduct a series of case study analyses using a simplified representation of the Electric Reliability Council of Texas (ERCOT) system to demonstrate how least-cost capacity expansion outcomes are impacted by changes in model resolution across two temporal dimensions: 1) the number of considered representative periods, and 2) the system dispatch interval. First, we find that the least-cost generation portfolio can differ significantly for small changes in the number of representative days, but largely converges to the 365-day result once 104 representative days are considered. Furthermore, systems with wind, solar and storage resources were more sensitive to changes in the number of representative days than a thermal-dominated system. Second, we find that considering five-minute dispatch resolution consistently results in least-cost generation portfolios with less solar capacity and more energy storage capacity than corresponding scenarios with hourly dispatch intervals. This suggests that hourly dispatch representation fails to capture the intra-hour volatility of solar generation, and therefore also overlooks opportunities for storage resources to provide system value by balancing this volatility. Collectively these results indicate that capacity expansion modelers should revisit conventional approaches to temporal representation when conducting analyses of deeply decarbonized power systems to ensure that such analyses are robust and actionable. To our knowledge, this is the first study to analyze capacity expansion outcomes with five-minute dispatch resolution in this manner.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Load Matching Potential of Urban Renewables during Extreme Heat in New York City

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on the matter by assessing the feasibility of using offshore wind and rooftop photovoltaic systems to meet electricity demand during a period of thermal stress in New York City—August 2019. A unified modelling framework, based on the Urbanized Weather Research and Forecasting model, is used to simulate climate, renewable resources and energy demand variables. Findings show significant energy load miss-match, ranging from 3 to 5 GW, between the demand and the composite renewable generation outcome. This study provides a transferable framework for evaluating renewable integration in dense urban regions and highlights the need for additional strategies to support grid resilience during extreme heat events, while clarifying the role of local resources in fully managing NYC’s load.

54 ENVIRONMENTAL SCIENCES↗

Bias Correction and Statistical Downscaling of Future Solar Irradiance Projections Using the NSRDB

Assessing renewable energy resources under future climate scenarios has been highlighted to understand potential impacts of future climate change in renewable generation on the power sector. Climate model projection has been recognized by the renewable energy community as a useful data set to analyze the impacts of future climate change on renewable resources. However, future climate projections generated from general circulation models (GCMs) contain inherent biases that need to be corrected for accurate analysis of future projections of climate variables. In addition, the coarse spatiotemporal resolution of GCMs needs to be improved for regional climate studies. In this work, we develop statistical methods to downscale future projections of global horizontal irradiance (GHI) in a computationally efficient way. Our approach builds statistical downscaling models that correct bias of climate projection of GHI and downscale the future GHI projection from daily-scale to hourly-scale. The National Solar Radiation Database (NSRDB) is used to calibrate the statistical models and validate the downscaled GHI projections across the contiguous United State (CONUS). Preliminary results show that the statistical approach efficiently downscales climate projections of GHI with a nBIAS of 3%, nMAE of 34 % and nRMSE of 46% calculated against NSRDB for CONUS. This study describes the implemented methodology and initial results as well as future research to create high-resolution climate data sets for solar energy applications.

analytical models↗

Laboratory colonization by Dirofilaria immitis alters the microbiome of female Aedes aegypti mosquitoes

Background: The ability of blood-feeding arthropods to successfully acquire and transmit pathogens of medical and veterinary importance has been shown to be interfered with, or enhanced by, the arthropod’s native microbiome. Mosquitoes transmit viruses, protozoan and filarial nematodes, the majority of which contribute to the 17% of infectious disease cases worldwide. Diroflaria immitis, a mosquito-transmitted filarial nematodes of dogs and cats, is vectored by several mosquito species including Aedes aegypti. Methods: In this study, we investigated the impact of D. immitis colonization on the microbiome of laboratory reared female Ae. aegypti. Metagenomic analysis of the V3–V4 variable region of the microbial 16S RNA gene was used for identification of the microbial differences down to species level. Results: We generated a total of 1068 OTUs representing 16 phyla, 181 genera and 271 bacterial species. Overall, in order of abundance, Proteobacteria, Bacteroidetes, Actinobacteria and Firmicutes were the most represented phylum with D. immitis-infected mosquitoes having more of Proteobacteria (71%) than uninfected mosquitoes (56.9%). An interesting finding in this study is the detection of Klebsiella oxytoca in relatively similar abundance in infected and uninfected mosquitoes, suggesting a possible endosymbiotic relationship, and has been previously shown to indirectly compete for nutrients with fungi on domestic housefly eggs and larvae. While D. immitis colonization has no effect on the overall species richness, we identified significant differences in the composition of selected bacterial genera and phyla between the two groups. We also reported distinct compositional and phylogenetic differences in the individual bacterial species when commonly identified bacteria were compared. Conclusions: To the best of our knowledge, this is the first study to understand the impact of a filarial infection on the microbiome of its mosquito vector. Further studies are required to identify bacteria species that could play an important role in the mosquito biology. While the microbiome composition of Ae. aegypti mosquito have been previously reported, our study shows that in an effort to establish itself, a filarial nematode modifies and alters the overall microbial diversity within its mosquito host.

54 ENVIRONMENTAL SCIENCES↗

Integrating Cambium Marginal Costs into Electric Sector Decisions: Opportunities to Integrate Cambium Marginal Cost Data into Berkeley Lab Analysis and Technical Assistance

NREL’s Cambium tool generates forward-looking simulations of marginal wholesale electricity costs associated with NREL’s Standard Scenarios. The scenarios include growing shares of variable renewable energy (VRE, i.e. wind and solar), among other power sector assumptions, between 2018 and 2050. The tool’s primary output—hourly costs at more than 130 balancing areas—could serve as public and transparent data source that supports electric-sector decision-making processes across the U.S. Berkeley Lab conducts a large range of analyses that use historical and forward-looking wholesale electricity prices to inform electric-sector decisions. In this report, Berkeley Lab uses its expertise to evaluate the Cambium cost data. We compare Cambium data with historical wholesale prices for the year 2018 and other modeled prices for the year 2030. We then present eight case studies in which Berkeley Lab researchers use Cambium data to replicate previous analyses based on other price datasets. We describe where primary findings and underlying key price dynamics align or differ, and highlight possible novel insights from the Cambium data. Finally, we qualitatively evaluate the suitability of Cambium costs in ten additional Berkeley Lab studies, though a direct comparison with alternative price data was not feasible at this time. The goal is to inform how electric-sector decision-makers and DOE program offices may be able to use this cohesive dataset, and to highlight what improvements to Cambium may make it even more useful.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Institutional Framework of Variable Renewable Energy Forecasting in India

The share of variable renewable energy (VRE) in India is growing rapidly, with a national goal of reaching 50% capacity from non-fossil fuel generation by 2030. One implication of this growth is the need for improved VRE forecasting methods. For this reason, the Ministry of New and Renewable Energy (MNRE) in India commissioned this study with support from the United States Agency for International Development (USAID), the National Renewable Energy Laboratory (NREL) in the United States, and the National Institute of Wind Energy (NIWE) in India. The objective of this study was to review the existing institutional framework and suggest changes needed to support the plans for large-scale VRE integration in the country. To achieve that objective, the authors consulted local stakeholders about the status of VRE forecasting in India, reviewed existing studies, and examined VRE forecasting methods around the world to identify best practices. Based on those best practices, the study presents six potential approaches to improve the VRE forecasting framework in India. Approaches include incentivizing VRE forecast improvement and use of the most accurate VRE forecast, creating an institution that will optimize VRE forecasts while maintaining and ensuring access to necessary data for forecasting, implementing a review and certification process for VRE forecast providers, forecasting closer to dispatch time and allowing for more frequent forecast revisions, increasing the frequency of weather forecasts, and aggregating VRE forecasts at the point of interconnection.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Progress Towards A Measurement of Neutrino Induced Charged Current Neutral Pion Production in the MicroBooNE Experiment

An analysis of MicroBooNE data with a signal of one muon, one neutral pion, and no charged pions is presented. Studying neutral pion production in the MicroBooNE detector provides an opportunity to better understand neutrino-argon interactions, and is crucial for future accelerator-based neutrino oscillation experiments. This analysis presents the progress towards the first measurement of the differential cross section for charged current (CC) $π^0$ production in neutrino-argon interactions. Using a dataset corresponding to about 7 × 10 20 protons on target (POT), we present an analysis which aims to measure the single differential cross sections as a function of the $π^0$ kinematic variables such as momentum and scattering angle. The Wiener-SVD technique for unfolding the measurement is presented and demonstrated using multiple generator predictions. A future iteration of this analysis will compare an unfolded data measurement to these models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Life Cycle Greenhouse Gas Emissions of Coal-Biomass Co-Firing Power Plants with Carbon Capture and Storage

The United States has set a target to achieve the net-zero economy by 2050. Bioenergy with Carbon Capture and Sequestration (BECCS) is one of the promising negative-emission routes in the mitigation portfolio to help meet this goal. Coal-biomass co-firing with carbon capture and storage (CCS) is a key BECCS technology to realize the carbon mitigation at fossil-fuel power plants. The mitigation potential of co-firing option is affected by numerous critical factors, such as biomass properties, co-firing level, and carbon capture rate. The objectives of the study are to characterize and estimate the life cycle greenhouse gas (GHG) emissions and performance of coal-biomass co-firing power plants with CCS, determine the breakeven co-firing level at power plants necessary to achieve net-zero life cycle emissions, and quantify the variabilities and uncertainties in life cycle emissions. The scope of the life cycle assessment includes the fuel supply, combustion-based power generation, and CO2 transport and storage. A fuel-based life cycle module is developed and embedded in the Integrated Environmental Control Model (IECM), a fossil-fuel power plant modeling tool. This study then applies the enhanced IECM to conduct the process-based life cycle assessment for an array of biomass co-firing scenarios. Deterministic analysis indicates that reaching net-zero life cycle emissions in a biomass co-firing plant without CCS deployment is challenging. Combining biomass co-firing and CCS deployment can significantly lower the overall life cycle emissions of power plants. Net-zero life cycle emissions can be achieved with a 20 wt.% co-firing level and 90% CCS when the Powder River Basin coal is co-fired with energy crops or forestry residues. However, the breakeven co-firing level for net-zero emissions depend on the selected fuel properties. Fuel supply and plant operation are the critical stages influencing the life cycle emissions of power plants with 90% CCS. Deployment of deep CCS beyond 90% CO2 capture can remarkably reduce operational emissions and the breakeven co-firing level. With 99% CCS, the breakeven co-firing rate can be reduced to 12% on average. These findings highlight the trade-offs between technical performance and environmental impact of biomass co-firing at coal-fired power plants and emphasize the role of deep CCS in achieving a net-zero emissions future.

Wu, Wanying↗

Model experiments to evaluate vortex dissipation devices proposed for installation on or near aircraft runways

The effectiveness of various vortex dissipation devices proposed for installation on or near aircraft runways is evaluated on basis of results of experiments conducted with a 0.03-scale model of a Boeing 747 transport aircraft in conjunction with a simulated runway. The test variables included type of vortex dissipation device, mode of operation of the powered devices, and altitude, lift coefficient and speed of the generating aircraft. A total of fifteen devices was investigated. The evaluation is based on time sequence photographs taken in the vertical and horizontal planes during each run.

Kohl, R. E.↗

Automated verification of flight software. User's manual

(Automated Verification of Flight Software), a collection of tools for analyzing source programs written in FORTRAN and AED is documented. The quality and the reliability of flight software are improved by: (1) indented listings of source programs, (2) static analysis to detect inconsistencies in the use of variables and parameters, (3) automated documentation, (4) instrumentation of source code, (5) retesting guidance, (6) analysis of assertions, (7) symbolic execution, (8) generation of verification conditions, and (9) simplification of verification conditions. Use of AVFS in the verification of flight software is described.

Saib, S. H.↗