Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “standard performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

SU-E-T-476: Quality Assurance for Gamma Knife Perfexion Using the Exradin W1 Plastic Scintillation Detector

Purpose: To perform dose profile and output factor measurements for the Exradin W1 plastic scintillation detector (PSD) for the Gamma Knife Perfexion (GKP) collimators in a Lucy phantom and to compare these values to an Exradin A16 ion chamber, EBT3 radiochromic film and treatment planning system (TPS) data. Methods: We used the Exradin W1 PSD which has a small volume, near-water equivalent sensitive element. It has also been shown to be energy independent. This new detector is manufactured and distributed by Standard Imaging, Inc. Measurements were performed for all three collimators (4 mm, 8 mm and 16 mm) for the GKP. The Lucy phantom with the PSD inserted was moved in small steps to acquire profiles in all three directions. EBT3 film was inserted in the Lucy phantom and exposed to a single shot for each collimator. Relative output factors were measured using the three detectors while profiles acquired with the PSD were compared to the ones measured with EBT3 radiochromic film. Results: Measured output factors relative to the largest collimator are as followsCollimator PS EBT3 A1616mm 1.000 1.000 1.0008mm 0.892 0.881 0.8834mm 0.795 0.793 0.727 The nominal (vendor) OFs for GKP are 1.000, 0.900, and 0.814, for collimators 16 mm, 8 mm and 4 mm, respectively. There is excellent agreement between all profiles measured with the PSD and EBT3 as well as with the TPS data provided by the vendor. Conclusion: Output factors measured with the W1 were consistent with the ones measured with EBT3 and A16 ion chamber. Measured profiles are in excellent agreement. The W1 detector seems well suited for beam QA for Gamma Knife due to its dosimetric characteristics. Sam Beddar would like to disclose a NIH/NCI SBIR Phase II grant (2R44CA153824-02A1) with Standard Imaging, Title: “Water-Equivalent Plastic Scintillation Detectors for Small Field Radiotherapy”.

07 ISOTOPE AND RADIATION SOURCES↗

Noiseless Vlasov–Poisson simulations with linearly transformed particles

We introduce a deterministic discrete-particle simulation approach, the Linearly-Transformed Particle-In-Cell (LTPIC) method, that employs linear deformations of the particles to reduce the noise traditionally associated with particle schemes. Formally, transforming the particles is justified by local first order expansions of the characteristic flow in phase space. In practice the method amounts of using deformation matrices within the particle shape functions; these matrices are updated via local evaluations of the forward numerical flow. Because it is necessary to periodically remap the particles on a regular grid to avoid excessively deforming their shapes, the method can be seen as a development of Denavit's Forward Semi-Lagrangian (FSL) scheme (Denavit, 1972 [8]). However, it has recently been established (Campos Pinto, 2012 [20]) that the underlying Linearly-Transformed Particle scheme converges for abstract transport problems, with no need to remap the particles; deforming the particles can thus be seen as a way to significantly lower the remapping frequency needed in the FSL schemes, and hence the associated numerical diffusion. To couple the method with electrostatic field solvers, two specific charge deposition schemes are examined, and their performance compared with that of the standard deposition method. Finally, numerical 1d1v simulations involving benchmark test cases and halo formation in an initially mismatched thermal sheet beam demonstrate some advantages of our LTPIC scheme over the classical PIC and FSL methods. Benchmarked test cases also indicate that, for numerical choices involving similar computational effort, the LTPIC method is capable of accuracy comparable to or exceeding that of state-of-the-art, high-resolution Vlasov schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multilevel Graph Partitioning for Three-Dimensional Discrete Fracture Network Flow Simulations

We present a topology-based method for mesh-partitioning in three-dimensional discrete fracture network (DFN) simulations that takes advantage of the intrinsic multi-level nature of a DFN. DFN models are used to simulate flow and transport through low-permeability fractured media in the subsurface by explicitly representing fractures as discrete entities. The governing equations for flow and transport are numerically integrated on computational meshes generated on the interconnected fracture networks. Modern high-fidelity DFN simulations require high-performance computing on multiple processors where performance and scalability depends partially on obtaining a high-quality partition of the mesh to balance work-loads and minimize communication across all processors. The discrete structure of a DFN naturally lends itself to various graph representations, which can be thought of as coarse-scale representations of the computational mesh. Using this concept, we develop two applications of the multilevel graph partitioning algorithm to partition the mesh of a DFN. In the first, we project a partition of the graph based on the DFN topology onto the mesh of the DFN and in the second, this DFN-based projection is used as the initial condition for further partitioning refinement of the mesh. We compare the performance of these methods with standard multi-level graph partitioning using graph-based metrics (cut, imbalance, partitioning time), computational-based metrics (FLOPS, iterations, solver time), and total run time. The DFN-based and the mesh-based partitioning methods are comparable in terms of the graph-based metrics, but the time required to obtain the partition is several orders of magnitude faster using the DFN-based partitions. The computation-based metrics show comparable performance between both methods so, in combination, the DFN-based partitions are several orders of magnitude faster than the mesh-based partition. Furthermore, the method which uses the DFN-partition solution as the initial condition of the mesh partition provided cut and imbalance values that were close to the mesh-based partition but in a fraction of the time. In turn, this hybrid method outperformed both of the other methods in terms of the total run time.

58 GEOSCIENCES↗

Composition and Wash Solution Measurements for LAW Melter Sulfur Tolerance Study Glasses

In this report, the Savannah River National Laboratory (SRNL) provides chemical analysis for several simulated low-activity waste (LAW) glass compositions, as well as chemical analysis of the wash solutions resulting from the preparation of these glasses. The Pacific Northwest National Laboratory (PNNL) selected and fabricated these glasses as part of a study on sulfur retention in glasses previously evaluated. The resulting data will be used in the development of improved property/composition models for LAW glass production at Hanford. Chemical analyses were performed on a representative sample of each of the study glasses to allow for comparisons with the targeted compositions. Glass standards were intermittently measured to assess the performance of the analytical instruments over the course of these analyses. There were no issues with measurements of the glass standards. A review of the individual glass composition measurements identified no analytical issues of concern. Minor differences between the targeted and measured concentrations of some of the baseline glass components were noted, including some low values for Al 2 O 3 , CaO, Na 2 O, and ZrO 2 . Chemical analyses were also performed on a representative sample of each of the wash solutions resulting from the preparation of the sulfur saturated melt (SSM) versions of the study glasses. No issues were noted for the measurements of the solution standards. Several elements had measurable concentrations in the wash solutions, including B, Ca, Cl, Cr, K, Li, Na, P, S, and V. The measured concentrations of Na in the wash solutions were in the range of 200-1200 mg/L. This may be attributed to both the excess sodium sulfate added as part of the SSM preparation process, as well as to the lower measured concentrations of Na 2 O in some of the SSM versions of the study glasses. The measured concentrations of sulfate in the wash solutions were in the range of about 750-2250 mg/L. PNNL may wish to make further comparisons between the compositions of the glasses and the compositions of the wash solutions.

36 MATERIALS SCIENCE↗

Development of an optically-pumped cesium standard at the Aerospace Corporation

We have initiated a research program to study the performance of compact optically-pumped cesium (Cs) frequency standards, which have potential for future timekeeping applications in space. A Cs beam clock apparatus has been assembled. Basic functions of the frequency standard have been demonstrated. Clock signals are observed with optical pumping schemes using one or two lasers. With two laser pumping, we are able to selectively place up to 80 percent of the atomic population into one of the clock transition states. The observed pattern of clock signal indicates that the velocity distribution of the Cs atoms contributing to the microwave signal is beam-Maxwellian. Thus, in the optically-pumped Cs frequency standards, the entire Cs population in the atomic beam could be utilized to generate the clock signals. This is in contrast to the conventional Cs beam standards where only approx. 1 percent of the atoms in the beam are used. More efficient Cs consumption can lead to improved reliability and increased useful lifetime of the clock. Our preliminary results are summarized in this paper

Yat C. Chan↗

Evaluating Methods for Measuring Grid Frequency in Low-Inertia Power Systems: Preprint

Accurate measurement of grid frequency is a critical component of reliable grid control. Traditionally, methods such as phase locked loops (PLLs) and discrete Fourier transforms (DFTs) have been used in inverters and phasor measurement units (PMUs) to measure frequency. However, as the percentage of inverter-based resources (IBRs) such as solar and wind has increased, these conventional frequency measurement methods are proving unable to guarantee reliable control in some cases. One challenge is measuring frequency during transient events, where there is a disruption in the steady state sinusoidal voltage. During these events, the underlying frequency of the grid may barely change, but measurement methods report a large spike in frequency due to the disrupted waveform. New methods must balance between suppressing spikes in frequency during faults, and providing fast, accurate, measurements in all other grid operation conditions, especially during events with high rate-of-change-of frequency (ROCOF), which are more prevalent in high-IBR power systems. This paper first surveys frequency measurement methods that have been proposed to reduce measurement errors during transient events. Then, both conventional and more novel frequency measurement methods are tested against an IEEE standard and industry recommendations, and their performance is evaluated for events simulated in PSCAD. Results quantify the trade-offs in performance during different grid conditions and lead to suggestions for the most appropriate frequency and ROCOF measurement methods for low inertia grids.

frequency↗

Multidimensional Fuel Performance Code: BISON

BISON is a finite element based nuclear fuel performance code applicable to a variety of fuel forms including light water reactor fuel rods, TRISO fuel particles, and metallic rod and plate fuel (Refs. [a, b, c]). It solves the fully-coupled equations of thermo-mechanics and species diffusion and includes important fuel physics such as fission gas release and material property degradation with burnup. BISON is based on the MOOSE framework (Ref. [d]) and can therefore efficiently solve problems on 1-, 2- or 3-D meshes using standard workstations or large high performance computers. BISON is also coupled to a MOOSE-based mesoscale phase field material property simulation capability (Refs. [e, f]). As described here, BISON includes the code library named FOX, which was developed concurrent with BISON. FOX contains material and behavioral models that are specific to oxide fuels.

Hales, Jason↗

Femto-second Laser’s Enabling New Length Scale Fabrications for Rapid Post Irradiation Examination of Materials: Concluding LDRD Project Poster

Mechanical testing campaigns are required to qualify materials for advanced reactor conditions, yet economical and safety limitations restrict the number of standardized mechanical tests that can be performed. Reducing the size of the sample is one approach to addressing these challenges and to accelerating testing. Previous research has shown that smaller mechanical test samples produce higher yield and ultimate stress values compared to values measured from standard sample sizes: the “smaller is stronger” effect. Specimens used in accelerated material testing campaigns must reflect bulk material performance to enable engineering scale material property measurement. The objective of this research project was to determine if engineering scale mechanical behavior—the yield stress—could be measured with micro-tensile test samples smaller than traditional standard testing geometries. The relationship between yield stress and sample size was explored with two different nuclear-relevant structural materials: Zircaloy-4 and tungsten. Mechanical testing of both metals demonstrated decreasing yield stress values with increasing sample gauge size across three different sizes. Yield stress values from the largest gauge size, fabricated with a femto-second laser ablation system, approach bulk material yield stress values reported in published literature. Preliminary analysis of the tungsten samples indicates the yield stress value depends on the grain characteristics within the gauge section, in addition to the gauge size. Accompanying modeling efforts, including response surface generation and crystal plasticity approaches, further demonstrated that the size of the sample gauge section alone cannot explain the change in yield stress values.

36 MATERIALS SCIENCE↗

Assessing modifications to the Abdul-Razzak and Ghan aerosol activation parameterization (version ARG2000) to improve simulated aerosol–cloud radiative effects in the UK Met Office Unified Model (UM version 13.0)

The representation of aerosol activation is a key source of uncertainty in global composition-climate model simulations of aerosol–cloud interactions. The Abdul-Razzak and Ghan (ARG) activation parameterization is used in several global and regional models that employ modal aerosol microphysics schemes. In this study, we investigate the ability of the ARG parameterization to reproduce simulations with a cloud parcel model and find its performance is sensitive to the geometric standard deviations (widths) of the lognormal aerosol modes. We recommend adjustments to three constant parameters in the ARG equations, which improve the performance of the parameterization for small mode widths and its ability to simulate activation in polluted conditions. For the accumulation mode width of 1.4 used in the Met Office Unified Model (UM), the modifications decrease the mean bias in the activated fraction of aerosols compared to a cloud parcel model from −6.6 % to +1.2 %. We implemented the improvements in the UM and compared simulated global cloud droplet concentrations with satellite observations. The simulated cloud radiative effect changes by −1.43 W m −2 (6 %) and aerosol indirect radiative forcing over the industrial period changes by −0.10 W m −2 (10 %).

Ghosh, Pratapaditya [Carnegie Mellon University, P↗

WOW Technology's Innovative Radioactive Liquid Waste Treatment - 16128

WOW presents its revolutionary technology and equipment for liquid radioactive waste treatment: outperforming ultimate water decontamination and purification process, enhanced sludge concentration, no secondary waste nor consumables, fully automated, remote controlled and self-decontaminating device. The WOW's technology is based upon a never before observed discovery of fluid dynamics science: the possibility of performing a molecular separation between solute and suspended elements and the solvent. The combination of such a molecular separation process with a standard vacuum evaporation improves the abatement performances by thousands of times, with respect to those of the state of the art vacuum evaporators. In addition to this, no secondary waste is produced during the process, as no filters, membranes, resins or additives are used. WOW equipment, automated and remote controlled, self decontaminates after use and can be designed and constructed either tailored to the application needs or with a modular approach for enhanced transportability and application flexibility. After the preliminary verification by CNR, the Italian National Research Center, WOW Technology's decontamination device was tested c/o LENA, the Laboratory of Applied Nuclear Energy of the University of Pavia, Italy with a simulated solution 6000 times more contaminated than the nuclear reactor's cooling water of Fukushima-Daiichi NPP. In addition to that, WOW's technology was also used in a real case at the Radiochemistry laboratory of the Pavia's University Chemistry department. Both the above mentioned contaminated fluids have been successfully decontaminated without production of additional or secondary waste. WOW's technology has already performed on industrial scale c/o the Nuclear Repository of S.S.M. in Saluggia, Italy: 45000 liters of acid radioactive solution have been successfully decontaminated to a Decontamination Factor (DF) of 335000 for Cs-137 by one single evaporation step and without using any additional tool to control steam. [Performances independently certified by: National Physics Laboratory (UK) and Pavia University Radiochemistry Laboratory, Chemistry Department (Italy)]. The high decontamination factors and the high volume reduction of the sludge make this technology suitable for the ultimate treatment of highly contaminated liquid waste such as the Fukushima-Daiichi nuclear reactor's cooling water. The WOW's technology addresses as well to interventions in both, operating and decommissioning nuclear power plants and any other nuclear and radioactive facility whose produced and/or stored radioactive liquid solutions, including acid liquid solutions, can be successfully treated, the waste volume reduced and no secondary waste produced. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Repurposing Archetypal Preventive Radiological/Nuclear Detectors to the Consequence Management Mission

In the first hours or days after an unplanned release of radioactive material to the environment, the radiation detection instruments most widely available to local first responders may be those currently fielded for interdiction missions. This study investigated how such preventative radiological / nuclear detection instruments could perform if repurposed to consequence management missions. A representative sample of three archetypes (body-worn, human carried, and other/large detection volume) encompassed six categories: personal radiation detector, extended range personal radiation detector, personal emergency radiation detector, radio-isotope identification device, human portable detector/backpack, and vehicle mounted large detection volume. Overall 19 models of equipment were included in the study. Laboratory evaluations were designed to assess the capabilities of the instruments in four consequence management missions: exposure rate, integrated exposure, radiation survey, and contamination screening. As applicable, the evaluations included measurement of exposure rate, integrated exposure, overrange response, and angular response. The results were compared to benchmarks from the American National Standards Institute ANSI N42.49A. The performance of the instruments for initial screening for contamination was assessed by an automated radioactive source moving past the detectors at various speeds and distances. The results demonstrate that if the equipment is used in accordance with the mission analysis and categories, and within the original equipment manufacturer specifications, it is possible to achieve sufficient accuracy to estimate and document doses to responders, plan entries into contaminated areas, detect contamination, and protect the public, until such time as outside resources arrive with sufficient numbers of standard health physics instruments and personnel dosimetry to replace the preventative radiological / nuclear detection instruments. Finally, this evaluation campaign was conducted to complement the National Council on Radiation Protection and Measurements Report-179 on Guidance for Emergency Response Dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutronic feasibility analysis of fully ceramic microencapsulated fuel for commercial PWRs

The fully ceramic microencapsulated (FCM) fuel is based on tri-structural isotropic (TRISO) coated particles embedded in silicon carbide (SiC) matrix, which is among the accident tolerant fuel concept options. With the strength of high fission product retention, the FCM fuel provides potential superior safety performance. Compared to the conventional standard UO{sub 2} fuel, the deficiency of FCM fuel is its considerable lower fissile inventory, which results in a reduced reactor power or/and life. Supposing the FCM fuel is used as direct replacement of the fuel in commercial PWRs, the spectrum is softened due to the usage of SiC as matrix, and the moderator temperature coefficient is possible to be positive at the beginning of life, leading to high risk during operation. A neutronic feasibility study of FCM fuel utilized in commercial PWRs is performed in the paper. The fuel enrichment and under-moderated lattice are evaluated by analyzing the typical TRISO particle with UO{sub 2} kernels which is widely used in high temperature gas reactors and that with enlarged UN fuel kernels. It was found that under the mandatory constraint of low enriched uranium, the FCM fuel with UO{sub 2} kernels, although relatively mature, is only capable of small reactor designs, and the assembly lattice needs to be modified. The FCM fuel with UN kernels, when directly loading in the commercial PWRs, can yield comparable reactor power and life; however, a higher fuel enrichment and the fuel design and fabrication need to be optimized. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

H{sup -} Ion Source Development for the LANSCE Accelerator Systems

Employment of H- ion sources for the LANSCE accelerator systems goes back about 20 years, to the construction of the Proton Storage Ring (PSR). The standard ion source consists of a filament driven multi-cusp discharge vessel with a biased converter electrode for negative-ion production and an 80-kV extraction system feeding into a 670-kV electrostatic pre-accelerator. The source typically delivers 18 mA pulsed beam current into the pre-accelerator column and reaches up to 35 days between services at 60 Hz pulse repetition rate. Recent development efforts with this source have been dedicated to improved filament material, improved cesium oven geometry and operating the source at elevated temperatures. A second line of development focuses on filament-less devices driven by a helicon discharge. Performance data obtained with the standard source as well as key results for the helicon experiments are given in this paper; the helicon work is discussed in a separate paper in much greater detail.

43 PARTICLE ACCELERATORS↗

Measurement of $\boldsymbol{\ttb}$ production in the tau + jets channel using $\boldsymbol{p\bar{p}}$ collisions at $\boldsymbol{\sqrt{s} = 1.96}$~TeV

We present a measurement of the t{bar t} production cross section multiplied by the branching ratio to tau lepton decaying semi-hadronically ({tau}{sub h}) plus jets, {sigma}(p{bar p} {yields} t{bar t} + X) {center_dot} BR(t{bar t} {yields} {tau}{sub h} + jets), at a center of mass energy {radical}s = 1.96 TeV using 1 fb{sup -1} of integrated luminosity collected with the D0 detector. Assuming a top quark mass of 170 GeV, we measure {sigma}{sub t{bar t}} {center_dot} BR{sub {tau}{sub h}+j} = 0.60{sub -0.22}{sup +0.23}(stat){sub -0.14}{sup +0.15}(syst){+-}0.04 (lumi) pb. In addition, we extract the t{bar t} production cross section using the t{bar t} {yields} {tau}{sub h} + jets topology, with the result {sigma}{sub t{bar t}} = 6.9{sub -1.2}{sup +1.2}(stat){sub -0.7}{sup +0.8}(syst) {+-} 0.4 (lumi) pb. These findings are in good agreement with standard model predictions and measurements performed using other top quark decay channels.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accurate Efficiency Measurements for Emerging PV: A Comparison of NREL's Steady-State Performance Calibration Protocol Between Conventional and Emerging PV Technologies

Emerging PV technologies (e.g. Perovskite, and Quantum Dot) are commonly known to possess challenges for accurate performance measurement under the existing IEC 60904 series of standards, which were developed for conventional Si solar cells. Potential performance artifacts depending on scan rates and directions and light bias exposure history are often seen in those emerging solar cells. To avoid these artifacts and provide an unbiased and reliable efficiency measurement, NREL's Cell and Module Performance (CMP) Group has developed a steady-state performance calibration protocol - the asymptotic P MAX method. In this paper, we applied this procedure to four PV cell technologies, Si, CIGS, perovskite, and Quantum Dot (QD), and compared their performance variations between the transient and the steady-state conditions. By comparison, we found that the performance parameters ( i.e. V OC , I SC , FF, ..eta..) measured between fast I-V scans (and the asymptotic method (steady-state) change significantly for perovskite and QD cells. These changes do not happen for Si and CIGS cells. Furthermore, the statistical performance analysis on nearly 100 emerging cells received globally (including OPV, Perovskite, and QD) shows that over 70 % of the fast I-V scans have a relative performance deviation larger than 1% compared to those determined using the asymptotic P MAX scan. Given the complex dynamic behavior observed in emerging PV devices, the CMP group at NREL thus only certifies their steady steady-state performance using the Asymptotic P MAX method. We highly recommend similar steady-state performance calibration protocol for all researchers in emerging PV because accuracy in reported efficiencies is critical to the long-term success of those promising new PV technologies.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Incorporating Research Findings into Standards and Requirements for Space Medicine

The Vision for Exploration has been the catalyst for NASA to refocus its life sciences research. In the future, life sciences research funded by NASA will be focused on answering questions that directly impact setting physiological standards and developing effective countermeasures to the undesirable physiological and psychological effects of spaceflight for maintaining the health of the human system. This, in turn, will contribute to the success of exploration class missions. We will show how research will impact setting physiologic standards, such as exposure limits, outcome limits, and accepted performance ranges. We will give examples of how a physiologic standard can eventually be translated into an operational requirement, then a functional requirement, and eventually spaceflight hardware or procedures. This knowledge will be important to the space medicine community as well as to vehicle contractors who, for the first time, must now consider the human system in developing and constructing a vehicle that can achieve the goal of success.

Duncan, J. Michael↗

Analyzing AQP Data to Improve Electronic Flight Bag (EFB) Operations and Training

Key points include: Initiate data collection and analysis early in the implementation process. Use data to identify procedural and training refinements. Use a de-identified system to analyze longitudinal data. Use longitudinal I/E data to improve their standardization. Identify above average pilots and crews and use their performance to specify best practices. Analyze below average crew performance data to isolate problems with the training, evaluator standardization and pilot proficiency.

Seamster, Thomas L.↗

133Xe Noble Gas Mass Spectrometry Measurement for High Purity Germanium Detector Performance Verification

Idaho National Laboratory produces quality control standards for laboratories that operate xenon radionuclide monitoring systems. Activities reported with each quality control standard are quantified using high purity germanium detectors. A collection of measurement capabilities are being set up at Idaho National Laboratory to establish an in-house high purity germanium detector performance verification system, with noble gas mass spectrometry being one of these measurement capabilities. The first noble gas mass spectrometry and high purity germanium measurement comparison is presented here. A Xe-133 gas sample was prepared and the activity was quantified with high purity germanium detectors. The Xe-133 sample was diluted with a known quantity of isotopically enriched Xe-126 gas; the resulting Xe-133 : Xe-126 atom ratio was calculated to be 1.15x10-4 +/- 2% at reference time t. An aliquot of this gas sample containing approximately 10 million Xe-133 atoms was introduced into a ThermoFisher Scientific Helix MC Plus noble gas mass spectrometer for analysis. The measured Xe-133 : Xe-126 atom ratio was determined to be 1.10x10-4 +/- 2% (1-sigma uncertainty) at reference time t, about 4.3% lower than the atom ratio determined with the measured high purity germanium activity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗