Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spreading models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

An Accurate Model of Beam Ion Instability with Nonlinear Space Charge, Realistic Beam Optics and Multiple Gas Species Vacuum

The previous analyses of beam ion instability have been performed for single gas species only. However, there are multiple gas species in the vacuum chambers of an accelerator. The superposition rule doesn’t apply in general and it overestimates the instability. Therefore, it is important to use multiple gas species model. On the other hand, the variation of beam size along the accelerator ring or linac provides Landau damping to the instability. In previous studies, the effect of beam optics has been represented by a frequency spread and a quality factor. In practice, it could be difficult to accurately estimate the frequency spread and quality factor for general beam optics because the variation of the beam size along the ring usually doesn’t have simple distribution. This paper provided a more accurate method to analyze beam ion instability with arbitrary vacuum component and arbitrary beam optics where the variation of the beam size along the accelerator ring or linac can be arbitrary. Meanwhile, the nonlinear space charge effect is also included and the general beam filling pattern can be easily modeled. Our analyses agree well with expensive simulations.

43 PARTICLE ACCELERATORS↗

A computational model tracks whole-lung Mycobacterium tuberculosis infection and predicts factors that inhibit dissemination

Mycobacterium tuberculosis (Mtb), the causative infectious agent of tuberculosis (TB), kills more individuals per year than any other infectious agent. Granulomas, the hallmark of Mtb infection, are complex structures that form in lungs, composed of immune cells surrounding bacteria, infected cells, and a caseous necrotic core. While granulomas serve to physically contain and immunologically restrain bacteria growth, some granulomas are unable to control Mtb growth, leading to bacteria and infected cells leaving the granuloma and disseminating, either resulting in additional granuloma formation (local or non-local) or spread to airways or lymph nodes. Dissemination is associated with development of active TB. It is challenging to experimentally address specific mechanisms driving dissemination from TB lung granulomas. Herein, we develop a novel hybrid multi-scale computational model, MultiGran, that tracks Mtb infection within multiple granulomas in an entire lung. MultiGran follows cells, cytokines, and bacterial populations within each lung granuloma throughout the course of infection and is calibrated to multiple non-human primate (NHP) cellular, granuloma, and whole-lung datasets. We show that MultiGran can recapitulate patterns of in vivo local and non-local dissemination, predict likelihood of dissemination, and predict a crucial role for multifunctional CD8+ T cells and macrophage dynamics for preventing dissemination.

59 BASIC BIOLOGICAL SCIENCES↗

A scheme for parameterizing cirrus cloud ice water content in general circulation models

Clouds strongly influence th earth's energy budget. They control th amount of solar radiative energy absorbed by the climate system, partitioning the energy between the atmosphere and the earth's surface. They also control the loss of energy to space by their effect on thermal emission. Cirrus and altostratus are the most frequent cloud types, having an annual average global coverage of 35 and 40 percent, respectively. Cirrus is composed almost entirely of ice crystals and the same is frequently true of the upper portions of altostratus since they are often formed by the thickening of cirrostratus and by the spreading of the middle or upper portions of thunderstorms. Thus, since ice clouds cover such a large portion of the earth's surface, they almost certainly have an important effect on climate. With this recognition, researchers developing climate models are seeking largely unavailable methods for specifying the conditions for ice cloud formation, and quantifying the spatial distribution of ice water content, IWC, a necessary step in deriving their radiative characteristics since radiative properties are apparently related to IWC. A method is developed for specifying IWC in climate models, based on theory and measurements in cirrus during FIRE and other experiments.

Heymsfield, Andrew J.↗

Effects of two-dimensional materials on human mesenchymal stem cell behaviors

Graphene, a typical two-dimensional (2D) material, is known to affect a variety of stem cell behaviors including adhesion, spreading, growth, and differentiation. Here, we report for the first time the effects of four different emerging 2D materials on human adipose-derived mesenchymal stem cells (hADMSCs). Graphene oxide (GO), molybdenum sulfide (MoS{sub 2}), tungsten sulfide (WS{sub 2}), and boron nitride (BN) were selected as model two-dimensional materials and were coated on cell-culture substrates by a drop-casting method. Acute toxicity was not observed with any of the four different 2D materials at a low concentration range (<5 μg/ml). Interestingly, the 2D material-modified substrates exhibited a higher cell adhesion, spreading, and proliferation when compared with a non-treated (NT) substrate. Remarkably, in the case of differentiation, the MoS{sub 2}-, WS{sub 2}-, and BN-modified substrates exhibited a better performance in terms of guiding the adipogenesis of hADMSCs when compared with both NT and GO-modified substrates, based on the mRNA expression level (qPCR) and amount of lipid droplets (ORO staining). In contrast, the osteogenesis was found to be most efficiently induced by the GO-coated substrate (50 μg/mL) among all 2D-material coated substrates. In summary, 2D materials could act as favorable sources for controlling the stem cell growth and differentiation, which might be highly advantageous in both biomedical research and therapy. - Highlights: • The toxicity of four different two-dimensional materials on hADMSCs was studied. • All four different 2D materials enhanced the cell adhesion, spreading and proliferation. • WS{sub 2}-, MoS{sub 2}-, and BN-coated substrates enhanced the adipogenesis of hADMSCs. • GO showed the best performance for guiding the osteogenesis of hADMSCs.

60 APPLIED LIFE SCIENCES↗

Stress and strain relaxation in magnesium AZ31 rolled plate: In-situ neutron measurement and elastic viscoplastic polycrystal modeling

Continuous mechanical tests with strain holds (stress relaxation) and with stress holds (strain relaxation) are performed simultaneously with in-situ neutron measurements to analyze the mechanisms of stress and strain relaxation in Mg AZ31 rolled plate. A dislocation activity based constitutive model, accounting for internal stress statistical distributions, is proposed and implemented into an elastic viscoplastic self-consistent (EVPSC) framework to simultaneously describe both stress and strain relaxation. The model captures the experimental data in terms of macroscopic stress strain curves, evolution of stress and strain during holding, as well as evolution of the internal elastic strains. Model results indicate that the magnitude of the stress relaxed during strain holding is dependent on both, the magnitude of the flow stress and the spread of the resolved shear stress distribution. The magnitude of strain accumulated during stress holding is, on the other hand, dependent on the magnitude of the hardening rate and on the spread of the resolved shear stress distribution. Furthermore, the internal elastic strains are directly correlated with the stress state, and hence the stress relaxation during strain holds has a greater influence on the lattice strains than strain relaxation during stress holds.

36 MATERIALS SCIENCE↗

Measuring Liquid Drop Properties on Nanoscale 1D Patterned Photoresist Structures

This communication reports liquid wetting properties of DI-water on one-dimensional nano-patterned photoresist lines atop a silicon substrate as the pattern period is varied from 0.3- to 1.0-µm. Both constant photoresist height and constant width/height ratios are investigated. The line/period ratio was fixed at 0.3 (0.4) for different measurement sequences. The surface of the photoresist was treated with a short CHF 3 reactive ion etch to ensure consistent hydrophobic photoresist: water surface energies. Average parallel contact angle (θ || ), average perpendicular contact angle (θ ⊥ ), drop width (W), and drop length (L) at constant volume were measured on nano-patterned surfaces fabricated with interferometric lithography. Both θ || and θ ⊥ contact angles increase as the period (0.3- to 1-μm) increases; the θ || spreading rate is faster than θ ⊥ due to pinning on the grooves resulting in an elongated drop shape. The traditional Wenzel and Cassie-Baxter models of drop contact angles were developed for isotropic random 2D roughness and do not account for the anisotropy induced by the 1D line patterns. The observed angular variations with period are not consistent with either model. Understanding liquid wetting properties and hydrophobicity on 1D silicon surfaces has many applications in lab-on-a-chip, micro/nano-fluidic devices, roll-to-roll nano-imprint fabrication, self-cleaning surfaces, and micro-reactors.

42 ENGINEERING↗

Utility of reactively sputtered CuN{sub x} films in spintronics devices

We have studied nitrified copper (CuN{sub x}) thin films grown by reactive sputtering in the context of spintronic devices. The Ar-to-N{sub 2} flow ratio enables tunability of the electrical resistivity and surface roughness of the CuN{sub x} films, with the former increasing to nearly 20 times that of Cu, and the latter reduced to the atomic scale. Incorporating this into a Ta/CuN{sub x}/Ta seed stack for spin valves improves the current-in-plane (CIP) magnetoresistance; maximum magnetoresistance results with CuN{sub x} seed layer and Cu interlayer. Finally, finite element modeling results are presented that suggest the use of CuN{sub x} in nanocontact spin torque oscillators can enhance current densities by limiting the current spread through the device. This may positively impact threshold currents, power requirements, and device reliability.

36 MATERIALS SCIENCE↗

Dynamics of homogeneous cavitation with pressure feedback

Theoretical studies of homogeneous cavitation have largely been based on the classical nucleation theory. However, existing cavitation models cannot adequately describe its dynamics at nanosecond timescale, which has been called for in other fields. We develop a model coupling nucleation kinetics with cavity growth and pressure feedback as saturation mechanisms. Our numerical studies reveal the exponential dependence of cavitation characteristics such as saturation cavity density and most probable cavity radius on model parameters: Tolman length and initial pressure. This work also sheds light on the possibility of accurately determining Tolman length, whose value has a large spread in the literature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ON THE STELLAR CONTENT OF THE STARBURST GALAXY IC10

We investigate the stellar content of the starburst dwarf galaxy IC10 using accurate and deep optical data collected with the Advanced Camera for Surveys and with the Wide Field Planetary Camera 2 onboard the Hubble Space Telescope. The comparison between theory and observations indicates a clear change in age distribution when moving from the center toward the external regions. Moreover, empirical calibrators and evolutionary predictions suggest the presence of a spread in heavy element abundance of the order of one-half dex. The comparison between old and intermediate-age core He-burning models with a well defined overdensity in the color-magnitude diagram indicates the presence of both intermediate-age, red clump stars and of old, red horizontal branch stars.

99 GENERAL AND MISCELLANEOUS↗

LUNAR ACCRETION FROM A ROCHE-INTERIOR FLUID DISK

We use a hybrid numerical approach to simulate the formation of the Moon from an impact-generated disk, consisting of a fluid model for the disk inside the Roche limit and an N-body code to describe accretion outside the Roche limit. As the inner disk spreads due to a thermally regulated viscosity, material is delivered across the Roche limit and accretes into moonlets that are added to the N-body simulation. Contrary to an accretion timescale of a few months obtained with prior pure N-body codes, here the final stage of the Moon's growth is controlled by the slow spreading of the inner disk, resulting in a total lunar accretion timescale of {approx}10{sup 2} years. It has been proposed that the inner disk may compositionally equilibrate with the Earth through diffusive mixing, which offers a potential explanation for the identical oxygen isotope compositions of the Earth and Moon. However, the mass fraction of the final Moon that is derived from the inner disk is limited by resonant torques between the disk and exterior growing moons. For initial disks containing <2.5 lunar masses (M{sub Last-Quarter-Moon }), we find that a final Moon with mass > 0.8 M{sub Last-Quarter-Moon} contains {<=}60% material derived from the inner disk, with this material preferentially delivered to the Moon at the end of its accretion.

79 ASTRONOMY AND ASTROPHYSICS↗

XMM-Newton observations of three interacting luminous infrared galaxies

We investigate the X-ray properties of three interacting luminous infrared galaxy systems. In one of these systems, IRAS 18329+5950, we resolve two separate sources. A second and third source, IRAS 19354+4559 and IRAS 20550+1656, have only a single X-ray source detected. We compare the observed emission to point-spread function (PSF) profiles and determine that they are all consistent with the PSF, albeit with large uncertainties for some of our sources. We then model the spectra to determine soft (0.5-2 keV) and hard (2-10 keV) luminosities for the resolved sources and compare these to relationships found in the literature between infrared and X-ray luminosities for starburst galaxies. We obtain luminosities (0.5-10 keV) ranging from 1.7 to 7.3 × 10{sup 41} erg s{sup –1} for our systems. These X-ray luminosities are consistent with predictions for star-formation-dominated sources and thus are most likely due to starbursts, but we cannot conclusively rule out active galactic nuclei.

79 ASTRONOMY AND ASTROPHYSICS↗

Projected changes in seasonal precipitation extremes over the United States in CMIP6 simulations

Quantifying how climate change may impact precipitation extremes is a priority for informing adaptation and policy planning. In this study, Coupled Model Intercomparison Project phase 6 global climate models are analyzed to identify robust signals of projected changes in summer and winter precipitation extremes over the United States (US). Under a projected fossil-fuel based economic (i.e. high greenhouse gas emissions) scenario, our results show consistent changes in the seasonal patterns for many precipitation extremes by the end of the 21st century. We find a robust projected increase in the intensity of winter precipitation across models, with less agreement during the summer. Similarly, a robust projected amplification of heavy precipitation over the northern US is evident in winter, while intermodel spread is prevalent in summer projections. Specifically, the heavy and very heavy winter precipitation days (R10mm and R20mm) exhibit larger increases compared to other aspects of precipitation. Additionally, changes in dry extremes (e.g. consecutive dry days) are found to differ significantly across various subregions and seasons. Overall, our results suggest that the US may suffer more natural disasters such as floods and droughts in the future.

54 ENVIRONMENTAL SCIENCES↗

The clustering of the SDSS-IV extended Baryon Oscillation Spectroscopic Survey DR14 quasar sample: measurement of the growth rate of structure from the anisotropic correlation function between redshift 0.8 and 2.2

We present the clustering measurements of quasars in configuration space based on the Data Release 14 (DR14) of the Sloan Digital Sky Survey IV extended Baryon Oscillation Spectroscopic Survey (eBOSS). This data set includes 148 659 quasars spread over the redshift range 0.8 ≤ z ≤ 2.2 and spanning 2112.9 deg 2 . We use the Convolution Lagrangian Perturbation Theory approach with a Gaussian Streaming model for the redshift space distortions of the correlation function and demonstrate its applicability for dark matter haloes hosting eBOSS quasar tracers. At the effective redshift z eff = 1.52, we measure the linear growth rate of structure fσ 8 (zeff) = 0.426 ± 0.077, the expansion rate H(z eff ) = 159$+12\atop{-13}$(r$fid\atop{s}$ /r s ) kms -1 Mpc -1 , and the angular diameter distance DA(z eff ) = 1850$+90\atop{-115}$ (r s /r$fid\atop{s}$) Mpc, where r s is the sound horizon at the end of the baryon drag epoch and rfid s is its value in the fiducial cosmology. The quoted uncertainties include both systematic and statistical contributions. The results on the evolution of distances are consistent with the predictions of flat Λ-cold dark matter cosmology with Planck parameters, and the measurement of fσ 8 extends the validity of General Relativity to higher redshifts (z > 1). This paper is released with companion papers using the same sample. The results on the cosmological parameters of the studies are found to be in very good agreement, providing clear evidence of the complementarity and of the robustness of the first full-shape clustering measurements with the eBOSS DR14 quasar sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Feasibility studies of a passive scatter proton therapy nozzle without a range modulator wheel

The purpose of this work was to determine the feasibility of producing a spread out Bragg peak (SOBP) without a range modulation wheel (RMW) using the passive scattering beam delivery technique. For this study, a comprehensive Monte Carlo model of a passive scattering treatment nozzle was used. The RMW was removed from the model leaving only the initial fixed scatterer (RMW-free configuration). Range modulation was achieved by directly changing the energy of the proton beam entering the nozzle. To produce a uniform SOBP, the number of protons injected into the nozzle at each beam energy was ''dose weighted.'' To do so, the effective number of protons was calculated for the individual initial energies using an analytical dose-weighting function, and the resulting weighted Bragg curves were summed together to produce an SOBP of the desired width. We found that SOBPs calculated using the RMW-free nozzle configuration were in very good agreement to those calculated with the standard nozzle configuration containing the RMW for the 250, 180, and 100 MeV maximum beam energies. The depth of the distal 90% dose and the 80%-20% distal dose falloff of SOBPs calculated with the two different nozzle configurations agreed to within a millimeter for the three beam energy options considered in this study. In addition, the 80%-20% lateral penumbra for the cross-field dose profiles calculated with the RMW-free delivery method agreed with results calculated using the standard RMW technique to less than one millimeter. For an equal number of protons injected into the nozzle, an increase of up to 10% in the delivered dose and a significant reduction in both the in-air secondary neutron fluence and dose equivalent (H/D) were observed at the isocenter by removing the RMW from the treatment nozzle and modulating the initial proton beam energy. However, increases in delivery time of up to 70% were also estimated with this method. Our results suggest that it is feasible to deliver a passively scattered dose distribution with an RMW-free nozzle configuration with clinical characteristics comparable to those using standard methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Homogenized blocked arcs for multicriteria optimization of radiotherapy: Analytical and numerical solutions

Purpose: Homogenized blocked arcs are intuitively appealing as basis functions for multicriteria optimization of rotational radiotherapy. Such arcs avoid an organ-at-risk (OAR), spread dose out well over the rest-of-body (ROB), and deliver homogeneous doses to a planning target volume (PTV) using intensity modulated fluence profiles, obtainable either from closed-form solutions or iterative numerical calculations. Here, the analytic and iterative arcs are compared. Methods: Dose-distributions have been calculated for nondivergent beams, both including and excluding scatter, beam penumbra, and attenuation effects, which are left out of the derivation of the analytic arcs. The most straightforward analytic arc is created by truncating the well-known Brahme, Roos, and Lax (BRL) solution, cutting its uniform dose region down from an annulus to a smaller nonconcave region lying beyond the OAR. However, the truncation leaves behind high dose hot-spots immediately on either side of the OAR, generated by very high BRL fluence levels just beyond the OAR. These hot-spots can be eliminated using alternative analytical solutions ''C'' and ''L,'' which, respectively, deliver constant and linearly rising fluences in the gap region between the OAR and PTV (before truncation). Results: Measured in terms of PTV dose homogeneity, ROB dose-spread, and OAR avoidance, C solutions generate better arc dose-distributions than L when scatter, penumbra, and attenuation are left out of the dose modeling. Including these factors, L becomes the best analytical solution. However, the iterative approach generates better dose-distributions than any of the analytical solutions because it can account and compensate for penumbra and scatter effects. Using the analytical solutions as starting points for the iterative methodology, dose-distributions almost as good as those obtained using the conventional iterative approach can be calculated very rapidly. Conclusions: The iterative methodology is appropriate and useful for computing homogenized blocked arcs, as it produces better dose-distributions than the analytic approaches and their obvious extensions, and can more straightforwardly be used to generate homogenized arcs for concave OARs. However, the analytical solutions provide promising starting points for the iterative algorithm, leading to fast convergence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A pencil beam algorithm for helium ion beam therapy

Purpose: To develop a flexible pencil beam algorithm for helium ion beam therapy. Dose distributions were calculated using the newly developed pencil beam algorithm and validated using Monte Carlo (MC) methods. Methods: The algorithm was based on the established theory of fluence weighted elemental pencil beam (PB) kernels. Using a new real-time splitting approach, a minimization routine selects the optimal shape for each sub-beam. Dose depositions along the beam path were determined using a look-up table (LUT). Data for LUT generation were derived from MC simulations in water using GATE 6.1. For materials other than water, dose depositions were calculated by the algorithm using water-equivalent depth scaling. Lateral beam spreading caused by multiple scattering has been accounted for by implementing a non-local scattering formula developed by Gottschalk. A new nuclear correction was modelled using a Voigt function and implemented by a LUT approach. Validation simulations have been performed using a phantom filled with homogeneous materials or heterogeneous slabs of up to 3 cm. The beams were incident perpendicular to the phantoms surface with initial particle energies ranging from 50 to 250 MeV/A with a total number of 10{sup 7} ions per beam. For comparison a special evaluation software was developed calculating the gamma indices for dose distributions. Results: In homogeneous phantoms, maximum range deviations between PB and MC of less than 1.1% and differences in the width of the distal energy falloff of the Bragg-Peak from 80% to 20% of less than 0.1 mm were found. Heterogeneous phantoms using layered slabs satisfied a {gamma}-index criterion of 2%/2mm of the local value except for some single voxels. For more complex phantoms using laterally arranged bone-air slabs, the {gamma}-index criterion was exceeded in some areas giving a maximum {gamma}-index of 1.75 and 4.9% of the voxels showed {gamma}-index values larger than one. The calculation precision of the presented algorithm was considered to be sufficient for clinical practice. Although only data for helium beams was presented, the performance of the pencil beam algorithm for proton beams was comparable. Conclusions: The pencil beam algorithm developed for helium ions presents a suitable tool for dose calculations. Its calculation speed was evaluated to be similar to other published pencil beam algorithms. The flexible design allows easy customization of measured depth-dose distributions and use of varying beam profiles, thus making it a promising candidate for integration into future treatment planning systems. Current work in progress deals with RBE effects of helium ions to complete the model.

60 APPLIED LIFE SCIENCES↗

Inferring Viral Dynamics in Chronically HCV Infected Patients from the Spatial Distribution of Infected Hepatocytes

Chronic liver infection by hepatitis C virus (HCV) is a major public health concern. Despite partly successful treatment options, several aspects of intrahepatic HCV infection dynamics are still poorly understood, including the preferred mode of viral propagation, as well as the proportion of infected hepatocytes. Answers to these questions have important implications for the development of therapeutic interventions. In this study, we present methods to analyze the spatial distribution of infected hepatocytes obtained by single cell laser capture microdissection from liver biopsy samples of patients chronically infected with HCV. By characterizing the internal structure of clusters of infected cells, we are able to evaluate hypotheses about intrahepatic infection dynamics. We found that individual clusters on biopsy samples range in size from 4-50 infected cells. In addition, the HCV RNA content in a cluster declines from the cell that presumably founded the cluster to cells at the maximal cluster extension. These observations support the idea that HCV infection in the liver is seeded randomly (e.g. from the blood) and then spreads locally. Assuming that the amount of intracellular HCV RNA is a proxy for how long a cell has been infected, we estimate based on models of intracellular HCV RNA replication and accumulation that cells in clusters have been infected on average for less than a week. Further, we do not find a relationship between the cluster size and the estimated cluster expansion time. Lastly, our method represents a novel approach to make inferences about infection dynamics in solid tissues from static spatial data.

59 BASIC BIOLOGICAL SCIENCES↗

Pulse compressor with aberration correction

In this SBIR project, Electron Optica, Inc. (EOI) is developing an electron mirror-based pulse compressor attachment to new and retrofitted dynamic transmission electron microscopes (DTEMs) and ultrafast electron diffraction (UED) cameras for improving the temporal resolution of these instruments from the characteristic range of a few picoseconds to a few nanoseconds and beyond, into the sub-100 femtosecond range. The improvement will enable electron microscopes and diffraction cameras to better resolve the dynamics of reactions in the areas of solid state physics, chemistry, and biology. EOI’s pulse compressor technology utilizes the combination of electron mirror optics and a magnetic beam separator to compress the electron pulse. The design exploits the symmetry inherent in reversing the electron trajectory in the mirror in order to compress the temporally broadened beam. This system also simultaneously corrects the chromatic and spherical aberration of the objective lens for improved spatial resolution. This correction will be found valuable as the source size is reduced with laser-triggered point source emitters. With such emitters, it might be possible to significantly reduce the illuminated area and carry out ultrafast diffraction experiments from small regions of the sample, e.g. from individual grains or nanoparticles. During phase I, EOI drafted a set of candidate pulse compressor architectures and evaluated the trade-offs between temporal resolution and electron bunch size to achieve the optimum design for two particular applications with market potential: increasing the temporal and spatial resolution of UEDs, and increasing the temporal and spatial resolution of DTEMs. Specialized software packages that have been developed by MEBS, Ltd. were used to calculate the electron optical properties of the key pulse compressor components: namely, the magnetic prism, the electron mirror, and the electron lenses. In the final step, these results were folded into a model describing the key electron-optical parameters of the complete pulse compressor. The simulations reveal that the mirror pulse compressor can reduce the temporal spread of UEDs and DTEMs to the sub-100 femtosecond level for practical electron bunch sizes. EOI’s pulse compressors can be designed and built to attach to different types of UEDs and DTEMs, thus making them suitable for enhancing the study of the structure, composition, and bonding states of new materials at ultrafast time scales to advance material science research in the field of nanotechnology as well as biomedical research.

47 OTHER INSTRUMENTATION↗