Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “regression testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Group Projected subspace pursuit for IDENTification of variable coefficient differential equations (GP-IDENT)

We propose an effective and robust algorithm for identifying partial differential equations (PDEs) with space-time varying coefficients from the noisy observation of a single solution trajectory. Identifying unknown differential equations from noisy data is a difficult task, and it is even more challenging with space and time varying coefficients in the PDE. The proposed algorithm, GP-IDENT, has three ingredients: (i) we use B-spline bases to express the unknown space and time varying coefficients, (ii) we propose Group Projected Subspace Pursuit (GPSP) to find a sequence of candidate PDEs with various levels of complexity, and (iii) we propose a new criterion for model selection using the Reduction in Residual (RR) to choose an optimal one among a pool of candidates. The new GPSP considers group projected subspaces which is more robust than existing methods in distinguishing correlated group features. We test GP-IDENT on a variety of PDEs and PDE systems, and compare it with the state-of-the-art parametric PDE identification algorithms under different settings to illustrate its outstanding performance. Furthermore, our experiments show that GP-IDENT is effective in identifying the correct terms from a large dictionary, and our model selection scheme is robust to noise.

Data-driven method↗

Modeling Anti-HIV Activity of HEPT Derivatives Revisited. Multiregression Models Are Not Inferior Ones

Several quantitative structure-activity studies for this data set containing 107 HEPT derivatives have been performed since 1997, using the same set of molecules by (more or less) different classes of molecular descriptors. Multivariate Regression (MR) and Artificial Neural Network (ANN) models were developed and in each study the authors concluded that ANN models are superior to MR ones. We re-calculated multivariate regression models for this set of molecules using the same set of descriptors, and compared our results with the previous ones. Two main reasons for overestimation of the quality of the ANN models in previous studies comparing with MR models are: (1) wrong calculation of leave-one-out (LOO) cross-validated (CV) correlation coefficient for MR models in Luco et al., J. Chem. Inf. Comput. Sci. 37 392-401 (1997), and (2) incorrect estimation/interpretation of leave-one-out (LOO) cross-validated and predictive performance and power of ANN models. More precise and fairer comparison of fit and LOO CV statistical parameters shows that MR models are more stable. In addition, MR models are much simpler than ANN ones. For real testing the predictive performance of both classes of models we need more HEPT derivatives, because all ANN models that presented results for external set of molecules used experimental values in optimization of modeling procedure and model parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine Learning Models to Predict Inhibition of the Bile Salt Export Pump

Cholestatic liver injury is frequently associated with drug inhibition of bile salt transporters, such as the bile salt export pump (BSEP). Reliable in silico models to predict BSEP inhibition directly from chemical structures would significantly reduce costs during drug discovery and could help avoid injury to patients. We report our development of classification and regression models for BSEP inhibition with substantially improved performance over previously published models. We assessed the performance effects of different methods of chemical featurization, data set partitioning, and class labeling and identified the methods producing models that generalized best to novel chemical entities.

59 BASIC BIOLOGICAL SCIENCES↗

Multiple-metal exposure, diet, and oxidative stress in Uruguayan school children

Highlights: • In 6–8 year-old children, we examined associations between urinary concentrations of arsenic, cadmium, and lead, and urinary F{sub 2}–8α isoprostane and 8-hydroxy-2-deoxy-guanosine (8-OHdG). • Even at low-level, each doubling in urinary arsenic concentrations was associated with ~ 10 ng/mL higher 8-OHdG concentratio. • An indicator of mixture of the three metals was associated with higher 8-OHdG concentrations. • We found no effect modification by children's dietary antioxidant intake. Oxidative stress (OS) is an important consequence of exposure to toxic metals but it is unclear to what extent low-level metal exposures contribute to OS in children. We examined the cross-sectional association between urinary concentrations of arsenic (As), cadmium (Cd), and lead (Pb) and urinary markers of OS: F{sub 2}–8α isoprostane and 8-hydroxy-2-deoxy-guanosine (8-OHdG). We also tested effect modification by dietary intakes. Of the 211 children aged 6–8 years living in Montevideo who were eligible for the study because they had at least one OS marker measured via ELISA, 143 were included in a complete-case analysis. Urinary metals were measured with inductively coupled plasma mass spectrometry (ICP-MS: Pb, Cd) and high-performance liquid chromatography online with hydride generation ICP-MS (As-metabolites); concentrations were log{sub 2}-transformed. All urinary markers were adjusted for specific gravity of urine. Two 24-h dietary recalls were conducted to estimate children's dietary intakes, including total fruit and vegetable consumption and vitamin C, zinc and fiber intake. Ordinary least square (OLS) and weighted quantile sum (WQS) regressions were used to estimate the association between metals and each OS marker as outcome. Metal exposure was generally low: median urinary As, Cd, Pb 9.6 μg/L, 0.06 μg/L and 1.9 μg/L, respectively. Median 8-isoprostane concentration was 1.1 and 8-OHdG 39.6 ng/mL. Log{sub 2}-transformed urinary As concentrations were positively associated with 8-OHdG concentrations (10.90 [3.82, 17.97]) in covariate-adjusted OLS models which also took account of exposure to Cd and Pb. In WQS, a mixture index was also associated with higher 8-OHdG (8.71 [1.12, 16.3] for each 25% increase in index value), mostly driven by As exposure. There was little evidence of effect modification by dietary antioxidants. In sum, even at low-level, As exposure is associated with detectable oxidative damage to the DNA.

54 ENVIRONMENTAL SCIENCES↗

Topology optimization of an airfoil fin microchannel heat exchanger using artificial intelligence

High-performance microchannel heat exchangers are needed to supply heat for power conversion for nuclear microreactors. An airfoil fin microchannel design, constructed of Alloy 617 with helium as the working fluid, is analyzed and optimized using a design of experiments with artificial intelligence techniques. The use of airfoil fins offers the potential to reduce pressure drop across the heat exchanger, as compared to other types of channel configurations. A framework for topology optimization of airfoil fin printed circuit heat exchangers (PCHEs) has been developed that can be readily extended to different fin sizes and shapes, as well as different inlet and operating conditions, materials of construction, and working fluids. An optimization procedure is developed that employs computational fluid dynamics for a set of design points identified using Latin hypercube sampling. Computational fluid dynamics is used to analyze a simplified two-channel configuration where five design parameters are varied – inlet angle, fin scale, extent of staggering, transverse and longitudinal pitches. Two methods (a 5D polynomial and a regression neural network) are compared for generating surrogate models and the resulting response surface approximation is input to a genetic algorithm that is used to identify a set of optimal parameters. The optimal geometries are found across six channel Reynolds numbers ranging from 1000 to 5000, since inlet conditions affect flow through the heat exchanger. Additionally, a set of optimal designs that maximizes heat transfer and minimizes pressure drop is identified, and a thermal stress analysis is performed on the optimal design. Correlations for the Nusselt number and Darcy friction factor are developed that can be useful for thermal hydraulic analyses using system codes. Thermal stresses are analyzed and a brief discussion of the status of code cases of PCHEs for nuclear applications is given. Testing and thermomechanical modeling is needed to facilitate future code compliance of PCHEs for high pressure and high temperature applications.

42 ENGINEERING↗

An Artificial Intelligence-Assisted Method for Dementia Detection Using Images from the Clock Drawing Test

Background: Widespread dementia detection could increase clinical trial candidates and enable appropriate interventions. Since the Clock Drawing Test (CDT) can be potentially used for diagnosing dementia-related disorders, it can be leveraged to develop a computer-aided screening tool. Objective: To evaluate if a machine learning model that uses images from the CDT can predict mild cognitive impairment or dementia. Methods: Images of an analog clock drawn by 3,263 cognitively intact and 160 impaired subjects were collected during in-person dementia evaluations by the Framingham Heart Study. We processed the CDT images, participant’s age, and education level using a deep learning algorithm to predict dementia status. Results: When only the CDT images were used, the deep learning model predicted dementia status with an area under the receiver operating characteristic curve (AUC) of 81.3% ± 4.3%. A composite logistic regression model using age, level of education, and the predictions from the CDT-only model, yielded an average AUC and average F1 score of 91.9% ±1.1% and 94.6% ±0.4%, respectively. Conclusion: Our modeling framework establishes a proof-of-principle that deep learning can be applied on images derived from the CDT to predict dementia status. When fully validated, this approach can offer a cost-effective and easily deployable mechanism for detecting cognitive impairment.

Neurosciences & Neurology↗

Active- and transfer-learning applied to microscale-macroscale coupling to simulate viscoelastic flows

Active- and transfer-learning are applied to microscale dynamics of polymer flows for the multiscale discovery of effective constitutive approximations required in viscoelastic flow simulation. The result is macroscopic rheology directly connected to a microstructural model. Micro and macroscale simulations are adaptively coupled by means of Gaussian process regression (GPR) to run the expensive microscale computations only as necessary. This multiscale method is demonstrated with flows of a polymer solution as a model system. At the microscale level dissipative particle dynamics (DPD) is employed to model the fluid as a suspension of bead-spring micro-structures subjected to steady shear flow. The results yield the non-Newtonian viscosity and the first normal stress difference at strain rates as training data used in a GPR model. DPD parameters are calibrated with respect to experimental data for a real polymer solution. Compliance with these data requires adjustment of the DPD model's cutoff radius, which then becomes a function of the second invariant of the strain rate tensor. The FENE-P model is chosen for the macroscale description using the spectral element method (SEM) to simulate channel flow and flow past a circular cylinder. The DPD results at the lowest possible shear strain rate yield an estimate of the zero-shear rate viscosity, which allows the initiation of the macroscale flow by SEM as a Newtonian fluid. The resulting strain-rate field is surveyed to determine additional shear strain rate sampling points for the DPD system. This new information allows an initial fitting of parameters of the constitutive equation followed by new SEM simulations at the macroscale. Additionally, guided by active-learning GPR to select new sampling points, this process continues until convergence is achieved. The effectiveness of this new simulation paradigm for viscoelastic flows is tested with different macroscale operating conditions. The effective closure learned in the channel simulation is then transferred directly to the flow past a circular cylinder at low Reynolds number, where the results show that only two additional DPD simulations are required to achieve a satisfactory constitutive model. With an increase of the Reynolds number, the active-learning scheme automatically detects the inaccuracy of the learned constitutive model, and initiates additional DPD simulations for the extra data needed to once again close the microscale-macroscale coupled system. This new paradigm of active- and transfer-learning for multiscale modeling is readily applicable to other microscale-macroscale coupled simulations of complex fluids and other materials. Furthermore, the coupling between microscale and macroscale solvers can be seamlessly implemented with our open source multiscale universal interface (MUI) library.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using diverse potentials and scoring functions for the development of improved machine-learned models for protein–ligand affinity and docking pose prediction

The advent of computational drug discovery holds the promise of significantly reducing the effort of experimentalists, along with monetary cost. More generally, predicting the binding of small organic molecules to biological macromolecules has far-reaching implications for a range of problems, including metabolomics. However, problems such as predicting the bound structure of a protein–ligand complex along with its affinity have proven to be an enormous challenge. In recent years, machine learning-based methods have proven to be more accurate than older methods, many based on simple linear regression. Nonetheless, there remains room for improvement, as these methods are often trained on a small set of features, with a single functional form for any given physical effect, and often with little mention of the rationale behind choosing one functional form over another. Moreover, it is not entirely clear why one machine learning method is favored over another. Here, we endeavor to undertake a comprehensive effort towards developing high-accuracy, machine-learned scoring functions, systematically investigating the effects of machine learning method and choice of features, and, when possible, providing insights into the relevant physics using methods that assess feature importance. Here, we show synergism among disparate features, yielding adjusted R 2 with experimental binding affinities of up to 0.871 on an independent test set and enrichment for native bound structures of up to 0.913. When purely physical terms that model enthalpic and entropic effects are used in the training, we use feature importance assessments to probe the relevant physics and hopefully guide future investigators working on this and other computational chemistry problems.

59 BASIC BIOLOGICAL SCIENCES↗

Correcting for filter-based aerosol light absorption biases at the Atmospheric Radiation Measurement program's Southern Great Plains site using photoacoustic measurements and machine learning

Abstract. Measurement of light absorption of solar radiation by aerosols is vital for assessing direct aerosol radiative forcing, which affects local and global climate. Low-cost and easy-to-operate filter-based instruments, such as the Particle Soot Absorption Photometer (PSAP), that collect aerosols on a filter and measure light attenuation through the filter are widely used to infer aerosol light absorption. However, filter-based absorption measurements are subject to artifacts that are difficult to quantify. These artifacts are associated with the presence of the filter medium and the complex interactions between the filter fibers and accumulated aerosols. Various correction algorithms have been introduced to correct for the filter-based absorption coefficient measurements toward predicting the particle-phase absorption coefficient (Babs). However, the inability of these algorithms to incorporate into their formulations the complex matrix of influencing parameters such as particle asymmetry parameter, particle size, and particle penetration depth results in prediction of particle-phase absorption coefficients with relatively low accuracy. The analytical forms of corrections also suffer from a lack of universal applicability: different corrections are required for rural and urban sites across the world. In this study, we analyzed and compared 3 months of high-time-resolution ambient aerosol absorption data collected synchronously using a three-wavelength photoacoustic absorption spectrometer (PASS) and PSAP. Both instruments were operated on the same sampling inlet at the Department of Energy's Atmospheric Radiation Measurement program's Southern Great Plains (SGP) user facility in Oklahoma. We implemented the two most commonly used analytical correction algorithms, namely, Virkkula (2010) and the average of Virkkula (2010) and Ogren (2010)–Bond et al. (1999) as well as a random forest regression (RFR) machine learning algorithm to predict Babs values from the PSAP's filter-based measurements. The predicted Babs was compared against the reference Babs measured by the PASS. The RFR algorithm performed the best by yielding the lowest root mean square error of prediction. The algorithm was trained using input datasets from the PSAP (transmission and uncorrected absorption coefficient), a co-located nephelometer (scattering coefficients), and the Aerosol Chemical Speciation Monitor (mass concentration of non-refractory aerosol particles). A revised form of the Virkkula (2010) algorithm suitable for the SGP site has been proposed; however, its performance yields approximately 2-fold errors when compared to the RFR algorithm. To generalize the accuracy and applicability of our proposed RFR algorithm, we trained and tested it on a dataset of laboratory measurements of combustion aerosols. Input variables to the algorithm included the aerosol number size distribution from the Scanning Mobility Particle Sizer, absorption coefficients from the filter-based Tricolor Absorption Photometer, and scattering coefficients from a multiwavelength nephelometer. The RFR algorithm predicted Babs values within 5 % of the reference Babs measured by the multiwavelength PASS during the laboratory experiments. Thus, we show that machine learning approaches offer a promising path to correct for biases in long-term filter-based absorption datasets and accurately quantify their variability and trends needed for robust radiative forcing determination.

54 ENVIRONMENTAL SCIENCES↗

Antarctic polar stratospheric aerosols: The roles of nitrates, chlorides and sulfates

Nitric and hydrochloric acids have been postulated to condense in the winter polar stratosphere to become an important component of polar stratospheric clouds. One implication is that the removal of NO(y) from the gas phase by this mechanism allows high Cl(x) concentrations to react with O3, because the formation of ClNO3 is inhibited. Contributions of NO3 and Cl to the stratospheric aerosol were determined during the 1987 Airborne Antarctic Ozone Experiment by testing for the presence of nitrates and chlorides in the condensed phase. Aerosol particles were collected on four 500 micron diameter gold wires, each pretreated differently to give results that were specific to certain physical and chemical aerosol properties. One wire was carbon-coated for concentration and size analyses by scanning electron microscopy; X-ray energy dispersive analyses permitted the detection of S and Cl in individual particles. Three more wires were coated with Nitron, barium chloride and silver nitrate, respectively, to detect nitrate, sulfate and chloride in aerosol particles. All three ions, viz., sulfates, nitrates and chlorides were detected in the Antarctic stratospheric aerosol. In terms of number concentrations, the aerosol was dominated by sulfates, followed by chlorides and nitrates. An inverse linear regression can be established between nitrate concentrations and ozone mixing ratio, and between temperature and nitrates.

Pueschel, R. F.↗

Temperature and vital effect controls on Bamboo coral (Isididae) isotopegeochemistry: A test of the "lines method"

Deep-sea bamboo corals hold promise as long-term climatic archives, yet little information exists linking bamboo coral geochemistry to measured environmental parameters. This study focuses on a suite of 10 bamboo corals collected from the Pacific and Atlantic basins (250-2136 m water depth) to investigate coral longevity, growth rates, and isotopic signatures. Calcite samples for stable isotopes and radiocarbon were collected from the base the corals, where the entire history of growth is recorded. In three of the coral specimens, samples were also taken from an upper branch for comparison. Radiocarbon and growth band width analyses indicate that the skeletal calcite precipitates from ambient dissolved inorganic carbon and that the corals live for 150-300 years, with extension rates of 9-128 {micro}m/yr. A linear relationship between coral calcite {delta}{sup 18}O and {delta}{sup 13}C indicates that the isotopic composition is influenced by vital effects ({delta}{sup 18}O:{delta}{sup 13}C slope of 0.17-0.47). As with scleractinian deep-sea corals, the intercept from a linear regression of {delta}{sup 18}O versus {delta}{sup 13}C is a function of temperature, such that a reliable paleotemperature proxy can be obtained, using the 'lines method.' Although the coral calcite {delta}{sup 18}O:{delta}{sup 13}C slope is maintained throughout the coral base ontogeny, the branches and central cores of the bases exhibit {delta}{sup 18}O:{delta}{sup 13}C values that are shifted far from equilibrium. We find that a reliable intercept value can be derived from the {delta}{sup 18}O:{delta}{sup 13}C regression of multiple samples distributed throughout one specimen or from multiple samples within individual growth bands.

58 GEOSCIENCES↗

Identifying Differential Equations in Fourier Domain (FourierIdent)

We investigate identifying differential equations in the frequency domain. Fourier analysis is an important tool in theoretical analysis and numerical solvers of differential equations, yet there is limited work in exploring this connection in the identification of differential equations. This paper aims to identify the underlying differential equation in the frequency domain, from a given single realization of the differential equation perturbed by noise. Such setting imposes difficulties which are different from other identification methods where computation is carried out in the physical domain. We propose several ways to mitigate the challenges arising from noise in data and large differences in the magnitudes of frequency responses. The main takeaways are that identifying differential equations solely in the frequency domain is challenging, the method we propose is based on a form of domain partitions in the frequency domain, and this method shows benefits for complex data even with high level of noise. We introduce a Fourier feature denoising, and define the meaningful data region and the core regions of features to reduce the effect of noise in the frequency domain and to enhance the accuracy in coefficient identification. The proposed method is tested on various differential equations with linear, nonlinear, and high-order derivative feature terms, and shows advantages on complex data with many frequency modes, even under high level of noise.

97 MATHEMATICS AND COMPUTING↗

A machine learning approach to fracture mechanics problems

Analytical and empirical solutions to engineering problems are usually preferred because of their convenience in applications. However, they are not always accessible in complex problems. A new class of solutions, based on machine learning (ML) models such as regression trees and neural networks (NNs), are proposed and their feasibility and value are demonstrated through the analysis of fracture toughness measurements. It is found that both solutions based on regression trees and NNs can provide accurate results for the specific problem, but NN-based solutions outperform regression-tree-based solutions in terms of their simplicity. Here this example demonstrates that ML solutions are a major improvement over analytical and empirical solutions in terms of both reliable functionality and rapid deployment. When analytical solutions are not available, the use of ML solutions can overcome the limitations of empirical solutions and substantially change the way that engineering problems are solved.

36 MATERIALS SCIENCE↗

Optimal Stimulus Amplitude for Vestibular Stochastic Stimulation to Improve Sensorimotor Function

Sensorimotor changes such as postural and gait instabilities can affect the functional performance of astronauts when they transition across different gravity environments. We are developing a method, based on stochastic resonance (SR), to enhance information transfer by applying non-zero levels of external noise on the vestibular system (vestibular stochastic resonance, VSR). Our previous work has shown the advantageous effects of VSR in a balance task of standing on an unstable surface. This technique to improve detection of vestibular signals uses a stimulus delivery system that is wearable or portable and provides imperceptibly low levels of white noise-based binaural bipolar electrical stimulation of the vestibular system. The goal of this project is to determine optimal levels of stimulation for SR applications by using a defined vestibular threshold of motion detection. A series of experiments were carried out to determine a robust paradigm to identify a vestibular threshold that can then be used to recommend optimal stimulation levels for SR training applications customized to each crewmember. Customizing stimulus intensity can maximize treatment effects. The amplitude of stimulation to be used in the VSR application has varied across studies in the literature such as 60% of nociceptive stimulus thresholds. We compared subjects' perceptual threshold with that obtained from two measures of body sway. Each test session was 463s long and consisted of several 15s sinusoidal stimuli, at different current amplitudes (0-2 mA), interspersed with 20-20.5s periods of no stimulation. Subjects sat on a chair with their eyes closed and had to report their perception of motion through a joystick. A force plate underneath the chair recorded medio-lateral shear forces and roll moments. First we determined the percent time during stimulation periods for which perception of motion (activity above a pre-defined threshold) was reported using the joystick, and body sway (two standard deviation of the noise level in the baseline measurement) was detected by the sensors. The percentage time at each stimulation level for motion detection was normalized with respect to the largest value and a logistic regression curve fit was applied to these data. The threshold was defined at the 50% probability of motion detection. Comparison of threshold of motion detection obtained from joystick data versus body sway suggests that perceptual thresholds were significantly lower, and were not impacted by system noise. Further, in order to determine optimal stimulation amplitude to improve balance, two sets of experiments were carried out. In the first set of experiments, all subjects received the same level of stimuli and the intensity of optimal performance was projected back on subjects' vestibular threshold curve. In the second set of experiments, on different subjects, stimulation was administered from 20-400% of subjects' vestibular threshold obtained from joystick data. Preliminary results of our study show that, in general, using stimulation amplitudes at 40-60% of perceptual motion threshold improved balance performance significantly compared to control (no stimulation). The amplitude of vestibular stimulation that improved balance function was predominantly in the range of +/- 100 to +/- 400 micro A. We hypothesize that VSR stimulation will act synergistically with sensorimotor adaptability (SA) training to improve adaptability by increasing utilization of vestibular information and therefore will help us to optimize and personalize a SA countermeasure prescription. This combination will help to significantly reduce the number of days required to recover functional performance to preflight levels after long-duration spaceflight.

Goel, R.↗

Identification and Quantification of Carbon Phases in Conversion Fuel for the Transient Reactor Test Facility

As part of an overall effort to convert US research reactors to low-enriched uranium (LEU) fuel, a LEU conversion fuel is being designed for the Transient Reactor Test Facility (TREAT) at the Idaho National Laboratory. TREAT fuel compacts are comprised of UO{sub 2} fuel particles in a graphitic matrix material. In order to refine heat transfer modeling, as well as determine other physical and nuclear characteristics of the fuel, the amount and type of graphite and non-graphite phases within the fuel matrix must be known. In this study, we performed a series of complementary analyses, designed to allow detailed characterization of the graphite and phenolic resin based fuel matrix. Methods included Scanning Electron Microscopy, Raman spectroscopy, and X-ray Diffraction. Our results indicate that no single characterization technique will yield all of the desired information; however, through the use of statistical and empirical data analysis, such as curve fitting, partial least squares regression, volume extrapolation and spectra peak ratios, a degree of certainty for the quantity of each phase can potentially be obtained. Although no one type of analysis has provided a complete determination of the quantities and identities of all carbon phases present in the fuel matrix, additional information has been gathered and is being used to refine future analysis methods. From the three types of quantification performed, results have been within 1% (92.8%, 93.02% and 93.6% for BSE image analysis, XRD and Raman spectroscopy, respectively). More work remains to identify any trace crystalline carbonaceous phases that may be present, quantify any traces that are identified, and develop and use further complementary bulk phase quantification techniques. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NEON AOP foliar trait maps, maps of model uncertainty estimates, and conifer map, East River, CO 2018

This data package contains mapped trait estimates and their uncertainties, and conifer map, for the National Ecological Observatory Network's Airborne Observation Platform survey data acquired over the Upper East River, Colorado in 2018. For full details, please see associated reference. in brief, trait models were developed independently for needle and non-needle leaf species using partial least squares regression (PLSR) using ground data from additional datasets: doi:10.15485/1618130, doi:10.15485/1618132, and doi:10.15485/1631278, merged with extracted spectral data from doi:10.15485/1618131. We separated vegetated pixels into needle and non-needle classes in order to generate a classification map based on the spectral differences between these leaf types (conifer.tif). We trained a deep learning model with custom architecture, detailed in Chadwick et al. In Press. The model performed with 0.998 true positive rate and 0.982 true negative rate, with ‘positives’ being non-needle identification. We then utilized PLSR to generate models of foliar traits for each leaf type. So that we could also map uncertainty in these predictions, we generated ten different models for needle and non-needle leaf species using different testing holdout sets of discrete sites. Each of these models was developed with a 100-fold cross validation procedure that utilized a 70% training set and 30% validation set with each fold, and then assessed based on the 10% of testing sites that were not included in that model’s development. The mean predicted value across the 10 models is used for the trait estimate in each pixel across the study area. The models are applied according to the leaf type designation in the conifer.tif map. The errors are the standard deviation across the 10 different models developed, with high error suggesting instability in model prediction and areas where values may not be reliable for ecological inference. These maps are only applied to areas with a NDVI > 0.5 to exclude non-vegetated areas. Shade masks could be applied to these data (doi:10.15485/1618131), but have not been for this data package. These data are also available on Google Earth Engine: https://code.earthengine.google.com/?asset=users/kdc/ER_NEON

54 ENVIRONMENTAL SCIENCES↗

Method for Measuring Thermal Conductivity of Small Samples Having Very Low Thermal Conductivity

This paper describes the development of a hot plate method capable of using air as a standard reference material for the steady-state measurement of the thermal conductivity of very small test samples having thermal conductivity on the order of air. As with other approaches, care is taken to ensure that the heat flow through the test sample is essentially one-dimensional. However, unlike other approaches, no attempt is made to use heated guards to block the flow of heat from the hot plate to the surroundings. It is argued that since large correction factors must be applied to account for guard imperfections when sample dimensions are small, it may be preferable to simply measure and correct for the heat that flows from the heater disc to directions other than into the sample. Experimental measurements taken in a prototype apparatus, combined with extensive computational modeling of the heat transfer in the apparatus, show that sufficiently accurate measurements can be obtained to allow determination of the thermal conductivity of low thermal conductivity materials. Suggestions are made for further improvements in the method based on results from regression analyses of the generated data.

Miller, Robert A.↗

Accuracy and Utility of Deformable Image Registration in {sup 68}Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: {sup 68}Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration. Conclusions: DIR accuracy in the data sets studied was variable depending on anatomic changes resulting from radiation therapy; caution must be exercised when using DIR in regions of low contrast or radiation pneumonitis. Lung perfusion reduces with increasing radiation therapy dose; however, DIR did not translate into significant changes in dose–response assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗