Stimulated Raman emission in liquids.
Angular emission properties of stimulated Raman radiation from liquids, noting two classes of radiation
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Angular emission properties of stimulated Raman radiation from liquids, noting two classes of radiation
Two-phonon Raman scattering in cubic crystals, noting use of polarization effect to determine active irreducible representations
Vibrational spectrum of liquid, solid and gaseous tetradeuterated hydrazine and Raman study of hydrogen bonding in hydrazine
Calculation method for true profile of Raman lines
Stimulated Raman effects in anisotropic crystal potassium dihydrogen phosphate with Stokes generations
Electric field enhanced Raman scattering and linear frequency shift of strontium titanate soft mode in random domain orientation and reorientation
Stimulated Raman scattering in IR active nontotally symmetric vibration of alpha quartz crystal, noting parametric oscillation
We have elecited a reliable glucose signature in mammalian physiological ranges using near infrared Raman laser excitation at 785 nm and multivariate analysis. In a recent series of experiments we measured glucose levels in an artificial aqueous humor in the range from 0.5 to 13X normal values.
This article describes the development of hollow cathode ion lasers and their use in constructing an ultraviolet micro-Raman spectrograph with native fluorescence imaging capability.
We have elicited a reliable Raman spectral signature for glucose in rabbit aqueous humor across mammalian physiological ranges in a rabbit model stressed by recent myocardial infarction.
ABSTRACT A new monitoring system was developed at Pacific Northwest National Laboratory (PNNL) to quickly generate real-time data/analysis to facilitate a timely response to the dynamic characteristics of a radioactive high level waste stream. The developed process monitor features Raman and Coriolis/conductivity instrumentation configured for the remote monitoring, MatLab-based chemometric data processing, and comprehensive software for data acquisition/storage/archiving/display. The monitoring system is capable of simultaneously and continuously quantifying the levels of all the chemically significant anions within the waste stream including nitrate, nitrite, phosphate, carbonate, chromate, hydroxide, sulfate, and aluminate. The total sodium ion concentration was also determined independently by modeling inputs from on-line conductivity and density meters. In addition to the chemical information, this monitoring system provides immediate real-time data on the flow parameters, such as flow rate and temperature, and cumulative mass/volume of the retrieved waste stream. The components and analytical tools of the new process monitor can be tailored for a variety of complex mixtures in chemically harsh environments, such as pulp and paper processing liquids, electroplating solutions, and radioactive tank wastes. The developed monitoring system was tested for acceptability before it was deployed for use in Hanford Tank S-109 retrieval activities. The acceptance tests included performance inspection of hardware, software, and chemometric data analysis to determine the expected measurement accuracy for the different chemical species that are encountered during S-109 retrieval.
Cerussite (PbCO{sub 3}) has been investigated by high-pressure and high-temperature Raman spectroscopy up to pressures of 17.2 GPa and temperatures of 723 K. Two pressure induced phase transitions were observed at about 8.0(2) and 16.0(2) GPa, respectively. The post-aragonite transition (PbCO{sub 3}-II) at 8.0(2) GPa is accompanied by softening of the v 2-out-of-plane mode of the CO{sub 3}{sup 2-} group and disappearance of the B{sub 1g} (v{sub 4}-in-plane band of the CO{sub 3}{sup 2-} group) mode. Stronger shifts of the carbonate group modes after the phase transition suggest that the new structure is more compressible. The formation of a second high-pressure polymorph begins at about 10 GPa. It is accompanied by the occurrence of three new bands at different pressures and splitting of the v{sub 1}-symmetric C-O stretching mode of the CO{sub 3}{sup 2-} group. The transitions are reversible on pressure release. A semi-quantitative phase diagram for PbCO{sub 3} as a function of pressure and temperature is proposed.
The miniaturization of in situ spectroscopic tools has been recognized as a forefront instrumental development for the characterization of heterogeneous catalysts. With the multitude of micro-spectroscopic methods available fundamental insight into the structure-function relationships of catalytic processes can be obtained. Among these techniques vibrational spectroscopy is one of the most versatile methods and capable to shed insight into the molecular structure of reaction intermediates and products, the chemical state of catalyst materials during reaction as well as the nature of interactions between reactants/intermediates/products and the catalyst surface. In this tutorial review we discuss the recent developments in the field of infrared (IR) and Raman micro-spectroscopy and illustrate their potential. Showcase examples include (1) chemical imaging of spatial heterogeneities during catalyst preparation, (2) high-throughput catalyst screening, (3) transport and adsorption phenomena within catalytic solids and (4) reactivity studies of porous oxides, such as zeolites. Finally, new in situ spectroscopy tools based on vibrational spectroscopy and their potential in the catalysis domain are discussed.
Herein, we utilize surface enhanced Raman spectroscopy (SERS) for the in situ analyses of catalyst structure while operating at elevated temperatures in various atmospheres. In order to accomplish this, robust SERS substrates were generated by depositing an ultrathin protective coating of alumina on top of silver nanowires (NWs) via atomic layer deposition (ALD). In situ studies were then conducted by analyzing the effects of heating a solid acid, phosphotungstic acid (PTA), on the alumina surface in either an oxygen or hydrogen environment at temperatures up to 400 C. Interestingly, the distance-dependent decay of the enhancement factor of the SERS signal from the underlying NWs allowed us to probe with great detail the interfacial region between the PTA and the alumina surface. The ability to analyze the area closest to the alumina surface was further confirmed by assembling vanadia onto the substrate and monitoring the intensity differences between the V-O-Al and outer V = O bonds.
This presentation describes a temperature measurement technique entirely different from the traditional pyrometry method normally used in shock wave measurements. The new technique, based on Raman spectroscopy, does not depend on surface emissivity and provides an independent way of measuring temperature.
The demand for Hanford waste property analysis is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward transferring waste to the Hanford Waste Treatment and Immobilization Plant. The analysis of waste includes chemical, radionuclide, and physical property characterizations, with the goal of achieving safe/informed transfer and processing. Waste sampling followed by offline laboratory analysis is the current baseline analytical approach. The addition of field-deployed/in situ instruments has the potential to provide improvements and benefits over offline analysis in the areas of 1) Worker Safety: by reducing the need for sampling and thereby reducing the need for worker interaction with waste during sample handling; 2) Operational Efficiency: by reducing analysis turnaround times and offsetting demand on analytical laboratories; and 3) Accuracy: continuous analysis of a flowing waste stream allows cumulative results to be produced for the batch, which is more representative than discrete samples of batch properties. This paper describes the development and application of an online monitor to provide chemical characterizations; specifically, Raman spectroscopy is utilized to identify and quantify tank components. Accurate quantification is achieved through the use of chemometric analysis, which can be configured to provide real-time analysis in field deployment settings. (authors)
This paper presents the use of in situ monitoring tools for molecular analysis of non-radioactive species found in the supernatant liquid and dissolvable salt cake of nuclear waste at Hanford. We have selected two in situ spectroscopic techniques that do not require any sample preparation or consumables: infrared (in the form of attenuated total reflectance Fourier transform infrared or ATR-FTIR) and Raman spectroscopy. This work aims to evaluate their performance for liquid waste simulants representative of the Hanford DFLAW (Direct Feed Low-Activity Waste) feed. In addition, we have evaluated the performance of four multivariate linear models that extract concentrations from spectral measurements for a data set that was designed to include key molecular species found in liquid low-activity waste. (authors)
The advancement of microfluidics and lab-on-a-chip designs has provided a pathway of experimentation that utilizes volumes which are orders of magnitude less than previous techniques. For radioactive applications the benefits of lower dose to workers and equipment, smaller feedstock volumes, and less waste make these techniques of significant interest. With these benefits come the complication of solution analysis, as conventional spectroscopic techniques require much larger volumes. Therefore to meet this need a Micro Raman has been developed with a focal point capable of solution analysis inside a channel on a microfluidic chip. The system has been applied and validated with solutions relevant to nuclear fuel applications. (authors)