Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microscopy analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Gas delivery system for environmental transmission electron microscope

A portable, compact gas delivery system can support an environmental transmission electron microscope. Environment transmission electron microscopy provides researchers a unique capability of assessing a material's surface conditions at atomic resolution in a variety of reactive and oxidizing environments. The ability to precisely control the analysis chamber's environmental conditions over time is key to the success of a typical surface analysis. The gas delivery system provides the correct balance or pressure delivery precision, contamination control, and gas isolation.

Nogan, John Joseph↗

Proposed Analytical Methods for Determining Filter Media Properties

High Efficiency Particulate Air (HEPA) filters, commonly used in nuclear filtration applications, are an integral part of the waste management processes in nuclear plants. HEPA filters are 99.97% efficient filtration devices characterized by their high resistance to air flow, or pressure drop. From theoretical models, the initial pressure drop across a clean filter is proven to be a function of the filter media fiber diameters and porosity of the media. These filter properties are relatively difficult to obtain with traditional manual methods; therefore, there is a need to develop analytical methods to find the fiber diameter and porosity to determine the pressure drop. Typically, these values can be found by substituting a calculated representative value based upon measured values, such as equivalent fiber diameter based upon a clean pressure drop. However, these values may also be directly recorded and measured by incorporating Scanning Electron Microscope (SEM) image analysis and other measurement methods to analyze the filter media and determine its physical properties without the need for media testing. DiameterJ, an open source Java plug-in, used with ImageJ, can process images of filter media taken by an SEM to find statistical data such as mean fiber diameter and porosity. To produce the raw data, SEM images of two filter media type samples are taken and segmented in DiameterJ using the traditional and statistical region merging segmentation algorithms. Manual segmentation is necessary after the initial segmentation by the algorithms as the images tend to be too complex for the algorithms to output with the necessary accuracy. However, complications exist in the manual segmentation process as these methods can be time intensive and prone to the individual bias of the user. This in turn can skew the final mean fiber diameter result, and lead to either an over or under prediction of the pressure drop. It was also discovered that the porosity data produced by DiameterJ is inaccurate, as the SEM analyzes the three-dimensional filter media by projecting its geometry onto a plane and analyzing it as a two-dimensional binary image. Thus, the porosity is artificially inflated through the segmentation process, rendering this result incorrect. Alternatively, density determination, gravimetric analysis, and thickness testing of the filter media is collectively used to determine the filter fiber porosity. Together, the SEM image analysis and analytical lab methods produce results through direct measurements which allow for the prediction of the initial pressure drop from clean filter media without the need for prior media testing to collect pressure data. By improving upon this proposed analytical method in the future, there is potential to streamline the process of finding these filter properties into a more direct methodology for determining the pressure drop across HEPA filters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Core Characterization of Bakken Shale from the Bedwell 33-52-1-1H Well, Sheridan County, Montana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core of the Bedwell 33-52-1-1H well (API 25-091-21920), a wildcat field in Sheridan County, Montana. The primary impetus of this work is to provide a unique dataset to researchers at universities, national laboratories, geological surveys, and other locations for additional analyses. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/bedwell-33-52-1-1h-well. The equipment and techniques used to characterize the full core were non-destructive, enabling future examinations and analyses to be performed on these cores. However, none of the equipment used was suitable for direct visualization of the pore space in fine-grained structures such as those found in shales; fractures, discontinuities, and millimeter scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. A selection of samples (Table 1) were cored, sliced, and powdered for additional characterization analyses. These analyses did involve destructive subsampling of the full core at discrete sections, and the results are presented here in the context of the larger core description. Selected sections of the core were removed from the full core for detailed analyses using the following destructive techniques: bulk inductively coupled plasma-optical emission spectroscopy (ICP-OES), isolation of carbon and sulfur, Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM), and higher resolution CT scan with NETL’s micro-CT scanning systems. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

04 OIL SHALES AND TAR SANDS↗

Morphologically-Directed Raman Spectroscopy as an Analytical Method for Subvisible Particle Characterization in Therapeutic Protein Product Quality

Abstract Subvisible particles (SVPs) are a critical quality attribute of injectable therapeutic proteins (TPs) that needs to be controlled due to potential risks associated with drug product quality. The current compendial methods routinely used to analyze SVPs for lot release provide information on particle size and count. However, chemical identification of individual particles is also important to address root-cause analysis. Herein, we introduce Morphologically-Directed Raman Spectroscopy (MDRS) for SVP characterization of TPs. The following particles were used for method development: (1) polystyrene microspheres, a traditional standard used in industry; (2) photolithographic (SU-8); and (3) ethylene tetrafluoroethylene (ETFE) particles, candidate reference materials developed by NIST. In our study, MDRS rendered high-resolution images for the ETFE particles (> 90%) ranging from 19 to 100 μm in size, covering most of SVP range, and generated comparable morphology data to flow imaging microscopy. Our method was applied to characterize particles formed in stressed TPs and was able to chemically identify individual particles using Raman spectroscopy. MDRS was able to compare morphology and transparency properties of proteinaceous particles with reference materials. The data suggests MDRS may complement the current TPs SVP analysis system and product quality characterization workflow throughout development and commercial lifecycle.

Science & Technology - Other Topics↗

Analysis of X-ray images and spectra (aXis2000): A toolkit for the analysis of X-ray spectromicroscopy data

Spectromicroscopy refers to analytical methods that combine imaging and spectroscopy to provide detailed, spatially resolved analytical information about a sample, such as the type and quantitative spatial distributions of chemical components, geometric or magnetic alignment information, crystal structure, etc. The analysis of X-ray images and spectra (aXis2000) software described in this work provides a set of routines within a single, integrated, graphical-oriented package to read, display, manipulate and analyze spectromicroscopy data, with particular focus on soft X-ray spectromicroscopy methods such as scanning transmission X-ray microscopy (STXM), X-ray photoemission electron microscopy (XPEEM), scanning photoelectron X-ray microscopy (SPEM) and transmission X-ray microscopy (TXM). Here, this free software is described and compared to other software that can provide similar or complementary capabilities. Examples of spectromicroscopic analyses using advanced features of aXis2000 are provided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of biofilm assembly by large area automated AFM

Biofilms are complex microbial communities critical in medical, industrial, and environmental contexts. Understanding their assembly, structure, genetic regulation, interspecies interactions, and environmental responses is key to developing effective control and mitigation strategies. While atomic force microscopy (AFM) offers critically important high-resolution insights on structural and functional properties at the cellular and even sub-cellular level, its limited scan range and labor-intensive nature restricts the ability to link these smaller scale features to the functional macroscale organization of the films. We begin to address this limitation by introducing an automated large area AFM approach capable of capturing high-resolution images over millimeter-scale areas, aided by machine learning for seamless image stitching, cell detection, and classification. Large area AFM is shown to provide a very detailed view of spatial heterogeneity and cellular morphology during the early stages of biofilm formation which were previously obscured. Using this approach, we examined the organization of Pantoea sp. YR343 on PFOTS-treated glass surfaces. Our findings reveal a preferred cellular orientation among surface-attached cells, forming a distinctive honeycomb pattern. Detailed mapping of flagella interactions suggests that flagellar coordination plays a role in biofilm assembly beyond initial attachment. Additionally, we use large-area AFM to characterize surface modifications on silicon substrates, observing a significant reduction in bacterial density. This highlights the potential of this method for studying surface modifications to better understand and control bacterial adhesion and biofilm formation.

59 BASIC BIOLOGICAL SCIENCES↗

Microchemical analysis of the SCS-6 silicon carbide fiber

A detailed quantitative study of the microstructural variation of chemical composition of chemically vapor-deposited commercial SiC SCS-6 fiber is presented. Chemical etching and various electron-optical techniques including SEM, TEM, scanning Auger microscopy, AES, and parallel electron energy loss spectroscopy are used to analyze the chemical composition of the as-received fiber. In addition, some results on stereology of the high-temperature annealed fiber are presented. The results show that the carbon-to-silicon atom ratio in the SiC layers decreases in a stepwise fashion from about 3:2 to about 1:1 in going from the innermost layer to the outermost layer.

Ning, Xian-Jie↗

Multispectral Imaging Broadens Cellular Analysis

Amnis Corporation, a Seattle-based biotechnology company, developed ImageStream to produce sensitive fluorescence images of cells in flow. The company responded to an SBIR solicitation from Ames Research Center, and proposed to evaluate several methods of extending the depth of field for its ImageStream system and implement the best as an upgrade to its commercial products. This would allow users to view whole cells at the same time, rather than just one section of each cell. Through Phase I and II SBIR contracts, Ames provided Amnis the funding the company needed to develop this extended functionality. For NASA, the resulting high-speed image flow cytometry process made its way into Medusa, a life-detection instrument built to collect, store, and analyze sample organisms from erupting hydrothermal vents, and has the potential to benefit space flight health monitoring. On the commercial end, Amnis has implemented the process in ImageStream, combining high-resolution microscopy and flow cytometry in a single instrument, giving researchers the power to conduct quantitative analyses of individual cells and cell populations at the same time, in the same experiment. ImageStream is also built for many other applications, including cell signaling and pathway analysis; classification and characterization of peripheral blood mononuclear cell populations; quantitative morphology; apoptosis (cell death) assays; gene expression analysis; analysis of cell conjugates; molecular distribution; and receptor mapping and distribution.

Source record↗

Imaging Phase Segregation in Nanoscale Li x CoO 2 Single Particles

Li x CoO 2 (LCO) is a common battery cathode material that has recently emerged as a promising material for other applications including electrocatalysis and as electrochemical random access memory (ECRAM). During charge– discharge cycling LCO exhibits phase transformations that are significantly complicated by electron correlation. While the bulk phase diagram for an ensemble of battery particles has been studied extensively, it remains unclear how these phases scale to nanometer dimensions and the effects of strain and diffusional anisotropy at the single-particle scale. Understanding these effects is critical to modeling battery performance and for predicting the scalability and performance of electrocatalysts and ECRAM. Here we investigate isolated, epitaxial LiCoO 2 islands grown by pulsed laser deposition. After electrochemical cycling of the islands, conductive atomic force microscopy (c-AFM) is used to image the spatial distribution of conductive and insulating phases. Above 20 nm island thicknesses, we observe a kinetically arrested state in which the phase boundary is perpendicular to the Li-planes; we propose a model and present image analysis results that show smaller LCO islands have a higher conductive fraction than larger area islands, and the overall conductive fraction is consistent with the lithiation state. Thinner islands (14 nm), with a larger surface to volume ratio, are found to exhibit a striping pattern, which suggests surface energy can dominate below a critical dimension. When increasing force is applied through the AFM tip to strain the LCO islands, significant shifts in current flow are observed, and underlying mechanisms for this behavior are discussed. The c-AFM images are compared with photoemission electron microscopy images, which are used to acquire statistics across hundreds of particles. Finally, the results indicate that strain and morphology become more critical to electrochemical performance as particles approach nanometer dimensions.

25 ENERGY STORAGE↗

Unraveling the Unconventional Order of a High-Mobility Indacenodithiophene-Benzothiadiazole Copolymer

We report a new class of donor–acceptor (D-A) copolymers found to produce high charge carrier mobilities competitive with amorphous silicon (>1 cm 2 V –1 s –1 ) exhibit the puzzling microstructure of substantial local order, however lacking long-range order and crystallinity previously deemed necessary for achieving high mobility. Here, we demonstrate the application of low-dose transmission electron microscopy to image and quantify the nanoscale and mesoscale organization of an archetypal D-A copolymer across areas comparable to electronic devices (≈9 μm 2 ). The local structure is spatially resolved by mapping the backbone (001) spacing reflection, revealing nanocrystallites of aligned polymer chains throughout nearly the entire film. Analysis of the nanoscale structure of its ordered domains suggests significant short- and medium-range order and preferential grain boundary orientations. Moreover, we provide insights into the rich, interconnected mesoscale organization of this new family of D-A copolymers by analysis of the local orientational spatial autocorrelations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of secondary gas-phase reactions (SGR) in pyrolysis of carbon feedstocks for anisotropic carbon materials production – 1: Controlling SGR to modify intermediate coal tar species to improve pitch anisotropy

To meet the increasing demand for graphitizable carbon products, such as needle coke and carbon fiber, more carbon feedstocks capable of forming anisotropy should be utilized. Non-coking coals are widely available but are not typically suitable for producing anisotropic carbons due to lacking proper coal chemistry. This work used secondary gas-phase reactions (SGR) during coal pyrolysis to improve the coal tar chemistry of a non-coking coal for anisotropic carbon production. SGR pyrolysis temperatures and residence times were varied (T = 800–900°C and τ = 0–2.5 s), and analysis of the intermediate coal tar products showed that as these SGR pyrolysis conditions increased, the oxygen and aliphatic concentrations decreased, whereas aromatic contents and molecular weights increased. Without any SGR, microscopy of the thermally-treated coal tar pitch product revealed that the coal tar pitch was isotropic; however, upon using increased SGR pyrolysis conditions, the resulting coal tar pitch samples substantially increased in the percentage and quality of anisotropy formation. Further, the products' analyses show clear trends of modified chemical properties in the intermediate coal tar and improved anisotropy results. Thus, the results presented in this work show that by controlling the SGR during pyrolysis of a non-coking coal, this approach can modify the coal tar chemistry towards a precursor more suitable for quality anisotropic carbon material production.

01 COAL, LIGNITE, AND PEAT↗

Two-step route to size and shape controlled gibbsite nanoplates and the crystal growth mechanism

Mastery of gibbsite (α-Al(OH) 3 ) nucleation and crystal growth is significant in fundamental aluminum chemistry and also beneficial for industrial applications and the remediation of nuclear waste. Herein, we developed an additive-free two-step route to size and morphology controlled synthesis of gibbsite nanoplates. Independent temperature manipulation of nucleation and crystal growth regimes was used to control the efficacy and yield of the process, producing gibbsite nanoplates with tunable morphologies and sizes. We achieve morphologies ranging from hexagon, pseudo hexagon, truncated triangle to rhombic, and average basal plane diameters from 120 to 850 nm, with thicknesses between 8 and 45 nm. Analysis of gibbsite structure, size and morphology with techniques including powder X-ray diffraction (p-XRD), 27 Al magic angle spinning nuclear magnetic resonance spectroscopy (MAS NMR), scanning electron microscopy (SEM), and atomic force microscopy (AFM) provided key details on the nucleation and crystal growth mechanisms. The results indicate the temperature of the nucleation aging step is the most important factor controlling the final particle size. Particularly small nanoplates were obtained with a low nucleation aging temperature followed by high crystal growth temperature, suggesting that gibbsite growth can be approximated via a LaMer-type burst nucleation and crystal growth mechanism. Scalability was demonstrated by triplicate of 2 L experiments which prepared gibbsite nanoplates of ~200 nm size and with an average yield of ~55% after 84 h. Compared to existing techniques, this improved two-step route is cheaper, more efficient and environmentally friendly.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nano-compositional imaging of the lanthanum silicide system at THz wavelengths

Terahertz scattering-type scanning near-field optical microscopy (THz-sSNOM) provides a noninvasive way to probe the low frequency conductivity of materials and to characterize material compositions at the nanoscale. However, the potential capability of atomic compositional analysis with THz nanoscopy remains largely unexplored. Here, we perform THz near-field imaging and spectroscopy on a model rare-earth alloy of lanthanum silicide (La–Si) which is known to exhibit diverse compositional and structural phases. We identify subwavelength spatial variations in conductivity that is manifested as alloy microstructures down to much less than 1 μ m in size and is remarkably distinct from the surface topography of the material. Signal contrasts from the near-field scattering responses enable mapping the local silicon/lanthanum content differences. These observations demonstrate that THz-sSNOM offers a new avenue to investigate the compositional heterogeneity of material phases and their related nanoscale electrical as well as optical properties.

47 OTHER INSTRUMENTATION↗

A Comparative Study of Thermal Oxidization Resistance of a High-Entropy Metal Boride and a High-Entropy Metal Carbide

We present a systematic study of thermal oxidation resistance of transition metal borides and carbides up to 1300 °C in a dry air environment. A High-Entropy Metal Boride (HEMB), of composition (Hf 0.2 , Mo 0.2 , Nb 0.2 , Ta 0.2 , Zr 0.2 )B 2 , and a similar High-Entropy Metal Carbide (HEMC) (Hf, Mo, Nb, Ta, Zr)C 5 were synthesized from precursor mixtures, under 30 MPa of pressure at a temperature of 1800 °C using a Spark Plasma Sintering Device. The synthesized phases were confirmed via X-ray Diffraction analysis, which showed a pure hexagonal AlB 2 -type structure for HEMB and a face-centered cubic (FCC) structure for HEMC, with lattice parameters, a = 3.10 Å and c = 3.37 Å for HEMB and a = 4.524 Å for HEMC. Oxidation resistance was evaluated using a simultaneous thermogravimetric analysis and differential scanning calorimetry (TGA/DSC) stage in which HEMB and HEMC were heated up to 1300 °C at a rate of 2 °C/min in a dry air environment. Scanning electron microscopy (SEM) was used to analyze the resulting oxidized material. Our study demonstrates that HEMB shows better thermal oxidation resistance as compared to a similar metal composition HEMC at high temperatures.

36 MATERIALS SCIENCE↗

Study of Helium Irradiation Effect on Al6061 Alloy Fabricated by Additive Friction Stir Deposition

Additive friction stir deposition (AFS-D) is considered a productive method of additive manufacturing (AM) due to its ability to produce dense mechanical parts at a faster deposition rate compared to other AM methods. Al6061 alloy finds extensive application in aerospace and nuclear engineering; nevertheless, exposure to radiation or high-energy particles over time tends to deteriorate their mechanical performance. However, the effect of radiation on the components manufactured using the AFS-D method is still unexamined. In this work, samples from the as-fabricated Al6061 alloy, by AFS-D, and the Al6061 feedstock rod were irradiated with He+ ions to 10 dpa at ambient temperature. The microstructural and mechanical changes induced by irradiation of He+ were examined using a scanning electron microscope (SEM), energy-dispersive X-ray spectroscopy (EDS), transmission electron microscopy (TEM), and nanoindentation. This study demonstrates that, at 10 dpa of irradiation damage, the feedstock Al6061 produced a bigger size of He bubbles than the AFS-D Al6061. Nanoindentation analysis revealed that both the feedstock Al6061 and AFS-D Al6061 samples have experienced radiation-induced hardening. These studies provide a valuable understanding of the microstructural and mechanical performance of AFS-D materials in radiation environments, offering essential data for the selection of materials and processing methods for potential application in aerospace and nuclear engineering.

36 MATERIALS SCIENCE↗

Size-Resolved Chemical Composition of Particles Collected Using STAC at the Ground Site During the SAIL Campaign in Gunnison, Colorado

Aerosol particles were collected using a four-stage Size and Time-resolved Aerosol Collector (STAC) during the SAIL field campaign. Each stage of STAC separates particles into distinct aerodynamic size fractions with 50% cut-off diameters: Stage A: 2.27 µm Stage B: 0.615 µm Stage C: 0.421 µm Stage D: 0.119 µm Each stage provides both size- and time-resolved sampling, enabling investigation of particle composition across different atmospheric regimes. Only a subset of samples was selected for analysis based on prevailing meteorological conditions (e.g., temperature, humidity, and air-mass influence) to capture representative aerosol types under distinct weather patterns. Collected substrates were first examined under Scanning Electron Microscopy (SEM) to evaluate particle loading, morphology, and spatial distribution. Subsequently, Computer-Controlled Scanning Electron Microscopy with Energy-Dispersive X-ray Spectroscopy (CCSEM/EDX) was performed to obtain size-resolved elemental composition of individual particles. A rule-based classification scheme was applied to categorize particles into major compositional groups (e.g., biological, carbonaceous, dust, sulfate, Na-rich, and mixed types). This dataset provides high-resolution morphological and chemical information on atmospheric particles collected during the SAIL campaign, offering insights into the influence of meteorology on aerosol composition and mixing state.

Size and Time-resolved Aerosol Collector↗

Three-dimensional visualization and display technologies; Proceedings of the Meeting, Los Angeles, CA, Jan. 18-20, 1989

Special attention was given to problems of stereoscopic display devices, such as CAD for enhancement of the design process in visual arts, stereo-TV improvement of remote manipulator performance, a voice-controlled stereographic video camera system, and head-mounted displays and their low-cost design alternatives. Also discussed was a novel approach to chromostereoscopic microscopy, computer-generated barrier-strip autostereography and lenticular stereograms, and parallax barrier three-dimensional TV. Additional topics include processing and user interface isssues and visualization applications, including automated analysis and fliud flow topology, optical tomographic measusrements of mixing fluids, visualization of complex data, visualization environments, and visualization management systems.

Robbins, Woodrow E.↗

Spacecraft thermal control coatings

The Experiment AO 138-6 was located on the trailing edge of the Long Duration Exposure Facility as part of the French Cooperative Payload (FRECOPA) Experiment. It was purely passive in nature: material specimens 2 x 2 cm, independently mounted in sample-holders, with their surface in the same reference plane, were exposed to space. Thirty samples were set in a vacuum-tight canister which was opened in space a few days after LDEF deployment and closed while still in orbit ten months later; twenty-four samples were directly exposed to space for the total flight duration (preflight handling, shuttle bay environment, separation from shuttle, shuttle environment, LEO environment, docking, descent, transfer to KSC). Materials included paints (conductive or nonconductive), SSM's, polymeric films, surface coatings, composite materials, and metals. After sample retrieving, inspection and measurements were carried out in atmospheric laboratory conditions on each sample: observation with binocular lenses and scanning electron microscopy, spectral relectance and transmittance using an integrating sphere in the wavelength range 280-2300 nm, emissivity by the means of a Gier & Dunkle portable reflectometer, electron spectroscopy for chemical analysis-x-ray photoelectron spectroscopy (ESCA-XPS), and Rutherford backscattering spectroscopy (RBS) measurements on some selected samples. The results obtained from flight were compared to laboratory data obtained in UV-irradiation tests when these data were available. As a general statement a good spectral concordance is observed for all samples not in the canister so long as air recoveries are taken into account. For one material, the degradation is more important for the sample in the canister than for those of the same material mounted at the surface of the tray; for most samples in the canister the degradation is slightly higher than the one which can be predicted from laboratory standard irradiations. Contamination problems having been ruled out, the higher temperature experience by the samples on the inside of canister probably explains these phenomena.

Guillaumon, Jean-Claude↗