Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Load‐balanced and locality‐aware scheduling for data‐intensive workloads at extreme scales

Summary Data‐driven programming models such as many‐task computing (MTC) have been prevalent for running data‐intensive scientific applications. MTC applies over‐decomposition to enable distributed scheduling. To achieve extreme scalability, MTC proposes a fully distributed task scheduling architecture that employs as many schedulers as the compute nodes to make scheduling decisions. Achieving distributed load balancing and best exploiting data locality are two important goals for the best performance of distributed scheduling of data‐intensive applications. Our previous research proposed a data‐aware work‐stealing technique to optimize both load balancing and data locality by using both dedicated and shared task ready queues in each scheduler. Tasks were organized in queues based on the input data size and location. Distributed key‐value store was applied to manage task metadata. We implemented the technique in MATRIX, a distributed MTC task execution framework. In this work, we devise an analytical suboptimal upper bound of the proposed technique, compare MATRIX with other scheduling systems, and explore the scalability of the technique at extreme scales. Results show that the technique is not only scalable but can achieve performance within 15% of the suboptimal solution. Copyright © 2015 John Wiley & Sons, Ltd.

Wang, Ke↗

Volcano‐like Activity Trends in Au@Pd Catalysts: The Role of Pd Loading and Nanoparticle Size

The addition of palladium (Pd) to preformed gold nanoparticles (Au NPs) enables the formation of core‐shell structures with enhanced catalytic performance in oxidation reactions. However, predicting the precise palladium content required to achieve maximum catalytic activity remains difficult based on current understanding. Herein, Pd was systematically introduced onto titania‐supported Au NPs (2, 6, and 10 nm) to evaluate their performance in benzyl alcohol oxidation. A volcano‐like trend in catalytic activity was observed, where activity increased with Pd addition, peaked, and then declined. The Pd loading required for maximum activity depended on Au NP size: ≈40 at% Pd/Au for 2.6 nm, ≈20 at% Pd/Au for 6.4 nm, and ≈12.5 at% Pd/Au for 10.6 nm. For Au NPs > 6 nm, peak activity aligned with monolayer Pd coverage, while for smaller NPs (2–3 nm), optimal Pd content was below monolayer predictions. X‐ray absorption spectroscopy revealed a core‐shell structure at low Pd content, but higher Pd loadings led to Pd diffusion into the Au core. This structural transformation likely caused activity decline, indicating that AuPd alloying negatively impacts catalysis. These results highlight that core‐shell Au@Pd catalysts outperform AuPd alloys and provide crucial insights for designing highly active bimetallic catalysts.

X-ray absorption spectroscopy↗

Biocatalytic Carboxylic Acid Reduction and Transamination in Cell‐Free Lysates at High Substrate Loading

Chemoselective reduction of stable carboxylic acids to reactive aldehydes is of interest across many industries. While carboxylic acid reductases (CARs) are promising biocatalysts for this chemistry, poor chemoselectivity and low yield are commonly obtained when using less expensive crude lysate preparations and prerequisite ATP and NADPH regeneration systems. Here, in this work, we developed a highly chemoselective multienzyme cascade featuring a CAR and an ω-transaminase (TA) in crude lysate format, with conversion of the dicarboxylic acid terephthalic acid (TPA) into the diamine para -xylylenediamine (pXDA) as the model chemistry. We improved chemoselectivity for pXDA using engineered aldehyde-stabilizing Escherichia coli strains, though desired product yields remained modest. We next found that CAR activity was limited at high substrate loadings and overcame this bottleneck by modulating the ratio of polyphosphate (polyP 6 ) to Mg 2+ , enabling volumetric scaling and increased substrate loading up to 50 mM TPA. We then showcased the portability of this platform across substrates, resulting in the synthesis of four other high-value amines from carboxylate precursors. The combination of high carboxyl group turnover, up to 93.5 mM under the tested conditions, and the simplicity of crude enzyme preparation is a promising platform for sustainable functional group interconversion.

60 APPLIED LIFE SCIENCES↗

Tungsten-loaded SMP foam nanocomposites with inherent radiopacity and tunable thermo-mechanical properties

Shape memory polymer (SMP) foams have been developed for use in neurovascular occlusion applications. These materials are predominantly polyurethanes that are known for their biocompatibility and tunable properties. However, these polymers inherently lack X–ray visibility, which is a significant challenge for their use as implantable materials. Herein, low density, highly porous shape memory polyurethane foams were developed with tungsten nanoparticles dispersed into the foam matrix, at increasing concentrations, to serve as a radiopaque agent. Utilizing X–ray fluoroscopy sufficient visibility of the foams at small geometries was observed. Thermal characterization of the foams indicated altered thermal response and delayed foam actuation with increasing nanoparticle loading (because of restricted network mobility). Mechanical testing indicated decreased toughness and strength for higher loading because of disruption of the SMP matrix. Altogether, filler addition imparted x–ray visibility to the SMP foams and allowed for tuned control of the transition temperature and actuation kinetics for the material.

36 MATERIALS SCIENCE↗

Cationic cure kinetics of a polyoxometalate loaded epoxy nanocomposite

The reaction cure kinetics of a novel polyoxometalate (POM) loaded epoxy nanocomposite is described. The POM is dispersed in the epoxy resin up to volume fractions of 0.1. Differential scanning calorimetry measurements show the cure of the epoxy resin to be sensitive to the POM loading. A kinetics study of the cure exotherm confirms that POM acts as a catalyst promoting cationic homopolymerization of the epoxy resin. The cure reaction is shown to propagate through two cure regimes. A fast cure at short time is shown to be propagation by the activated chain end (ACE) mechanism. A slow cure at long time is shown to be propagation by the activated monomer (AM) mechanism. The activation energies for the fast and slow cure regimes agree well with other epoxy based systems that have been confirmed to propagate by the ACE and AM mechanisms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isotopic analysis of sub-nanogram neodymium loads using new ATONA™ amplifiers

The long-term gains of the ATONA™ amplifiers are shown to have less than 1 ppm variability. Repeat measurements of the JNdi-1 reference material demonstrate the ability of the ATONA™ amplification technology to make measurements of 143 Nd/ 144 Nd ratios with 23 ppm external reproducibility on 100-pg loads. The effect of increasing integration time on analytical reproducibility is also displayed as increasing integration time from 10 to 30s reduced the external measurement uncertainty from 37 to 23 ppm. These measurements represent an improvement of more than a factor of 3 in external measurement reproducibility relative to previously published 143 Nd/ 144 Nd measurements of 100-pg loads. Furthermore, this new technology will allow for the measurement of smaller samples for precise isotope ratios and open new avenues of research in the geological and nuclear forensic communities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Underlying Substrate Effect on Electrochemical Activity for Hydrogen Evolution Reaction with Low‐Platinum‐Loaded Catalysts

Platinum is known as the best catalyst for the hydrogen evolution reaction (HER) but the scarcity and high cost of Pt limit its widespread applicability. Herein, the role of the underlying substrate on the HER activity of dispersed Pt atoms is uncovered. A direct current magnetron sputtering technique is utilized to deposit transition metal (TM) thin films of W, Ti, and Ta as underlying substrates for extremely low loading of Pt (<1.5 at%). The electrocatalytic performance of as‐synthesized samples for the HER is examined in both alkali and acidic media. The results show that despite the low loading of Pt, the Pt/TM catalysts produce hydrogen at a rate comparable to that of pristine bulk Pt. Pt/TM catalysts also display good stability with less than 5% decay in performance after 10 h of continuous HER operation. Based on the computational study, the excellent performance is attributed to the modified electronic properties of the Pt atoms, offering ideal binding energy for HER due to interaction with the underlying substrates. This work provides a robust and industry‐friendly route toward designing efficient catalytic systems for important electrochemical reactions such as HER and others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization and Modeling of Polymeric Foam Under Multi-Axial Static and Dynamic Loading

A polymeric foam commonly used in composite sandwich structures was characterized under multi-axial loading at strain rates varying from quasi-static to dynamic. Additionally, tests were conducted under uniaxial compression, tension, pure shear and combinations of normal and shear stresses. Quasi-static and intermediate strain rate tests were conducted in a servo-hydraulic testing machine. High strain rate tests were conducted using a split Hopkinson pressure bar (Kolsky bar) system made of polycarbonate bars having an impedance compatible to that of the foam material. The typical compressive stress-strain behavior of the polymeric foam exhibits a linear elastic region up to a yield point, a nonlinear elastic-plastic region up to an initial peak or “critical stress” corresponding to collapse initiation of the cells, followed by strain softening up to a local minimum (plateau or saddle point stress) and finally, a strain hardening region up to densification of the foam. The characteristic stresses of the stress-strain behavior vary linearly with the logarithm of strain rate. A general three-dimensional elastic-viscoplastic model, formulated in strain space, was proposed. The model expresses the multi-axial state of stress in terms of an effective stress, incorporates strain rate effects and includes the large deformation region. Stress-strain curves obtained under multi-axial loading at different strain rates were used to develop and validate the elastic-viscoplastic constitutive model. Lastly, excellent agreement was shown between model predictions and experimental results.

36 MATERIALS SCIENCE↗

Transcatheter Treatment of Hepatocellular Carcinoma with Doxorubicin-loaded DC Bead (DEBDOX): Technical Recommendations

Tranarterial chemoembolization (TACE) has been established by a meta-analysis of randomized controlled trials as the standard of care for nonsurgical patients with large or multinodular noninvasive hepatocellular carcinoma (HCC) isolated to the liver and with preserved liver function. Although conventional TACE with administration of an anticancer-in-oil emulsion followed by embolic agents has been the most popular technique, the introduction of embolic drug-eluting beads has provided an alternative to lipiodol-based regimens. Experimental studies have shown that TACE with drug-eluting beads has a safe pharmacokinetic profile and results in effective tumor killing in animal models. Early clinical experiences have confirmed that drug-eluting beads provide a combined ischemic and cytotoxic effect locally with low systemic toxic exposure. Recently, the clinical value of a TACE protocol performed by using the embolic microsphere DC Bead loaded with doxorubicin (DEBDOX; drug-eluting bead doxorubicin) has been shown by randomized controlled trials. An important limitation of conventional TACE has been the inconsistency in the technique and the treatment schedules. This limitation has hampered the acceptance of TACE as a standard oncology treatment. Doxorubicin-loaded DC Bead provides levels of consistency and repeatability not available with conventional TACE and offers the opportunity to implement a standardized approach to HCC treatment. With this in mind, a panel of physicians took part in a consensus meeting held during the European Conference on Interventional Oncology in Florence, Italy, to develop a set of technical recommendations for the use of DEBDOX in HCC treatment. The conclusions of the expert panel are summarized.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon-Occluded Transcatheter Arterial Chemoembolization (b-TACE) for Hepatocellular Carcinoma Performed with Polyethylene-Glycol Epirubicin-Loaded Drug-Eluting Embolics: Safety and Preliminary Results

Purpose: To report technical success, safety profile and oncological results of balloon-occluded transcatheter arterial chemoembolization using a balloon micro-catheter and epirubicin-loaded polyethylene-glycol (PEG) microsphere (100 ± 25 µm and 200 ± 50 µm) in patients with hepatocellular carcinoma (HCC). Materials and Methods: This is a single-centre, single-arm, retrospective study with 6-month follow-up. Twenty-two patients (Child–Pugh A 68% [15/22], B in 32% [7/22]; age 67.05 ± 14 years) with 29 HCC were treated in 24 procedures. Technical success is defined: ability to place the balloon micro-catheter within the required vascular segment, balloon-occluded arterial stump pressure drops and assessment of microsphere deposition. Laboratory assessment pre/post-procedural and complications were analysed, respectively, according to Common Terminology Criteria for Adverse Events (CTCAEv5) and CIRSE system. Postembolization syndrome (PES) was defined as fever and/or nausea and/or pain onset. Oncological results were evaluated using m-RECIST criteria with CT/MRI imaging at 1 and 3–6 months. In partial responder patients, pre/post-procedural tumour volume was compared. Results: Pre-planned feeder was reached in all cases. Pressure drop average was 51.1 ± 21.6 mmHg. Exclusive target embolization was achieved in 14/24 procedures (58.3%). Laboratory test modifications were all grade 1. 4/24 adverse events occurred (17%): pseudo-aneurysm of the feeder (grade 3), liver abscess (grade 2) and 2 asymptomatic segmentary biliary tree dilatations (grade 2). PES occurred in 8/24 (33%). The complete response at 1 and 3–6 months was 44.8% (13/29) and 52.9% (9/17), respectively. The partial response at 1 and 3–6 months was 55% (16/29) and 4/17 (23.5%), respectively. Among partial responder patients, the average percentage of tumour volume reduction was 64.9 ± 27.3%. Conclusion: Epirubicin-loaded PEG microsphere b-TACE is technically feasible, safe and effective procedure for HCC treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interpreting test temperature and loading rate effects on the fracture toughness of polymer-metal interfaces via time–temperature superposition

Here, in this letter, we present interfacial fracture toughness data for a polymer-metal interface where tests were conducted at various test temperatures T and loading rates $\dot{δ}$. An adhesively bonded asymmetric double cantilever beam (ADCB) specimen was utilized to measure toughness. ADCB specimens were created by bonding a thinner, upper adherend to a thicker, lower adherend (both 6061 T6 aluminum) using a thin layer of epoxy adhesive, such that the crack propagated along the interface between the thinner adherend and the epoxy layer. The specimens were tested at T from 25 to 65 °C and $\dot{δ}$ from 0.002 to 0.2 mm/s. The measured interfacial toughness Γ increased as both T and $\dot{δ}$ increased. For an ADCB specimen loaded at a constant $\dot{δ}$, the energy release rate G increases as the crack length a increases. For this reason, we defined rate effects in terms of the rate of change in the energy release rate $\dot{G}$. Although not rigorously correct, a formal application of time–temperature superposition (TTS) analysis to the Γ data provided useful insights on the observed dependencies. In the TTS-shifted data, Γ decreased and then increased for monotonically increasing $\dot{G}$. Thus, the TTS analysis suggests that there is a minimum value of Γ. This minimum value could be used to define a lower bound in Γ when designing critical engineering applications that are subjected to T and $\dot{δ}$ excursions.

36 MATERIALS SCIENCE↗

Effects of Weathering on Mechanical, Antimicrobial Properties and Biodegradation Process of Silver Loaded TPE Compounds

The incorporation of antimicrobial metals such as silver is an alternative to protect the material against microbial attack. However, loaded polymer can lose its antimicrobial properties after some time of use, and the additive may even leak out into the environment becoming harmful to non-target organisms. This study aims to evaluate the mechanical properties and antimicrobial activity of silver containing thermoplastic elastomer (TPE) samples exposed to weathering and the influence of additive incorporation in material biodegradation in the soil. For this purpose, silver ions (Ag{sup +}-bentonite, Ag{sup +}-phosphate) and silver nanoparticles (AgNp-silica) based additives were blended in a formulation of SEBS, polypropylene and mineral oil. The test samples were exposed to natural ageing over nine months, and were then evaluated according to their mechanical properties, antimicrobial activity, and degree of crystallinity and surface characteristics. The biodegradation process before and after natural ageing was evaluated through the generation of carbon dioxide. The results show that the action of natural ageing reduced the mechanical properties of loaded and unloaded TPE, and modified the degree of crystallinity and the chemical characteristic of the TPE surface. The presence or type of additive did not influence material resistance after being exposed to weathering. A decrease in antimicrobial activity in samples after natural ageing was observed. At a variable level and according to the chemical content, generation of carbon dioxide from TPE samples was greater in aged samples than in unexposed ones.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of particle characteristics on the evolution of particle size, particle morphology, and fabric of sands loaded under uniaxial compression

This work presents the results and analyses of uniaxial compression experiments performed on three silica sands. The sands have comparable particle-size distributions, but their particles differ in morphology and strength. Cylindrical samples of the three sands were compressed in a loading device placed inside an X-ray microscope (XRM) and scanned at multiple stress levels during uniaxial compression. 3D tomography data of the samples obtained from the XRM at different stress levels were then analyzed to obtain the distributions of particle size, particle morphology, and interparticle contact normals within the sample. Results indicate that: (1) the compressibility of the sands loaded under uniaxial compression is closely tied to particle morphology and strength and (2) the anisotropy in the orientations of interparticle contact normals generally increases with axial stress; however, this increase is limited by the occurrence of particle crushing in the sample.

3D X-ray computed tomography↗

First in-situ lattice strains measurements under load at VULCAN

The engineering materials diffractometer, VULCAN, at the Spallation Neutron Source began commissioning on June 26, 2009. This instrument is designed for materials science and engineering studies. In situ lattice strain measurements of a model metallic material under monotonic tensile load have been performed on VULCAN. The tensile load was applied under two different strain rates, and neutron diffraction measurements were carried out in both high-intensity and high-resolution modes. These experiments demonstrated VULCAN's in situ study capability of deformation behaviors even during the early phases of commissioning.

43 PARTICLE ACCELERATORS↗

The Effects of Specimen Geometry on the Plastic Deformation of AA 2219-T8 Aluminum Alloy Under Dynamic Impact Loading

The effects of specimen geometry on shear strain localization in AA 2219-T8 aluminum alloy under dynamic impact loading were investigated. The alloy was machined into cylindrical, cuboidal and conical (frustum) test specimens. Both deformed and transformed adiabatic shear bands developed in the alloy during the impact loading. The critical strain rate for formation of the deformed band was determined to be 2500 s{sup −1} irrespective of the specimen geometry. The critical strain rate required for formation of transformed band is higher than 3000 s{sup −1} depending on the specimen geometry. The critical strain rate for formation of transformed bands is lowest (3000 s{sup −1}) in the Ø5 mm × 5 mm cylindrical specimens and highest (> 6000 s{sup −1}) in the conical specimens. The cylindrical specimens showed the greatest tendency to form transformed bands, whereas the conical specimen showed the least tendency. The shape of the shear bands on the impacted plane was also observed to be dependent on the specimen geometry. Whereas the shear bands on the compression plane of the conical specimens formed elongated cycles, two elliptical shaped shear bands facing each other were observed on the cylindrical specimens. Two parallel shear bands were observed on the compression planes of the cuboidal specimens. The dynamic stress–strain curves vary slightly with the specimen geometry. The cuboidal specimens exhibit higher tendency for strain hardening and higher maximum flow stress than the other specimens. The microstructure evolution leading to the formation of transformed bands is also discussed in this paper.

36 MATERIALS SCIENCE↗

Controlled High Filler Loading of Functionalized Al{sub 2}O{sub 3}-Filled Epoxy Composites for LED Thermal Management

Thermal management in light-emitting diode (LED) has been extensively researched recently. This study is intended to develop an effective thermally conductive epoxy composite as thermal interface material (TIM) for headlamp LEDs. Silane-functionalized aluminum oxide (Al{sub 2}O{sub 3}) powder of different average particle sizes (44 and 10 µm) was studied for its feasibility as filler at its maximum loading. A detailed comparison of three different methods of particle dispersions, hand-mix, speed-mix and calendaring process (3-roll mill), has been reported. The dispersion of Al{sub 2}O{sub 3} particles, the thermal conductivity and thermal degradation characteristics of the composites were investigated and explained in detail. At 75 wt.% filler loading, 10 and 44 µm Al{sub 2}O{sub 3} achieved composite thermal conductivities of 1.13 and 2.08 W/mK, respectively, which is approximately 528 and 1055% of enhancement with respect to neat epoxy. The package-level thermal performance of the LED employing the Al{sub 2}O{sub 3}-filled TIMs was carried out using thermal transient analysis. The experimental junction-to-ambient thermal resistances (R{sub thJ-A}) achieved were 6.65, 7.24, and 8.63 K/W for Al{sub 2}O{sub 3-44µm}, Al{sub 2}O{sub 3-10µm} and neat epoxy, respectively. The results revealed that the Al{sub 2}O{sub 3-44µm} fillers-filled composite performed better in both material-level and package-level thermal characteristics.

36 MATERIALS SCIENCE↗

Multiaxial creep–fatigue Life Prediction Under Variable Amplitude Loading at High Temperature

Based on the time–temperature parameter method, a modified von Mises stress is proposed to calculate the multiaxial creep damage at high temperature. By employing the strain-based multiaxial fatigue damage models, the modified von Mises stress is used to predict the creep–fatigue life under variable amplitude multiaxial loading at high temperature. The experimental data of GH4169 superalloy and 304 stainless steel conducted under both constant and variable amplitude loadings at high temperature are used to verify the proposed method, and a good agreement is obtained with the experimental data.

42 ENGINEERING↗

Intergranular Strain Evolution During Biaxial Loading: A Multiscale FE-FFT Approach

Predicting the macroscopic and microscopic mechanical response of metals and alloys subjected to complex loading conditions necessarily requires a synergistic combination of multiscale material models and characterization techniques. This article focuses on the use of a multiscale approach to study the difference between intergranular lattice strain evolution for various grain families measured during in situ neutron diffraction on dog bone and cruciform 316L samples. At the macroscale, finite element simulations capture the complex coupling between applied forces and gauge stresses in cruciform geometries. The predicted gauge stresses are used as macroscopic boundary conditions to drive a mesoscale full-field elasto-viscoplastic fast Fourier transform crystal plasticity model. The results highlight the role of grain neighborhood on the intergranular strain evolution under uniaxial and equibiaxial loading.

36 MATERIALS SCIENCE↗