Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “large”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Accelerating Large-Format Metal Additive Manufacturing: How Controls R&D is Driving Speed, Scale, and Efficiency

This article highlights work at Oak Ridge National Laboratory’s Manufacturing Demonstration Facility to develop closed-loop, feedback control for laser-wire based Directed Energy Deposition, a form of metal Big Area Additive Manufacturing (m-BAAM), a process being developed in partnership with GKN Aerospace specifically for the production of Ti-6Al-4V pre-forms for aerospace components. A large-scale structural demonstrator component is presented as a case-study in which not just control, but the entire 3D printing workflow for m-BAAM is discussed in detail, including design principles for large-format metal AM, toolpath generation, parameter development, process control, and system operation, as well as post-print net-shape geometric analysis and finish machining. In terms of control, a multi-sensor approach has been utilized to measure both layer height and melt pool size, and multiple modes of closed-loop control have been developed to manipulate process parameters (laser power, print speed, deposition rate) to control these variables. Layer height control and melt pool size control have yielded excellent local (intralayer) and global (component-level) geometry control, and the impact of melt pool size control in particular on thermal gradients and material properties is the subject of continuing research. Further, these modes of control have allowed the process to advance to higher deposition rates (exceeding 7.5 lb/hr), larger parts (1-meter scale), shorter build times, and higher overall efficiency. The control modes are examined individually, highlighting their development, demonstration, and lessons learned, and it is shown how they operate concurrently to enable the printing of a large-scale, near net shape Ti-6Al-4V component.

Gibson, Brian↗

Experimental Results for Large Particle Separation from Non-Newtonian Slurries Using Tapered Bump Arrays

Lateral displacement arrays are useful for separating particles such as blood cells and sand from carrier fluids. These arrays consist of staggered posts, which allow smaller particles to follow streamlines and larger particles to flow around the posts and migrate to one side. This migration increases the particle concentration in one direction and depletes the particle concentration in the other direction allowing particle separation to occur. Experiments were conducted to separate large particles in non-Newtonian yield stress slurries using tapered bump arrays. The non-Newtonian slurry used was composed of a bentonite kaolin blend with the inclusion of larger diameter particles. These experiments were conducted to evaluate the performance of particle separation using a tapered array of staggered posts as configured in a bump array for non-Newtonian yield stress slurries, an application that has not been explored experimentally. A theory for large particle separation was developed for slurries that exhibit Bingham or Cross rheology. The results of these experiments are described. This information could be applied in industrial settings such as separation of particles from nuclear waste slurries including those to be processed at the Hanford site, where removing large particles from waste streams is important to processing.

slurry, solids removal, deterministic lateral disp↗

Comparing Experimental Results for Large Particle Separation from Non-Newtonian Slurries Using Full and Tapered Bump Arrays

To separate particles from carrier fluids arrays of staggered posts inserted into the flow stream can be employed. The smaller particles follow the flow stream while the larger particles move laterally to one side. During flow, the concentration of particulate increases in one direction and decreases in the other crosswise direction. This technique separates the particles from the carrier fluid. Experiments using a slurry with non-Newtonian rheology were conducted to evaluate large particle separation from the non-Newtonian carrier fluid using bump arrays. The bentonite kaolin clay slurry with non-Newtonian rheology was spiked with large diameter inert glass particles. Experiments with flow through lateral displacement arrays evaluated the performance of particle separation using two array configurations: a full array with all posts and a tapered array with posts removed in a triangular portion of the array past the rows of anticipated particle of separation. The posts are staggered posts to promote particle segregation to one side of the flow channel. Using this type of array for removing particles from non-Newtonian yield stress slurries is novel and we present unique results. In this paper, the performance of full and tapered arrays are compared. These results have many industrial applications including removing particles from slurries of nuclear waste. Large particle removal is an important step in waste processing.

slurry, solids removal, deterministic lateral disp↗

Developing Magnetorheological Finishing (MRF) Technology for the Manufacture of Large-Aperture Optics in Megajoule Class Laser Systems

Over the last eight years we have been developing advanced MRF tools and techniques to manufacture meter-scale optics for use in Megajoule class laser systems. These systems call for optics having unique characteristics that can complicate their fabrication using conventional polishing methods. First, exposure to the high-power nanosecond and sub-nanosecond pulsed laser environment in the infrared (>27 J/cm{sup 2} at 1053 nm), visible (>18 J/cm{sup 2} at 527 nm), and ultraviolet (>10 J/cm{sup 2} at 351 nm) demands ultra-precise control of optical figure and finish to avoid intensity modulation and scatter that can result in damage to the optics chain or system hardware. Second, the optics must be super-polished and virtually free of surface and subsurface flaws that can limit optic lifetime through laser-induced damage initiation and growth at the flaw sites, particularly at 351 nm. Lastly, ultra-precise optics for beam conditioning are required to control laser beam quality. These optics contain customized surface topographical structures that cannot be made using traditional fabrication processes. In this review, we will present the development and implementation of large-aperture MRF tools and techniques specifically designed to meet the demanding optical performance challenges required in large-aperture high-power laser systems. In particular, we will discuss the advances made by using MRF technology to expose and remove surface and subsurface flaws in optics during final polishing to yield optics with improve laser damage resistance, the novel application of MRF deterministic polishing to imprint complex topographical information and wavefront correction patterns onto optical surfaces, and our efforts to advance the technology to manufacture large-aperture damage resistant optics.

42 ENGINEERING↗

Comparison of fractionation schedules in the large heterogeneity limit

The author develops an analytical formula that relates total doses in different fractionation schemes using the linear-quadratic (LQ) model in the limit when the interpatient variation in radiosensitivity is large. We use published formulas for tumor control probability and parameter dependence developed for the large heterogeneity limit. We consider the isoeffect equation and uses simple algebraic manipulation to obtain the new fractionation formula valid for the large heterogeneity limit. We study the case of going from a dose per fraction of 1.8 Gy to a dose per fraction of 3 Gy, which is relevant for current hypofractionation schemes for prostate and breast cancer. We find that the total dose for the new fractionation depends not only on the {alpha}/{beta} ratio r but also on the ratio of the corresponding standard deviations {sigma}{sub {alpha}}/{sigma}{sub {beta}} and on the ratio between the original dose D{sub 1} and D{sub 50}. In some special cases, notably when D{sub 1}=D{sub 50(1)}, the standard LQ model is recovered. In general, when the relative widths of the distributions for {alpha} and {beta} are equal or similar, the deviation from the standard LQ model is small, mostly within 5% for D{sub 1}/D{sub 50(1)} from 0.4 up to 1.6. When the width of the distribution for {alpha} is much larger than the one for {beta}, larger deviations from the standard LQ model are found for small values of r but they fall within 10% for r larger than 4 Gy and within 5% for r larger than 10 Gy. The most unforgiving case is when the width of the distribution for {alpha} is much smaller than the one for {beta}, where the largest differences with the standard LQ model are found. While, in general, the formula can give a significantly different result than the standard LQ model equation, we find a range of parameters for which the difference is surprisingly small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-480: Radiobiological Dose Comparison of Single Fraction SRS, Multi-Fraction SRT and Multi-Stage SRS of Large Target Volumes Using the Linear-Quadratic Formula

Purpose: To compare the radiobiological effect on large tumors and surrounding normal tissues from single fraction SRS, multi-fractionated SRT, and multi-staged SRS treatment. Methods: An anthropomorphic head phantom with a centrally located large volume target (18.2 cm{sup 3}) was scanned using a 16 slice large bore CT simulator. Scans were imported to the Multiplan treatment planning system where a total prescription dose of 20Gy was used for a single, three staged and three fractionated treatment. Cyber Knife treatment plans were inversely optimized for the target volume to achieve at least 95% coverage of the prescription dose. For the multistage plan, the target was segmented into three subtargets having similar volume and shape. Staged plans for individual subtargets were generated based on a planning technique where the beam MUs of the original plan on the total target volume are changed by weighting the MUs based on projected beam lengths within each subtarget. Dose matrices for each plan were export in DICOM format and used to calculate equivalent dose distributions in 2Gy fractions using an alpha beta ratio of 10 for the target and 3 for normal tissue. Results: Singe fraction SRS, multi-stage plan and multi-fractionated SRT plans had an average 2Gy dose equivalent to the target of 62.89Gy, 37.91Gy and 33.68Gy, respectively. The normal tissue within 12Gy physical dose region had an average 2Gy dose equivalent of 29.55Gy, 16.08Gy and 13.93Gy, respectively. Conclusion: The single fraction SRS plan had the largest predicted biological effect for the target and the surrounding normal tissue. The multi-stage treatment provided for a more potent biologically effect on target compared to the multi-fraction SRT treatments with less biological normal tissue than single-fraction SRS treatment.

60 APPLIED LIFE SCIENCES↗

Thermoacoustic imaging over large field of view for three-dimensional breast tumor localization: A phantom study

Purpose: Previous studies demonstrated that thermoacoustic imaging (TAI) has great potential for breast tumor detection. However, large field of view (FOV) imaging remains a long-standing challenge for three-dimensional (3D) breast tumor localization. Here, the authors propose a practical TAI system for noninvasive 3D localization of breast tumors with large FOV through the use of ultrashort microwave pulse (USMP). Methods: A USMP generator was employed for TAI. The energy density required for quality imaging and the corresponding microwave-to-acoustic conversion efficiency were compared with that of conventional TAI. The microwave energy distribution, imaging depth, resolution, and 3D imaging capabilities were then investigated. Finally, a breast phantom embedded with a laboratory-grown tumor was imaged to evaluate the FOV performance of the USMP TAI system, under a simulated clinical situation. Results: A radiation energy density equivalent to just 1.6%–2.2% of that for conventional submicrosecond microwave TAI was sufficient to obtain a thermoacoustic signal with the required signal-to-noise ratio. This result clearly demonstrated a significantly higher microwave-to-acoustic conversion efficiency of USMP TAI compared to that of conventional TAI. The USMP TAI system achieved 61 mm imaging depth and 12 × 12 cm{sup 2} microwave radiation area. The volumetric image of a copper target measured at depth of 4–6 cm matched well with the actual shape and the resolution reaches 230 μm. The TAI of the breast phantom was precisely localized to an accuracy of 0.1 cm over an 8 × 8 cm{sup 2} FOV. Conclusions: The experimental results demonstrated that the USMP TAI system offered significant potential for noninvasive clinical detection and 3D localization of deep breast tumors, with low microwave radiation dose and high spatial resolution over a sufficiently large FOV.

60 APPLIED LIFE SCIENCES↗

Large scale validation of the M5L lung CAD on heterogeneous CT datasets

Purpose: M5L, a fully automated computer-aided detection (CAD) system for the detection and segmentation of lung nodules in thoracic computed tomography (CT), is presented and validated on several image datasets. Methods: M5L is the combination of two independent subsystems, based on the Channeler Ant Model as a segmentation tool [lung channeler ant model (lungCAM)] and on the voxel-based neural approach. The lungCAM was upgraded with a scan equalization module and a new procedure to recover the nodules connected to other lung structures; its classification module, which makes use of a feed-forward neural network, is based of a small number of features (13), so as to minimize the risk of lacking generalization, which could be possible given the large difference between the size of the training and testing datasets, which contain 94 and 1019 CTs, respectively. The lungCAM (standalone) and M5L (combined) performance was extensively tested on 1043 CT scans from three independent datasets, including a detailed analysis of the full Lung Image Database Consortium/Image Database Resource Initiative database, which is not yet found in literature. Results: The lungCAM and M5L performance is consistent across the databases, with a sensitivity of about 70% and 80%, respectively, at eight false positive findings per scan, despite the variable annotation criteria and acquisition and reconstruction conditions. A reduced sensitivity is found for subtle nodules and ground glass opacities (GGO) structures. A comparison with other CAD systems is also presented. Conclusions: The M5L performance on a large and heterogeneous dataset is stable and satisfactory, although the development of a dedicated module for GGOs detection could further improve it, as well as an iterative optimization of the training procedure. The main aim of the present study was accomplished: M5L results do not deteriorate when increasing the dataset size, making it a candidate for supporting radiologists on large scale screenings and clinical programs.

60 APPLIED LIFE SCIENCES↗

Automatic detection of large pulmonary solid nodules in thoracic CT images

Purpose: Current computer-aided detection (CAD) systems for pulmonary nodules in computed tomography (CT) scans have a good performance for relatively small nodules, but often fail to detect the much rarer larger nodules, which are more likely to be cancerous. We present a novel CAD system specifically designed to detect solid nodules larger than 10 mm. Methods: The proposed detection pipeline is initiated by a three-dimensional lung segmentation algorithm optimized to include large nodules attached to the pleural wall via morphological processing. An additional preprocessing is used to mask out structures outside the pleural space to ensure that pleural and parenchymal nodules have a similar appearance. Next, nodule candidates are obtained via a multistage process of thresholding and morphological operations, to detect both larger and smaller candidates. After segmenting each candidate, a set of 24 features based on intensity, shape, blobness, and spatial context are computed. A radial basis support vector machine (SVM) classifier was used to classify nodule candidates, and performance was evaluated using ten-fold cross-validation on the full publicly available lung image database consortium database. Results: The proposed CAD system reaches a sensitivity of 98.3% (234/238) and 94.1% (224/238) large nodules at an average of 4.0 and 1.0 false positives/scan, respectively. Conclusions: The authors conclude that the proposed dedicated CAD system for large pulmonary nodules can identify the vast majority of highly suspicious lesions in thoracic CT scans with a small number of false positives.

60 APPLIED LIFE SCIENCES↗

SU-F-J-52: A Novel Approach to X-Ray Tube Quality Assurance for CBCT Systems in Order to Better Assess the Patient Imaging Dose in a Large, Multi-Unit Treatment Facility

Purpose: To standardize the tube calibration for Elekta XVI cone beam CT (CBCT) systems in order to provide a meaningful estimate of the daily imaging dose and reduce the variation between units in a large centre with multiple treatment units. Methods: Initial measurements of the output from the CBCT systems were made using a Farmer chamber and standard CTDI phantom. The correlation between the measured CTDI and the tube current was confirmed using an Unfors Xi detector which was then used to perform a tube current calibration on each unit. Results: Initial measurements showed measured tube current variations of up to 25% between units for scans with the same image settings. In order to reasonably estimate the imaging dose, a systematic approach to x-ray generator calibration was adopted to ensure that the imaging dose was consistent across all units at the centre and was adopted as part of the routine quality assurance program. Subsequent measurements show that the variation in measured dose across nine units is on the order of 5%. Conclusion: Increasingly, patients receiving radiation therapy have extended life expectancies and therefore the cumulative dose from daily imaging should not be ignored. In theory, an estimate of imaging dose can be made from the imaging parameters. However, measurements have shown that there are large differences in the x-ray generator calibration as installed at the clinic. Current protocols recommend routine checks of dose to ensure constancy. The present study suggests that in addition to constancy checks on a single machine, a tube current calibration should be performed on every unit to ensure agreement across multiple machines. This is crucial at a large centre with multiple units in order to provide physicians with a meaningful estimate of the daily imaging dose.

60 APPLIED LIFE SCIENCES↗

SU-F-T-70: A High Dose Rate Total Skin Electron Irradiation Technique with A Specific Inter-Film Variation Correction Method for Very Large Electron Beam Fields

Purpose: Rotational total skin electron irradiation (RTSEI) is used in the treatment of cutaneous T-cell lymphoma. Due to inter-film uniformity variations the dosimetry measurement of a large electron beam of a very low energy is challenging. This work provides a method to improve the accuracy of flatness and symmetry for a very large treatment field of low electron energy used in dual beam RTSEI. Methods: RTSEI is delivered by dual angles field a gantry of ±20 degrees of 270 to cover the upper and the lower halves of the patient body with acceptable beam uniformity. The field size is in the order of 230cm in vertical height and 120 cm in horizontal width and beam energy is a degraded 6 MeV (6 mm of PMMA spoiler). We utilized parallel plate chambers, Gafchromic films and OSLDs as a measuring devices for absolute dose, B-Factor, stationary and rotational percent depth dose and beam uniformity. To reduce inter-film dosimetric variation we introduced a new specific correction method to analyze beam uniformity. This correction method uses some image processing techniques combining film value before and after radiation dose to compensate the inter-variation dose response differences among films. Results: Stationary and rotational depth of dose demonstrated that the Rp is 2 cm for rotational and the maximum dose is shifted toward the surface (3mm). The dosimetry for the phantom showed that dose uniformity reduced to 3.01% for the vertical flatness and 2.35% for horizontal flatness after correction thus achieving better flatness and uniformity. The absolute dose readings of calibrated films after our correction matched with the readings from OSLD. Conclusion: The proposed correction method for Gafchromic films will be a useful tool to correct inter-film dosimetric variation for the future clinical film dosimetry verification in very large fields, allowing the optimizations of other parameters.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-13: Spatial Accuracy Evaluation for Real-Time MR Guided Radiation Therapy Using a Novel Large-Field MRI Distortion Phantom

Purpose: Evaluate a large-field MRI phantom for assessment of geometric distortion in whole-body MRI for real-time MR guided radiation therapy. Methods: A prototype CIRS large-field MRI distortion phantom consisting of a PMMA cylinder (33 cm diameter, 30 cm length) containing a 3D-printed orthogonal grid (3 mm diameter rods, 20 mm apart), was filled with 6 mM NiCl{sub 2} and 30 mM NaCl solution. The phantom was scanned at 1.5T and 3.0T on a GE HDxt and Discovery MR750, respectively, and at 0.35T on a ViewRay system. Scans were obtained with and without 3D distortion correction to demonstrate the impact of such corrections. CT images were used as a reference standard for analysis of geometric distortion, as determined by a fully automated gradient-search method developed in Matlab. Results: 1,116 grid points distributed throughout a cylindrical volume 28 cm in diameter and 16 cm in length were identified and analyzed. With 3D distortion correction, average/maximum displacements for the 1.5, 3.0, and 0.35T systems were 0.84/2.91, 1.00/2.97, and 0.95/2.37 mm, respectively. The percentage of points with less than (1.0, 1.5, 2.0 mm) total displacement were (73%, 92%, 97%), (54%, 85%, 97%), and (55%, 90%, 99%), respectively. A reduced scan volume of 20 × 20 × 10 cm{sup 3} (representative of a head and neck scan volume) consisting of 420 points was also analyzed. In this volume, the percentage of points with less than (1.0, 1.5, 2.0 mm) total displacement were (90%, 99%, 100%), (63%, 95%, 100%), and (75%, 96%, 100%), respectively. Without 3D distortion correction, average/maximum displacements were 1.35/3.67, 1.67/4.46, and 1.51/3.89 mm, respectively. Conclusion: The prototype large-field MRI distortion phantom and developed software provide a thorough assessment of 3D spatial distortions in MRI. The distortions measured were acceptable for RT applications, both for the high field strengths and the system configuration developed by ViewRay.

60 APPLIED LIFE SCIENCES↗

A 3D extra-large-pore zeolite enabled by 1D-to-3D topotactic condensation of a chain silicate

Zeolites are microporous silicates with a large variety of applications as catalysts, adsorbents, and cation exchangers. Stable silica-based zeolites with increased porosity are in demand to allow adsorption and processing of large molecules but challenge our synthetic ability. We report a new, highly stable pure silica zeolite called ZEO-3, which has a multidimensional, interconnected system of extra-large pores open through windows made by 16 and 14 silicate tetrahedra, the least dense polymorph of silica known so far. This zeolite was formed by an unprecedented one-dimensional to three-dimensional (1D-to-3D) topotactic condensation of a chain silicate. With a specific surface area of more than 1000 square meters per gram, ZEO-3 showed a high performance for volatile organic compound abatement and recovery compared with other zeolites and metal-organic frameworks.

Science & Technology - Other Topics↗

Large $$N_c$$ QCD phase diagram at $$\mu _B=0$$

Abstract Lattice studies suggest that at zero baryon chemical potential and increasing temperature there are three characteristic regimes in QCD that are connected by smooth analytical crossovers: a hadron gas regime at$$T < T_{ch}\sim 155$$ T < T ch ∼ 155 MeV, an intermediate regime, called stringy fluid, at$$T_{ch}< T < \sim 3 T_{ch}$$ T ch < T < ∼ 3 T ch , and a quark-gluon plasma regime at higher temperatures. These regimes have been interpreted to reflect different approximate symmetries and effective degrees of freedom. In the hadron gas the effective degrees of freedom are hadrons and the approximate chiral symmetry of QCD is spontaneously broken. The intermediate regime has been interpreted as lacking spontaneous chiral symmetry breaking along with the emergence of new approximate symmetry, chiral spin symmetry, that is not a symmetry of the Dirac Lagrangian, but is a symmetry of the confining part of the QCD Lagrangian. While the high temperature regime is the usual quark-gluon plasma which is often considered to reflect “deconfinement” in some way. This paper explores the behavior of these regimes of QCD as the number of colors in the theory,$$N_c$$ N c , gets large. In the large$$N_c$$ N c limit the theory is center-symmetric and notions of confinement and deconfinement are unambiguous. The energy density is$$\mathcal{O}(N_c^0)$$ O ( N c 0 ) in the meson gas,$${{\mathcal {O}}}(N_c^1)$$ O ( N c 1 ) in the intermediate regime and$${{\mathcal {O}}}(N_c^2)$$ O ( N c 2 ) in the quark-gluon plasma regime. In the large$$N_c$$ N c limit these regimes may become distinct phases separated by first order phase transitions. The intermediate phase has the peculiar feature that glueballs should exist and have properties that are unchanged from what is seen in the vacuum (up to$$1/N_c $$ 1 / N c corrections), while the ordinary dilute gas of mesons with broken chiral symmetry disappears and approximate chiral spin symmetry should emerge.

Physics↗

Large $N$ approach to kaon decays and mixing 28 years later: $\Delta I = 1/2$ rule, $\hat B_K$ and $\Delta M_K$

We review and update our results for K → π π decays and K⁰- K¯⁰ mixing obtained by us in the 1980s within an approach based on the dual representation of QCD as a theory of weakly interacting mesons for large N colours. In our analytic approach the dynamics behind the enhancement of ReA 0 and suppression of ReA 2 , the so-called ΔI = 1/2 rule for K → π π decays, has a simple structure: the usual octet enhancement through quark-gluon renormalization group evolution down to the scales O(1 GeV) is continued as a meson evolution down to zero momentum scales at which the factorization of hadronic matrix elements is at work. The inclusion of lowest-lying vector meson contributions in addition to the pseudoscalar ones and of Wilson coefficients in a momentum scheme improves significantly the matching between quark-gluon and meson evolutions. In particular, the anomalous dimension matrix governing the meson evolution exhibits the structure of the known anomalous dimension matrix in the quark-gluon evolution. The recent results on ReA 2 and ReA 0 from the RBC-UKQC collaboration give support for our approach. In particular, the signs of the two main contractions found numerically by these authors follow uniquely from our analytic approach. At NLO in 1/N we obtain R = ReA 0 /ReA 2 = 16.0±1.5 which amounts to an order of magnitude enhancement over the strict large N limit value √2. QCD penguins contribute at 15% level to this result. We also find B^ K = 0.73± 0.02, with the smallness of 1/N corrections to the large N value B^ K = 3/4 resulting within our approach from an approximate cancellation between pseudoscalar and vector meson one-loop contributions. We summarize the status of ΔM K in this approach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for metastable heavy charged particles with large ionisation energy loss in pp collisions at ${\sqrt{s} = 8}$ s = 8 TeV using the ATLAS experiment

Many extensions of the Standard Model predict the existence of charged heavy long-lived particles, such as R-hadrons or charginos. These particles, if produced at the Large Hadron Collider, should be moving non-relativistically and are therefore identifiable through the measurement of an anomalously large specific energy loss in the ATLAS pixel detector. Measuring heavy long-lived particles through their track parameters in the vicinity of the interaction vertex provides sensitivity to metastable particles with lifetimes from 0.6 ns to 30 ns. A search for such particles with the ATLAS detector at the Large Hadron Collider is presented, based on a data sample corresponding to an integrated luminosity of \(18.4\) fb\(^{-1}\) of pp collisions at \(\sqrt{s} = 8\) TeV. No significant deviation from the Standard Model background expectation is observed, and lifetime-dependent upper limits on R-hadrons and chargino production are set. Gluino R-hadrons with 10 ns lifetime and masses up to 1185 GeV are excluded at 95 \(\%\) confidence level, and so are charginos with 15 ns lifetime and masses up to 482 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for new phenomena in events containing a same-flavour opposite-sign dilepton pair, jets, and large missing transverse momentum in ${\sqrt{s}=13}$$\text {TeV}$ ${pp}$ collisions with the ATLAS detector

Two searches for new phenomena in final states containing a same-flavour opposite-sign lepton (electron or muon) pair, jets, and large missing transverse momentum are presented. These searches make use of proton–proton collision data, collected during 2015 and 2016 at a centre-of-mass energy √s = 13 TeV by the ATLAS detector at the large hadron collider, which correspond to an integrated luminosity of 14.7 fb –1 . Both searches target the pair production of supersymmetric particles, squarks or gluinos, which decay to final states containing a same-flavour opposite-sign lepton pair via one of two mechanisms: a leptonically decaying Z boson in the final state, leading to a peak in the dilepton invariant-mass distribution around the Z boson mass; and decays of neutralinos (e.g. χ ~0 2 → ℓ + ℓ – χ ~0 1 ), yielding a kinematic endpoint in the dilepton invariant-mass spectrum. The data are found to be consistent with the Standard Model expectation. Results are interpreted in simplified models of gluino-pair (squark-pair) production, and provide sensitivity to gluinos (squarks) with masses as large as 1.70 TeV (980 GeV).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of the reconstruction of large impact parameter tracks in the inner detector of ATLAS

Searches for long-lived particles (LLPs) are among the most promising avenues for discovering physics beyond the Standard Model at the Large Hadron Collider (LHC). However, displaced signatures are notoriously difficult to identify due to their ability to evade standard object reconstruction strategies. In particular, the ATLAS track reconstruction applies strict pointing requirements which limit sensitivity to charged particles originating far from the primary interaction point. To recover efficiency for LLPs decaying within the tracking detector volume, the ATLAS Collaboration employs a dedicated large-radius tracking (LRT) pass with loosened pointing requirements. During Run 2 of the LHC, the LRT implementation produced many incorrectly reconstructed tracks and was therefore only deployed in small subsets of events. In preparation for LHC Run 3, ATLAS has significantly improved both standard and large-radius track reconstruction performance, allowing for LRT to run in all events. This development greatly expands the potential phase-space of LLP searches and streamlines LLP analysis workflows. This paper will highlight the above achievement and report on the readiness of the ATLAS detector for track-based LLP searches in Run 3.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗