Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “intervals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

SU-E-J-274: Responses of Medulloblastoma Cells to Radiation Dosimetric Parameters in Intensity-Modulated Radiation Therapy

Purpose: To evaluate radiation responses of the medulloblastoma cell line Daoy in intensity-modulated radiation therapy (IMRT), quantitative variations to variable radiation dosimetic parameters were tracked by bioluminescent images (BLIs). Methods: The luciferase and green fluorescent protein positive Daoy cells were cultured on dishes. The medulloblastoma cells irradiated to different dose rate, interval of fractionated doses, field margin and misalignment, and dose uniformity in IMRT were monitored using bioluminescent images. The cultured cells were placed into a dedicated acrylic phantom to deliver intensity-modulated fluences and calculate accurate predicted dose distribution. The radiation with dose rate from 0.5 Gy/min to 15 Gy/min was irradiated by adjusting monitor unit per minute and source-to-surface distances. The intervals of fractionated dose delivery were changed considering the repair time of double strand breaks (DSB) revealed by straining of gamma-H2AX.The effect of non-uniform doses on the cells were visualized by registering dose distributions and BLIs. The viability according to dosimetric parameters was correlated with bioluminescent intensities for cross-check of radiation responses. Results: The DSB and cell responses due to the first fractionated dose delivery significantly affected final tumor control rather than other parameters. The missing tumor volumes due to the smaller field margin than the tumor periphery or field misalignment caused relapse of cell responses on BLIs. The dose rate and gradient had effect on initial responses but could not bring out the distinguishable killing effect on cancer cells. Conclusion: Visualized and quantified bioluminescent images were useful to correlate the dose distributions with spatial radiation effects on cells. This would derive the effective combination of dose delivery parameters and fractionation. Radiation responses in particular IMRT configuration could be reflected to image based-dose re-optimization.

60 APPLIED LIFE SCIENCES↗

SU-E-T-497: Initial Characterization of a Novel 2D Computed Radiography (CR) Dosimeter for SBRT

Purpose For 2D, sub-mm resolution dose measurements Gafchromic™ film is currently a standard in radiotherapy; mainly because of its energy independence and water equivalence. However, EBT film is disposable. Therefore, the dosimetric and uniformity characteristics needs to be estimated from a second, possibly different, (calibration) film. Moreover, EBT has a post-irradiation coloration and a non-linear dose dependence with saturation, which limits the applicable time interval and dose range. CR technology forms an interesting alternative for EBT. Dose dependent CRplates have a sub-mm resolution, and additionally a linear dose dependence over decades of dose. But, CR has an inherent signal fading and energy dependence. Here, for the first time, a radiotherapy 2D CR prototype was characterized for an extended dose range (up to 35Gy), signal fading, and basic energy dependence. Methods The prototype was irradiated with a standard 10×10cm 6MV photon beam, and scanned with a commercial CR 15-X(R) scanner. The time between the start of irradiation and scanning (T-Scan) was monitored. The linearity of the dose response was evaluated between 0 and 35Gy using a fixed T-Scan of 4min, if possible (i.e. ≤10Gy). Next, the signal fading was characterized for a T-Scan-range of 4 to 20min. The energy dependence was assessed by a comparison of out-of-field measurements of CR, EBT, and TLD. Results The radiotherapy CR prototype has a linear response over the complete SBRT dose range (0– 35Gy). The prototype had a small (5%), but linear signal fading over the time interval of interest (4–20min). Out-of-field, the prototype has a 8% over response due to an increased amount of low energy photons. The impact of the over response on intensity modulated radiotherapy remains to be evaluated. Conclusion CR technology is promising for SBRT dose measurements up to 35Gy. It is a reusable linear alternative for film dosimetry.

60 APPLIED LIFE SCIENCES↗

SU-E-T-620: Planning and Dosimetry for Pulsed Low Dose Rate RT for Recurrent Lung, Spine, GYN and Head and Neck Cancers

Purpose: Extensive in vitro and in vivo studies have shown that pulsed low dose rate (PLDR) radiotherapy has potential to provide significant local tumor control and to reduce normal tissue toxicities. This work investigated the planning and dosimetry of PLDR re-irradiation for recurrent cancers. Methods: We analyzed the treatment plans and dosimetry for 13 recurrent patients who were treated with the PLDR technique in this study. All cases were planned with the 3DCRT technique with optimal beam angle selection. The treatment was performed on a Siemens accelerator using 6MV beams. The target volume ranged between 161 and 703cc. The previous RT dose was 40–60Gy while the re-irradiation dose was 16–60Gy. The interval between previous RT and re-irradiation was 13–336 months, and the follow-up time was up to 27months. The total prescription dose was administered in 2Gy/day fractions with the daily dose delivered in 10 sub-fractions (pulses) of 20cGy with a 3min interval between the pulses to achieve an effective dose rate of 6.7cGy/min. Results: The clinical outcome was analyzed based on the treatment plans. All pulses were kept with Dmax<40cGy. The PLDR treatments were effective (CR: 3 patients, PR: 10 patients). The acute and late toxicities were all acceptable (generally grade II or under). Two patients died three months after the PLDR re-irradiation, one due to massive cerebral infarction and the other due to acute cardiac failure. All others survived more than 8 months. Five patients showed good conditions at the last follow-up. Among them two recurrent lung cancer patients had survived 23 months and one nasopharyngeal cancer patient had survived 27 months. Conclusion: The PLDR technique was effective for the palliative treatment of head and neck, lung, spine and GYN cancers. Further phase II and III studies are warranted to quantify the efficacy of PLDR for recurrent cancers.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-EF-204-11: Impact of Using Multi-Slice Training Sets On the Performance of a Channelized Hotelling Observer in a Low-Contrast Detection Task in CT

Purpose: To investigate using multiple CT image slices from a single acquisition as independent training images for a channelized Hotelling observer (CHO) model to reduce the number of repeated scans for CHO-based CT image quality assessment. Methods: We applied a previously validated CHO model to detect low contrast disk objects formed from cross-sectional images of three epoxy-resin-based rods (diameters: 3, 5, and 9 mm; length: ∼5cm). The rods were submerged in a 35x 25 cm2 iodine-doped water filled phantom, yielding-15 HU object contrast. The phantom was scanned 100 times with and without the rods present. Scan and reconstruction parameters include: 5 mm slice thickness at 0.5 mm intervals, 120 kV, 480 Quality Reference mAs, and a 128-slice scanner. The CHO’s detectability index was evaluated as a function of factors related to incorporating multi-slice image data: object misalignment along the z-axis, inter-slice pixel correlation, and number of unique slice locations. In each case, the CHO training set was fixed to 100 images. Results: Artificially shifting the object’s center position by as much as 3 pixels in any direction relative to the Gabor channel filters had insignificant impact on object detectability. An inter-slice pixel correlation of >∼0.2 yielded positive bias in the model’s performance. Incorporating multi-slice image data yielded slight negative bias in detectability with increasing number of slices, likely due to physical variations in the objects. However, inclusion of image data from up to 5 slice locations yielded detectability indices within measurement error of the single slice value. Conclusion: For the investigated model and task, incorporating image data from 5 different slice locations of at least 5 mm intervals into the CHO model yielded detectability indices within measurement error of the single slice value. Consequently, this methodology would Result in a 5-fold reduction in number of image acquisitions. This project was supported by National Institutes of Health grants R01 EB017095 and U01 EB017185 from the National Institute of Biomedical Imaging and Bioengineering.

60 APPLIED LIFE SCIENCES↗

Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the quantitative histogram parameters of volume transfer constant [standard deviation (SD), 98th percentile, and range], rate constant (SD), blood volume fraction (mean, SD, 98th percentile, and range), and blood flow (mean, SD, median, 98th percentile, and range) for sampling intervals between 10 and 15 s. Conclusions: The proposed method of PCA filtering combined with the AIF estimation technique allows low frequency scanning for DCE-CT study to reduce patient radiation dose. The results indicate that the method is useful in pixel-by-pixel kinetic analysis of DCE-CT data for patients with cervical cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-39: Comparing Nomograms for Ordering of Palladium-103 Seeds for Dynamic Intraoperative Prostate Seed Implantation

Purpose: Several nomograms exist for the purpose of ordering palladium- 103 seeds for permanent prostate seed implants. Excess seeds pose additional radiation safety risks and increase the cost of care. This study compared three seed ordering nomograms with seed counts from dynamic intra-operative PSI to determine (1) the cause of excess seeds and (2) the optimal nomogram for our institution. Methods: Pre-operative and intra-operative clinical data were collected for 100 Gy (n=151) and 125 Gy (n=224) prostate seed implants. The number of implanted seeds which would have given D90=100% was normalized to that criteria and seed strength of 2U. This was plotted against intra-operative prostate volume and compared to two previously published nomograms and an in-house nomogram. A linear fit was produced and confidence intervals were calculated. The causes of excess seeds were assessed by comparing pre- and intra-operative prostate volumes, variability of D90 around 100%, and variance of seed strength from 2U. Results: Of the 375 total cases, 97.6% had excess seeds. On average, 27.17±12.91% of ordered seeds were wasted. Of this percentage, 6.98±5.47% of excess seeds were due to overestimation of pre-operative prostate volume, 1.10±0.88% were due to D90<100%, 1.17±0.67% were due to seed strength over 2U, and 17.36±7.79% could not be directly attributed to a specific reason. The latter percentage may be due to overestimation of the in-house nomogram. Two of three nomograms substantially overestimated the number of seeds required. The third nomogram underestimated the required seed number for smaller prostate treatment volume. A linear fit to the clinical data was derived and 99.9% confidence intervals were calculated. Conclusion: Over 85% of clinical cases wasted over 15% of ordered seeds. Two of three nomograms overestimated the required number of seeds. The upper 99.9% C.I. of the clinical data may provide a more reasonable nomogram for Pd-103 seed ordering.

60 APPLIED LIFE SCIENCES↗

SU-F-T-282: Quality Assurance for IMRT/VMAT QA Devices: Issues Affecting the Timing for ArcCHECK Recalibration

Purpose: To discuss several factors surrounding the decision on when to recalibrate the ArcCHECK device as well as present a simple and efficient monthly check to evaluate ArcCHECK calibrations. Methods: ArcCheck (Sun Nuclear) calibrations were evaluated monthly by measuring a 25×25cm{sup 2} field with 100 MU. Since ArcCHECK measurements are run on an almost nightly basis, such additional square field measurements are obtained with minimal additional effort. An in-house MATLAB script compares two radial (y-direction) profiles from the top/center of the new measurement relative to a baseline measurement acquired at the last device calibration. The program automatically generates PDF profile and percent difference comparisons for inspection. Recalibration is based on inspection of measurement profile shapes and percent differences from the baseline measurement. Results: The method presented here shows the utility of a simple monthly check for evaluating ArcCHECK calibrations, and in addition shows the importance of recalibrating after Linac beam steering. Our device required recalibration approximately every 8–10 months. However, for ease of scheduling, we propose a bi-annual recalibration interval. Clinics with a lighter/heavier IMRT/VMAT QA case load may require different recalibration intervals, which are easily determined using the single-field method presented. Analysis of additional square fields is also easily incorporated, if desired. We further illustrate the importance of array recalibration given that diode irradiation is not uniform over the entire device, with central diodes receiving more than 900 Gy over the course of 10 months and peripheral diodes receiving as little as 50 Gy (in our experience). Finally, we show that timely device recalibration decreases spread in clinical IMRT/VMAT QA gamma passing rates. Conclusion: Quality assurance for ArcCHECK array calibrations is important to ensure quality IMRT/VMAT QA comparisons. For many clinics, calibrations should be performed at least annually, if not more frequently, based on use of the proposed monthly check.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP3-07: On the Development of Mechano-Biological Assessment of Leukemia Cells Using Optical Tweezers

Purpose: Patients with BCR-ABL (Ph +ve) acute lymphoblastic leukemia are at very high risk of relapse and mortality. In line with the NIH mission to understand the physical and biological processes, we seek to report mechano-biological method to assessment and distinguish treated/untreated leukemia cells. Methods: BCR-ABL leukemia cell populations and silica microspheres were trapped in a 100x magnification optical trapping system (λ=660 nm, 70 mW). Light refracted through the trapped sample was collected in the back focal plane by a quadrant detector to measure the positions of individual cells. The sample was driven at a known frequency and amplitude with a flexure translation stage, and the target’s response was recorded. The measured response was calibrated using the known driving parameters, and information about cell movements due to mechano-biological effects was extracted. Two leukemia cell populations were tested: a control group and a group treated with 2 Gy. Results: The mechano-biological movements of 10 microspheres, control cells, and treated cells were tracked over a ∼30 minute window at 1 minute intervals. The microsphere population did not see significant change in mechano-biological movements over the testing interval and remained constant. The control cell population saw a two-fold rise in activity that peaked around 1200 seconds, then dropped off sharply. The treated cell population saw a two-fold rise in activity that peaked at 400 seconds, and dropped off slowly. Conclusion: The investigated technique allows for direct measurement the movements of a trapped object due to mechano-biological effects such as thermal and extracellular motion. When testing microspheres, the mechano-biological activity remained constant over time due to the lack of biological factors. In both the control and treated cell populations, the mechano-biological activity was increased, possibly due to mitochondrial activation. This extra activity decreased over time, possibly due to cellular damage from trapping radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-FG-209-07: Medical Physics 1.0 Versus Medical Physics 2.0: A Case Study

Purpose: To illustrate how performance analytics can identify performance decrement in digital radiography systems. Methods: Subsequent to a radiologist’s image quality complaint, four different advanced methods contributed to root cause analysis. Our system was a GE Revolution XQi digital radiography unit. Initially, we reviewed weekly GE Quality Assurance Procedures (QAP) results in a database dating from 2001. Next, we evaluated objective image quality metrics of individual PA Chest radiographs acquired. These images were anonymized, securely transferred, and analyzed by the Duke University Clinical Imaging Physics Group with software previously described{sup 1} and validated{sup 2}. Third, we compared the exposure-dependent SNR{sup 2} (NEQ) of the unit with previously established confidence limits{sup 3}. Finally, we explored our service database to reveal events that might affect detector performance. Results: QAP reported a decrease in CNR reflected in a significant increase in lung noise(Ln), mediastinum noise(Mn), and subdiaphragm-lung contrast(Slc) with a significant decrease in lung grey level(Lgl) after detector replacement. Most change occurred during week 1, before the QAP indicated one-half the ultimate decrease in CNR. After detector recalibration, QAP CNR improved, but was not restored to previous levels. Lgl and Slc were no longer significantly different from before, however Ln and Mn remained significantly different. Exposure-dependent SNR2 show the detector to be operating within limits in October 2006 but subsequently became miscalibrated sometime before acquisition of the 2011–2014 data. Service records revealed catastrophic failure of the Image Detection Controller that contained the 2007 calibration. Traditional metrics did not indicate that the system was performing outside of normal limits. Conclusion: Performance analytics are powerful tools whose proper application could allow early intervention in degraded system performance. The image-quality metrics appear to be highly sensitive to system performance and are reported with every acquisition rather than at arbitrary intervals. Confidence intervals may require customization for individual systems or detectors.

60 APPLIED LIFE SCIENCES↗

WE-H-BRA-02: Radiobiological Modeling of Tumor Control Probability (TCP) and Radiation-Induced Pneumonitis (RP) for Lung Cancer Patients Treated with Monte Carlo-Based Lung SBRT

Purpose: To present radiobiological modeling of TCP using tumor size-adjusted BED(s-BED)and PTV(D99) to lung SBRT patients treated with X-ray Voxel Monte Carlo(XVMC) algorithm, apply parameterized Lyman-NTCP model to predict grade-2 RP and subsequently, compare with clinical outcomes/observations. Methods: Dosimetric parameters and clinical follow-up for XVMC-based lung-SBRT patients were retrospectively evaluated. Patients were treated at Novalis-TX with hybrid(2 non-coplanar partial-arcs plus 3–6 static-beams)plan using HD-MLC/6MV-SRS-beam.For TCP,s-BED modelling was utilized: TCP=EXP[sBED-TCD50]/k/(1.0+EXP[sBED-TCD50]/k), where k=31Gy corresponding to TCD50=0Gy and s-BED was defined as BED10 minus 10 times the tumor diameter(in centimeters)by Ohri et al.(IJROBP,2012). For 2-yr local-control, we used more-realistic MC-computed PTVD99 as a predictive parameter, s-BED(D99).Due to relatively shorter median follow-up interval(12-months),Kaplan-Meier curves were generated to estimate 2-yr observed local-control and compared to predicted-rate by TCP modeling. For NTCP, we employed parameterized Lyman-NTCP model utilizing normal-lung DVH and α/β=3Gy fitted to predict grade-2 RP after lung-SBRT. Results: Total 108 patients (137 tumors) treated for 35–70Gy in 3–5 fractions, either primary-lung(n=74)or metastatic-lung(n=53)tumors were included.F or the given prescription dose with MC-computed MUs, 2-yr local-control rates with s-BED(D99) was 87±8%. Kaplan-Meier generated observed local-control rate at 2-yr was 87.5%,suggesting that PTV(D99) could be a potential predictor (p-value=0.38). Observed vs predicted TCP for primary-lung tumors and metastatic tumors were 97% vs 88±7% and 94% vs 86±9%.NTCP model predicted well for symptomatic-RP with predicted vs observed (3±5% vs 2%). Radiographic and clinically significant RP was observed in 13% and 2% of patients. Higher rates of radiographic change were observed in patients who received >50Gy compared to ≤50Gy(24% vs 10%). Conclusion: Utilizing MC-computed PTVD99, our TCP results were well correlated with clinical outcome. The predicted grade-2 RP rate was comparable to clinical observations. Clinical application of these radiobiological models may potentially allow for target dose escalation and/or lung-toxicity reduction. Further validation of these radiobiological models with longer follow up interval for large cohorts of lung-SBRT patients is anticipated.

60 APPLIED LIFE SCIENCES↗

Climate impact on fluvial-lake system evolution, Eocene Green River Formation, Uinta Basin, Utah, USA

In light of a modern understanding of early Eocene greenhouse climate fluctuations and new highly seasonal fluvial system faces models, the role of climate in the evolution of one classically-cited continental, terminal lake system is re-examined. Detailed stratigraphic description and elemental abundance data from fifteen cores and seven outcrop regions of the Green River Formation were used to construct a ~150 km cross section across the Uinta Basin, Utah, USA. Lake Uinta in the Uinta Basin is divided into five lake phases: (1) post-Paleocene Eocene Thermal Maximum, (2) peak Eocene hyperthermal, (3) waning hyperthermal, Early Eocene Climatic Optimum (EECO), (4) post-hyperthermal, and (5) post-EECO regimes, based primarily on climatically driven changes in fluvial style in combination with sedimentary indicators of lacustrine carbonate deposition, organic matter preservation, salinity, and lake depth. Basinwide siliciclastic dominated intervals were deposited by highly seasonal fluvial systems and record negative organic carbon isotope excursions associated with early Eocene abrupt, transient global warming (hyperthermal) events. Carbonate dominated or organic rich intervals record stable, less seasonal climate periods between hyperthermals, with lower siliciclastic sediment supply allowing the development of carbonate and organic matter preservation. The stratigraphic progression from alternating organic rich and lean zones to the overlying organic rich Mahogany and R8 zones represents the global transition out of the pulsed early Eocene hyperthermal climate regime to a time of sediment starvation and lake stratification, sequestering sedimentary organic carbon. This study provides a novel approach to terrestrial paleoclimate reconstruction that relies largely on unique sedimentary indicators and secondarily on isotopic proxy records within the context of a large basin-wide sedimentologic and stratigraphic data set, thus setting the stage for future detailed geochemical terrestrial paleoclimate proxy development.

Geology↗

Near-constant retreat rate of a terrestrial margin of the Laurentide Ice Sheet during the last deglaciation

The Laurentide Ice Sheet (LIS) was the largest ice sheet during the last glacial period. An accurate representation of its behavior during the last deglaciation is critical to understanding its influence on and response to a changing climate. Here we use 10 Be dating and Bayesian modeling to track the recession of the southwest sector of the Labrador Dome of the LIS along an ~500-km-long transect west of Lake Superior during the last deglaciation. This transect reflects terrestrial ice-margin retreat and crosses multiple moraine sets, with the southwestern part of the transect deglaciated by ca. 19 ka and the northeastern part deglaciated by ca. 10 ka. The predominant behavior of the ice margin during this interval is near-constant retreat with retreat rates varying between ~59 m/a and 38 m/a. The moraine sets mark standstills and/or readvances that in total constitute only ~17% of the retreat interval. The spatial and temporal pattern of ice-margin retreat tracked here differs from existing reconstructions that are based on using isochrons to define ice-margin positions. Acknowledging the uncertainties associated with the modeled ages of ice-margin retreat, we suggest that the overall retreat pattern is consistent with forcing by a gradual increase in Northern Hemisphere, high-latitude summer insolation. The pattern of ice-margin retreat is inconsistent with Greenland ice-core temperature records, and thus these records may not be suitable to drive models of the LIS.

58 GEOSCIENCES↗

Equation of state and structural transition at high hydrostatic pressures in the BiFeO[subscript 3] crystal

Change in the crystal structure of the BiFeO{sub 3} multiferroic at high pressures up to 70 GPa in a diamond anvil cell has been studied by the method of synchrotron x-ray diffraction at room temperature. The experiment has been carried out under hydrostatic conditions with helium as a pressure-transferring medium. An anomaly has been observed in the behavior of the structural parameters at pressures P{sub c} {approx} 40-50 GPa. This anomaly correlates with the effect of the magnetic collapse of iron moments revealed in this pressure range. It has been found that the bulk compression modulus is equal to B{sub 0} = (75.5 {+-} 15.5) GPa in the interval 0 < P < P{sub c} and is almost quadrupled to a value of B = (292 {+-} 9) GPa in the interval P > P{sub c}. When the pressure decreases, the behavior of the structural parameters is completely reversible in correlation with the reversibility of the magnetic transition. The 'diffuseness' of the structural transition in pressure is explained by thermal fluctuations between the high-and low-spin states of Fe{sup 3+} ions in the transition region.

36 MATERIALS SCIENCE↗

Spectral-Kinetic Characteristics of Laser Ignition of Pulverized Brown Coal

In this study, we measured the spectral-kinetic characteristics of ignition of dustlike (pulverized) coal particles with a particle size of ≤100 μm using an yttrium-aluminum garnet laser with an admixture of neodymium operating in the free-running mode (120 μs). We discovered three stages of the process, each of which has a threshold character. During the laser pulse in the energy density range of 0.3–1.5 J/cm{sup 2}, a rapid heating of the sample surface to 3000 K occurs due to the absorption of laser energy and initiation of a chemical reaction in the coal particles. In the energy density range of 1.6–2.1 J/cm{sup 2}, the yield and ignition of volatile matter above the sample surface are observed in the time interval of 0.5–2 ms. In the emission spectra of the flame, we are able to distinguish bands associated with the combustion of volatile matter including the CO flame and the emission of excited H{sub 2}O and H{sub 2} molecules. At H > 2 J/cm{sup 2}, ignition and burning of the coke residue takes place in a time interval of 10–100 ms. Its emission spectrum corresponds to the emission spectrum of a black body at 1800 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum Key Distribution with Temporal Coding of Time-Bin Qubits

In this study, we demonstrate the possibility of realizing the quantum key distribution system by temporal coding of time-bin qubits that are prepared and measured using unbalanced Mach-Zehnder interferometers. We also show that, to exclude a clear a priori identification of time-bin qubits with equal bases, their encoding with the symbols 0 and 1 can be accomplished by delaying one of them by half the clock interval. The uniqueness of measurements of qutrits in this algorithm is shown to be based on the ability of quantum particles in β-states to interfere with the probability amplitudes at the ports of the system interferometers, as well as the absence of collisions of signaling states of the qutrits in adjacent clock intervals. We describe a method for controlling such collisions, including those that are based on qubits prepared from quasi-one-photon coherent laser states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quasiparticles in Raman scattering of an electromagnetic wave by an atomic condensate

Raman scattering of an intense electromagnetic wave by a free atomic Bose condensate is considered. In a system of atoms and photons, a subsystem is separated whose dynamics can be naturally described in terms of quasiparticles: quasi-atoms and quasi-photons. The dispersion laws of quasiparticles are interrupted by the instability interval. The introduction of quasiparticles within this interval is impossible, while dispersion laws that are continued formally acquire imaginary components. The dynamic scattering model is generalized by including dissipative annihilation processes of scattered photons and uncondensed atoms. A stationary solution of the corresponding quantum control equation is found, allowing the calculation of momentum distributions of real particles and quasiparticles. The outlook for the experimental detection of quasiparticles is discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Superconducting plate in a transverse magnetic field: New state

A model is proposed for describing Cooper pairs near the transition (in temperature and magnetic field) point when their spacing is larger than their size. The essence of the model is as follows: the Ginzburg-Landau functional is written in operator form in terms of field operators of the Bose type so that the average value of the density operator gives the concentration of Cooper pairs, and the same Ginzburg-Landau expression is obtained for the Bose condensate. The model is applied to a superconducting plate with a thickness smaller than the size of a pair in a transverse magnetic field near its upper critical value H{sub c2}. A new state is discovered that is energetically more advantageous in a certain interval in the vicinity of the transition point as compared to the Abrikosov vortex state. The wavefunction of the system in this state is of the type of the Laughlin function used in the fractional quantum Hall effect (naturally, as applied to Cooper pairs as Bose particles in our case) and corresponds to a homogeneous incompressible fluid. The energy of this state is proportional to the first power of quantity (1 - H/H{sub c2}) in contrast to the energy of the vortex state containing the square of this quantity. The interval of the existence of the new state is the larger, the dirtier the sample.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗