Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Behavior of soda-lime silicate glass under laser-driven shock compression up to 315 GPa

Shock experiments give a unique insight into the behavior of matter subjected to extremely high pressures and temperatures. Understanding the behavior of materials under such extreme conditions is key to modeling material failure and deformation dynamics under impact. While studies on pure silica are extensive, the shock behavior of other commercial silicates that contain additional oxides has not been systematically investigated. To better understand the role of composition in the dynamic behavior of silicates, we performed laser-driven dynamic compression experiments on soda-lime glass (SLG) up to 315 GPa. Using the accurate pulse shaping offered by the long pulse laser system at the Matter in Extreme Conditions end-station at the Linac Coherent Light Source, SLG was shock compressed along the Hugoniot to multiple pressure-temperature points. Velocity Interferometer System for Any Reflector was used to measure the velocity and determine the pressure inside the SLG. The U s –u p relationship obtained agrees well with the previous parallel plate impact studies. Within the error bars, no transformation to the crystalline phase was observed up to 70 GPa, which is in contrast to the behavior of pure silica under shock compression. Our studies show that the glass composition strongly influences the shock compression behavior of the silicate glasses.

36 MATERIALS SCIENCE↗

Measurement of helicon waves with phase contrast imaging on DIII-D – A theoretical feasibility study

A DIII-D high-beta H-mode discharge, with I p = 850 kA, B t = 2.1 T n e = 4 10 19 m –3 , has been designed to validate full wave modeling of helicon waves by optimizing the expected response of the Phase Contrast Imaging diagnostic. Helicon waves have been predicted to have high current drive efficiency off-axis without facing the accessibility issues of lower-hybrid waves. To test these predictions experimentally, DIII-D has recently commissioned a high-power helicon antenna. To confidently predict the behavior of helicon waves in future devices, measurements of their fundamental properties and validation against models will be essential. Phase contrast imaging (PCI) is an absolutely calibrated internal reference interferometer able to measure density fluctuations with radial wavenumbers k R between 1.5 cm –1 and 20 cm –1 . For helicon waves 2 cm –1 < k R < 10 cm –1 is expected, allowing PCI to measure their envelope and wavenumber spectrum. This makes PCI a powerful tool for the validation of state-of-the-art models, like the AORSA full wave code. AORSA is used to compute the density perturbations measured by the PCI with 2D calculations corresponding to 11 different toroidal mode numbers combined to resolve the trajectory of the helicon wave in 3D. This is necessary because the waves travel 120 degrees toroidally from the antenna to the PCI. Here, a cold plasma finite element model (CPFEM) [4] is used to predict propagation through the scrape-off layer. The result of the CPFEM model is connected to AORSA by creating an artificial Gaussian antenna on the last closed flux surface. PCI shows best results for waves with small vertical wavenumbers k z . Modeling the helicon waves for several past DIII-D experiments shows that k z is minimized if the intersection of the helicon and the PCI laser beams occurs in the midplane. For such an optimized scenario the predicted signal level is two orders of magnitude larger than the background density fluctuations arising from broadband turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Traceability of Surface Longwave Irradiance Measurements to SI Using the IRIS Radiometers

The traceability of the World Infrared Standard Group of Pyrgeometers (WISG) was established through the comparison to several independently calibrated radiometers (Infrared Integrating Sphere Radiometer (IRIS), Absolute Cavity Pyrgeometer (ACP), Atmospheric Emittance Radiance Interferometer (AERI)). The traceability of the longwave irradiance measurements to SI was validated by a comparison of two independently characterized blackbody cavities.

ACR↗

Acoustoelastic characterization of plates using zero group velocity Lamb modes

Acoustoelasticity, a characteristic of material anharmonicity, gives rise to a link between wave propagation velocity and the stress state in materials. Ultrasonic techniques to monitor this coupling, particularly with high sensitivity and in a noncontact manner, can have widespread application both in the quantification of applied and residual stress and in the characterization of nonlinear material behavior through measurement of higher order elastic constants. Here, we use a laser ultrasonic technique to excite and detect zero group velocity (ZGV) Lamb wave resonances in aluminum plates under uniaxial loading. A laser line source is used to excite these resonances at different orientations with respect to the applied load, and the signals are detected using an interferometer. The effects of stress and source orientation on ZGV resonance frequencies are validated using the theory of acoustoelastic Lamb wave propagation. In addition, a model-based inversion technique is used to extract Murnaghan's third-order elastic constants from measurements of the stress dependence of the first two ZGV modes generated parallel and perpendicular to the applied load. Laser generation and detection of ZGV resonances is shown to be an effective and powerful approach for the noncontact and nondestructive acoustoelastic characterization of elastic waveguides.

36 MATERIALS SCIENCE↗

Internal measurements of electromagnetic geodesic acoustic mode (GAM) in EAST plasmas

Velocity, density, and magnetic fluctuations of the geodesic acoustic mode (GAM) have been measured using the Doppler backscattering system, Faraday-effect polarimeter-interferometer, and external pick-up coils in the Experimental Advanced Superconducting Tokamak. Simultaneous measurements of density and velocity fluctuations at the midplane and top of plasmas demonstrate that m = 1 density fluctuations are quantitatively balanced by the compression of perpendicular flow fluctuations. Furthermore, internal magnetic fluctuations associated with GAM have now been directly measured by laser-based Faraday-effect polarimetry for the first time. Line-averaged magnetic fluctuations (up to 16 Gauss, B̃¯R,GAMBT∼0.066%) are significantly larger than those extrapolated from edge coils (a few Gauss) and that magnetic fluctuations increase with β. The observed discrepancy between finite β theory and experimental data indicates the need for further theoretical investigations.

Physics↗

Simultaneous measurement of surface velocity and plasma density with interferometric velocimetry

The apparent velocity measured by an interferometric surface velocimeter is a function of both the surface velocity and the time derivative of the refractive index along the measurement path. We employed this dual sensitivity to simultaneously measure km/s surface velocities and 10 18 cm -3 average plasma densities with combined VISAR (velocity interferometer system for any reflector) and PDV (photonic Doppler velocimetry) measurements in experiments performed on the Z Pulsed Power Facility. We detail the governing equations, associated assumptions, and analysis specifics and show that the surface velocity can be extracted without knowledge of the specific plasma density profile.

47 OTHER INSTRUMENTATION↗

Validation of predictive performance models for supersonic gas-jet nozzles at the Laboratory for Laser Energetics

We present results characterizing the neutral-density distributions produced by the supersonic nozzles used in experiments on the OMEGA-60 and OMEGA-EP laser systems at the University of Rochester’s Laboratory for Laser Energetics (LLE). Axisymmetric Fluent® simulations using LLE nozzle specifications capture the viscous effects, gas expansion, and shock waves that complicate flow predictions for offsets above the nozzle exit. Here, these simulations show good agreement with neutral-density measurements obtained using a four-wave shearing interferometer. An analytical form is given for the plateau length. Fits to simulation data for boundary layer thickness, mean plateau density, and density ramps are given as functions of nozzle offset and nozzle backing pressure for a number of nozzles and gases.

47 OTHER INSTRUMENTATION↗

Shock compression of crystalline TeO 2 to the high-pressure fluid regime: Insights from ab initio molecular dynamics simulations

The shock response of fully-dense and porous crystalline tellurium dioxide (TeO 2 ⁠) to the high-pressure and high-temperature fluid regime was investigated within the framework of density functional theory with Mermin’s generalization to finite temperatures. The principal and porous shock Hugoniot curves were predicted from canonical ab initio molecular dynamics (AIMD) simulations, with the phase space sampled along isotherms up to 80 000 K, for densities ranging from ρ = 3 to 17 g/cm 3 . The polymorphs investigated are α-TeO 2 paratellurite (⁠P4 1 2 1 2), TeO 2 cotunnite (⁠Pnma⁠), and TeO 2 post-cotunnite (⁠P2 1 /m⁠). Based on the discontinuity found in the calculated U s – u p slope of TeO 2 post-cotunnite at a shock velocity of U s ≃ 8.35km/s and a particle velocity of u p ≃ 3.64 km/s, the shock melting temperature and pressure are predicted to be ≃ 6500 K and ≃ 170 GPa. Results from the AIMD simulations are in line with the static compression data of TeO 2 paratellurite and cotunnite, and with the recent shock Hugoniot data for single-crystal α- TeO 2 for pressures up to 85 GPa, obtained using the inclined-mirror method and the velocity interferometer system for any reflector combined with powder gun and two-stage light-gas gun.

74 ATOMIC AND MOLECULAR PHYSICS↗

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION↗

Ferroelectricity of wurtzite Al 1−x Hf x N heterovalent alloys

Thin films of aluminum hafnium nitride (Al1−xHfxN) were synthesized via reactive magnetron sputtering for Hf contents up to x = 0.13. X-ray diffraction showed a single c-axis oriented wurtzite phase for all films. Hard x-ray photoelectron spectroscopy demonstrated homogeneous Al:Hf distribution through the thin films and confirmed their insulating character. A collection of complementary tests showed unambiguous polarization inversion, and thus ferroelectricity in multiple samples. Current density vs electric field hysteresis measurements showed distinct ferroelectric switching current peaks, the piezoelectric coefficient d 33,f,meas measured using a double beam laser interferometer (DBLI) showed a reversal in sign with similar magnitude, and anisotropic wet etching confirmed field-induced polarization inversion. This demonstrates the possibility of using tetravalent–and not just trivalent–alloying elements to enable ferroelectricity in AlN-based thin films, highlighting the compositional flexibility of ferroelectricity in wurtzites and greatly expanding the chemistries that can be considered for future devices.

36 MATERIALS SCIENCE↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗

Shock propagation in aerogel and TPP foams for inertial fusion energy target design

Achieving practical inertial fusion energy (IFE) requires the development of target designs with well-characterized microstructure and compression response. We measured shock dynamics in low-density (17.5–500 mg/cm 3 ) aerogel and two-photon polymerization (TPP) foams using x-ray phase contrast imaging (XPCI) methods and the Velocity Interferometer System for Any Reflector. By analyzing shock front evolution, we examined how target type and density influence shock propagation and energy dissipation. Talbot-XPCI shows that aerogels support a smooth, bowed shock front due to their homogeneous nanometer-scale pore network. In contrast, TPP foams exhibit irregular, stepwise propagation driven by interactions with their periodic micrometer-scale lattice. Shock velocity follows a power-law relation: aerogels deviate from classical ρ −1/2 scaling due to pore-collapse dissipation, while TPP foams follow the trend with larger uncertainties from density variations. Comparisons with xRAGE simulations reveal systematic underestimation of shock speeds. These results provide the first experimental constraints on shock propagation in TPP foams over a wide density range and highlight the influence of internal structure on anisotropic shock behavior. Our findings support improved benchmarking of EOS and hydrodynamic models and inform the design of foam architectures that promote implosion symmetry in IFE capsules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous hard x-ray Talbot phase and dark-field imaging in laser experiments at XFEL facilities

X-ray Free Electron Laser (XFEL) facilities offer unprecedented opportunities to advance instrumentation for studying matter under extreme conditions. In this study, we harnessed the enhanced x-ray capabilities of XFELs to demonstrate dark field imaging in laser-driven experiments at XFEL facilities. Utilizing a Talbot x-ray interferometer, we simultaneously captured transmission, dark-field, and differential phase contrast radiographs of laser-driven metallic foils. Our work showcases the feasibility of single-shot grating-based Talbot x-ray dark-field imaging in pump-probe experiments at XFEL facilities, opening doors to a wide range of hard x-ray imaging applications in material science and high-energy density physics.

Bouffetier, V. [Helmholtz-Zentrum Dresden-Rossendo↗

Fiber coupled laser ultrasound system using a single mode hollow core fiber for excitation laser: Theory and demonstration for on-machine thickness gauging

Laser ultrasound (LU) is a technique that uses a pump laser and a probe laser to optically generate and detect elastic waves in a material. Despite its advantages over traditional contact transducer-based ultrasound, industrial adoption has been limited by complex optical setups and the inability of multi-mode fibers to deliver a stable Gaussian profile for the pump laser. Here, we report a fully fiber-coupled thermoelastic LU system that uses an anti-resonant hollow-core single-mode fiber to deliver 1 mJ nanosecond pulses of 1064 nm light, while preserving the fundamental Gaussian mode (pump laser). When combined with a fiber-coupled interferometer (probe laser), a small, flexible, and environmentally robust sensor capable of optically generating and detecting high frequency broadband ultrasound is realized. We demonstrate such an LU system implemented in situ on a four-axis precision lathe. High-resolution thickness gauging is performed, before and after precision cutting, by exciting and measuring a zero-group velocity guided wave mode. The measurements are verified with ex-situ traceable coordinate measuring machine data. Mean absolute deviations of 0.1%, of nominal thickness, before cutting, and 0.2% and 0.3%, after stepped and tapered cuts, respectively, are reported. A theoretical background for thermoelastic ultrasound generation in an elastic waveguide is also presented. Attention is given to the effect of the pump laser profile on wave generation to elucidate the importance of using single-mode laser light. The fiber-coupled system demonstrated is well-suited for use in scientific and engineering sensing applications and facilitates the adoption of LU for industrial non-destructive testing.

Engineering↗

Chromatic dispersion effects in ultra-low coherence interferometry

We consider the properties of an interference signal shift from zero-path-difference position in the presence of an uncompensated dispersive layer in one of the interferometer arms. It is experimentally shown that in using an ultra-low coherence light source, the formation of the interference signal is also determined by the group velocity dispersion, which results in a nonlinear dependence of the position of the interference signal on the geometrical thickness of the dispersive layer. The discrepancy in the dispersive layer and compensator refractive indices in the third decimal place is experimentally shown to lead to an interference signal shift that is an order of magnitude greater than the pulse width. (interferometry)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser adaptive holographic hydroacoustic intensimeter

A new type of a vector hydrophone, a laser adaptive hydroacoustic intensimeter, is investigated. Two identical, spatially separated coil-type sensors are used as a primary receiver of the acoustic signal. The signals received at the sensor output are phase demodulated in a two-channel adaptive holographic interferometer based on two dynamic holograms multiplexed in a CdTe photorefractive crystal. Using a laser intensimeter, the acoustic field formed in a limited volume is studied. The performance characteristics of the intensimeter are determined experimentally; its threshold sensitivity, according to the acoustic field intensity, constitutes 0.1 × 10{sup −13} W m{sup −2}. (laser applications)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum interferometry and pathway selectivity in the nonlinear response of photosynthetic excitons

We propose a time–frequency resolved spectroscopic technique which employs nonlinear interferometers to study exciton–exciton scattering in molecular aggregates. A higher degree of control over the contributing Liouville pathways is obtained as compared to classical light. We show how the nonlinear response can be isolated from the orders-of-magnitude stronger linear background by either phase matching or polarization filtering. Both arise due to averaging the signal over a large number of noninteracting, randomly oriented molecules. We apply our technique to the Frenkel exciton model which excludes charge separation for the photosystem II reaction center. We show how the sum of the entangled photon frequencies can be used to select two-exciton resonances, while their delay times reveal the single-exciton levels involved in the optical process.

Science & Technology - Other Topics↗

Fabrication, Assembly, and Metrology of the Neutron Imaging Pinhole

The neutron imaging pinhole is a complex aperture that is designed to have its image plane at the center of a laser fusion capsule implosion. The aperture’s high-Z materials of tungsten and gold block the neutrons so that only the neutrons passing through the machined apertures make it to the image plane and detector. The pinhole assembly consists of 11 layers of gold in between two layers of tungsten and gold. These 64 triangular pinholes and six penumbra apertures provide a matrix image that can be reconstructed to image complex deuterium-tritium neutron burn details in laser fusion capsules. The gold layers were diamond turned flat before the profiles were cut into their faces. Four of the layers were profiled with penumbral profile arrays that tapered from a radius of 250 to 150 µm. Three gold layers were just diamond turned to wedges to set the tilt of the whole aperture. Three gold layers were profiled on both sides with triangle groove arrays that consist of eight equilateral triangles with the depth of 200 to 15 µm over the 200-mm length, with a tolerance of 2 µm. Custom software programming routines were written using Labview to move the diamond-turning profiler through the required X-Y-Z movements to cut the penumbral and grooved profiles of the pinhole into the varying tilted arrays of features. The software is optimized to push the profile of the whole part into the face while eliminating any unneeded passes that do not cut any material. Each layer was thoroughly inspected on both sides using an optical coordinate measuring machine and white-light interferometer to validate each of the profiles. The pinhole assembly was inspected on a rotary stage so that both ends of the assembly can be inspected and presented in a single point cloud. The process of machining, programming, assembly, and inspection of the neutron imaging pinhole is covered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗