Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flash”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Operational Evaluation of NASA SPoRT Lightning Safety Applications for Impact Based Decision Support Services

The NWS Office in Huntsville is tasked with monitoring and predicting the threat for lightning within its County Warning Area. These impact-based decision support services (IDSS) are provided routinely for aviation operations, irregularly for large-scale, outdoor events, and can have varying safety requirements, such as proximity to location and duration. Lightning monitoring and prediction can require the rapid synthesis of a plethora of data, so products that make this process more efficient and effective are sought by the operational community. The Huntsville NWS Office benefits from close collaboration with the NASA SPoRT Center, which is developing several products to address these operational challenges in concentrated R2O/O2R efforts. One example of this is the StopLight product, which uses Geostationary Lightning Mapper (GLM) flash extent density (FED) to provide an easy-to-interpret visual aid of lightning occurring within the last 30 minutes. The StopLight product shows both the age and location of the last lightning flash within each GLM pixel, which can be particularly useful for IDSS with determining when to resume activities or operations that have been shut down due to lightning. This presentation highlights results of collaboration between NASA SPoRT and NWS Huntsville, including testing of the Stoplight product, and additional experimental products in development. A brief summary of the lightning products are provided while the main focus will discuss product evaluation and forecaster perspective during real-time weather watch activities to support aviation operations and events where IDSS was necessary.

Kristopher White↗

Comparing Cumulative Flight Thermal Fatigue to Ground Test Results for Memory Components on the Mars Curiosity Rover

This paper explores the methods used to examine Mars Curiosity Rover’s flight temperature data in relation to the Package Qualification and Verification (PQV) accelerated thermal cycle life test data in response to flight anomalies. The redundant Rover Compute Element (RCE-A, B) has experienced an inability to mount the flash memory several times. The leading cause of these anomalies is likely the loss of electrical connectivity, which is theorized to be due to cracks on the memory component solder joints by thermal cycle fatigue. To investigate this theory, the number of thermal cycles accumulated in flight was compared to PQV accelerated thermal cycle life test data. The goal of this study was to inform mission operations of the risk associated with thermal cycling damage on the RCE. However, since the RCE-B does not have continuous temperature data from the Platinum Resistance Thermometer (PRT) closest to the flash memory, a model was made to correlate continuous data from two other nearby sensors on the RCE-B to the noncontiguous sensor. Using the Rainflow Counting Algorithm, the reconstituted data was converted into the number of equivalent thermal cycles. The Coffin-Manson Equation was used to compare flight thermal cycles to the PQV test. The accelerated life test showed cracking on the memory component solder joints after 500 cycles of 80°C temperature excursions. This study found that the RCE-A and RCE-B have undergone an equivalent of 144 and 430 cycles of 80°C temperature excursions during flight, respectively.

Bell, Charles↗

Hunting Energetic Radiation from Thunderstorms

The true nature and mechanisms of terrestrial gamma-ray flashes (TGFs) have remained mysterious since their discovery in the 1990s. Despite decades of detections, their violent origins and irregularity make them particularly difficult to observe directly. Combined with the wide range of measured characteristics, this has kept the details of these energetic events in the dark. The recent ALOFT (Airborne Lightning Observatory for FEGS and TGFs) campaign has undertaken the challenge of hunting these elusive flashes from an airborne platform. This was performed by the NASA ER-2 aircraft in July 2023 equipped with a host of meteorological, electric field, and gamma-ray instruments to study intense tropical thunderstorms and their connection to gamma-ray production. Here we present on the campaign's success alongside some of its exciting preliminary results.

Lightning↗

GOES-16 GLM Observations for National Climate Assessments

The heating of air by a lightning discharge, followed by rapid cooling, leads to the production of lightning nitrogen oxides (“LNO x ” for brevity, where NO x = NO + NO 2 ). The LNO x are important trace gases because they control the concentration of the greenhouse gas ozone (O 3 ) and the highly reactive hydroxyl radicals (OH). In fact, LNO x are the most important source of NO x in the upper troposphere at tropical and subtropical latitudes, and climate is most sensitive to O 3 in the upper troposphere. Since lightning indirectly influences the Earth's climate, it is a key variable to monitor in National Climate Assessment (NCA) studies. In this work, GOES-16 Geostationary Lightning Mapper (GLM) flash counts and flash optical properties (i.e., optical energy, optical area, …) that are linked to LNO x production are examined in detail for the continental United States analysis region, and are compared with ground-based National Lightning Detection Network (NLDN) observations.

Lightning↗

3D Lightning Geolocation With the CubeSpark Constellation

The new CubeSpark mission concept is being developed as a constellation of up to six satellites for high-resolution 3D lightning mapping. Each satellite in low-Earth orbit (LEO) will use optical and radio frequency (RF) sensors to geolocate individual sources from lightning flashes. The purpose of this study is to evaluate the potential accuracies and feasibilities of RF-based geolocation methods. This is done using a robust simulation framework to accurately depict the ionosphere’s effect on propagating RF signals, using their arrival times at each station to reconstruct source locations. We identified the primary sources of error as geometric, ionospheric, and instrumental. These are each analyzed to determine their quantitative effect on geolocation uncertainty. CubeSpark’s science objectives include mapping thundercloud charge regions and even individual flash channel structure for applications across a wide range of fields from climatology to hydrology. These applications require geolocation accuracy better than 1-2 km in each dimension, thus special care must be taken to optimize constellation design, minimize the main sources of error, and maximize CubeSpark’s potential. The algorithms developed in this study show promising results, with large regions having both horizontal and vertical uncertainties less than 1 km. After the removal of the Lightning Imaging Sensor from the International Space Station, an observational gap has been left for lightning observers from LEO. It therefore becomes increasingly vital to evaluate and improve on the current state of lightning mapping to prepare for the next generation of 3D lightning geolocation.

lightning↗

Thermal Inspection of Low Emissivity Surfaces Using a Pulsed Light Emitting Diodes (PLED) Heat Source

Thermal inspections of a structure typically utilize a flash or quartz lamp heat source located on the same side of an infrared camera. The heat source provides light energy for heating while the infrared camera measures the surface transient temperature response. The inspection can be difficult for low emissivity surfaces for several reasons. First, the high intensity light can reflect off the surface and cause “burn-in” to the camera’s detector. The “burn-in” can take time for the sensors to recover and potentially damage the detector. Secondly, the heat source after pulsing, has a transient cool down component. The cool down component can be reflected and therefore superimposed over the structure’s thermal response which can cause an error (false defect indications) in the inspection. Lastly, the heat source is spectrally broad and therefore while heating, infrared components of the heat source can produce non-uniformity in the measured temperature field. Typically for the inspection of reflective surfaces, paint or other emissivity enhancing coatings are applied before inspection. In this paper, a pulsed light emitting diodes (PLED) heat source is used. The PLED heat source is spectrally narrow, contained within the visible band, and therefore not detectable by the infrared camera. The PLED heat source is configured to reduce any transient cool down components that could produce false defect indications. The PLED thermal inspections are compared to commercially available flash thermography inspections on unpainted aluminum samples with simulated corrosion and additively manufactured Ti-6AL-4V metal specimens.

thermal nondestructive evaluation↗

Thermal Inspection of Low Emissivity Surfaces Using a Pulsed Light Emitting Diodes (PLED) Heat Source

Thermal inspections of a structure typically utilize a flash or quartz lamp heat source located on the same side of an infrared camera. The heat source provides light energy for heating while the infrared camera measures the surface transient temperature response. The inspection can be difficult for low emissivity surfaces for several reasons. First, the high intensity light can reflect off the surface and cause “burn-in” to the camera’s detector. The “burn-in” can take time for the sensors to recover and potentially damage the detector. Secondly, the heat source after pulsing, has a transient cool down component. The cool down component can be reflected and therefore superimposed over the structure’s thermal response which can cause an error (false defect indications) in the inspection. Lastly, the heat source is spectrally broad and therefore while heating, infrared components of the heat source can produce non-uniformity in the measured temperature field. Typically for the inspection of reflective surfaces, paint or other emissivity enhancing coatings are applied before inspection. In this paper, a pulsed light emitting diodes (PLED) heat source is used. The PLED heat source is spectrally narrow, contained within the visible band, and therefore not detectable by the infrared camera. The PLED heat source is configured to reduce any transient cool down components that could produce false defect indications. The PLED thermal inspections are compared to commercially available flash thermography inspections on unpainted aluminum samples with simulated corrosion and additively manufactured Ti-6AL-4V metal specimens.

thermal nondestructive evaluation↗

3D Lightning Geolocation with the CubeSpark Constellation

The new CubeSpark mission concept is being developed as a constellation of up to six satellites for high-resolution 3D lightning mapping. Each satellite in low-Earth orbit (LEO) will use optical and radio frequency (RF) sensors to geolocate individual sources from lightning flashes. The purpose of this study is to evaluate the potential accuracies and feasibilities of RF-based geolocation methods. This is done using a robust simulation framework to accurately depict the ionosphere’s effect on propagating RF signals, using their arrival times at each station to reconstruct source locations. We identified the primary sources of error as geometric, ionospheric, and instrumental. These are each analyzed to determine their quantitative effect on geolocation uncertainty. CubeSpark’s science objectives include mapping thundercloud charge regions and even individual flash channel structure for applications across a wide range of fields from climatology to hydrology. These applications require geolocation accuracy better than 1-2 km in each dimension, thus special care must be taken to optimize constellation design, minimize the main sources of error, and maximize CubeSpark’s potential. The algorithms developed in this study show promising results, with large regions having both horizontal and vertical uncertainties less than 1 km. After the removal of the Lightning Imaging Sensor from the International Space Station, an observational gap has been left for lightning observers from LEO. It therefore becomes increasingly vital to evaluate and improve on the current state of lightning mapping to prepare for the next generation of 3D lightning geolocation.

lightning↗

Simulated Feasibility of 3D Lightning Mapping from Space

In addition to the awe it inspires, lightning can illuminate the microphysical processes hidden away within deep convection. The current generation of space-based lightning mapping uses mostly 2D optical imaging to connect overall flash characteristics to their parent storm dynamics, but are missing a dimension’s worth of information. With lightning now classified as an essential climate variable, future spaceborne mappers will need improved capabilities to take advantage of the 3D structure of lightning flashes to support meteorological and climate modeling. We report here on a study of the feasibility of implementing a radio frequency (RF)–based network of satellites for 3D lightning mapping in high resolution from low Earth orbit (LEO). Lightning sources are simulated using existing tools of the Lightning Mapping Array (LMA), modified for orbital detection, and spatially reconstructed using a Levenberg-Marquardt geolocation algorithm to assess sources of uncertainty in these solutions. We analyze the benefits and limitations of this approach compared to existing orbital and ground-based methods. Results of this study show that lightning can be mapped in 3D with a vertical location accuracy better than 2 km using as few as five satellites in LEO capable of measuring the time-of-arrival of impulsive RF signals in the very high frequency (VHF) band. The consequence of this study is that high-resolution, spaceborne 3D mapping of lightning is achievable across most of the globe, having crucial implications for our understanding of not only lightning, but also severe weather development, climate science, and more.

CubeSpark↗

Oblique Eccentric Gaze Holding Evokes Larger Horizontal than Vertical Rebound Nystagmus

Rebound nystagmus (RN) has been used to probe the adaptation mechanisms of the gaze holding system. This type of nystagmus is invoked upon returning to central gaze after prolonged fixation at an eccentric point and it is thought to reflect a set-point adaptation of the neural integrator circuit. Previous studies have only observed horizontal RN after horizontal eccentric gaze holding, reflecting adaptation of the horizontal neural integrator. The current study seeks to elucidate how eccentric gaze at oblique target locations, where there are equal horizontal and vertical components, affects the characteristics of the resulting RN. For a given trial, subjects were instructed to fixate a central flashing target for 5 seconds, then fixate an eccentric continuous target for 30 seconds at one of six possible locations (4 oblique and 2 horizontal targets), and finally fixate centrally at a flashing target for 15 seconds where RN is assessed. Binocular eye-tracking data were collected at 250 Hz. Slow-phase velocity (SPV) or the slow drift part of the nystagmus was used to quantify the magnitude of RN. Subjects showed elevated SPV in the horizontal component (2.3 deg/s), but less in the vertical component (1.4 deg/s) after oblique eccentric gaze holding, reflecting an oblique RN. The smaller vertical RN may reflect a different behavior of the horizontal and vertical neural integrators which are anatomically separated. Under the current paradigm, oblique gaze holding would appear to have a smaller effect on adaptation of the vertical integrator than in the horizontal integrator. Further investigation is needed to establish the reference frame of this distinction between the horizontal and vertical integrator circuits.

gaze holding↗

The Next Generation of Lightning Mapping

With the removal of the Lightning Imaging Sensor from the International Space Station, a gap has opened in lightning observation from low-Earth orbit. The CubeSpark mission concept aims to fill this role using a constellation of satellites with radio frequency (RF) sensors and bi-spectral optical imagers to observe lightning flashes more completely and with better resolution than is currently possible from space. In this study, we assess the feasibility of multiple methods of not only mapping lightning locations, but also inferring 3D flash and charge structures. This is done primarily by simulating lightning emissions in the very high frequency (VHF) band, modeling their propagation to orbital sensors, and reconstructing their locations using time-of-arrival (TOA) minimization algorithms. Constellation shape, number, and atmospheric conditions are varied in order to quantify the three main sources of geolocation error: geometric, ionospheric, and instrumental effects. The promising results presented here demonstrate 3D resolution better than 1-2 km in many cases, enabling new applications in meteorology and climate sciences.

CubeSpark↗

Diurnal Cycles of Intense Thunderstorms As Seen By Satellites

Spaceborne sensors cannot directly measure aspects of severe weather occurring at ground-level. Tools from Geostationary Earth Orbit (GEO) and Low Earth Orbit (LEO) can be related to storm intensity and likelihood of severe weather. Visible and Infrared (GEO and LEO) measure cloud-top properties and horizontal structure. Some properties have empirical correlations with severe weather occurrence. Precipitation Radar (LEO) measures vertical profile of reflectivity related to particle size and concentration, but attenuates (2.2-cm and shorter wavelengths) well above the surface in intense thunderstorms. Lightning mappers (GEO and LEO) measure lightning flash rates and flash properties, which relate to updraft properties including size and vigor. SAR and optical sensors can detect damage paths on the surface after a storm has passed. (Depends on the vegetation type and maturity.)

Daniel J Cecil↗

Dependence of Lightning Cloud-Top Optical Emissions on Channel Characteristics Using Boltzmann Radiative Transfer Modeling

With an estimated global flash rate of 46 lightning per second, a significant amount of lightning nitrogen oxides (LNOx) are produced within the climate system. In turn, LNOx affect the concentrations of ozone (O 3 , an important greenhouse gas) as well as the very reactive hydroxyl radicals (OH, that affect all greenhouse gases). Thus, space-based estimation of LNOx is highly sought [Koshak 2017; Koshak et al. (2015)]. Total lightning channel length, L , is a proxy for the total flash energy (and hence LNOx production). Geostationary lightning mappers provide cloud-top 2D views of the diffuse (i.e., blurry) optical images of lightning, thereby making it difficult to determine L (and other channel features). Transient Boltzmann radiative transfer modeling is applied here to investigate the dependence of the spatio-temporal pattern of cloud-top lightning optical emissions on L and other channel characteristics (e.g., orientation, propagation direction, amplitude, location, ...).

William J Koshak↗

New Whole-House Solutions Case Study: Exterior Rigid Foam Insulation at the Edge of a Slab Foundation, Fresno, California

Exterior rigid foam insulation at the edge of the slab foundation was a unique feature for this low-load, unoccupied test house in a hot-dry climate and may be more appropriate for climates with higher heating loads. U.S. Department of Energy Building America research team IBACOS worked with National Housing Quality Award winner Wathen-Castanos Hybrid Homes, Inc., to assess the performance of this feature in a single-family detached ranch house with three bedrooms and two full bathrooms constructed on a slab-on-grade foundation in Fresno, California. One challenge during installation of the system was the attachment of the butyl flashing to the open framing. To solve this constructability issue, the team added a nailer to the base of the wall to properly attach and lap the flashing. In this strategy, R-7.5, 1.5-in.-thick extruded polystyrene was installed on the exterior of the slab for a modeled savings of 4,500 Btu/h on the heating load.

Building America↗

Higher Order Modes for Beam Diagnostics in Third Harmonic 3.9 GHz Accelerating Module

An international team is currently investigating the best way to use Higher Order Modes (HOM) for beam diagnostics in 3.9 GHz cavities. HOMs are excited by charged particles when passing through an accelerating structure. Third harmonic cavities working at 3.9 GHz have been installed in FLASH to linearize the bunch energy profile. A proof-of-principle of using HOMs for beam monitoring has been made at FLASH in the TESLA 1.3 GHz cavities. Since the wakefields generated in the 3.9 GHz cavities are significantly larger, their impact on the beam should be carefully minimized. Therefore our target is to monitor HOMs and minimize them by aligning the beam on the cavity axis. The difficulty is that, in comparison to the 1.3 GHz cavities, the HOM-spectrum is dense, making it difficult to identify individual modes. Also, most modes propagate through the whole cryo-module containing several cavities, making it difficult to measure local beam properties. In this paper the options for the HOM-based beam position monitors are discussed.

Baboi, N.↗

Energy efficient solvent regeneration process for carbon dioxide capture

A process for removing carbon dioxide from a carbon dioxide-loaded solvent uses two stages of flash apparatus. Carbon dioxide is flashed from the solvent at a higher temperature and pressure in the first stage, and a lower temperature and pressure in the second stage, and is fed to a multi-stage compression train for high pressure liquefaction. Because some of the carbon dioxide fed to the compression train is already under pressure, less energy is required to further compress the carbon dioxide to a liquid state, compared to conventional processes.

03 NATURAL GAS↗

Lessons Learned from a Laser Injury Event - Limitations of Skill-Of-The-Craft

A technician at INL received 2nd degree burns to the middle and ring fingers of his left hand while performing a preventive maintenance (PM) procedure on a Class 4 industrial laser on August 30, 2011. The task required placement of a “target” in the beam path to verify mirror alignment. The technician, believing the laser was in a safe mode, reached into the beam pathway to place the target, saw a flash and immediately withdrew his hand. Three INL technicians were assigned to perform a 2000 hour run time PM on a laser. A pre-job briefing was held August 29, 2011 by the acting foreman and the technicians started the PM. They had completed 25 steps in Section I of the work order by the end of the day. The laser systems were placed under LO/TO and the internal optics were cleaned and/or replaced. The LO/TO was released and the next morning, August 30, 2011, the technicians prepared to take a diagnostic shot inside the internal optics. The laser was powered up at the HMI, and the person in charge (PIC) selected the “Mirror Alignment” program from the human machine interface (HMI) screen, enabled the pendent and pressed the “Cycle Start” button. The technicians believed the laser was in “simmer” mode at this point and that no beam was being generated out of the resonator. A beam was being generated in the “Mirror Alignment” program when the “Cycle Start” button was pressed. They decided to check the #4 aperture target and see if they were aligned at that location. One of the technicians reach to place the target at the end of the Z box and a “Flash” occurred. The technician immediately retracted his hand with the target. The PIC turned off the high voltage (HV) at the pendent. The foreman and supervisor were informed of the incident and the injured technician was escorted to an onsite medical facility. The nurse evaluated the injury and sent the technician to a physician for further evaluation. A physician examined the technician’s hand. The technician’s left middle and ring fingers received 2nd degree burns to both finger tips. A prescription burn ointment and bandage was applied. The employee was returned to work with no restrictions.

99 GENERAL AND MISCELLANEOUS↗

Techno-Economic Assessment of Geothermal Power Plants Hybridized with Solar Heat and Thermal Storage

Geothermal power plants may experience a decrease in power output over time due to a reduction in either mass flow rate, temperature or pressure of the resource. A recent study quantified the temperature drawdown of U.S. double-flash geothermal power plants at 0.8% per year. Hybridizing existing geothermal plants with other renewable power sources to exploit the unused capacity of the geothermal power block has become an area of increasing interest. For instance, a geothermal power plant may be retrofitted with heat from a concentrating solar field. In addition, geothermal may be integrated with solar in a new-build site with the aim of combining the benefits of both technologies -- i.e. the baseload generation of geothermal, plus the relatively high efficiency of concentrating solar power. In this article, we give an overview of hybrid geothermal-solar projects undertaken at the National Renewable Energy Laboratory in collaboration with various partners. We investigate the retrofit of double-flash and binary geothermal plants with solar heat. Off-design models are developed and validated with operational data. Annual simulations evaluate the hourly performance, the benefits of thermal storage, and are used to calculate economic metrics. Finally, we discuss the implications of integrating solar and geothermal in a new greenfield site.

15 GEOTHERMAL ENERGY↗