Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drawing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

SU-F-P-53: RadShield: Semi-Automated Shielding Design for CT Using NCRP 147 and Isodose Curves

Purpose: Computed tomography (CT) exam rooms are shielded more quickly and accurately compared to manual calculations using RadShield, a semi-automated diagnostic shielding software package. Last year, we presented RadShield’s approach to shielding radiographic and fluoroscopic rooms calculating air kerma rate and barrier thickness at many points on the floor plan and reporting the maximum values for each barrier. RadShield has now been expanded to include CT shielding design using not only NCRP 147 methodology but also by overlaying vendor provided isodose curves onto the floor plan. Methods: The floor plan image is imported onto the RadShield workspace to serve as a template for drawing barriers, occupied regions and CT locations. SubGUIs are used to set design goals, occupancy factors, workload, and overlay isodose curve files. CTDI and DLP methods are solved following NCRP 147. RadShield’s isodose curve method employs radial scanning to extract data point sets to fit kerma to a generalized power law equation of the form K(r) = ar^b. RadShield’s semi-automated shielding recommendations were compared against a board certified medical physicist’s design using dose length product (DLP) and isodose curves. Results: The percentage error found between the physicist’s manual calculation and RadShield’s semi-automated calculation of lead barrier thickness was 3.42% and 21.17% for the DLP and isodose curve methods, respectively. The medical physicist’s selection of calculation points for recommending lead thickness was roughly the same as those found by RadShield for the DLP method but differed greatly using the isodose method. Conclusion: RadShield improves accuracy in calculating air-kerma rate and barrier thickness over manual calculations using isodose curves. Isodose curves were less intuitive and more prone to error for the physicist than inverse square methods. RadShield can now perform shielding design calculations for general scattering bodies for which isodose curves are provided.

60 APPLIED LIFE SCIENCES↗

SU-F-J-132: Evaluation of CTV-To-PTV Expansion for Whole Breast Radiotherapy

Purpose: The current standard CTV-to-PTV expansion for whole breast radiotherapy (WBRT) is 7mm, as recommended by RTOG-1005.This expansion is derived from the uncertainty due to patient positioning (±5mm) and respiratory motion (±5mm). We evaluated the expansion needed for respiratory motion uncertainty using 4DCT. After determining the appropriate expansion margins, RT plans were generated to evaluate the reduction in heart and lung dose. Methods: 4DCT images were acquired during treatment simulation and retrospectively analyzed for 34 WBRT patients. Breast CTVs were contoured on the maximum inhale and exhale phase. Breast CTV displacement was measured in the L-R, A-P, and SUP-INF directions using rigid registration between phase images. Averaging over the 34 patients, we determined the margin due to respiratory motion. Plans were generated for 10 left-sided cases comparing the new expansion with the 7mm PTV expansion. Results: The results for respiratory motion uncertainty are shown in Table 1. Drawing on previous work by White et al at Princess Margaret Hospital (1) (see supporting document for reference) which studied the uncertainty due to patient positioning, we concluded that, in total, a 5mm expansion was sufficient. The results for our suggested PTV margin are shown in Table 2, combining the patient positioning results from White et al with our respiratory motion results. The planning results demonstrating the heart and lung dose differences in the 5mm CTV-to-PTV expanded plan compared to the 7mm plan are shown in Table 3. Conclusion: Our work evaluating the expansion needed for respiratory motion along with previous work evaluating the expansion needed for setup uncertainty shows that a CTV-to-PTV expansion of 5mm is acceptable and conservative. By reducing the PTV expansion, significant dose reduction to the heart and lung are achievable.

60 APPLIED LIFE SCIENCES↗

SU-F-T-242: A Method for Collision Avoidance in External Beam Radiation Therapy

Purpose: We proposed a method for collision avoidance (CA) in external beam radiation therapy (EBRT). The method encompasses the analysis of all positions of the moving components of the beam delivery system such as the treatment table and gantry, including patient specific information obtained from the CT images. This method eliminates the need for time-consuming dry-runs prior to the actual treatments. Methods: The QA procedure for EBRT requires that the collision should be checked prior to treatment. We developed a system capable of a rigorous computer simulation of all moving components including positions of the couch and gantry during the delivery, position of the patients, and imaging equipment. By running this treatment simulation it is possible to quantify and graphically represent all positions and corresponding trajectories of all points of the moving parts during the treatment delivery. The development of the workflow for implementation of the CA includes several steps: a) derivation of combined dynamic equation of motion of the EBRT delivery systems, b) developing the simulation model capable of drawing the motion trajectories of the specific points, c) developing the interface between the model and the treatment plan parameters such as couch and gantry parameters for each field. Results: The patient CT images were registered to the treatment couch so the patient dimensions were included into the simulation. The treatment field parameters were structured in the xml-file which was used as the input into the dynamic equations. The trajectories of the moving components were plotted on the same graph using the dynamic equations. If the trajectories intersect that was the signal that collision exists. Conclusion: This CA method was proved to be effective in the simulation of treatment delivery. The proper implementation of this system can potentially improve the QA program and increase the efficacy in the clinical setup.

60 APPLIED LIFE SCIENCES↗

SU-F-T-658: Out-Of-Field Dose Comparison for TrueBeam Low Energy Beams for Extended Distances: Measurement Vs Monte Carlo Simulation

Purpose: Patient dose far from the treatment field is comprised of scatter from within the patient, and treatment head leakage. We quantify the treatment head leakage for TrueBeam linear accelerator for 6X and 6X-FFF beams by comparing measurements to Monte Carlo simulations for a variety of jaw sizes and collimator rotations. This work is conceptually similar to that of Kry et al. (Medical Physics 2006; 33: 4405), who considered a Clinac linear accelerator. Methods: Measurements were made using an EXRADIN A101 ion chamber positioned in the patient plane, at distances up to 100 cm from isocenter. Simulations were done using VirtuaLinac, the GEANT4-based Monte Carlo model of the TrueBeam treatment head, and an in-house (U. Virginia) GEANT4-based code. In-house code modelled an ion chamber with build-up, based on a CT scan of the chamber. VirtuaLinac included a detailed model of the treatment head shielding, and was run on the Amazon Web Services cloud to generate spherical phase space files surrounding the treatment head. These phase space files were imported into the in-house code. Results: Initial comparisons between measurements and simulation showed an excess of dose in the in-plane direction, away from the gantry, in the simulations. This was traced to an incomplete model of the shielding—specifically, the component holding the primary collimator was smaller in the model than in the TrueBeam. Modifications were made to VirtuaLinac to more closely match the engineering drawings. In the in-plane direction, the lowest out of field dose was away from gantry (negative abscissa values) at around 60 cm from isocenter, for fields smaller than 10×10 cm2. Out of field dose decreased with decreasing jaw size. Flattening-filter free beam produced out-of-field doses as low as 65% of those with flattened beam. Conclusion: Doses determined from simulation and measurement were in close agreement. Funding support from the Jefferson Trust Foundation.

60 APPLIED LIFE SCIENCES↗

SU-G-206-17: RadShield: Semi-Automated Shielding Design for CT Using NCRP 147 and Isodose Curves

Purpose: Computed tomography (CT) exam rooms are shielded more quickly and accurately compared to manual calculations using RadShield, a semi-automated diagnostic shielding software package. Last year, we presented RadShield’s approach to shielding radiographic and fluoroscopic rooms calculating air kerma rate and barrier thickness at many points on the floor plan and reporting the maximum values for each barrier. RadShield has now been expanded to include CT shielding design using not only NCRP 147 methodology but also by overlaying vendor provided isodose curves onto the floor plan. Methods: The floor plan image is imported onto the RadShield workspace to serve as a template for drawing barriers, occupied regions and CT locations. SubGUIs are used to set design goals, occupancy factors, workload, and overlay isodose curve files. CTDI and DLP methods are solved following NCRP 147. RadShield’s isodose curve method employs radial scanning to extract data point sets to fit kerma to a generalized power law equation of the form K(r) = ar^b. RadShield’s semiautomated shielding recommendations were compared against a board certified medical physicist’s design using dose length product (DLP) and isodose curves. Results: The percentage error found between the physicist’s manual calculation and RadShield’s semi-automated calculation of lead barrier thickness was 3.42% and 21.17% for the DLP and isodose curve methods, respectively. The medical physicist’s selection of calculation points for recommending lead thickness was roughly the same as those found by RadShield for the DLP method but differed greatly using the isodose method. Conclusion: RadShield improves accuracy in calculating air-kerma rate and barrier thickness over manual calculations using isodose curves. Isodose curves were less intuitive and more prone to error for the physicist than inverse square methods. RadShield can now perform shielding design calculations for general scattering bodies for which isodose curves are provided.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-G-TeP1-03: Beam Quality Correction Factors for Linear Accelerator with and Without Flattening Filter

Purpose: The impact of removing the flattening filter on absolute dosimetry based on IAEA’s TPR-398 and AAPM’s TG-51 was investigated in this study using Monte Carlo simulations. Methods: The EGSnrc software package was used for all Monte Carlo simulations performed in this work. Five different ionization chambers and nine linear accelerator heads have been modeled according to technical drawings. To generate a flattening filter free radiation field the flattening filter was replaced by a 2 mm thick aluminum layer. Dose calculation in a water phantom were performed to calculate the beam quality correction factor k{sub Q} as a function of the beam quality specifiers %dd(10){sub x}, TPR{sub 20,10} and mean photon and electron energies at the point of measurement in photon fields with (WFF) and without flattening filter (FFF). Results: The beam quality correction factor as a function of %dd(10){sub x} differs systematically between FFF and WFF beams for all investigated ionization chambers. The largest difference of 1.8% was observed for the largest investigated Farmer-type ionization chamber with a sensitive volume of 0.69 cm{sup 3}. For ionization chambers with a smaller nominal sensitive volume (0.015 – 0.3 cm{sup 3}) the deviation was less than 0.4% between WFF and FFF beams for %dd(10){sub x} > 62%. The specifier TPR{sub 20,10} revealed only a good correlation between WFF and FFF beams (< 0.3%) for low energies. Conclusion: The results confirm that %dd(10){sub x} is a suitable beam quality specifier for FFF beams with an acceptable bias. The deviation depends on the volume of the ionization chamber. Using %dd(10){sub x} to predict k{sub Q} for a large volume chamber in a FFF photon field may lead to not acceptable errors according to the results of this study. This bias may be caused by the volume effect due to the inhomogeneous photon fields of FFF linear accelerators.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-07: Real-Time Image Guided Radiation Therapy for Heterotopic Ossification in Patients After Hip Replacement

Purpose: To demonstrate the feasibility of using CBCT in a real-time image guided radiation therapy (IGRT) for single fraction heterotopic ossification (HO) in patients after hip replacement. In this real-time procedure, all steps, from simulation, imaging, planning to treatment delivery, are performed at the treatment unit in one appointment time slot. This work promotes real-time treatment to create a paradigm shift in the single fraction radiation therapy. Methods: An integrated real-time IGRT for HO was developed and tested for radiation treatment of heterotopic ossification for patient after hip replacement. After CBCT images are acquired at the linac, and sent to the treatment planning system, the physician determines the field and/or draws a block. Subsequently, a simple 2D AP/PA plan with prescription of 700 cGy is created on-the-fly for physician to review. Once the physician approves the plan, the patient is treated on the same simulation position. This real-time treatment requires the team of attending physician, physicist, therapists, and dosimetrist to work in harmony to achieve all the steps in a timely manner. Results: Ten patients have been treated with this real-time treatment, having the same beams arrangement treatment plan and prescription as our clinically regular CT-based 2D plans. The average time for these procedures are 52.9 ±10.7 minutes from the time patient entered the treatment room until s/he exited, and 37.7 ±8.6 minutes from starting CBCT until last beam delivered. Conclusion: The real-time IGRT for HO treatment has been tested and implemented to be a clinically accepted procedure. This one-time appointment greatly enhances the waiting time, especially when patients in high level of pain, and provides a convenient approach for the whole clinical staff. Other disease sites will be also tested with this new technology.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRB-00: AAPM Presidential Debate [medical physics education]

Building on the energy and excitement of Washington DC in a presidential election year, AAPM will host its own Presidential Debate to better understand the views of the AAPM membership! Past presidents of the AAPM, Drs. Bayouth, Hazle, Herman, and Seibert, will debate hot topics in medical physics including issues facing education, professional practice, and the advancement of science. The moderators, Drs. Brock and Stern, will also draw in topics from Point-Counterpoint articles from the Medical Physics Journals. Wrapping up the debate, the audience will have the opportunity to question the candidates in a town hall format. At the conclusion of this lively debate, the winner will be decided by the audience, so bring your Audience Response Units! Be part of Medical Physics - Decision 2016! Learning Objectives: Understand AAPM members’ views and opinions on issues facing medical physics education Learn AAPM members’ views and opinions on issues facing professional practice Identify AAPM members’ view and opinions on issues facing the advancement of science in medical physics J. Bayouth, Funding support from NCI;Scientific Advisory Board member - ViewRay.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

MO-FG-BRB-01: Debater [medical physics education ]

Building on the energy and excitement of Washington DC in a presidential election year, AAPM will host its own Presidential Debate to better understand the views of the AAPM membership! Past presidents of the AAPM, Drs. Bayouth, Hazle, Herman, and Seibert, will debate hot topics in medical physics including issues facing education, professional practice, and the advancement of science. The moderators, Drs. Brock and Stern, will also draw in topics from Point-Counterpoint articles from the Medical Physics Journals. Wrapping up the debate, the audience will have the opportunity to question the candidates in a town hall format. At the conclusion of this lively debate, the winner will be decided by the audience, so bring your Audience Response Units! Be part of Medical Physics - Decision 2016! Learning Objectives: Understand AAPM members’ views and opinions on issues facing medical physics education Learn AAPM members’ views and opinions on issues facing professional practice Identify AAPM members’ view and opinions on issues facing the advancement of science in medical physics J. Bayouth, Funding support from NCI;Scientific Advisory Board member - ViewRay.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

MO-FG-BRB-02: Debater [medical physics education]

Building on the energy and excitement of Washington DC in a presidential election year, AAPM will host its own Presidential Debate to better understand the views of the AAPM membership! Past presidents of the AAPM, Drs. Bayouth, Hazle, Herman, and Seibert, will debate hot topics in medical physics including issues facing education, professional practice, and the advancement of science. The moderators, Drs. Brock and Stern, will also draw in topics from Point-Counterpoint articles from the Medical Physics Journals. Wrapping up the debate, the audience will have the opportunity to question the candidates in a town hall format. At the conclusion of this lively debate, the winner will be decided by the audience, so bring your Audience Response Units! Be part of Medical Physics - Decision 2016! Learning Objectives: Understand AAPM members’ views and opinions on issues facing medical physics education Learn AAPM members’ views and opinions on issues facing professional practice Identify AAPM members’ view and opinions on issues facing the advancement of science in medical physics J. Bayouth, Funding support from NCI;Scientific Advisory Board member - ViewRay.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-FG-BRB-03: Debater [medical physics education]

Building on the energy and excitement of Washington DC in a presidential election year, AAPM will host its own Presidential Debate to better understand the views of the AAPM membership! Past presidents of the AAPM, Drs. Bayouth, Hazle, Herman, and Seibert, will debate hot topics in medical physics including issues facing education, professional practice, and the advancement of science. The moderators, Drs. Brock and Stern, will also draw in topics from Point-Counterpoint articles from the Medical Physics Journals. Wrapping up the debate, the audience will have the opportunity to question the candidates in a town hall format. At the conclusion of this lively debate, the winner will be decided by the audience, so bring your Audience Response Units! Be part of Medical Physics - Decision 2016! Learning Objectives: Understand AAPM members’ views and opinions on issues facing medical physics education Learn AAPM members’ views and opinions on issues facing professional practice Identify AAPM members’ view and opinions on issues facing the advancement of science in medical physics J. Bayouth, Funding support from NCI;Scientific Advisory Board member - ViewRay.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

MO-FG-BRB-04: Debater [ Medical physics education ]

Building on the energy and excitement of Washington DC in a presidential election year, AAPM will host its own Presidential Debate to better understand the views of the AAPM membership! Past presidents of the AAPM, Drs. Bayouth, Hazle, Herman, and Seibert, will debate hot topics in medical physics including issues facing education, professional practice, and the advancement of science. The moderators, Drs. Brock and Stern, will also draw in topics from Point-Counterpoint articles from the Medical Physics Journals. Wrapping up the debate, the audience will have the opportunity to question the candidates in a town hall format. At the conclusion of this lively debate, the winner will be decided by the audience, so bring your Audience Response Units! Be part of Medical Physics - Decision 2016! Learning Objectives: Understand AAPM members’ views and opinions on issues facing medical physics education Learn AAPM members’ views and opinions on issues facing professional practice Identify AAPM members’ view and opinions on issues facing the advancement of science in medical physics J. Bayouth, Funding support from NCI;Scientific Advisory Board member - ViewRay.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

WE-A-201-00: Anne and Donald Herbert Distinguished Lectureship On Modern Statistical Modeling

Chris Marshall: Memorial Introduction Donald Edmonds Herbert Jr., or Don to his colleagues and friends, exemplified the “big tent” vision of medical physics, specializing in Applied Statistics and Dynamical Systems theory. He saw, more clearly than most, that “Making models is the difference between doing science and just fooling around [ref Woodworth, 2004]”. Don developed an interest in chemistry at school by “reading a book” - a recurring theme in his story. He was awarded a Westinghouse Science scholarship and attended the Carnegie Institute of Technology (later Carnegie Mellon University) where his interest turned to physics and led to a BS in Physics after transfer to Northwestern University. After (voluntary) service in the Navy he earned his MS in Physics from the University of Oklahoma, which led him to Johns Hopkins University in Baltimore to pursue a PhD. The early death of his wife led him to take a salaried position in the Physics Department of Colorado College in Colorado Springs so as to better care for their young daughter. There, a chance invitation from Dr. Juan del Regato to teach physics to residents at the Penrose Cancer Hospital introduced him to Medical Physics, and he decided to enter the field. He received his PhD from the University of London (UK) under Prof. Joseph Rotblat, where I first met him, and where he taught himself statistics. He returned to Penrose as a clinical medical physicist, also largely self-taught. In 1975 he formalized an evolving interest in statistical analysis as Professor of Radiology and Head of the Division of Physics and Statistics at the College of Medicine of the University of South Alabama in Mobile, AL where he remained for the rest of his career. He also served as the first Director of their Bio-Statistics and Epidemiology Core Unit working in part on a sickle-cell disease. After retirement he remained active as Professor Emeritus. Don served for several years as a consultant to the Nuclear Regulatory Commission and may be remembered for his critique of the National Academy of Sciences BEIR III report (stating that their methodology “imposes a Delphic quality to the .. risk estimates”.) This led to his appointment as a member of the BEIR V committee. Don presented refresher courses at the AAPM, ASTRO and RSNA meetings and was active in the AAPM as a member or chair of several committees. He was the principal author of AAPM Report 43, which is essentially a critique of established clinical studies prior to 1992. He was co-editor of the Proceedings of many symposia on Time, Dose and Fractionation held in Madison, Wisconsin. He received the AAPM lifetime Achievement award in 2004. Don’s second wife of 46 years, Ann, predeceased him and he is survived by daughters Hillary and Emily, son John and two grandsons. Don was a true gentleman with a unique and erudite writing style illuminated by pithy quotations. If he had a fault it was, perhaps, that he did not realize how much smarter he was than the rest of us. This presentation draws heavily on a biography and video interview in the History and Heritage section of the AAPM website. The quote is his own. Andrzej Niemierko: Statistical modeling plays an essential role in modern medicine for quantitative evaluation of the effect of treatment. This session will feature an overview of statistical modeling techniques used for analyzing the many types of research data and an exploration of recent advances in new statistical modeling methodologies. Learning Objectives: To learn basics of statistical modeling methodology. To discuss statistical models that are frequently used in radiation oncology To discuss advanced modern statistical modeling methods and applications.

60 APPLIED LIFE SCIENCES↗

WE-A-201-01: Memorial Introduction

Chris Marshall: Memorial Introduction Donald Edmonds Herbert Jr., or Don to his colleagues and friends, exemplified the “big tent” vision of medical physics, specializing in Applied Statistics and Dynamical Systems theory. He saw, more clearly than most, that “Making models is the difference between doing science and just fooling around [ref Woodworth, 2004]”. Don developed an interest in chemistry at school by “reading a book” - a recurring theme in his story. He was awarded a Westinghouse Science scholarship and attended the Carnegie Institute of Technology (later Carnegie Mellon University) where his interest turned to physics and led to a BS in Physics after transfer to Northwestern University. After (voluntary) service in the Navy he earned his MS in Physics from the University of Oklahoma, which led him to Johns Hopkins University in Baltimore to pursue a PhD. The early death of his wife led him to take a salaried position in the Physics Department of Colorado College in Colorado Springs so as to better care for their young daughter. There, a chance invitation from Dr. Juan del Regato to teach physics to residents at the Penrose Cancer Hospital introduced him to Medical Physics, and he decided to enter the field. He received his PhD from the University of London (UK) under Prof. Joseph Rotblat, where I first met him, and where he taught himself statistics. He returned to Penrose as a clinical medical physicist, also largely self-taught. In 1975 he formalized an evolving interest in statistical analysis as Professor of Radiology and Head of the Division of Physics and Statistics at the College of Medicine of the University of South Alabama in Mobile, AL where he remained for the rest of his career. He also served as the first Director of their Bio-Statistics and Epidemiology Core Unit working in part on a sickle-cell disease. After retirement he remained active as Professor Emeritus. Don served for several years as a consultant to the Nuclear Regulatory Commission and may be remembered for his critique of the National Academy of Sciences BEIR III report (stating that their methodology “imposes a Delphic quality to the .. risk estimates”.) This led to his appointment as a member of the BEIR V committee. Don presented refresher courses at the AAPM, ASTRO and RSNA meetings and was active in the AAPM as a member or chair of several committees. He was the principal author of AAPM Report 43, which is essentially a critique of established clinical studies prior to 1992. He was co-editor of the Proceedings of many symposia on Time, Dose and Fractionation held in Madison, Wisconsin. He received the AAPM lifetime Achievement award in 2004. Don’s second wife of 46 years, Ann, predeceased him and he is survived by daughters Hillary and Emily, son John and two grandsons. Don was a true gentleman with a unique and erudite writing style illuminated by pithy quotations. If he had a fault it was, perhaps, that he did not realize how much smarter he was than the rest of us. This presentation draws heavily on a biography and video interview in the History and Heritage section of the AAPM website. The quote is his own. Andrzej Niemierko: Statistical modeling plays an essential role in modern medicine for quantitative evaluation of the effect of treatment. This session will feature an overview of statistical modeling techniques used for analyzing the many types of research data and an exploration of recent advances in new statistical modeling methodologies. Learning Objectives: To learn basics of statistical modeling methodology. To discuss statistical models that are frequently used in radiation oncology To discuss advanced modern statistical modeling methods and applications.

60 APPLIED LIFE SCIENCES↗

WE-A-201-02: Modern Statistical Modeling

Chris Marshall: Memorial Introduction Donald Edmonds Herbert Jr., or Don to his colleagues and friends, exemplified the “big tent” vision of medical physics, specializing in Applied Statistics and Dynamical Systems theory. He saw, more clearly than most, that “Making models is the difference between doing science and just fooling around [ref Woodworth, 2004]”. Don developed an interest in chemistry at school by “reading a book” - a recurring theme in his story. He was awarded a Westinghouse Science scholarship and attended the Carnegie Institute of Technology (later Carnegie Mellon University) where his interest turned to physics and led to a BS in Physics after transfer to Northwestern University. After (voluntary) service in the Navy he earned his MS in Physics from the University of Oklahoma, which led him to Johns Hopkins University in Baltimore to pursue a PhD. The early death of his wife led him to take a salaried position in the Physics Department of Colorado College in Colorado Springs so as to better care for their young daughter. There, a chance invitation from Dr. Juan del Regato to teach physics to residents at the Penrose Cancer Hospital introduced him to Medical Physics, and he decided to enter the field. He received his PhD from the University of London (UK) under Prof. Joseph Rotblat, where I first met him, and where he taught himself statistics. He returned to Penrose as a clinical medical physicist, also largely self-taught. In 1975 he formalized an evolving interest in statistical analysis as Professor of Radiology and Head of the Division of Physics and Statistics at the College of Medicine of the University of South Alabama in Mobile, AL where he remained for the rest of his career. He also served as the first Director of their Bio-Statistics and Epidemiology Core Unit working in part on a sickle-cell disease. After retirement he remained active as Professor Emeritus. Don served for several years as a consultant to the Nuclear Regulatory Commission and may be remembered for his critique of the National Academy of Sciences BEIR III report (stating that their methodology “imposes a Delphic quality to the .. risk estimates”.) This led to his appointment as a member of the BEIR V committee. Don presented refresher courses at the AAPM, ASTRO and RSNA meetings and was active in the AAPM as a member or chair of several committees. He was the principal author of AAPM Report 43, which is essentially a critique of established clinical studies prior to 1992. He was co-editor of the Proceedings of many symposia on Time, Dose and Fractionation held in Madison, Wisconsin. He received the AAPM lifetime Achievement award in 2004. Don’s second wife of 46 years, Ann, predeceased him and he is survived by daughters Hillary and Emily, son John and two grandsons. Don was a true gentleman with a unique and erudite writing style illuminated by pithy quotations. If he had a fault it was, perhaps, that he did not realize how much smarter he was than the rest of us. This presentation draws heavily on a biography and video interview in the History and Heritage section of the AAPM website. The quote is his own. Andrzej Niemierko: Statistical modeling plays an essential role in modern medicine for quantitative evaluation of the effect of treatment. This session will feature an overview of statistical modeling techniques used for analyzing the many types of research data and an exploration of recent advances in new statistical modeling methodologies. Learning Objectives: To learn basics of statistical modeling methodology. To discuss statistical models that are frequently used in radiation oncology To discuss advanced modern statistical modeling methods and applications.

60 APPLIED LIFE SCIENCES↗

WE-AB-207B-09: Margin Reduction for Planning Target Volume (PTV) in Patients with Localized Prostate Cancer: Impact On Delivered Dose and Quality of Life

Purpose: To estimate the delivered (cumulative) dose to targets and organs at risk for localized prostate cancer patients treated with reduced PTV margins and to evaluate preliminary patient reported quality-of-life (QOL). Methods: Under an IRB-approved protocol, 20 prostate cancer patients (including 11 control patients) were treated with reduced planning margins (5 mm uniform with 4 mm at prostate/rectum interface). Control patients had standard margin (10/6 mm)-based treatments. A parameter-optimized Elastix algorithm along with energy-mass mapping was used to deform and resample dose of the day onto the planning CT for each fraction to estimate the delivered dose over all fractions. QOL data were collected via Expanded Prostate cancer Index Composite (EPIC-26) questionnaires at time points pre-treatment, post-treatment, and at 2, 6, 12, 18 month follow-ups. Standardized QOL scores [range: 0–100] were determined and baseline-corrected by subtracting pre-treatment QOL data. Mean QOL differences between the margin reduced group and control group (QOLmr-QOLcontrol) were calculated for first 18 months. Results: The difference between the cumulative mean dose (Dmean) and the planned mean dose (±SD) for PTV, prostate, bladder, and rectum were −2.2±1.0, 0.3±0.5, −0.7±2.6, and −2.1±1.3 Gy respectively for the margin-reduced group, and −0.8±2.0, 0.9±1.4, - 0.7±3.1 and −1.0±2.4 Gy for the control group. Difference between the two groups was statistically insignificant (p=0.1). Standardized and baseline corrected QOLmr-QOLcontrol for EPIC domains categorized as “Urinary Incontinence”, “Urinary Irritative/Obstructive”, “Bowel”, “Sexual”, and “Hormonal” were 0.6, 12.1, 9.1, 13.3, and −0.9 for the 18 months following radiation therapy (higher values better). Delivered dose to rectum showed a weak correlation to “Bowel” domain (Pearson’s coefficient −0.24, p<0.001), while bladder dose did not correlate to Urinary Incontinence/Irritative/Obstructive QOL domains. Conclusion: The margin-reduced group exhibited clinically meaningful improvement of QOL without compromising the PTV dose. A larger number of patients and greater follow-up is needed to draw unequivocal conclusions. This work was supported in part by a research grant from Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

WE-FG-202-03: Quantitative CT-Based Analysis to Assess Lung Injury Following Proton Radiotherapy

Purpose: Relative to photon alternatives, the increased dose-conformity associated with proton therapy is expected to reduce the extent of radiation-induced lung toxicity. However, analysis of follow-up data is yet to be published in this area. In this study we retrospectively analyzed late-phase HU changes for proton therapy cohorts of chest wall and lung patients. Methods: From our institution’s register of patients treated using double-scattered protons, all chest wall and stereotactic lung cases (treated 2011–2012 and 2008–2014 respectively) were initially considered. Follow-up CT data were accessible for 10 chest wall cases (prescribed 50.4 GyRBE in 28 fractions) and 16 lung cases (prescribed 42–50 GyRBE in 3–4 fractions). CT time-points ranged from 0.5–3.5 years post-treatment. Planning doses were recalculated using TOPAS Monte Carlo simulations and mapped onto the follow-up images using deformable registration. Excluding internal target volumes, changes in HU between each patient’s planning and follow-up CT(s) were evaluated for dose bins of 2–30 GyRBE (2 GyRBE increments). Results: Linear increases in HU per unit dose, with correlations statistically significant at the 1% level (one-sided Spearman’s rank test), were evident for all 10 chest wall cases and 14/16 lung cases. The mean changes in HU/Gy were: 1.76 (SD=0.73) for the chest wall cohort, and 1.40 (SD=0.87) for the lung cohort. The median scan times post treatment were 21 and 12 months respectively. All 26 patients developed solid consolidation (scar-like radiographic opacities) within the exposed lung(s). Conclusion: Analysis of follow-up CTs revealed statistically significant correlations in HU-change/dose for two proton cohorts (lung and chest wall). Quantitatively, the late-phase changes we report broadly match published photon data. Further analysis of such radiographic changes, particularly via matched cohort studies drawing upon consistent imaging protocols, could play an important role in elucidating inter-modality differences and provide insight into proton RBE for lung injury. Tracy Underwood gratefully acknowledges the support of the European Commission under an FP7 Marie Curie International Outgoing Fellowship for Career Development (#630064). This work was also funded under U19 grant CA 021239 (PI: Delaney).

60 APPLIED LIFE SCIENCES↗

Poster - 03: How to manage a nuclear medicine PET-CT for radiation oncology patients

Purpose: Development of an adapted multidisciplinary procedure designed to optimize the clinical workflow between radiation therapy (RT) and nuclear medicine (NM) for a PET-CT located in the NM department. Methods : The radiation oncologist (RO) prescribes the PET-CT exam and the clinical RT therapist gives all the necessary information to the patient prior to the exam. The immobilization accessories are prepared in the RT department. The RT and NM therapists work together for radiotracer injection, patient positioning and scan acquisition. The nuclear medicine physician (NMP) will study the images, draw Biological Target Volumes (BTVs) and produce a full exam report. Results : All tasks related to a planning PET-CT are done within 48 hours from the request by the RO to the reception of the images with the NMP contours and report. Conclusions : By developing a complete procedure collectively between the RT and NM departments, the patient benefits of a quick access to a RT planning PET-CT exam including the active involvement of every medical practitioners in these fields.

60 APPLIED LIFE SCIENCES↗