Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnosability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

A compact and portable gamma-ray spectrometer (GRASP) for inertial confinement fusion and basic science experiments

A compact and portable gamma-ray spectrometer has been designed to diagnose different components of the inertial confinement fusion-relevant γ-ray spectrum with energies between ∼3.7–17.9 MeV. The system is designed to be as compact as possible for convenient transportation and fielding in diagnostic ports on the OMEGA laser, the National Ignition Facility, and other photon-source facilities. The system consists of a conversion foil for Compton scattering in front of four magnetic spectrometer “arms,” each covering a different energy range and constructed out of cylindrical permanent magnet Halbach arrays. Monte Carlo simulations have been used to optimize and assess the performance of the conversion foil, and COSY INFINITY ion-optical simulations have been used to optimize the spectrometer magnets. The performance of the design is assessed for a simulated direct-drive γ-ray spectrum. Spanning its total γ-ray energy bandwidth and using a 1.7 mm thick boron conversion foil, the system’s total energy resolution and efficiency are ∼15.8%–4.5% and 5.4 × 10−7–3.7 × 10−7e−/γ, respectively, with room for improvement. Spectral γ-ray measurements will provide guidance to the inertial confinement fusion program toward achieving high-energy gain relevant to inertial fusion energy and enable new measurement capabilities for basic discovery science.

Instruments & Instrumentation↗

A Q-band frequency tunable Doppler backscattering (DBS) system for pedestal and scrape-off layer density fluctuation and flow measurements in the DIII-D tokamak

We present the design and laboratory tests for a new Q-band frequency tunable Doppler backscattering (DBS) system suitable for probing poloidal wavenumber kñ = 6–8 cm−1 density fluctuations and their flow velocities in the pedestal and scape-off layer (SOL) of the DIII-D tokamak. This system will provide new measurements in the increasingly important and under-diagnosed far pedestal and SOL plasma regions. These results are important for experimental transport studies and necessary for the validation of transport models, both of which are important to fusion energy research. The use of a single tunable frequency reduces the complexity and potential failure points as compared to a multichannel system. This new system utilizes a 33–50 GHz tunable source and will be integrated into the current V-band DBS in DIII-D using a broadband Q- and V-band multiplexer. A full-scale mockup of the quasi-optical system was used to test and optimize the performance. These tests include beam profile measurements at different distances (and angles) from a paraboloidal focusing and steering mirror. The measurements cover the full frequency range 33–75 GHz of the integrated/combined Q–V band DBS system and target a large radial coverage of the low-field side of the plasma from ρ = 1.1 to ρ = 0.5, where ρ is the normalized flux surface radial coordinate.

Instruments & Instrumentation↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental methods to test photoionized plasma models in emission

The expanding foil photoionized plasma platform was developed on the Z-machine at Sandia National Laboratories to produce terrestrial photoionized plasmas at some of the same conditions as those observed in astrophysical black hole accretion disks. The specific scientific goals of the platform are motivated by long-standing astrophysical puzzles related to accreting black hole systems. Ultimately, the experimental goal is to inform the supersolar Fe abundance problem by testing photoionized plasma models in emission with at-parameter laboratory data. High quality high resolution emission data with absolute intensity calibration from a laboratory photoionized plasma have never been collected prior to the experiments described here, providing broader motivation. A robust test of the model predictions requires the successful production of a laboratory photoionized plasma along with measurements of the supporting model inputs including the radiation drive spectrum used to create the photoionized plasma, the electron density, and the temperature. The measured absolute spectral radiance in emission collected from the independently diagnosed plasma can be compared against model calculations performed using the measured inputs. In this paper, we focus on the experimental platform and the model inputs, specifically detailing the methodology used to measure the plasma conditions. The moderate electron temperature of ∼41 eV ± 15 eV and electron density of ∼1e19 ± 1.6e18 e−/cm3 and the ∼3e12 W/cm2 x-ray irradiance at the sample confirm that photoionization dominates the plasma ionization and spectra.

Cho, P. B. (ORCID:0000000291632905)↗

Effects of mosaic crystal instrument functions on x-ray Thomson scattering diagnostics

Mosaic crystals, with their high integrated reflectivities, are widely employed in spectrometers used to diagnose high energy density systems. X-ray Thomson scattering (XRTS) has emerged as a powerful diagnostic tool of these systems, providing in principle direct access to important properties such as the temperature via detailed balance. However, the measured XRTS spectrum is broadened by the spectrometer instrument function (IF), and without careful consideration of the IF one risks misdiagnosing system conditions. Here, we consider in detail the IF of 40 and 100 μm mosaic Highly Annealed Pyrolytic Graphite crystals, and how the broadening varies across the spectrometer in an energy range of 6.7–8.6 keV. Notably, we find a strong asymmetry in the shape of the IF toward higher energies. As an example, we consider the effect of the asymmetry in the IF on the temperature inferred via XRTS for simulated 80 eV CH plasmas and find that the temperature can be overestimated if an approximate symmetric IF is used. We, therefore, expect a detailed consideration of the full IF will have an important impact on system properties inferred via XRTS in both forward modeling and model-free approaches.

47 OTHER INSTRUMENTATION↗

A circuit-generated quantum subspace algorithm for the variational quantum eigensolver

Recent research has shown that wavefunction evolution in real and imaginary time can generate quantum subspaces with significant utility for obtaining accurate ground state energies. Inspired by these methods, we propose combining quantum subspace techniques with the variational quantum eigensolver (VQE). In our approach, the parameterized quantum circuit is divided into a series of smaller subcircuits. The sequential application of these subcircuits to an initial state generates a set of wavefunctions that we use as a quantum subspace to obtain high-accuracy groundstate energies. We call this technique the circuit subspace variational quantum eigensolver (CSVQE) algorithm. By benchmarking CSVQE on a range of quantum chemistry problems, we show that it can achieve significant error reduction in the best case compared to conventional VQE, particularly for poorly optimized circuits, greatly improving convergence rates. Furthermore, we demonstrate that when applied to circuits trapped at local minima, CSVQE can produce energies close to the global minimum of the energy landscape, making it a potentially powerful tool for diagnosing local minima.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrodynamic expansion and near-infrared absorption of x-ray heated aluminum plasmas

We use x-ray pulses from dense argon plasmas at the Z Machine (Sandia National Laboratories) to generate hypersonic aluminum plasmas akin to material ejecta during proposed planetary defense missions, fusion reactor wall excursions, and other high-energy density processes. Near-infrared absorption is used to diagnose the controlled expansion of the plasmas through cylindrical cavities following their generation from x-ray heating of solid aluminum 7075 alloy. The data are compared to multidimensional radiation hydrodynamics simulations utilizing the ALEGRA multiphysics code, accounting for the dynamics of radiation scattering, material phase change, plasma expansion, thermal re-irradiation, and interactions with the cavity and with the infrared beams. To allow for accurate simulation, density functional theory is used to apply the Hagen–Rubens relation for the far-infrared and is adjoined with a detailed configuration accounting model using the Propaceos code, producing opacities spanning 10 −1 –10 4 eV photon energy for aluminum 7075 alloy, and in comparison with pure aluminum. The model is found to agree with experimental data in the higher-fluence regime when the Hagen–Rubens relation is applied. The ejected material, which is observed to travel up to 55 km/s, is comprised of a strongly ionized, non-LTE plasma front at ∼10 eV temperature followed by a weakly ionized LTE gas at higher density. The present findings lend some confidence to the broad-range equation of state and infrared opacity models for weakly ionized aluminum plasmas while demonstrating an approach to their future refinement, with potential application to astrophysical plasmas and other extreme processes.

Adiabatic process↗

Distortions in charged-particle images of laser direct-drive inertial confinement fusion implosions

Energetic charged particles generated by inertial confinement fusion (ICF) implosions encode information about the spatial morphology of the hotspot and dense fuel during the time of peak fusion reactions. The knock-on deuteron imager (KoDI) was developed at the Omega Laser Facility to image these particles in order to diagnose low-mode asymmetries in the hotspot and dense fuel layer of cryogenic deuterium–tritium ICF implosions. However, the images collected are distorted in several ways that prevent reconstruction of the deuteron source. In this paper, we describe these distortions and a series of attempts to mitigate or compensate for them. We present several potential mechanisms for the distortions, including a new model for scattering of charged particles in filamentary electric or magnetic fields surrounding the implosion. Particle-tracing is used to create synthetic KoDI data based on the filamentary field model that reproduces the main experimentally observed image distortions. We conclude that the filamentary scattering model best matches the observed image distortions. Finally, we discuss potential impacts of filamentary fields on other charged-particle diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray absorption spectroscopy measurements of radiatively ionized argon gas

X-ray absorption spectroscopy is a diagnostic tool that can characterize the temperature and ionization state of a plasma. This technique requires experiments to characterize the platform, careful data calibration, and comparison with atomic models to understand the plasma parameters. We performed ionizing radiation wave experiments at the OMEGA Laser Facility that used an ∼ 80 eV X-ray source to heat an Argon (Ar) gas cell at fill pressures of 3 atm. To diagnose the Ar plasma, we used a capsule backlighter offset 10 mm from the gas cell, to produce X-rays that were absorbed by the ionized Ar gas. The absorption analysis was calibrated using the significant line structure in the backlighter spectrum, which served as independent energy fiducials enabling definitive measurements of a 50-eV shift in the energy of the Ar K-edge due to ionization. We compare the measured absorption spectra to two independent atomic models, PrismSPECT and SCRAM, and show that the observed K-edge shift in the heated gas is consistent with ionization up to Ar 4+ and temperatures of 10 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of ultrafast laser pulse repetition rate on filament acoustic and emission signatures

Femtosecond filaments formed at standoff distances can be used for interrogating various types of matter, making them of potential interest for remote sensing. However, the physical aspects of the filaments generated at standoff distances are influenced by various environmental and laser properties, including the repetition rate of the laser. In this study, we evaluate the role of the predecessor pulse on the properties of filaments by varying the repetition rate of the laser in the range of 10–1000 Hz and using acoustic and emission signatures to diagnose filament properties. Our results show that filaments are brighter at high repetition rates while they are elongated at low repetition rates. The repetition rate has minimal influence on the downstream edge of the filament generation, while the upstream edge becomes elongated. The shadowgram images showed that the turbulence generated by the predecessor pulse may influence the next pulse when the laser is operating at high repetition rates.

47 OTHER INSTRUMENTATION↗

Three-dimensional reconstruction of inertial confinement fusion hot-spot plasma from x-ray and nuclear diagnostics on OMEGA

Multidimensional effects degrade the neutron yield and the compressed areal density of laser-direct-drive inertial confinement fusion implosions of layered deuterium–tritium cryogenic targets on the OMEGA Laser System with respect to 1D radiation-hydrodynamic simulation predictions. A comprehensive physics-informed 3D reconstruction effort is under way to infer hot-spot and shell conditions at stagnation from four x-ray and seven neutron detectors distributed around the OMEGA target chamber. Neutron diagnostics, providing measurements of the neutron yield, hot-spot flow velocity, and apparent ion-temperature distribution, are used to infer the mode-1 perturbation at stagnation. The x-ray imagers record the shape of the hot-spot plasma to diagnose mode-1 and mode-2 perturbations. A deep-learning convolutional neural network trained on an extensive set of 3D radiation-hydrodynamic simulations is used to interpret the x-ray and nuclear measurements to infer the 3D profiles of the hot-spot plasma conditions and the amount of laser energy coupled to the hot-spot plasma. A 3D simulation database shows that larger mode-1 asymmetries are correlated with higher hot-spot flow velocities and reduced laser-energy coupling and neutron yield. Three-dimensional hot-spot reconstructions from x-ray measurements indicate that higher amounts of residual kinetic energy are correlated with higher measured hot-spot flow velocities, consistent with 3D simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of macroscopic surface defects on dynamic damage: An experimental and numerical study

This study examines the impact of macroscopic surface defects on the dynamic ductile damage behavior of polycrystalline metals using plate-impact experiments. Defects of various shapes (flat, round, and point) were manufactured on the free or impact surfaces of annealed copper specimens. The experiments were diagnosed with photon Doppler velocimetry measurements and soft recovery techniques. The experimental results revealed that defect shape and location significantly affect velocity–time profiles and void distribution. In order to understand the dynamics of shock propagation and corresponding ductile damage evolution within the target specimens, the impact experiments were modeled with a calibrated Tepla model, a dynamic ductile damage model for polycrystalline metals [Nguyen et al., Int. J. Solids Struct. 329, 113833 (2026)]. Overall, our resulting simulated velocity showed good agreement with measured velocity, and our simulated porosity distributions qualitatively matched experimental data. Based on our simulation results, defects on the free surface were found to distort rarefaction waves and therefore the corresponding spall planes. On the other hand, defects on the impact surface generated a delayed shock when the flyer plate and the defected target area were in contact, leading to distortion of the spall plane. The distortion of the spall plane resulted in a non-uniform distribution of voids within the defected specimens. Lastly, we examined the role of local work hardening due to the defect manufacturing process on the velocity and porosity distribution, using Tepla simulations with a simplified representation of local hardening. This investigation highlights the importance of defect geometry, location, and local hardening associated with defect generation in dynamic ductile damage processes.

36 MATERIALS SCIENCE↗

Hyperspectral radiance mapping and chromatic correction for temperature measurement in laser-heated diamond anvil cells

In laser-heated diamond anvil cell (DAC) experiments, the effective heated region typically decreases in size with increasing pressure, leading to steeper thermal gradients. Under these conditions, chromatic aberration in the optical path from sample to detector can significantly create bias in spectro-radiometric temperature measurement. We present a radiance-mapping approach using a hyperspectral camera that records 25 spectral channels spanning 605–875 nm at each pixel in a single exposure, providing spatially and spectrally resolved radiance in each frame. This enables chromatic effects to be recorded and corrected in data processing. We developed a procedure for hyperspectral mapping, involving per-camera calibration, crosstalk removal, measured spectral throughput functions, and optional sub-pixel co-registration to minimize chromatic distortion. The calibrated radiance maps are then used to derive temperature maps of the laser-heated hotspots. For smaller heating spots, the radiance mapping approach reveals chromatic shifts that conventional spectro-radiometric methods cannot quantify. Ambient-pressure heating experiments confirm accurate temperature retrieval. At high pressure, application of the hyperspectral system to a platinum-heating experiment at 12 GPa demonstrates stable temperature reconstruction under steep thermal gradients. Beyond mitigating chromatic aberrations, the ability to diagnose optical artifacts separately from emissivity variations during controlled test experiments or in situ suggests a path toward more rigorous spectral emissivity analysis and improved modeling of thermal transport in laser-heated DAC experiments.

47 OTHER INSTRUMENTATION↗

Laser refractography of optically inhomogeneous media

The basic principles of laser refractography, a new method for diagnostics of optically inhomogeneous media and flows based on refraction of spatially structured laser radiation, are described. By using 2D- and 3D-refraction patterns, the medium under investigation can be visualised and the inhomogeneity profile can be diagnosed quantitatively. The method is modified for studying edge effects and thin boundary layers in liquids and gases. Due to nearly inertialess measurements, laser refractography can be used for diagnostics of fast and transient processes. The simultaneous diagnostics of processes in various regions is provided by an extended radiation source. (adaptive optics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation of the generation of the characteristic X-ray emission by hot electrons in a foil

We have developed a model to calculate the yield of the characteristic X-ray radiation from a foil, taking into account the dependence of the average energy and the number of hot electrons on the intensity of the laser pulse, the self-absorption of X-rays and the effect of refluxing of hot electrons. The yield of K{sub {alpha}} radiation from a silver foil is optimised at relativistic intensities. A method is proposed for diagnosing the effect of electron refluxing, which greatly increases the yield of K{sub {alpha}} radiation. (extreme light fields and their applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deformation dynamics and spallation strength of aluminium under a single-pulse action of a femtosecond laser

An interferometric method is developed and realised using a frequency-modulated pulse for diagnosing a dynamics of fast deformations with a spatial and temporal resolution under the action of a single laser pulse. The dynamics of a free surface of a submicron-thick aluminium film is studied under an action of the ultrashort compression pulse with the amplitude of up to 14 GPa, excited by a femtosecond laser heating of the target surface layer. The spallation strength of aluminium was determined at a record high deformation rate of 3 Multiplication-Sign 10{sup 9} s{sup -1}. (extreme light fields and their applications)

74 ATOMIC AND MOLECULAR PHYSICS↗

X-ray spectral diagnostics of laser harmonic generation in the interaction of relativistic femtosecond laser pulses with clusters

It is shown that the production of X-ray emission spectra in the interaction of high-intensity laser radiation with cluster targets may be affected by the bichromatic oscillating electric field arising from the generation of the second harmonic of laser radiation. A technique is proposed for diagnosing harmonic generation in laser – cluster interactions using the spectral line profiles of multiply charged helium ions. The efficiency of second harmonic generation at a laser intensity of 3 × 10{sup 18} W cm{sup -2} is shown to amount to about 2%. (extreme laser radiation: physics and fundamental applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On angiography with a Thomson laser-electron X-ray generator

We consider a possibility of application of laser-electron X-ray generators for diagnosing the vessel status of internal organs. It is shown that modern lasers and linear accelerators can be used for the development of angiographic instruments of a new type with an increased spatial and temporal resolution while maintaining or reducing the radiation load on the patient and medical staff. Such improvements in diagnostic and ambient factors cannot be achieved with the use of X-ray tubes. All particular estimates and calculations have been performed for a contrast agent based on iodine compounds. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗