Prospects for direct detection of inflationary gravitational waves by next generation interferometric detectors

We study the potential impact of detecting the inflationary gravitational wave background by the future space-based gravitational wave detectors, such as DECIGO and BBO. The signal-to-noise ratio of each experiment is calculated for chaotic/natural/hybrid inflation models by using the precise predictions of the gravitational wave spectrum based on numerical calculations. We investigate the dependence of each inflation model on the reheating temperature which influences the amplitude and shape of the spectrum, and find that the gravitational waves could be detected for chaotic/natural inflation models with high reheating temperature. From the detection of the gravitational waves, a lower bound on the reheating temperature could be obtained. The implications of this lower bound on the reheating temperature for particle physics are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Edge Vibrations of Graphane Nanoribbons

Using the COMPASS force field, natural linear vibrations of graphane (graphene hydrogenated on both sides) nanoribbons are simulated. The frequency spectrum of a graphane sheet consists of three continuous intervals (low-frequency, mid-frequency, and narrow high-frequency) and two gaps between them. The construction of dispersion curves for nanoribbons with a zigzag and chair structure of the edges show that the frequencies of edge vibrations (edge phonons) can be present in the gaps of the frequency spectrum. In the first type of nanoribbons, two dispersion curves are in the low-frequency gap of the spectrum and four dispersion curves in the second gap. These curves correspond to phonons moving only along the nanoribbon edges (the mean depth of their penetration toward the nanoribbon center does not exceed 0.15 nm).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-E-J-125: Classification of CBCT Noises in Terms of Their Contribution to Proton Range Uncertainty

Purpose: This study assesses the potential use of CBCT images in adaptive protontherapy by estimating the contribution of the main sources of noise and calibration errors to the proton range uncertainty. Methods: Measurements intended to highlight each particular source have been achieved by adapting either the testbench configuration, e.g. use of filtration, fan-beam collimation, beam stop arrays, phantoms and detector reset light, or the sequence of correction algorithms including water precorrection. Additional Monte-Carlo simulations have been performed to complement these measurements, especially for the beam hardening and the scatter cases. Simulations of proton beams penetration through the resulting images have then been carried out to quantify the range change due to these effects. The particular case of a brain irradiation is considered mainly because of the multiple effects that the skull bones have on the internal soft tissues. Results: On top of the range error sources is the undercorrection of scatter. Its influence has been analyzed from a comparison of fan-beam and full axial FOV acquisitions. In this case, large range errors of about 12 mm can be reached if the assumption is made that the scatter has only a constant contribution over the projection images. Even the detector lag, which a priori induces a much smaller effect, has been shown to contribute for up to 2 mm to the overall error if its correction only aims at reducing the skin artefact. This last result can partially be understood by the larger interface between tissues and bones inside the skull. Conclusion: This study has set the basis of a more systematical analysis of the effect CBCT noise on range uncertainties based on a combination of measurements, simulations and theoretical results. With our method, even more subtle effects such as the cone-beam artifact or the detector lag can be assessed. SBR and JOR are financed by iMagX, a public-private partnership between the region Wallone of Belgium and IBA under convention #1217662.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Local structure of zinc–indium–tin oxide films via grazing-incidence x-ray pair-distribution functions and theoretical methods

A detailed experimental and theoretical study on the local (r ≤ 4.5 Å) atomic structure of amorphous and crystalline zinc–indium–tin oxide (ZITO) thin films using grazing-incidence x-ray Pair-Distribution Functions (PDFs), ab initio Molecular Dynamics (MD), and Empirical Potential Structure Refinement (EPSR) Monte Carlo simulations is presented. High-energy synchrotron x rays, a two-dimensional detector, and different incident angles were used to probe the depth uniformity of five (ZnO) 0.15 (In 2 O 3 ) 0.70 (SnO 2 ) 0.15 films that were deposited via pulsed-laser deposition at growth temperatures (T G ) ranging from 25 to 300 °C. Films deposited at T G ≤ 150 °C were amorphous. The partially crystalline (T G = 200 °C) and fully crystalline (T G = 300 °C) films were highly textured. Both crystalline and amorphous structures were investigated using ab initio MD and EPSR Monte Carlo simulations. The density of the amorphous films determined from the experimental data agreed with MD calculations. Coordination numbers, bond lengths, and distortion for metal–oxygen and for both the edge- and corner-shared In–metal shells up to 4.5 Å obtained from PDF analysis closely agreed with MD and EPSR simulations. There is a pronounced decrease in the edge- and corner-shared In–Zn distances arising from the shorter Zn–O bond length, Zn–O tetrahedral coordination, and In–O–Zn angle in amorphous ZITO compared to its crystalline counterpart. A maximum in electrical mobility was observed for the amorphous film just before crystallization occurred. While the peak is broad, consistent with nearly unchanged overall cation–oxygen coordination in the amorphous films, ESPR results indicate that the tetrahedral coordination follows the conductivity trend.

Grazing Incidence X-ray↗

SU-E-T-524: In-Vivo Diode Dosimetry Proton Therapy Range Verification Validation Study for Pediatric CSI

Purpose: With the aim of reducing acute esophageal radiation toxicity in pediatric patients receiving craniospinal irradiation (CSI), we investigated the implementation of an in-vivo, adaptive proton therapy range verification methodology. Simulation experiments and in-phantom measurements were conducted to validate the range verification technique for this clinical application. Methods: A silicon diode array system has been developed and experimentally tested in phantom for passively scattered proton beam range verification for a prostate treatment case by correlating properties of the detector signal to the water equivalent path length (WEPL). We propose to extend the methodology to verify range distal to the vertebral body for pediatric CSI cases by placing this small volume dosimeter in the esophagus of the anesthetized patient immediately prior to treatment. A set of calibration measurements was performed to establish a time signal to WEPL fit for a “scout” beam in a solid water phantom. Measurements are compared against Monte Carlo simulation in GEANT4 using the Tool for Particle Simulation (TOPAS). Results: Measurements with the diode array in a spread out Bragg peak of 14 cm modulation width and 15 cm range (177 MeV passively scattered beam) in solid water were successfully validated against proton fluence rate simulations in TOPAS. The resulting calibration curve allows for a sensitivity analysis of detector system response with dose rate in simulation and with individual diode position through simulation on patient CT data. Conclusion: Feasibility has been shown for the application of this range verification methodology to pediatric CSI. An in-vivo measurement to determine the WEPL to the inner surface of the esophagus will allow for personalized adjustment of the treatment plan to ensure sparing of the esophagus while confirming target coverage. A Toltz acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290)

60 APPLIED LIFE SCIENCES↗

Advances in Performance of Microchannel Plate Detectors for HEDP Diagnostics

In recent years, a team from NSTec and SNL has built a unique capability to develop microchannel plate (MCP)?based framing x-ray cameras for HEDP diagnostics. At the SNL Z facility, multistrip MCP detectors to record up to eight channels are employed in 2-D, sub-nanosecond time-resolved imaging and time- and space-resolved spectroscopy diagnostics. Progressively more stringent technical temporal resolution and response uniformity requirements have necessitated a systematic design approach based on iterative modeling of the MCP using inputs from electrical circuit characterization. An inherently large exponential dependence in MCP gain, V{sup 11.5}, has mandated a firm understanding of the applied voltage pulse shape propagating across the strip. We pioneered direct measurements of the propagating waveform using a Picoprobe{reg_sign} and developed a Monte Carlo code to simulate MCP response to compare against test measurements. This scheme is shown in Figure 1. The simulation detailed a physical model of the cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Using this design approach, we began to characterize the newly developed second-generation detector (H-CA-65) by using a Manson x-ray source to evaluate the following DC characteristics: MCP sensitivity as a function of bias voltage, flat-field uniformity and spatial resolution, and variation of spatial resolution and sensitivity as a function of phosphor bias voltage. Dynamic performance and temporal response were obtained by using an NSTec short-pulse laser to measure optical gate profiles, saturation, and dynamic range. These data were processed and combined to obtain the gain variation and gate profiles for any position along an MCP strip. Typical position-sensitive gate profiles of the detector are shown in Figure 2. The measured gate profiles for the latest design have shown excellent agreement with Monte Carlo simulations. This modeling success provides us with a powerful tool for designing and optimizing MCP detectors that will meet specified requirements. For example, the pulse-forming network (PFN) pulse width can be chosen based on Monte Carlo simulation to achieve the shortest gate profiles without loss of significant gain. In Figure 2, a 150-ps FWHM gate profile was determined to be the inherent response time of our detector, This is close to the transit time of the electrons inside the MCP. The difference between design and measured performance of the H-CA-65 is within experimental errors. The most exciting outcome from the characterize/model process is that MCP gain uniformity can be achieved by adjusting output circuit impedance and judiciously selecting an appropriately wide voltage pulse waveform to drive the MCP strip. The combination of impedance, reflection ratio, and pulse shape/width can be optimized to provide a uniform pulse to propagate across a strip. Figure 3 shows the sensitivity measured across an MCP strip for an old-style SNL detector and the H-CA-65. The H-CA-65's uniformity is 30% or better for a strip driven by a 300-ps FWHM PFN (yielding a 150-ps FWHM optical gate profile), compared to a factor of five or less for the old detector. For the time-resolved spectroscopy diagnostic at Z, gain uniformity across the strip is a much more critical criterion than a narrow optical gate. A gain uniformity of 10% along the MCP strip was achieved when driven by a 700-ps FWHM PFN (yielding a 250-ps FWHM optical gate), a two order of magnitude improvement. The developments that produced the H-CA-65, which are now part of our MCP design process, have reduced product cost and the time it takes to develop and characterize the new MCP detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a CMOS SOI Pixel Detector

We have developed a monolithic radiation pixel detector using silicon on insulator (SOI) with a commercial 0.15 {micro}m fully-depleted-SOI technology and a Czochralski high resistivity silicon substrate in place of a handle wafer. The SOI TEG (Test Element Group) chips with a size of 2.5 x 2.5 mm{sup 2} consisting of 20 x 20 {micro}m{sup 2} pixels have been designed and manufactured. Performance tests with a laser light illumination and a {beta} ray radioactive source indicate successful operation of the detector. We also briefly discuss the back gate effect as well as the simulation study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of the Charge Measurements for the SuperCDMS Soudan Experiment

Astronomical observations lead us to believe that dark matter constitutes the majority of the mass of the Universe, yet it has never been directly observed experimentally. The Super Cryogenic Dark Matter Search Experiment (SuperCDMS) aims to discover the particle nature of dark matter, by developing and using some of the most sensitive detectors ever built. The SuperCDMS detectors are capable of rejecting known particles to search for dark matter interactions, but the discrimination is a complicated analysis task. Previous analyses with SuperCDMS set world leading sensitivity limits to dark matter interactions, but the analysis techniques have not been based on simulations. Now we have developed an efficient simulations infrastructure that will help better understand the detectors, develop a better background model, and optimize the next generation dark matter searches. In this thesis we present the fully-functional simulations infrastructure to produce high quality samples a s well as results for the charge system readout simulations, and comparisons to expectations from data. We show that our simulations well-reproduce dominant features of data, bringing SuperCDMS closer to a robust simulation-based analysis method, much needed for the upcoming SuperCDMS dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measured and simulated Cf ( sf ) 252 prompt neutron-photon competition

We present that neutrons and photons are characteristically emitted during the nuclear fission process when a deformed, neutron-rich nucleus divides into two fragments that then deexcite. During deexcitation, neutrons are emitted first, followed by photons; this process gives rise to correlated emissions. Few data exist on event-by-event neutron-photon correlation. In this work, Cf ( sf ) 252 neutron and photon correlations were measured with an array of 45 liquid organic scintillation detectors and a fission chamber. The measured correlations are compared with MCPNX-PoliMi simulations using the built-in model and two event-by-event fission models, CGMF and FREYA, which predict correlations in prompt emissions from fission. Lastly, experimental results suggest weak neutron-photon competition during fragment deexcitation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Smart pixel sensors: towards on-sensor filtering of pixel clusters with deep learning

Highly granular pixel detectors allow for increasingly precise measurements of charged particle tracks. Next-generation detectors require that pixel sizes will be further reduced, leading to unprecedented data rates exceeding those foreseen at the High- Luminosity Large Hadron Collider. Signal processing that handles data incoming at a rate of $\mathcal{O}$(40 MHz) and intelligently reduces the data within the pixelated region of the detector at rate will enhance physics performance at high luminosity and enable physics analyses that are not currently possible. Using the shape of charge clusters deposited in an array of small pixels, the physical properties of the traversing particle can be extracted with locally customized neural networks. In this first demonstration, we present a neural network that can be embedded into the on-sensor readout and filter out hits from low momentum tracks, reducing the detector's data volume by 57.1%–75.7%. The network is designed and simulated as a custom readout integrated circuit with 28 nm CMOS technology and is expected to operate at less than 300 μW with an area of less than 0.2 mm 2 . The temporal development of charge clusters is investigated to demonstrate possible future performance gains, and there is also a discussion of future algorithmic and technological improvements that could enhance efficiency, data reduction, and power per area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate effective-one-body waveforms of inspiralling and coalescing black-hole binaries

The effective-one-body (EOB) formalism contains several flexibility parameters, notably a{sub 5}, v{sub pole}, and a{sub RR}. We show here how to jointly constrain the values of these parameters by simultaneously best-fitting the EOB waveform to two, independent, numerical relativity (NR) simulations of inspiralling and/or coalescing binary black-hole systems: published Caltech-Cornell inspiral data (considered for gravitational wave frequencies M{omega}{<=}0.1) on one side, and newly computed coalescence data on the other side. The resulting, approximately unique, 'best-fit' EOB waveform is then shown to exhibit excellent agreement with NR coalescence data for several mass ratios. The dephasing between this best-fit EOB waveform and published Caltech-Cornell inspiral data is found to vary between -0.0014 and +0.0008 radians over a time span of {approx}2464M up to gravitational wave frequency M{omega}=0.1, and between +0.0013 and -0.0185 over a time span of 96M after M{omega}=0.1 up to M{omega}=0.1565. The dephasings between EOB and the new coalescence data are found to be smaller than: (i) {+-}0.025 radians over a time span of 730M (11 cycles) up to merger, in the equal-mass case, and (ii) {+-}0.05 radians over a time span of about 950M (17 cycles) up to merger in the 2 ratio 1 mass-ratio case. These new results corroborate the aptitude of the EOB formalism to provide accurate representations of general relativistic waveforms, which are needed by currently operating gravitational wave detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Benchmark study of TRIPOLI-4 through experiment and MCNP codes

Reliability on simulation results is essential in nuclear physics. Although MCNP5 and MCNPX are the world widely used 3D Monte Carlo radiation transport codes, alternative Monte Carlo simulation tools exist to simulate neutral and charged particles' interactions with matter. Therefore, benchmark are required in order to validate these simulation codes. For instance, TRIPOLI-4.7, developed at the French Alternative Energies and Atomic Energy Commission for neutron and photon transport, now also provides the user with a full feature electron-photon electromagnetic shower. Whereas the reliability of TRIPOLI-4.7 for neutron and photon transport has been validated yet, the new development regarding electron-photon matter interaction needs additional validation benchmarks. We will thus demonstrate how accurately TRIPOLI-4's 'deposited spectrum' tally can simulate gamma spectrometry problems, compared to MCNP's 'F8' tally. The experimental setup is based on an HPGe detector measuring the decay spectrum of an {sup 152}Eu source. These results are then compared with those given by MCNPX 2.6d and TRIPOLI-4 codes. This paper deals with both the experimental aspect and simulation. We will demonstrate that TRIPOLI-4 is a potential alternative to both MCNPX and MCNP5 for gamma-electron interaction simulation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of low-mode shape control in indirect-drive double shell implosions at the NIF

Double shell inertial confinement fusion is a concept for achieving robust thermonuclear burn that uses dense metal shells to compress deuterium-tritium (DT) fuel to fusion conditions. Double shell implosions are typically indirectly driven and involve a target that consists of a low-Z ablator, a foam layer, and a high-Z pusher surrounding the DT fuel. The goal of the campaign is to achieve a volumetric burn as radiation losses from the DT fuel are trapped by the opaque high-Z shell. The overall performance of double shell implosions relies on the efficient collisional transfer of kinetic energy between layers. The efficiency of this transfer (and therefore the overall performance of a given implosion) is degraded by the presence of low-mode asymmetries. P2 asymmetries are often observed in spatially resolved 2D radiographs of nominal double shell implosions. This work discusses three such experiments: one with an oblate P2 asymmetry, one with a prolate P2 asymmetry, and one with an approximate spherical symmetry. After performing a shape analysis of the oblate and prolate implosions to quantify asymmetries, these experimental results were compared with the results of hydrodynamic simulations for the two experiments. Differences between the experiment and simulation were then used to design an approximately spherical implosion by altering the incident laser cone fraction. Radiographs from the experiment that implemented the modified cone fraction show evidence of an implosion that is approximately spherical until bang time. This design is intended to serve as a point design for future studies that will seek to optimize various aspects of the double shell target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DUAL-PARTICLE DOSEMETER BASED ON ORGANIC SCINTILLATOR

Abstract Traditionally available handheld dosemeters are generally sensitive to only one type of radiation: neutrons or photons. Some dosemeters also rely on very specific attenuation correlations between response and dose, are not scalable in size and multiple dosemeters are required to characterise mixed-particle fields. The research presented here serves as a proof-of-concept for a method to simultaneously measure dose rates from neutrons and photons using a particle discriminating organic scintillation detector without the need for spectral deconvolution. The method was compared with traditional instruments and to simulation. Isotopic photon dose rates measured with this method were within 4% of simulated truth, whereas fission spectrum neutron dose rates were measured within 21%. Measurements of dose rates from both particles agree with simulated truth better than traditional instruments. This new method allows for measurement of dose equivalent from both neutrons and photons with a single instrument and no reliance on spectral deconvolution.

Miller, C. A.↗

Muon Radiography with the NOvA Near Detector

Information on the geological and man-made structures, directly contributing to the overburden of the NOvA Near Detector, located 100 m underground at Fermilab, are extracted from the cosmic muon data accumulated in the period April 2015 - October 2016. Results of this radiographic analysis of cosmic data are obtained by exploiting the acceptance symmetries of the NOvA detector. Radiographic maps of the overburden variations are acquired without subtracting the surface muon flux (free sky data) and without MC simulation of the cosmic muons attenuation in the homogeneous and flat overburden. By directly subtracting the angular muon track data measured by the NOvA Near Detector, arriving from directions having the same attenuation length (in the flat-surface approximation) and belonging to the acceptance regions with the same reconstruction efficiency, one can efficiently obtain two-dimensional differential radiographic maps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signal processing in the neutral-trigger system of the CMD-3 detector

A method for calorimeter-signal processing intended for deriving input signals for the neutral trigger is considered. An algorithm for digitizing signals is described in detail, along with a simulation of its operation. A brief account of data obtained in tests of a prototype of the signal-processing module that employs the developed algorithm is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional reconstruction of inertial confinement fusion hot-spot plasma from x-ray and nuclear diagnostics on OMEGA

Multidimensional effects degrade the neutron yield and the compressed areal density of laser-direct-drive inertial confinement fusion implosions of layered deuterium–tritium cryogenic targets on the OMEGA Laser System with respect to 1D radiation-hydrodynamic simulation predictions. A comprehensive physics-informed 3D reconstruction effort is under way to infer hot-spot and shell conditions at stagnation from four x-ray and seven neutron detectors distributed around the OMEGA target chamber. Neutron diagnostics, providing measurements of the neutron yield, hot-spot flow velocity, and apparent ion-temperature distribution, are used to infer the mode-1 perturbation at stagnation. The x-ray imagers record the shape of the hot-spot plasma to diagnose mode-1 and mode-2 perturbations. A deep-learning convolutional neural network trained on an extensive set of 3D radiation-hydrodynamic simulations is used to interpret the x-ray and nuclear measurements to infer the 3D profiles of the hot-spot plasma conditions and the amount of laser energy coupled to the hot-spot plasma. A 3D simulation database shows that larger mode-1 asymmetries are correlated with higher hot-spot flow velocities and reduced laser-energy coupling and neutron yield. Three-dimensional hot-spot reconstructions from x-ray measurements indicate that higher amounts of residual kinetic energy are correlated with higher measured hot-spot flow velocities, consistent with 3D simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gravitational-wave stochastic background from kinks and cusps on cosmic strings

We compute the contribution of kinks on cosmic string loops to stochastic background of gravitational waves (SBGW). We find that kinks contribute at the same order as cusps to the SBGW. We discuss the accessibility of the total background due to kinks as well as cusps to current and planned gravitational-wave detectors, as well as to the big bang nucleosynthesis (BBN), the cosmic microwave background (CMB), and pulsar timing constraints. As in the case of cusps, we find that current data from interferometric gravitational-wave detectors, such as LIGO, are sensitive to areas of parameter space of cosmic string models complementary to those accessible to pulsar, BBN, and CMB bounds.