Machine Learning and Turbulent Flows: Learning from Turbulence Simulation Data Sets.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Polyurethane foams are used widely for encapsulation and structural purposes because they are inexpensive, straightforward to process, amenable to a wide range of density variations (1 lb/ft3 - 50 lb/ft3), and able to fill complex molds quickly and effectively. Computational model of the filling and curing process are needed to reduce defects such as voids, out-of-specification density, density gradients, foam decomposition from high temperatures due to exotherms, and incomplete filling. This paper details the development of a computational fluid dynamics model of a moderate density PMDI structural foam, PMDI-10. PMDI is an isocyanate-based polyurethane foam, which is chemically blown with water. The polyol reacts with isocyanate to produces the polymer. PMDI- 10 is catalyzed giving it a short pot life: it foams and polymerizes to a solid within 5 minutes during normal processing. To achieve a higher density, the foam is over-packed to twice or more of its free rise density of 10 lb/ft3. The goal for modeling is to represent the expansion, filling of molds, and the polymerization of the foam. This will be used to reduce defects, optimize the mold design, troubleshoot the processed, and predict the final foam properties. A homogenized continuum model foaming and curing was developed based on reaction kinetics, documented in a recent paper; it uses a simplified mathematical formalism that decouples these two reactions. The chemo-rheology of PMDI is measured experimentally and fit to a generalized- Newtonian viscosity model that is dependent on the extent of cure, gas fraction, and temperature. The conservation equations, including the equations of motion, an energy balance, and three rate equations are solved via a stabilized finite element method. The equations are combined with a level set method to determine the location of the foam-gas interface as it evolves to fill the mold. Understanding the thermal history and loads on the foam due to exothermicity and oven curing is very important to the results, since the kinetics, viscosity, and other material properties are all sensitive to temperature. Results from the model are compared to experimental flow visualization data and post-test X-ray computed tomography (CT) data for the density. Several geometries are investigated including two configurations of a mock structural part and a bar geometry to specifically test the density model. We have found that the model predicts both average density and filling profiles well. However, it under predicts density gradients, especially in the gravity direction. Further model improvements are also discussed for future work.
Abstract not provided.
Membrane Ionic Liquid Desiccant Air Dehumidification (MILDAD) is a promising alternative to conventional dehumidification systems that employ mechanical compressors and refrigerant-based cooling with evaporator and condensing coils. However, its application has been limited due to high manufacturing and installation cost, durability issues, concerns with corrosion due to leakage and salt carry over into the downstream air and onto surfaces. This paper reviews substantial progress made with new systems based on combining advanced ionic membranes that are pressure resistant, thin walled with high water permeability, and non-porous with synthetic organic, non-crystalline ionic liquid desiccants. Alternative design configurations are discussed comparing cross flow shell-and-tube membrane contactors employing ionic membrane tubes through which ionic liquid desiccant air flows. Performance data for MILDAD prototypes is provided. Dehumidification of the incoming supply airstream and regeneration into exhausted building air is demonstrated. The latent effectiveness of the MILDAD system will be discussed along with some future steps to improve performance of the system.
The accompanying poster to this short paper presents a combination of reverse mode AD and formal methods to enable efficient differentiation of (or backpropagation through) shared-memory parallel code. Compared to the state of the art, our approach can more often avoid the need for atomic updates or private data copies during the parallel derivative computation, even in the presence of unstructured or data-dependent data access patterns. This is achieved by gathering information about the memory access patterns from the input program, which is assumed to be correctly parallelized. This information is then used to build a model of assertions in a theorem prover, which can be used to check the safety of shared memory accesses during the parallel derivative computation
Membrane Ionic Liquid Desiccant Air Dehumidification (MILDAD) is a promising alternative to conventional dehumidification systems that employ mechanical compressors and refrigerant-based cooling with evaporator and condensing coils. However, its application has been limited due to high manufacturing and installation cost, durability issues, concerns with corrosion due to leakage and salt carry over into the downstream air and onto surfaces. This paper reviews substantial progress made with new systems based on combining advanced ionic membranes that are pressure resistant, thin walled with high water permeability, and non-porous with synthetic organic, non-crystalline ionic liquid desiccants. Alternative design configurations are discussed comparing cross flow shell-and-tube membrane contactors employing ionic membrane tubes through which ionic liquid desiccant air flows. Performance data for MILDAD prototypes is provided. Dehumidification of the incoming supply airstream and regeneration into exhausted building air is demonstrated. The latent effectiveness of the MILDAD system will be discussed along with some future steps to improve performance of the system.
Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.
This is a report that provides the test bed design for the DOE-SETO SolarSTARTS project as a milestone.
This poster describes a typing discipline for high-assurance industrial systems based on three novel type systems. The first type system, information flow control (IFC), controls the flow of data through the system. The second system, dependent session types, restricts messages exchanged during the execution of a communication protocol to avoid dangerous states. The third system uses dimensional analysis to avoid subtle bugs that adversaries can exploit to cause the system to enter a dangerous state. This poster describes how a combination of these approaches can prevent sophisticated cyber attacks, such as the infamous Stuxnet incident, from occurring. In addition, we provide experimental evidence to support the claim that these approaches can be applied in control systems that are resource-constrained.
Characterization of off-gas constituents from nuclear fuel reprocessing can be measured using a residual gas analyzer. Characterization of this off-gas is important in a closed fuel cycle, where gasses such as Nox, Kr, I, and C-14 need to be removed from reprocessing plants to meet regulatory requirements. Both Kr and Xe have low chemical reactivity, making capture and separation difficult. Solid sorbents can be used to capture these gases as an alternative to cryogenic distillation, which is energy intensive and hazardous. AgZ-PAN and HZ-PAN are two solid sorbents that have demonstrated selective capture of Xe and Kr. A residual gas analyzer can be used to obtain breakthrough curves that demonstrate how well this adsorption and separation occur. The breakthrough curve is dependent on packing density, column size, and flow rate. Data obtained from the RGA was verified with a gas chromatographer.
Proposed space applications, such as the cooling of infrared and x ray telescopes, have generated substantial interest in the behavior of He(2) flowing in porous materials. For design purposes, classical porous media correlations and room temperature data are often used to obtain order of magnitude estimates of expected pressure drops, while the attendant temperature differences are either ignored or estimated using smooth tube correlations. A more accurate alternative to this procedure is suggested by an empirical extension of the two fluid models. It is shown that four empirical parameters are necessary to describe the pressure and temperature differences induced by He(2) flow through a porous sample. The three parameters required to determine pressure differences are measured in counterflow and found to compare favorably with those for isothermal flow. The fourth parameter, the Gorter-Mellink constant, differs substantially from smooth tube values. It is concluded that parameter values determined from counterflow can be used to predict pressure and temperature differences in a variety of flows to an accuracy of about + or - 20 percent.
Proposed space applications, such as the cooling of infrared and x ray telescopes, have generated substantial interest in the behavior of He II flowing in porous materials. For design purposes, classical porous media correlations and room temperature data are often used to obtain order of magnitude estimates of expected pressure drops, while the attendant temperature differences are either ignored or estimated using smooth tube correlations. A more accurate alternative to this procedure is suggested by an empirical extension of the two fluid model. It is shown that four empirical parameters are necessary to describe the pressure and temperature differences induced by He II flow through a porous sample. The three parameters required to determine pressure differences are measured in counterflow and found to compare favorably with those for isothermal flow. The fourth parameter, the Gorter-Mellink constant, differs substantially from smooth tube values. It is concluded that parameter values determined from counterflow can be used to predict pressure and temperature differences in a variety of flows to an accuracy of about + or - 20 pct.
These data support the manuscript “Acquisitive root exploration strategies help maintain higher peak sap flux rates during summer drought, but more root biomass does not”. The dataset includes processed sap flow measurements and fine-root trait data collected between 2019 and 2021 from temperate monodominant tree plots established in the 1920s to 1930s ranging in size from 0.05 to 0.8 ha at The Morton Arboretum in Lisle, IL. Sap flow was measured with ICT sap flow sensors using the heat ratio method. Fine-root traits were measured from soil cores which includes specific root length (SRL), specific root area (SRA), diameter, biomass, and length for diameter classes ≤1 mm and ≤2 mm. The package contains comma separated value (CSV) data files and associated metadata that can be viewed and analyzed using common software such as spreadsheet programs, R, and Python. These data are used to investigate how variation in fine-root traits relate to tree water use and drought response during summer drought linking belowground root traits and aboveground physiological responses.
Tests were conducted for an air-water flow through two sudden contractions aboard the NASA DC-9 low gravity aircraft. Flow rate, residual accelerations, void fraction, film thickness, and pressure drop data were recorded and flow visualization at 250 images per second were recorded. Some preliminary results based on the flow visualization data are presented for bubbly, slug and annular flow.
In internally mixed exhaust systems, a lobed or forced mixer is employed to mix the core and bypass streams before they exit the common nozzle. For moderate bypass-ratio engines this marginally improves thrust, and provides a significant acoustic benefit. Indeed, it has been thought that a fully mixed jet creates the lowest noise you can get from a two-stream engine. Typically, the forced mixer system produces a bit more noise than a fully mixed equivalent jet, noise that has been called “excess noise”. In recent testing, this excess noise seemed to be amplified when an external plug was employed in the exhaust system to reduce boattail drag. Identifying the mechanism of this excess noise and mitigating it is key to creating commercial supersonic vehicles that are acoustically acceptable around airports. This paper adds to that investigation, analyzing results from recent tests where far-field acoustic data were acquired on two sets of flows with matched fully mixed flow conditions. One set of flows had a heated core stream, making it a dual-stream jet. The other set had both streams heated to the same temperature, making a single-stream jet that matched the fully mixed temperature and velocity of the dual-stream jet. These flows were tested in two lobed-mixer exhaust systems with internal and external plugs. Analysis of flow and noise data from the nozzles with combinations of single- and dual-stream flows, and with and without flight streams, gives insight into how and why the noise of the dual-stream and single-stream jet differ. One additive source, present in nozzles both with and without external plugs, comes from inside the nozzle, likely the internal shear layer coming off the lobed mixer. This noise source is not impacted by a change in flight stream and has a distinctive spectral directivity that is amplified by the presence of the external plug. Finding the exact source mechanism of this new source will be key to making the internally mixed exhaust systems reach their lowest possible sound level.
In internally mixed exhaust systems, a lobed or forced mixer is employed to mix the core and bypass streams before they exit the common nozzle. For moderate bypass-ratio engines this marginally improves thrust, and provides a significant acoustic benefit. Indeed, it has been thought that a fully mixed jet creates the lowest noise you can get from a two-stream engine. Typically, the forced mixer system produces a bit more noise than a fully mixed equivalent jet, noise that has been called “excess noise”. In recent testing, this excess noise seemed to be amplified when an external plug was employed in the exhaust system to reduce boattail drag. Identifying the mechanism of this excess noise and mitigating it is key to creating commercial supersonic vehicles that are acoustically acceptable around airports. This paper adds to that investigation, analyzing results from recent tests where far-field acoustic data were acquired on two sets of flows with matched fully mixed flow conditions. One set of flows had a heated core stream, making it a dual-stream jet. The other set had both streams heated to the same temperature, making a single-stream jet that matched the fully mixed temperature and velocity of the dual-stream jet. These flows were tested in two lobed-mixer exhaust systems with internal and external plugs. Analysis of flow and noise data from the nozzles with combinations of single- and dual-stream flows, and with and without flight streams, gives insight into how and why the noise of the dual-stream and single-stream jet differ. One additive source, present in nozzles both with and without external plugs, comes from inside the nozzle, likely the internal shear layer coming off the lobed mixer. This noise source is not impacted by a change in flight stream and has a distinctive spectral directivity that is amplified by the presence of the external plug. Finding the exact source mechanism of this new source will be key to making the internally mixed exhaust systems reach their lowest possible sound level.
These slides were prepared for a meeting with Department of Nuclear Engineering at NCSU. This meeting was held to discuss collaborations about machine learning applications for system thermal hydraulic simulations.
A hypersonic wind tunnel test method for obtaining credible aerodynamic data on a complete hypersonic vehicle (generic X-24c) with scramjet exhaust flow simulation is described. The general problems of simulating the scramjet exhaust as well as accounting for scramjet inlet flow and vehicle forces are analyzed, and candidate test methods are described and compared. The method selected as most useful makes use of a thrust-minus-drag flow-through balance with a completely metric model. Inlet flow is diverted by a fairing. The incremental effect of the fairing is determined in the testing of two reference models. The net thrust of the scramjet module is an input to be determined in large-scale module tests with scramjet combustion. Force accounting is described, and examples of force component levels are predicted. Compatibility of the test method with candidate wind tunnel facilities is described, and a preliminary model mechanical arrangement drawing is presented. The balance design and performance requirements are described in a detailed specification. Calibration procedures, model instrumentation, and a test plan for the model are outlined.