Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction

This paper presents a new reconstruction algorithm for both single- and dual-energy computed tomography (CT) imaging. By incorporating the polychromatic characteristics of the X-ray beam into the reconstruction process, the algorithm is capable of eliminating beam hardening artifacts. The single energy version of the algorithm assumes that each voxel in the scan field can be expressed as a mixture of two known substances, for example, a mixture of trabecular bone and marrow, or a mixture of fat and flesh. These assumptions are easily satisfied in a quantitative computed tomography (QCT) setting. We have compared our algorithm to three commonly used single-energy correction techniques. Experimental results show that our algorithm is much more robust and accurate. We have also shown that QCT measurements obtained using our algorithm are five times more accurate than that from current QCT systems (using calibration). The dual-energy mode does not require any prior knowledge of the object in the scan field, and can be used to estimate the attenuation coefficient function of unknown materials. We have tested the dual-energy setup to obtain an accurate estimate for the attenuation coefficient function of K2 HPO4 solution.

NASA Center ARC↗

Reduction of the elevator illusion from continued hypergravity exposure and visual error-corrective feedback

Ten subjects served as their own controls in two conditions of continuous, centrifugally produced hypergravity (+2 Gz) and a 1-G control condition. Before and after exposure, open-loop measures were obtained of (1) motor control, (2) visual localization, and (3) hand-eye coordination. During exposure in the visual feedback/hypergravity condition, subjects received terminal visual error-corrective feedback from their target pointing, and in the no-visual feedback/hypergravity condition they pointed open loop. As expected, the motor control measures for both experimental conditions revealed very short lived underreaching (the muscle-loading effect) at the outset of hypergravity and an equally transient negative aftereffect on returning to 1 G. The substantial (approximately 17 degrees) initial elevator illusion experienced in both hypergravity conditions declined over the course of the exposure period, whether or not visual feedback was provided. This effect was tentatively attributed to habituation of the otoliths. Visual feedback produced a smaller additional decrement and a postexposure negative after-effect, possible evidence for visual recalibration. Surprisingly, the target-pointing error made during hypergravity in the no-visual-feedback condition was substantially less than that predicted by subjects' elevator illusion. This finding calls into question the neural outflow model as a complete explanation of this illusion.

NASA Program Space Physiology and Countermeasures↗

Undersampling Correction for Array Detector-Based Satellite Spectrometers

Array detector-based instruments are now fundamental to measurements of ozone and other atmospheric trace gases from space in the ultraviolet, visible, and infrared. The present generation of such instruments suffers, to a greater or lesser degree, from undersampling of the spectra, leading to difficulties in the analysis of atmospheric radiances. We provide extended analysis of the undersampling suffered by modem satellite spectrometers, which include Global Ozone Monitoring Experiment (GOME), Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY), Ozone Monitoring Instrument (OMI), and Ozone Mapping and Profiler Suite (OMPS). The analysis includes basic undersampling, the effects of binning into separate detector pixels, and the application of high-resolution Fraunhofer spectral data to correct for undersampling in many useful cases.

Chance, Kelly↗

A Posteriori Correction of Forecast and Observation Error Variances

Proposed method of total observation and forecast error variance correction is based on the assumption about normal distribution of "observed-minus-forecast" residuals (O-F), where O is an observed value and F is usually a short-term model forecast. This assumption can be accepted for several types of observations (except humidity) which are not grossly in error. Degree of nearness to normal distribution can be estimated by the symmetry or skewness (luck of symmetry) a(sub 3) = mu(sub 3)/sigma(sup 3) and kurtosis a(sub 4) = mu(sub 4)/sigma(sup 4) - 3 Here mu(sub i) = i-order moment, sigma is a standard deviation. It is well known that for normal distribution a(sub 3) = a(sub 4) = 0.

Rukhovets, Leonid↗

Retrieval of Marine Water Constituents Using Atmospherically Corrected AVIRIS Hyperspectral Data

This paper reports on the validation of bio-optical models in estuarine and nearshore (case 2) waters of New Jersey-New York to retrieve accurate water-leaving radiance spectra and chlorophyll concentration from the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) imaging spectrometer data. MODTRAN-4 was applied to remove the effects of the atmosphere so as to infer the water-leaving radiance. The study area - Hudson/Raritan of New York and New Jersey (Figure 1) is an extremely complex estuarine system where tidal and wind-driven currents are modified by freshwater discharges from the Hudson, Raritan, Hackensack, and Passaic rivers. Over the last century, the estuarine water quality has degraded in part due to eutrophication, which has disrupted the preexisting natural balance, resulting in phytoplankton blooms of both increased frequency and intensity, increasing oxygen demand, and leading to episodes of hypoxia. As the end result, a thematic map of chlorophyll-a concentration was generated using an atmospherically corrected AVIRIS ratio image. This thematic map serves as an indication of phytoplankton concentration. Such maps are important input into the geographic information system (GIS) for use as a management tool for monitoring water resources.

Bagheri, Sima↗

A Correction for the IRI Topside Electron Density Model Based on Alouette/ISIS Topside Sounder Data

The topside segment of the International Reference Ionosphere (IRI) electron density model (and also of the Bent model) is based on the limited amount of topside data available at the time (40,OOO Alouette 1 profiles). Being established from such a small database it is therefore not surprising that the models have well-known shortcomings, for example, at high solar activities. Meanwhile a large data base of close to 200,000 topside profiles from Alouette 1,2, and ISIS I, 2 has become available online. A program of automated scaling and inversion of a large volume of digitized ionograms adds continuously to this data pool. We have used the currently available ISIs/Alouette topside profiles to evaluate the IRI topside model and to investigate ways of improving the model. The IRI model performs generally well at middle latitudes and shows discrepancies at low and high latitudes and these discrepancies are largest during high solar activity. In the upper topside IRI consistently overestimates the measurements. Based on averages of the data-model ratios we have established correction factors for the IRI model. These factors vary with altitude, modified dip latitude, and local time.

Bilitza, D.↗

Historical Precision of an Ozone Correction Procedure for AM0 Solar Cell Calibration

In an effort to improve the accuracy of the high altitude aircraft method for calibration of high band-gap solar cells, the ozone correction procedure has been revisited. The new procedure adjusts the measured short circuit current, Isc, according to satellite based ozone measurements and a model of the atmospheric ozone profile then extrapolates the measurements to air mass zero, AMO. The purpose of this paper is to assess the precision of the revised procedure by applying it to historical data sets. The average Isc of a silicon cell for a flying season increased 0.5% and the standard deviation improved from 0.5% to 0.3%. The 12 year average Isc of a GaAs cell increased 1% and the standard deviation improved from 0.8% to 0.5%. The slight increase in measured Isc and improvement in standard deviation suggests that the accuracy of the aircraft method may improve from 1% to nearly 0.5%.

Snyder, David B.↗

Kinematic Characteristics of the Posture Corrective Responses After 6 Hours Exposure to Support Withdrawal Environment

Posture disorders are an inevitable consequence of exposure to microgravity . However, the role of different sensorimotor and sensory factors on postural function at different stages of the exposure to microgravity still remains unknown. The results obtained in a 6 hr dry immersion (DI) study where chest pushes served as a pre- and post-immersion perturbation, and DI was used as an analog of microgravity suggest that in addition to vestibular contributions, postural control may be related to a reduction of support loading and consequent decline of the tone of anti-gravitational muscles. Analysis of postural video data in response to chest pushes obtained before and after DI indicate that the structure of corrective responses was modified so that postural perturbations from threshold to moderate pushes showed a significant rise in the amplitude of ankle and knee angular displacement. With push intensity near the submaximal level, equilibrium was maintained by the elimination of excessive degrees of freedom; as manifested by the restriction of the hip joints mobility when coupled with a reduction of the knee and ankle displacement. These results suggest that DI increases the sensitivity of the posture control system by making posture control more rigid reflecting a change of the weight bearing receptors.

Sayenko D.↗

Open Microphone Speech Understanding: Correct Discrimination Of In Domain Speech

An ideal spoken dialogue system listens continually and determines which utterances were spoken to it, understands them and responds appropriately while ignoring the rest This paper outlines a simple method for achieving this goal which involves trading a slightly higher false rejection rate of in domain utterances for a higher correct rejection rate of Out of Domain (OOD) utterances. The system recognizes semantic entities specified by a unification grammar which is specialized by Explanation Based Learning (EBL). so that it only uses rules which are seen in the training data. The resulting grammar has probabilities assigned to each construct so that overgeneralizations are not a problem. The resulting system only recognizes utterances which reduce to a valid logical form which has meaning for the system and rejects the rest. A class N-gram grammar has been trained on the same training data. This system gives good recognition performance and offers good Out of Domain discrimination when combined with the semantic analysis. The resulting systems were tested on a Space Station Robot Dialogue Speech Database and a subset of the OGI conversational speech database. Both systems run in real time on a PC laptop and the present performance allows continuous listening with an acceptably low false acceptance rate. This type of open microphone system has been used in the Clarissa procedure reading and navigation spoken dialogue system which is being tested on the International Space Station.

Hieronymus, James↗

Long distance quantum communication using quantum error correction

We describe a quantum error correction scheme that can increase the effective absorption length of the communication channel. This device can play the role of a quantum transponder when placed in series, or a cyclic quantum memory when inserted in an optical loop.

quantum memory quantum repeater↗

Validation of Atmospheric Correction of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Radiance Data Based on Radiative Transfer Modeling

An evaluation of atmospheric correction of AVIRIS data using radiative transfer codes LOWTRAN7 and MODTRAN is presented. The algorithm employed is based on a simple model of radiance L at each wavelength at the sensor that can be written approximately LAV=Lp+Tp, where subscript AV referes to AVIRIS, Lp is the path radiance and Tp is the diffuse + direct transmitted radiance of the atmosphere at AVIRIS.

Infrared Mapping↗

TOPEX/POSEIDON Microwave Radiometer (TMR): III. Wet Troposphere Range Correction Algorithm and Pre-Launch Error Budget

The sole mission function of the TOPEX/POSEIDON Microwave Radiometer (TMR) is to provide corrections for the altimeter range errors induced by the highly variable atmospheric water vapor content. The three TMR frequencies are shown to be near-optimum for measuring the vapor-induced path delay within an environment of variable cloud cover and variable sea surface flux background. After a review of the underlying physics relevant to the prediction of 5-40 GHz nadir-viewing microwave brightness temperatures, we describe the development of the statistical, iterative algorithm used for the TMR retrieval of path delay. Test simulations are presented which demonstrate the uniformity of algorithm performance over a range of cloud liquid and sea surface wind speed conditions...

Keihm, S. J.↗