Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Impact of correlated data in validation procedures - 14483

The increasing demand on accuracy of criticality calculations leads to the question, how to treat correlated data of benchmark experiments correctly. Correlations in the process of validation arise for example if a configuration in a series of experiments shares certain components, e.g. fuel rods. Traditional methods of code validation do not treat correlations explicitly, but give a more conservative estimation of the bias. Including correlations can lead to a more precise estimation. In the work at hand, a method is discussed based on Bayes theorem to include correlations in the experimental data when estimating an application case k{sub eff}. After a short introduction to the applied method and the demonstration of the general capability of it to predict the k{sub eff} correctly, it is shown how the calculated k{sub eff} of an application case depends on correlations in experimental data for a simple Toy Model. The impact of ignoring correlations and taking to account lower and higher correlations is shown and discussed. Further results are shown using a database of correlated experimental data from the International Handbook of Criticality Safety Experiments to estimate the bias of two application cases. The experiments were chosen following the suggestion of the OECD/NEA EGUACSA Benchmark phase IV and consists of 21 experiments from the LEU-COMP-THERM series 007 and 039. With the extracted data results the calculated k{sub eff} values of the application cases are shown and discussed for different examples of correlations. The calculations were done by applying Monte-Carlo sampling methods with the GRS tool SUnCISTT, using ORNL's SCALE 6.1.2. This work discusses a possible way of treating correlations in the recalculation of critical experiments to get a more precise bias estimation of the used code system. It will be shown, that the presented method is capable to treat similarities in experimental setups of data used to calculate the bias correctly, independent of the size of similarities. The presented method is in principle capable of assessing regimes with little experimental data to estimate a bias. (authors)

42 ENGINEERING↗

Impact of PDF uncertainties at large x on heavy boson production

We explore the sensitivity of W and Z boson production in hadronic collisions to uncertainties in parton distribution functions (PDFs) at large x arising from uncertainties in nuclear corrections when using deuterium data in global QCD fits. The W and Z differential cross sections show increasing influence of nuclear corrections at high boson rapidities, particularly for the d quark, which is diluted somewhat in the decay lepton rapidity distributions. The effects of PDF uncertainties on heavy W' and Z' bosons beyond the Standard Model become progressively more important for larger boson masses or rapidities, both in p-p collisions at the LHC and in p-pbar scattering at the Tevatron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-Fidelity Learning for Distribution System Voltage Probabilistic Analysis with High Penetration of PVs

This paper proposes a multi-fidelity learning approach for distribution voltage probabilistic analysis with high penetration of PVs. Unlike the existing machine learning-based approaches that require a large number of high fidelity data to achieve satisfactory results, our approach strategically leverage massive low fidelity data from inaccurate model simulations and limited high fidelity historical data. The key idea is to use low-fidelity data to establish an initial model and then the high-fidelity data to calibrate and correct the constructed low-fidelity model. This allows us to fuse low- and high-fidelity data, yielding a high fidelity prediction model. Results obtained from a realistic feeder in US with 80% penetration of PVs show that the proposed approach can achieve a similar accuracy to the one with a large number of high fidelity data. This significantly highlights the advantages of the proposed method as compared to existing data-hungry machine learning methods. Different levels of fidelity data and their impacts are also investigated.

distribution system↗

Survey and Alignment Reference Data Generation and Deviation Reporting

The data used by survey group can be categorized into design data and measured data based on how it’s obtained. Design data is a simple term which refers to the ideal beam orbit which is given by physics group in the form of a series of coordinates in lattice frame. Comparatively, measured data is a complicated term which includes the fiducialization data of each component, girder integration data, girder profiling data and control network data etc. There are a lot of steps and techniques to make sure a precise and successful alignment. However, from pure data perspective, making up right reference data and reporting misalignment correctly are 2 keys of survey and alignment. The note will give an overview regarding how survey data will be generated and reported during key steps. More details should be checked in the referred documents or discussed specifically.

36 MATERIALS SCIENCE↗

Analysis Report for Determination of pH Correction Factors for Brines under AP-157 Rev.1

This Analysis Report (AR) documents the determination of pH correction factors for the observed pH readings. The correction factor converts the observed pH reading recorded from the brines used in geochemical studies in support of the Waste Isolation Pilot Plant (WIPP) to a corrected pH value. The data analysis in this AR falls under AP-157 Rev. 1 Analysis Plan for Determination of pH Correction Factors in Brines (Kirkes et al, 2021). Measurement of pH in some solutions can be challenging due to numerous factors such as high ionic strength, elevated or lowered temperature, complex matrix composition, etc. (Knauss et al., 1990; and Rai et al., 1995). The measured pH can be corrected by applying the correction factor, empirically obtained from a specific test solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Dynamics Explorer Langmuir probe instrument

The Dynamics Explorer Langmuir probe instrument (DE-LANG), a spare unit from the Pioneer Venus mission that has been modified to work with the DE spacecraft, is described. Two independent sensors are connected to individual adaptive sweep voltage circuits that continuously track the changing electron temperature and spacecraft potential while autoranging electrometers adjust their gain in response to the changing plasma density. The control signals used in achieving this automatic tracking provide a continuous monitor of the ionospheric parameters without telemetering each volt-ampere curve. In addition, internal data storage circuits permit high-resolution, high-data-rate sampling of selected volt-ampere curves for transmission to the ground to verify or correct the inflight processed data.

Krehbiel, J. P.↗

Assessing quality in cardiac surgery: why this is necessary in the twenty-first century

The cost and high-profile nature of coronary surgery means that this is an area of close public scrutiny. As much pioneering work in data collection and risk analyses has been carried out by cardiac surgeons, substantial information exists and the correct interpretation of that data is identified as an important issue. This paper considers the background and history of risk-adjustment in cardiac surgery, the uses of quality data, examines the observed/expected mortality ratio and looks at issues such as cost and reactions to outliers. The conclusion of the study is that the continuation of accurate data collection by the whole operative team and a strong commitment to constantly improving quality is crucial to its meaningful application.

Review↗

Livewire: Automatic Annotations

Diogenes processes datasets to provide data quality metrics for the Livewire platform and creates standardized data dictionaries from data annotations. Diogenes needs data annotations that clearly outline thenformat and organization of the data. It also relies on the type, class, and unit of each data piece for comprehensive analysis, which it cannot determine independently. The Annotation Tool significantly reduces the time needed to create annotations for Diogenes by generating data annotations with the correct formatting and content. It also employs machine learning and hard-coded models to automatically annotate data class, quality type, and data units.

33 - ADVANCED PROPULSION SYSTEMS↗

{sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms. Point spread function (PSF) correction and TOF reconstruction in general reduce background variability and noise and increase recovered concentration. Results for patient data indicated a good correlation between the expected and PET reconstructed activities. A linear relationship between the expected and the measured activities in the organ of interest was observed for all reconstruction method used: a linearity coefficient of 0.89 ± 0.05 for the Biograph mCT and 0.81 ± 0.05 for the Biograph TruePoint. Conclusions: Due to the low counts and high random fraction, accurate image quantification of {sup 90}Y during selective internal radionuclide therapy is affected by random coincidence estimation, scatter correction, and any positivity constraint of the algorithm. Nevertheless, phantom and patient studies showed that the impact of number of true and random coincidences on quantitative results was found to be limited as long as ordinary Poisson ordered subsets expectation maximization reconstruction algorithms with random smoothing are used. Adding PSF correction and TOF information to the reconstruction greatly improves the image quality in terms of bias, variability, noise reduction, and detectability. On the patient studies, the total activity in the field of view is in general accurately measured by Biograph mCT and slightly overestimated by the Biograph TruePoint.

60 APPLIED LIFE SCIENCES↗

Differential sea-state bias: A case study using TOPEX/POSEIDON data

We used selected data from the NASA altimeter TOPEX/POSEIDON to calculate differences in range measured by the C and Ku-band altimeters when the satellite overflew 5 to 15 m waves late at night. The range difference is due to free electrons in the ionosphere and to errors in sea-state bias. For the selected data the ionospheric influence on Ku range is less than 2 cm. Any difference in range over short horizontal distances is due only to a small along-track variability of the ionosphere and to errors in calculating the differential sea-state bias. We find that there is a barely detectable error in the bias in the geophysical data records. The wave-induced error in the ionospheric correction is less than 0.2% of significant wave height. The equivalent error in differential range is less than 1% of wave height. Errors in the differential sea-state bias calculations appear to be small even for extreme wave heights that greatly exceed the conditions on which the bias is based. The results also improved our confidence in the sea-state bias correction used for calculating the geophysical data records. Any error in the correction must influence Ku and C-band ranges almost equally.

Stewart, Robert H.↗

Effects of weather on the retrieval of sea ice concentration and ice type from passive microwave data

Effects of wind, water vapor, and cloud liquid water on ice concentration and ice type calculated from passive microwave data are assessed through radiative transfer calculations and observations. These weather effects can cause overestimates in ice concentration and more substantial underestimates in multi-year ice percentage by decreasing polarization and by decreasing the gradient between frequencies. The effect of surface temperature and air temperature on the magnitudes of weather-related errors is small for ice concentration and substantial for multiyear ice percentage. The existing weather filter in the NASA Team Algorithm addresses only weather effects over open ocean; the additional use of local open-ocean tie points and an alternative weather correction for the marginal ice zone can further reduce errors due to weather. Ice concentrations calculated using 37 versus 18 GHz data show little difference in total ice covered area, but greater differences in intermediate concentration classes. Given the magnitude of weather-related errors in ice classification from passive microwave data, corrections for weather effects may be necessary to detect small trends in ice covered area and ice type for climate studies.

Maslanik, J. A.↗

Expanding Lorentz and spectrum corrections to large volumes of reciprocal space for single-crystal time-of-flight neutron diffraction

Evidence is mounting that potentially exploitable properties of technologically and chemically interesting crystalline materials are often attributable to local structure effects, which can be observed as modulated diffuse scattering (mDS) next to Bragg diffraction (BD). BD forms a regular sparse grid of intense discrete points in reciprocal space. Traditionally, the intensity of each Bragg peak is extracted by integration of each individual reflection first, followed by application of the required corrections. In contrast, mDS is weak and covers expansive volumes of reciprocal space close to, or between, Bragg reflections. For a representative measurement of the diffuse scattering, multiple sample orientations are generally required, where many points in reciprocal space are measured multiple times and the resulting data are combined. The common post-integration data reduction method is not optimal with regard to counting statistics. A general and inclusive data processing method is needed. In this contribution, a comprehensive data analysis approach is introduced to correct and merge the full volume of scattering data in a single step, while correctly accounting for the statistical weight of the individual measurements. Development of this new approach required the exploration of a data treatment and correction protocol that includes the entire collected reciprocal space volume, using neutron time-of-flight or wavelength-resolved data collected at TOPAZ at the Spallation Neutron Source at Oak Ridge National Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise correlation in CBCT projection data and its application for noise reduction in low-dose CBCT

Purpose: To study the noise correlation properties of cone-beam CT (CBCT) projection data and to incorporate the noise correlation information to a statistics-based projection restoration algorithm for noise reduction in low-dose CBCT. Methods: In this study, the authors systematically investigated the noise correlation properties among detector bins of CBCT projection data by analyzing repeated projection measurements. The measurements were performed on a TrueBeam onboard CBCT imaging system with a 4030CB flat panel detector. An anthropomorphic male pelvis phantom was used to acquire 500 repeated projection data at six different dose levels from 0.1 to 1.6 mAs per projection at three fixed angles. To minimize the influence of the lag effect, lag correction was performed on the consecutively acquired projection data. The noise correlation coefficient between detector bin pairs was calculated from the corrected projection data. The noise correlation among CBCT projection data was then incorporated into the covariance matrix of the penalized weighted least-squares (PWLS) criterion for noise reduction of low-dose CBCT. Results: The analyses of the repeated measurements show that noise correlation coefficients are nonzero between the nearest neighboring bins of CBCT projection data. The average noise correlation coefficients for the first- and second-order neighbors are 0.20 and 0.06, respectively. The noise correlation coefficients are independent of the dose level. Reconstruction of the pelvis phantom shows that the PWLS criterion with consideration of noise correlation (PWLS-Cor) results in a lower noise level as compared to the PWLS criterion without considering the noise correlation (PWLS-Dia) at the matched resolution. At the 2.0 mm resolution level in the axial-plane noise resolution tradeoff analysis, the noise level of the PWLS-Cor reconstruction is 6.3% lower than that of the PWLS-Dia reconstruction. Conclusions: Noise is correlated among nearest neighboring detector bins of CBCT projection data. An accurate noise model of CBCT projection data can improve the performance of the statistics-based projection restoration algorithm for low-dose CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-A-18C-03: Noise Correlation in CBCT Projection Data and Its Application for Noise Reduction in Low-Dose CBCT

Purpose: To study the noise correlation properties of cone-beam CT (CBCT) projection data and to incorporate the noise correlation information to a statistics-based projection restoration algorithm for noise reduction in low-dose CBCT. Methods: In this study, we systematically investigated the noise correlation properties among detector bins of CBCT projection data by analyzing repeated projection measurements. The measurements were performed on a TrueBeam on-board CBCT imaging system with a 4030CB flat panel detector. An anthropomorphic male pelvis phantom was used to acquire 500 repeated projection data at six different dose levels from 0.1 mAs to 1.6 mAs per projection at three fixed angles. To minimize the influence of the lag effect, lag correction was performed on the consecutively acquired projection data. The noise correlation coefficient between detector bin pairs was calculated from the corrected projection data. The noise correlation among CBCT projection data was then incorporated into the covariance matrix of the penalized weighted least-squares (PWLS) criterion for noise reduction of low-dose CBCT. Results: The analyses of the repeated measurements show that noise correlation coefficients are non-zero between the nearest neighboring bins of CBCT projection data. The average noise correlation coefficients for the first- and second- order neighbors are about 0.20 and 0.06, respectively. The noise correlation coefficients are independent of the dose level. Reconstruction of the pelvis phantom shows that the PWLS criterion with consideration of noise correlation (PWLS-Cor) results in a lower noise level as compared to the PWLS criterion without considering the noise correlation (PWLS-Dia) at the matched resolution. Conclusion: Noise is correlated among nearest neighboring detector bins of CBCT projection data. An accurate noise model of CBCT projection data can improve the performance of the statistics-based projection restoration algorithm for low-dose CBCT.

60 APPLIED LIFE SCIENCES↗

A dual-Kinect approach to determine torso surface motion for respiratory motion correction in PET

Purpose: Respiratory gating is commonly used to reduce blurring effects and attenuation correction artifacts in positron emission tomography (PET). Established clinically available methods that employ body-attached hardware for acquiring respiration signals rely on the assumption that external surface motion and internal organ motion are well correlated. In this paper, the authors present a markerless method comprising two Microsoft Kinects for determining the motion on the whole torso surface and aim to demonstrate its validity and usefulness—including the potential to study the external/internal correlation and to provide useful information for more advanced correction approaches. Methods: The data of two Kinects are used to calculate 3D representations of a patient’s torso surface with high spatial coverage. Motion signals can be obtained for any position by tracking the mean distance to a virtual camera with a view perpendicular to the surrounding surface. The authors have conducted validation experiments including volunteers and a moving high-precision platform to verify the method’s suitability for providing meaningful data. In addition, the authors employed it during clinical {sup 18}F-FDG-PET scans and exemplarily analyzed the acquired data of ten cancer patients. External signals of abdominal and thoracic regions as well as data-driven signals were used for gating and compared with respect to detected displacement of present lesions. Additionally, the authors quantified signal similarities and time shifts by analyzing cross-correlation sequences. Results: The authors’ results suggest a Kinect depth resolution of approximately 1 mm at 75 cm distance. Accordingly, valid signals could be obtained for surface movements with small amplitudes in the range of only few millimeters. In this small sample of ten patients, the abdominal signals were better suited for gating the PET data than the thoracic signals and the correlation of data-driven signals was found to be stronger with abdominal signals than with thoracic signals (average Pearson correlation coefficients of 0.74 ± 0.17 and 0.45 ± 0.23, respectively). In all cases, except one, the abdominal respiratory motion preceded the thoracic motion—a maximum delay of approximately 600 ms was detected. Conclusions: The method provides motion information with sufficiently high spatial and temporal resolution. Thus, it enables meaningful analysis in the form of comparisons between amplitudes and phase shifts of signals from different regions. In combination with a large field-of-view, as given by combining the data of two Kinect cameras, it yields surface representations that might be useful in the context of motion correction and motion modeling.

60 APPLIED LIFE SCIENCES↗

Bradys Hot Springs Ambient Noise Correlation Functions (Initial Waveforms)

These files are ambient noise correlation (ANC) functions calculated for 11 days of continuous seismic data recorded by the Lawrence Berkeley network in the Brady geothermal field. These are SAC formatted seismic waveforms. The stations included are BPB04, BPB05, BPB07, BPB08, BPRT1, BPRT2, BPRT3, BPRT5, BRB10, BRP01, BRP02, BRP03, BRP04, BPR06, and BRP09 The original data were cut into hour long traces and processed by differentiating, removing the mean, removing the trend, applying a 1% taper, whitening, removing the mean and trend again, and converting to single bit traces. The data were then correlated with those from other stations and stacked. The resulting files were then named according to the convention: STA1.STA2.CHAN1_CHAN2.NHOURS.stacked.sac The days included are from records during 2013 (julian days, 200,220-229). The ANC correlations were calculated on the raw data traces (without instrument corrections applied) to assess the quality of the signal as a function of frequency throughout the network. The data were recorded at 500 Hz. We observe high quality signals 30 Hz on all traces, and measurable signal up to 80 Hz on a subset of the traces.

15 GEOTHERMAL ENERGY↗

Sapflow and xylem water isotopes from Snodgrass Mountain, East River Watershed, Colorado USA

This dataset includes sapflux and stable water isotopes of soil water and xylem water for aspen, fir and spruce trees along the Snodgrass Mountain transect in the East River Watershed, Colorado USA. The purpose of generating this dataset was to understand: (1) the total flux of water being used by trees in the watershed, (2) separate the component of transpiration that was derived from recent precipitation vs. older water such as winter precipitation of groundwater and (3) understand how total water use and water sources for the trees varies between species and position on a hillslope. The data were collected from May 2019 until October 2022. The sap flux data were collected using ICT SFM1 sensors and are presented in both units of cm h^-1 and as kg h^-1 by multiplying the sap flux by the sapwood area of the tree. All sap flow data has been been corrected using estimates of wounding diameter, water content of wood and sap wood depth. The xylem water isotope data were collected approximately weekly from each of the trees instrumented with sap flux. The stems were collected and the water extracted using classic cryogenic methods. Isotope measurements were done using a Picarro 2140i analyzer. We provide an estimate of the Seasonal Origin Index for each measurements following Allen et al., 2019 (10.5194/hess-23-1199-2019) where values of -1 equate to trees relying on winter precipitation and +1 tree relying on summer precipitation. We also provide the simultaneous sap flux for each isotope measurement when this data was available. This is an update to an earlier data repository with the same name that only included 2019 data. The new dataset was posted in January 2023 and is inclusive of the original 2019 data but now includes 2021 and 2022 data. Please note there was an error in the units of transpiration in the original dataset. It was incorrectly listed as mm h-1 when it should have been kg h-1. This change was made in May 2024.

54 ENVIRONMENTAL SCIENCES↗

AVHRR image navigation - Summary and review

The navigation of imagery from polar orbiting weather satellites includes the correction for geometric distortions due to earth shape/earth rotation, satellite orbit variations, and satellite attitude along with the resampling of the satellite image to a selected geographic map projection. The routine image navigation procedure also compensates for the distortion of the satellite imagery due to the nonlinear scanning of the sensor system. This paper reviews general methods for performing this image navigation, ranging from a method that assumes no orbital information and, thus, relies on nominal orbital parameter values and image corrections computed by matching ground control points (GCPs), to a method that uses high-quality satellite ephemeris data to make the correction with a limited number of GCPs. A procedure to optimize the image navigation by using a spatial remapping, or interpolation, is introduced and outlined. Recommendations are made for people interested in the processing of AVHRR imagery.

Emery, William J.↗