Analysis of Tank 38H (HTF-38-19-18, -19) and Tank 43H (HTF-43-19-20, -21) Samples for Support of the Enrichment Control and Corrosion Control Programs
SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. Overall, the results of the analysis indicate the concentrations of species in the Tank 38H surface sample increased significantly from the previous sample with the sodium concentration increasing from 1.09 M in the previous sample to 3.19 M in the current sample. However, it should be noted that the previous Tank 38H surface sample was very dilute compared with typical Tank 38H samples of the recent past. The Tank 38H sub-surface sample shows a composition fairly similar to the previous sample’s composition. Both the Tank 43H surface and sub-surface samples appear slightly more dilute than the previous samples based on the sodium concentrations. For both Tank 38H and Tank 43H, the subsurface samples appear slightly more concentrated for most species than the surface samples. These results indicate some success in increasing the salt solution concentration and reducing stratification in Tank 38H, but some stratification is still evident in both Tank 38H and Tank 43H.