Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controllable loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Stackelberg Game Based on Supervised Charging Method and Pricing Strategy of Charging Service Providers

The charging of large-scale electric vehicles (EVs) brings about a large new load to the electricity network, while it is also a demand response resource. Smart charging equipment and patterns of charging service will be one of the research focuses at the next stage. Smart charging equipment schedules EV's charging on the basis of electricity price, and this method enables users to hold the right of controlling their own EV's charging procedure. Thus, there exists a Stackelberg game between charging service providers, who set the price, and independent EVs. The marginal charging price, which reflects properties of individual EV, and the pricing strategy of charging service providers can be derived through solving this game problem. A price based charging strategy is proposed, which is suitable for the dynamic electricity price mechanism because of its light communication burden. In a simulation of a charging service provider covering 200 smart devices, this real-time supervised charging strategy shows its advantages of curbing users' payment and guiding the charging load effectively.

33 ADVANCED PROPULSION SYSTEMS↗

Lithium–Sulfur Batteries Enabled by Fluorine-Free Electrolytes with a Compressed Solvation Structure

In this paper, a fluorine-free aromatic cosolvent strategy is presented to regulate electrolyte solvation chemistry in Li-S batteries with sulfurized polyacrylonitrile (SPAN) cathodes. Assisted by the Uni-ELF AI tool and experimental validation, toluene is identified as an optimal weakly solvating cosolvent. Its incorporation compresses the Li⁺ solvation sheath and induces an anion-dominated solvation structure, thereby enhancing interfacial ion transport and sulfur redox kinetics through controlled π-π interactions with polysulfides. Consequently, Li || Li symmetric cells exhibit stable cycling for over 1,000 cycles at a current density of 1 mA cm⁻². Meanwhile, Li-S cells employing high-loading SPAN cathodes retain more than 75% of their initial capacity after 250 cycles at -10 °C. Additionally, a practical pouch cell with high SPAN loading and a low electrolyte-to-SPAN ratio of 3 µL mg⁻¹ delivers an initial capacity of around 600 mAh gSPAN⁻¹, underscoring the potential of fluorine-free electrolytes for practical metal-sulfur batteries.

25 ENERGY STORAGE↗

General Applications for Hamilton Vantage (GenApps for Vantage) v0.6.1

General applications for Hamilton Vantage is a flexible liquid handling method used to automate the most widely applicable types of automated liquid transfers. General applications can also be used as a tool to onboard new fully-automated workflows by breaking them down step by step into single transfers. The goal of General Applications is to make using the Hamilton Vantage liquid handler as easy & practical as using a handheld pipette for the end user. The software supports plate-to-plate transfers for a variety of method types including: Stamp: One-to-One, Stamp: One-To-Many, Split, Combine, Hitpick, and Qtray plating. General Applications eliminates the need for automation engineers to customize individual methods for each new workflow that gets onboarded. Steps can be customized within GenApps according to the needs of the researcher. The software utilizes a GUI to prompt the users to input variables – Allowing for flexible control over plate types, transfer volumes, number of replicates, tip types, liquid classes, mixing steps, aspiration/dispense heights and more. General Applications also generates a deck image and setup instructions to guide the researcher on how to load the deck and start the instrument.

Yoder, Sam↗

Cyber-Physical Dynamic System (CPDS) Modeling for Frequency Regulation and AGC Services of Distributed Energy Resources

The substantial integration of renewable energy brings significant challenges to balance the system in real time because of the variability and intermittency of renewable power. For the reliable system operation, the frequency regulation service is used to stabilize the system frequency through automatically balancing the system generation and load. On one hand, with the substantially increasing deployment of renewable energy in electricity system, the requirement of frequency regulation (FR) services increases significantly. On the other hand, the current main resource of FR services, the controllable conventional generation, is continuously decreasing in the system generation mix. This means that in the future high renewable penetration power system, additional and alternative reliable FR services providers such as distributed energy storage (DES) resources should be explored. Although the capability of utility-scale energy storage to provide FR services has been demonstrated, the integrated control and dynamic modeling of distributed energy resource (DER) providing frequency regulation grid services has been rarely explored. There are several challenges to adopt DERs to provide reliable grid services as illustrated in FERC 755. First, the distributed installation of DES requires a comprehensive cyber-physical dynamic system (CPDS) modeling to fully consider the impacts of the communication latency variability on its real time FR provision capability. Unlike the conventional generators, there are two-layer communication between DERs and system operators which increase the communication delay. Second, unlike the conventional generators whose dynamic models have been comprehensively studied, the difference among individual DER components' power-dynamic characteristic brings challenges in the accurate dynamic AGC modeling of its power-frequency relationship. Third, the temporal dependent state of charge uncertainty of DERs challenges DERs' power and frequency regulation capacities scheduling in the look-ahead generation scheduling. Therefore, the aggregator should optimize the frequency regulation provision from individual DER in real time. To overcome these challenges, this project proposes a cyber-physical dynamic system (CPDS) model to handle the uncertainty of DERs two-layer communication latency and power dynamics. The variability of DERs' communication delay and dynamic constraints will be comprehensively modeled. The DERs' AGC model with communication delay is designed to validate DESs' frequency regulation services. Like current performance-based frequency regulation evaluation, the delivery of DERs' frequency regulation will be assessed through post-analysis of the actual AGC response with respect to the AGC control signal from system operators. Consequently, the reliability improvement with DERs providing reliable frequency regulation services can be evaluated from a comprehensive perspective considering all the dynamics of communication and power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Best Basis Inventory Data to Direct Strategies for Real-Time Monitoring of Hanford High Level Waste

The proposed Direct Feed High Level Waste (DFHLW) approach for processing high-level tank waste at Hanford is intended to reduce processing time by bypassing the Pretreatment Facility and transferring waste directly from the tank farm to the WTP HLW vitrification facility. This processing strategy could reduce or eliminate the washing and leaching steps that would have occurred in the Pretreatment facility. Operation of the vitrification facility is subject to chemical and radiological limits protecting safety (e.g. Waste Acceptance Criteria, or WACs) and process quality (e.g. Process Control Limits, or PCLs). Without washing and leaching, there is a greater risk of exceeding the WACs and PCLs. Hanford process engineers have devised blending strategies based on known chemical and radiological composition, volumes, and solids loadings of individual layers within each waste tank. These blending campaigns succeed in predicting a processing strategy that does not exceed the WACs and PCLs. However, the calculations do not ascribe uncertainties to the tank analysis data, quantities of material taken from the tanks to make the blend, or potential for mixing of layers within tanks. In order to confirm that a process strategy is working, it would be advantageous to have inline or at-line analytical instrumentation installed in the processing facilities that deliver measurement results in real time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Guarded Hot Cylinder Apparatus for Characterization of Thermal Insulation Systems and Materials at Liquid Hydrogen Temperatures

As interest in liquid hydrogen (LH2) continues to grow within the energy and mobility sectors, so does the demand for testing capabilities at deep cryogenics temperatures. However, cost-, complexity-, and safety-related challenges associated with handling LH2 effectively limit the landscape of possible options. As an alternative, LH2 temperatures can be accessed via a helium-based cryogenic refrigerator, or “cryocooler”. Recently, NASA and its partners CB&I and Shell began the development of a cryocooler-based calorimeter to characterize the thermal performance of insulations and other materials down to 20 K. Deemed the Guarded Hot Cylinder (GHC), the apparatus utilizes a small vacuum chamber in conjunction with a GM cryocooler and trim heater to control the cold boundary temperature. A sealed, cylindrical copper cup bolts to the cryocooler and houses the material specimen, with an internal, cylindrical test heater assembly to maintain the warm boundary. The steady-state heat load, traveling radially through the specimen, is measured via the electrical input power to the test heater and then used to evaluate the material’s absolute thermal performance. Initial checkout and validation of the GHC using a common bulk-fill insulation material showed close agreement with published data from standardized LN2 boiloff calorimetry testing. The instrument is now considered a lab standard, with the goal of incorporating it into the ASTM C1774 standard in the future, and it is in continuous use, examining insulation materials for next-generation LH2 applications.

Swanger, Adam (ORCID:000000021487592X)↗

Smart Building Technology Training Modules for Academic and Professional Education

Smart building technologies are a new suite of resources that improve building energy efficiency and resilience, reduce carbon emissions, and provide load flexibility to the grid. However, in both college curricula and building professionals’ continuing education, there is a lack of systematic instruction on smart building technologies–topics that include smart building concepts, key components, smart building controls, “Internet of Things” (IoT) devices, and how to integrate multiple energy systems including distributed energy resources (DER). This major gap in smart building education prevents stakeholders from understanding and adopting smart building technologies in building design and operations. Slipstream leads a DOE-funded project developing a semester-long smart building curriculum for college students and adapting the contents into 16 training videos for building professionals and the general public. The education and training cover the drivers and benefits of smart building technologies, key building energy systems, the latest sensor technologies and IoT devices, and focus on topics related to smart building controls (i.e., energy management information systems, smart building control platforms, cybersecurity, grid-interactive-efficient buildings (GEBs), smart building control methods, and occupant-centric control. This paper describes the project approach, provides outlines of the training materials, and identifies lessons learned in creating the content. We also suggest ways to scale the instruction of smart building concepts to empower the workforce to accelerate the adoption of smart building technologies in the real world.

99 GENERAL AND MISCELLANEOUS↗

Best Practices for Shielding Analyses of Activated Metals and Spent Resins from Reactor Operation

This report investigated best practices for performing shielding evaluations of Type B waste packages, as defined in 10 CFR Part 71 regulations on packaging and transportation of radioactive material, or packages for which the contents are not defined before loading and may include a broad range of nuclides, geometries, and non-fuel materials. The following non-fuel waste streams were analyzed: Activated metals from decommissioned commercial power reactors, including Type 304 stainless steel, reactor vessel steel, and Inconel, Control blades from boiling water reactors, Neutron-activated corrosion products on surfaces of activated metals, and Spent resins from power plant operations. Measured elemental compositions, including major constituents and impurities, for steel and Inconel samples from commercial power reactors were used in activation calculations to determine radionuclide inventories in activated metals. For a simplified cask model, 60 Co contribution to the total external package dose rate at 30 days after shutdown varied from approximately 60% to 95%, depending on the activated metal, initial cobalt impurity concentration in the metal, and the thickness of the overpack gamma shield. Its maximum contribution to the total external package dose rate of approximately 100% was reached within the time interval of 2 to 5 years after shutdown and was maintained for up to 45 to 60 years after shutdown, depending on material, initial cobalt impurity concentration, and shield thickness. Thereafter, the 60 Co contribution to external package dose rate decreased with increasing decay time. Cobalt-60 is primarily produced by neutron reactions with the cobalt impurity in steel and Inconel. Other important radionuclides in activated metals contributing to package external dose rate are radionuclides with relatively short decay times, including 51 Cr, 59 Fe, 58 Co, and 54 Mn. These radionuclides may be represented as an equivalent 60 Co activity/source because 60 Co gamma ray emissions are bounding in terms of source strength and energy to other important radionuclides identified in the analyzed activated metals. Approaches for modeling the neutron-activated corrosion products that may be attached to activated reactor components were analyzed in this report. It was demonstrated that a surface source is more conservative than a uniform volumetric source for the treatment of neutron-activated corrosion products with respect to external package dose rates. An analysis of the maximum radionuclide loadings reported on spent resins identified the radionuclides 137 Cs, 60 Co, 134 Cs, 65 Zn, and 58 Co as the primary contributors to external package dose rate. For a resin cooled for 3.08 years, the external package dose rate was entirely produced by the reported 137 Cs and 60 Co inventory. The neutron sources from actinides found on spent resins or activated metals produced negligible dose rates and may be ignored in dose rate analyses. Effects of idealized waste material, source geometry, and spatial material/source distributions on external package dose rates were determined based on dose rate results for a simplified cask model under normal conditions of transport. Type 304 stainless steel, zirconium, and aluminum with adjusted mass densities based on a maximum content weight were analyzed for material modeling effects on external package dose rate. These materials produced identical external package dose rates within the statistical uncertainties of the dose rate estimates. Among four different source geometry configurations with homogeneous material of different mass densities, uniform volumetric source distribution, and the same source strength, the geometry configuration with lowest mass density (i.e., minimum self-shielding effect among the four cases) was most conservative. Spatial source distributions that better represent localized peak 60 Co activity values were more conservative than a uniform volumetric source distribution, assuming the same weight and total source strength per package. The increase in external dose rate caused by localized source peaks can be as much as the ratio between source peak activity density to average activity density, depending on the location of the activated metal with peak activity density. Therefore, the shielding analysis may be simplified if localized peak activities and the average activity per package can be measured/determined and documented at the time of cask loading. For simplicity, external package dose rates may be determined based on average source activity and a uniform volumetric source distribution. The dose rate results from that calculation model multiplied by the ratio of peak activity density to average activity density will produce maximum dose rate values for conservative estimates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamic Shaping of Grid Response of Multi-Machine Multi-Inverter Systems Through Grid-Forming IBRs

We consider the problem of controlling the frequency response of weakly-coupled multi-machine multi-inverter low-inertia power systems via grid-forming inverter-based resources (IBRs). In contrast to existing methods, our approach relies on dividing the larger system into multiple strongly-coupled subsystems, without ignoring either the underlying network or approximating the subsystem response as an aggregate harmonic mean model. Rather, through a structured clustering and recursive dynamic shaping approach, the frequency response of the overall system to load perturbations is shaped appropriately. We demonstrate the proposed approach for a three-node triangular configuration and a small-scale radial network. Furthermore, previous synchronization analysis for heterogeneous systems requires the machines to satisfy certain proportionality property. In our approach, the effective transfer functions for each cluster can be tuned by the IBRs to satisfy such property, enabling us to apply the shaping control to systems with a wider range of heterogeneous machines.

frequency-shaping control↗

Efficient excitation and control of integrated photonic circuits with virtual critical coupling

Critical coupling in integrated photonic devices enables the efficient transfer of energy from a waveguide to a resonator, a key operation for many applications. This condition is achieved when the resonator loss rate is equal to the coupling rate to the bus waveguide. Carefully matching these quantities is challenging in practice, due to variations in the resonator properties resulting from fabrication and external conditions. Here, we demonstrate that efficient energy transfer to a non-critically coupled resonator can be achieved by tailoring the excitation signal in time. We rely on excitations oscillating at complex frequencies to load an otherwise overcoupled resonator, demonstrating that a virtual critical coupling condition is achieved if the imaginary part of the complex frequency equals the mismatch between loss and coupling rate. We probe a microring resonator with tailored pulses and observe a minimum intensity transmission T = 0.11 in contrast to a continuous-wave transmission T = 0.58, corresponding to 8 times enhancement of intracavity intensity. Our technique opens opportunities for enhancing and controlling on-demand light-matter interactions for linear and nonlinear photonic platforms.

42 ENGINEERING↗

A reinforcement learning approach to long-horizon operations, health, and maintenance supervisory control of advanced energy systems

In this work, we develop a Reinforcement Learning (RL) approach to the supervisory control problem for advanced energy systems, such as novel nuclear reactors and other demand-driven, mission-critical, and component-health-sensitive energy plants. The inclusive problem landscape considered captures the stochastic confluence of plant performance, component health evolution, power demand from the grid, diverse maintenance actions, and operator-defined goals and constraints, all considered over meaningfully long-enough reasoning horizons. Key aspects of the proposed approach are a receding horizon control-inspired technique dictating time- or event-triggered supervisory policy (re-)constructions, as well as additional capability-enabling contributions such as timescale compression, to handle long reasoning horizons and uncertainty in parts of the problem, and practical yet demonstrably-effective handling of hybrid action spaces with continuous and discrete decision variables. The resulting algorithm consists of a simulation-based RL agent constructing stochastic supervisory control policies over nontrivial action spaces and for long horizons, applying the learned policy to the system for a much shorter interval, and perpetually repeating, to construct the next long-horizon policy. That next policy will only be applied, again, for a short interval, yet originally far-in-time events move progressively closer, their associated uncertainty decreases, and new events and aspects enter the reasoning horizon. The proposed methodology bridges fundamental receding horizon concepts with the unequivocally stronger and more scalable reasoning of contemporary RL. Numerical examples using Soft Actor–Critic Deep RL illustrate the operation and efficacy of the proposed technique for a power plant tasked with health-aware load following missions in a dynamic electricity market landscape.

97 MATHEMATICS AND COMPUTING↗

Long-term drought promotes invasive species by reducing wildfire severity

Anthropogenic climate change has increased the frequency of drought, wildfire, and invasions of non-native species. Although high-severity fires linked to drought can inhibit recovery of native vegetation in forested ecosystems, it remains unclear how drought impacts the recovery of other plant communities following wildfire. We leveraged an existing rainfall manipulation experiment to test the hypothesis that reduced precipitation, fuel load, and fire severity convert plant community composition from native shrubs to invasive grasses in a Southern California coastal sage scrub system. We measured community composition before and after the 2020 Silverado wildfire in plots with three rainfall treatments. Drought reduced fuel load and vegetation cover, which reduced fire severity. Native shrubs had greater prefire cover in added water plots compared to reduced water plots. Native cover was lower and invasive cover was higher in postfire reduced water plots compared to postfire added and ambient water plots. Our results demonstrate the importance of fuel load on fire severity and plant community composition on an ecosystem scale. Management should focus on reducing fire frequency and removing invasive species to maintain the resilience of coastal sage scrub communities facing drought. In these communities, controlled burns are not recommended as they promote invasive plants.

54 ENVIRONMENTAL SCIENCES↗

Field tests of a highly flexible downwind ultralight rotor to mimic a 13-MW turbine rotor

Offshore extreme-scale turbines of 20–25 MW in size may offer reduced energy costs. The technical barriers at these extreme scales include escalating blade masses with increased flexibility as well as high gravity loads and tower-strike issues. These barriers may be addressed with a load-aligning downwind turbine. To investigate this type of design, a field test campaign was conducted with an aeroelastically scaled rotor, termed the Segmented Ultralight Morphing Rotor Demonstrator (SUMR-D). The tests were conducted on the Controls Advanced Research Turbine at the National Renewable Energy Laboratory. The paper gives an overview of the experimental diagnostics, blade design, and results of the field campaign, as well as makes conclusions and recommendations regarding extreme-scale highly flexible downwind rotors.

17 WIND ENERGY↗

Report of the Condition of a General Electric Transportation Systems Gearbox

Wind power plant operations and maintenance (O&M) costs remain an appreciable contributor to the overall cost of wind energy. Premature of wind turbine gearboxes failures are often a result of abrasive wear, micropitting, scuffing, white-etch cracks, and macropitting issues. Micropitting is a fatigue phenomenon that occurs in Hertzian contacts in both gears and rolling-element bearings that operate in mixed or micro elastohydrodynamic lubrication regimes. Micropitting is influenced by and manifests itself in many different ways depending on operating conditions such as load, speed and operating temperature, and on factors such as gear geometry and accuracy, tooth flank roughness, percentage of tooth sliding, and lubricant composition. Despite much research by many investigators, micropitting remains complex, unpredictable, and difficult to control and remains a problem in wind turbine gearboxes. The purpose of this report is to document and describe the micropitting damage observed in a wind turbine gearbox, thereby facilitating further analysis and examination in future reports.

17 WIND ENERGY↗

Evaluating the Thermal Impacts of Inadvertent Export on Service Transformers

As more DER interconnect to the system there are times where the total generation (or load) of a DER cannot be supported by the system. To more quickly allow these DER to interconnect they may need to regulate their output to a different export capacity than their nameplate capacity via a power control system (PCS). In the time it takes PCS to respond, however, an inadvertent export may occur, where the DER operates beyond its export limit. This report evaluates the potential thermal impact such momentary violations may have on service transformers, to determine whether response times should be more tightly controlled or not.

42 ENGINEERING↗

OC6 Project Phase IV: Validation of Numerical Models for Novel Floating Offshore Wind Support Structures

The fourth phase of the Offshore Code Comparison, Collaboration, Continued, with Correlation and unCertainty (OC6) aims to assess the ability of the tools to model a novel floating wind design. The design that was selected for this project is the TetraSpar designed by Stiesdal Offshore Technologies. The platform is a unique design that features a spar like stability with a very low center of gravity, but does not require deep-water ports. This combination is achieved with a system made of two separate steel structures, a hull at the water’s surface that supports the wind turbine tower, and a keel that is suspended below the main body. This lower keel has a very high density and drives the total platform’s low center of gravity. Scaled model tests of the TetraSpar design were performed in 2018-2019 by the University of Maine. The tests were performed with 1:43 Froude scaling. The data collected in the model tests provide a detailed description of the response of the platform in various controlled and relatively well understood conditions. Comparison with these data provides a good opportunity for validation of numerical models. The OC6 Phase IV work will focus on the specific parameters used in these scaled model tests. The load cases (LC) considered in this project are as follows: LC 1.X - Equilibrium and Static Offset Tests LC 2.X - Platform Free Decays LC 3.X - Turbine Thrust (Wind Only) LC 4.X - Regular and Irregular Waves (Wave only) LC 5.X - Combined Wind and Wave Loading

17 WIND ENERGY↗

Design of a SMART Valve Testbed for Nuclear Thermal Dispatch

By the year 2050, the United States aims to achieve net-zero carbon emissions. To achieve this target, the licensing of the Light Water Reactor (LWR) fleet has been extended for 20 more years. To stay economically competitive with other power sources such as renewable and fossil-fuel power plants, the U.S. Department of Energy has introduced a plan to modernize the existing LWR fleet and diversify the revenue stream. One of the plans is to dispatch thermal energy to endothermic industrial processes. SMART valves will play an important role in this initiative by efficiently balancing the load by regulating valves in a coordinated manner while monitoring the thermal-hydraulic systems to enhance safety and maintain the integrity of the power plant. This research aims to develop a facility to test the coordinated control algorithm and produce various test results for training the monitoring system. The constructed facility is capable of simulating various operational and accidental scenarios by coordinating all the valves (positions) and pump (flowrate). The facility is developed with an Internet of Things (IoT)-based custom system and a python-based valve position control and coordination mechanism. It has achieved stable sensor outputs, pump control, and coordinated valve regulation in all three valves with minimum obstruction in the system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Managing time-substitutable electricity usage using dynamic controls

A predictive-control approach allows an electricity provider to monitor and proactively manage peak and off-peak residential intra-day electricity usage in an emerging smart energy grid using time-dependent dynamic pricing incentives. The daily load is modeled as time-shifted, but cost-differentiated and substitutable, copies of the continuously-consumed electricity resource, and a consumer-choice prediction model is constructed to forecast the corresponding intra-day shares of total daily load according to this model. This is embedded within an optimization framework for managing the daily electricity usage. A series of transformations are employed, including the reformulation-linearization technique (RLT) to obtain a Mixed-Integer Programming (MIP) model representation of the resulting nonlinear optimization problem. In addition, various regulatory and pricing constraints are incorporated in conjunction with the specified profit and capacity utilization objectives.

Ghosh, Soumyadip↗