Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VAPOR PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Two-phase flow characteristics across sudden contraction in small rectangular channels

This study examines the two-phase flow pattern change and pressure drop at the sudden contraction from small rectangular channels (3 x 9 mm and 3 x 6 mm) into a 3 mm diameter tube. A unique deflection of contraction pressure drop vs. vapor quality is observed at a very low quality regime with an unusual ''liquid like vena contracta''. The measured pressure drops are compared with existing correlations/models, but none of them can accurately predict the available database. By proposing a correction factor accounting for the influence of surface tension (Bond number and contraction ratio) to the original homogeneous model, considerable improvement of the predictive ability of homogeneous model is arrived. The mean deviation of this correlation is 26.18% applicable to the present data (80 points) and available literatures (357 points). (author)

42 ENGINEERING↗

Mass variation of a thin liquid film driven by an acoustic wave

In this work, we investigate the dynamics of a thin liquid film subjected to an acoustic field in its bounding vapor space. For large acoustic wavelengths, the field imposes a spatially uniform, temporally periodic temperature and pressure at the vapor side of the film interface, which leads to a periodic driving force for mass exchange with the vapor. Neglecting the dynamics of the vapor space, we adopt the “one-sided” model for evaporation/condensation of thin liquid films. In the interest of determining the effect of oscillatory mass exchange on film stability, we consider films in thermodynamic equilibrium with the mean vapor conditions. The effects of oscillatory phase change on both linear stability and nonlinear dynamics are investigated for slightly inclined ceiling films that are destabilized by gravity and subject to thermocapillary effects. At linear order, this mass exchange is not found to alter the band of unstable wave numbers and only marginally affects the growth rates. Additionally, the mass exchanged during evaporation is balanced by condensation so that the total mass of the liquid film is conserved. However, due to nonlinear effects, we find that traveling waves encouraged by the inclination are subject to net mass loss. It is then found that normal thermocapillary effects enhance this loss, and that anomalous thermocapillarity mitigates or even reverses the loss to a mass gain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Miniature Reversal Electron-Attachment Detector

Miniature reversal electron-attachment detector (miniREAD) enables direct injection of air or vapor at atmospheric pressure from monitored area into mass-spectrometric instrument to detect explosives, narcotics, or other substances, vapors of which suspected of being present in low concentrations. In comparison with older reversal electron-attachment detector, miniREAD simpler in design; more rugged; and easier to build, repair, and maintain. In addition, probably more sensitive.

Chutjian, Ara↗

Assessing the Quality of Molecular Simulations for Vapor–Liquid Equilibria: An Analysis of the TraPPE Database

As molecular modeling and simulation techniques become increasingly important sources of thermophysical property and phase equilibrium data, the ability to assess the robustness of that data becomes more critical. Recently, the use of the compressibility factor (Z) has been suggested as a metric for testing the quality of simulation data for vapor–liquid equilibria (VLE). Int his paper, we analyze predicted VLE data from the transferable potentials for phase equilibria (TraPPE) database and show that, apart from data entry or typographical errors, Z will always be well-behaved in Gibbs ensemble Monte Carlo (GEMC) simulations even when the simulations are not sufficiently equilibrated. However, this is not true for grand canonical Monte Carlo simulations. When the pressure is calculated from the internal forces, then pressure and density are strongly correlated for the vapor phase and, for GEMC simulations, it is recommended to treat Z as an instantaneous mechanical property. From analysis of the TraPPE VLE data, we propose a complementary metric based on the predicted vapor pressures at three neighboring temperatures and their deviation from a local Clausius–Clapeyron fit.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Durable Suit Bladder with Improved Water Permeability for Pressure and Environment Suits

Water vapor permeability is shown to be useful in rejecting heat and managing moisture accumulation in launch-and-entry pressure suits. Currently this is accomplished through a porous Gortex layer in the Advanced Crew and Escape Suit (ACES) and in the baseline design of the Constellation Suit System Element (CSSE) Suit 1. Non-porous dense monolithic membranes (DMM) that are available offer potential improvements for water vapor permeability with reduced gas leak. Accordingly, three different pressure bladder materials were investigated for water vapor permeability and oxygen leak: ElasthaneTM 80A (thermoplastic polyether urethane) provided from stock polymer material and two custom thermoplastic polyether urethanes. Water vapor, carbon dioxide and oxygen permeability of the DMM's was measured in a 0.13 mm thick stand-alone layer, a 0.08 mm and 0.05 mm thick layer each bonded to two different nylon and polyester woven reinforcing materials. Additional water vapor permeability and mechanical compression measurements were made with the reinforced 0.05 mm thick layers, further bonded with a polyester wicking and overlaid with moistened polyester fleece thermal underwear .This simulated the pressure from a supine crew person. The 0.05 mm thick nylon reinforced sample with polyester wicking layer was further mechanically tested for wear and abrasion. Concepts for incorporating these materials in launch/entry and Extravehicular Activity pressure suits are presented.

Bue, Grant C.↗

Improvement of the RELAP5-3D Model of Condensation in the Presence of Noncondensables

Condensation of steam on the primary side of a steam generator in a pressurized water reactor (PWR) is one means of removing decay heat during some accident scenarios, including small break loss of coolant accident (SBLOCA). However, when noncondensable gasses mix with steam, it impairs condensation. To correctly predict plant behavior, nuclear power plant (NPP) safety analysis codes such as RELAP5-3D must model the effect of condensation in the presence of noncondensables properly. A potential error in the RELAP5-3D code was reported in the condensation model in the presence of noncondensables by the University of Wisconsin (Fu 2015). The report indicated that the calculated condensation heat flux was under-predicted due to the modeling of the mass transfer in the gas mixture. The original documentation describing the implementation of the model was reviewed and compared with alternative formulations. An alternative that uses saturation vapor density at temperature of total pressure instead of the saturation vapor density at vapor partial pressure for calculating vapor mass flux was implemented. Comparison of the alternative method with the original against experimental data for several test cases showed improvement for most test cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Liquid Oxygen Thermodynamic Vent System Testing with Helium Pressurization

This report presents the results of several thermodynamic vent system (TVS) tests with liquid oxygen plus a test with liquid nitrogen. In all tests, the liquid was heated above its normal boiling point to 111 K for oxygen and 100 K for nitrogen. The elevated temperature was representative of tank conditions for a candidate lunar lander ascent stage. An initial test series was conducted with saturated oxygen liquid and vapor at 0.6 MPa. The initial series was followed by tests where the test tank was pressurized with gaseous helium to 1.4 to 1.6 MPa. For these tests, the helium mole fraction in the ullage was quite high, about 0.57 to 0.62. TVS behavior is different when helium is present than when helium is absent. The tank pressure becomes the sum of the vapor pressure and the partial pressure of helium. Therefore, tank pressure depends not only on temperature, as is the case for a pure liquid-vapor system, but also on helium density (i.e., the mass of helium divided by the ullage volume). Thus, properly controlling TVS operation is more challenging with helium pressurization than without helium pressurization. When helium was present, the liquid temperature would rise with each successive TVS cycle if tank pressure was kept within a constant control band. Alternatively, if the liquid temperature was maintained within a constant TVS control band, the tank pressure would drop with each TVS cycle. The final test series, which was conducted with liquid nitrogen pressurized with helium, demonstrated simultaneous pressure and temperature control during TVS operation. The simultaneous control was achieved by systematic injection of additional helium during each TVS cycle. Adding helium maintained the helium partial pressure as the liquid volume decreased because of TVS operation. The TVS demonstrations with liquid oxygen pressurized with helium were conducted with three different fluid-mixer configurations-a submerged axial jet mixer, a pair of spray hoops in the tank ullage, and combined use of the axial jet and spray hoops. A submerged liquid pump and compact heat exchanger located inside the test tank were used with all the mixer configurations. The initial series without helium and the final series with liquid nitrogen both used the axial jet mixer. The axial jet configuration successfully demonstrated the ability to control tank pressure; but in the normal-gravity environment, the temperature in the upper tank region (ullage and unwetted wall) was not controlled. The spray hoops and axial jet combination also successfully demonstrated pressure control as well as temperature control of the entire tank and contents. The spray-hoops-only configuration was not expected to be a reliable means of tank mixing because there was no direct means to produce liquid circulation. However, surprisingly good results also were obtained with the sprayhoops- only configuration (i.e., performance metrics such as cycle-averaged vent flowrate were similar to those obtained with the other configurations). A simple thermodynamic model was developed that correctly predicted the TVS behavior (temperature rise or pressure drop per TVS cycle) when helium was present in the ullage. The model predictions were correlated over a range of input parameters. The correlations show that temperature rise or pressure drop per cycle was proportional to both helium mole fraction and tank heat input. The response also depended on the tank fill fraction: the temperature rise or pressure drop (per TVS cycle) increased as the ullage volume decreased.

Thermodynamic vent system↗

Development of a Water Based, Critical Flow, Non-Vapor Compression cooling Cycle

Expansion of a high-pressure liquid refrigerant through the use of a thermostatic expansion valve or other device is commonplace in vapor-compression cycles to regulate the quality and flow rate of the refrigerant entering the evaporator. In vapor-compression systems, as the condensed refrigerant undergoes this expansion, its pressure and temperature drop, and part of the liquid evaporates. We (researchers at Kansas State University) are developing a cooling cycle that instead pumps a high-pressure refrigerant through a supersonic converging-diverging nozzle. As the liquid refrigerant passes through the nozzle, its velocity reaches supersonic (or critical-flow) conditions, substantially decreasing the refrigerant’s pressure. This sharp pressure change vaporizes some of the refrigerant and absorbs heat from the surrounding conditions during this phase change. Due to the design of the nozzle, a shockwave trips the supersonic two-phase refrigerant back to the starting conditions, condensing the remaining vapor. The critical-flow refrigeration cycle would provide space cooling, similar to a chiller, by running a secondary fluid such as water or glycol over one or more nozzles. Rather than utilizing a compressor to raise the pressure of the refrigerant, as in a vapor-cycle system, the critical-flow cycle utilizes a high-pressure pump to drive refrigerant liquid through the cooling cycle. Additionally, the design of the nozzle can be tailored for a given refrigerant, such that environmentally benign substances can act as the working fluid. This refrigeration cycle is still in early-stage development with prototype development several years away. The complex multi-phase flow at supersonic conditions presents numerous challenges to fully understanding and modeling the cycle. With the support of DOE and venture-capital investors, initial research was conducted at PAX Streamline, and later, at Caitin. We (researchers at Kansas State University) have continued development of the cycle and have gained an in-depth understanding of the governing fundamental knowledge, based on the laws of physics and thermodynamics and verified with our testing results. Through this research, we are identifying optimal working fluid and operating conditions to eventually demonstrate the core technology for space cooling or other applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Zero-gravity venting of three refrigerants

An experimental investigation of venting cylindrical containers partially filled with initially saturated liquids under zero-gravity conditions was conducted in the NASA Lewis Research Center 5-second zero-gravity facility. The effect of interfacial mass transfer on the ullage pressure response during venting was analytically determined, based on a conduction analysis applied to an infinitely planer (flat) liquid-vapor interface. This pressure response was compared with both the experimental results and an adiabatic decompression computation.

Labus, T. L.↗

Real-Time Optical Monitoring of Flow Kinetics and Gas Phase Reactions Under High-Pressure OMCVD Conditions

This contribution addresses the real-time optical characterization of gas flow and gas phase reactions as they play a crucial role for chemical vapor phase depositions utilizing elevated and high pressure chemical vapor deposition (HPCVD) conditions. The objectives of these experiments are to validate on the basis of results on real-time optical diagnostics process models simulation codes, and provide input parameter sets needed for analysis and control of chemical vapor deposition at elevated pressures. Access to microgravity is required to retain high pressure conditions of laminar flow, which is essential for successful acquisition and interpretation of the optical data. In this contribution, we describe the design and construction of the HPCVD system, which include access ports for various optical methods of real-time process monitoring and to analyze the initial stages of heteroepitaxy and steady-state growth in the different pressure ranges. To analyze the onset of turbulence, provisions are made for implementation of experimental methods for in-situ characterization of the nature of flow. This knowledge will be the basis for the design definition of experiments under microgravity, where gas flow conditions, gas phase and surface chemistry, might be analyzed by remote controlled real-time diagnostics tools, developed in this research project.

Dietz, N.↗

Temperature and Density on the Forsterite Liquid‐Vapor Phase Boundary

Abstract The physical processes during planet formation span a large range of pressures and temperatures. Giant impacts, such as the one that formed the Moon, achieve peak pressures of 100s of GPa. The peak shock states generate sufficient entropy such that subsequent decompression to low pressures intersects the liquid‐vapor phase boundary. The entire shock‐and‐release thermodynamic path must be calculated accurately in order to predict the post‐impact structures of planetary bodies. Forsterite (Mg 2 SiO 4 ) is a commonly used mineral to represent the mantles of differentiated bodies in hydrocode models of planetary collisions. Here, we performed shock experiments on the Sandia Z Machine to obtain the density and temperature of the liquid branch of the liquid‐vapor phase boundary of forsterite. This work is combined with previous work constraining pressure, density, temperature, and entropy of the forsterite principal Hugoniot. We find that the vapor curves in previous forsterite equation of state models used in giant impacts vary substantially from our experimental results, and we compare our results to a recently updated equation of state. We have also found that due to under‐predicted entropy production on the principal Hugoniot and elevated temperatures of the liquid vapor phase boundary of these past models, past impact studies may have underestimated vapor production. Furthermore, our results provide experimental support to the idea that giant impacts can transform much of the mantles of rocky planets into supercritical fluids.

58 GEOSCIENCES↗

Multi-Sensor Data from A-Train Instruments Brought Together for Atmospheric Research

The A-Train is comprised of a series of instruments, developed independently, that measure highly related atmospheric components along the same flight path. In order to intercompare data from this multitude of sensors, researchers must access, subset, visualize, analyze and correlate distributed atmosphere measurements from the various A-Train instruments. The A-Train Data Depot (ATDD) has been operational for over a year, successfully performing the aforementioned functions on behalf of researchers, thus providing co-registered data from the Cloudsat, CALIOP, AIRS, and MODIS instruments for further intercomparisons. Of late, significant data from OM1 and POLDER are now included in the 'depot'. By specifying the desired spatial and temporal range, the researcher can subset, visualize, co-register, and access multi-sensor A-Train data related to: Cloud, aerosol, atmospheric temperature, and water vapor parameters (vertical profile visualizations); Cloud Pressure, cloud top temperature, water vapor, cloud optical thickness, and aerosol products (horizontal strips subsetted +/- 100km from the profile visualizations), and; Cloud pressure parameters (2-D line plots overlayed on the vertical profiles). All data is plotted using the GIOVANNI data exploration tool. A new feature of GIOVANNI is its ability to have collocated and subsetted data sets as well as PNG image files downloaded to the researcher's computing facility. By providing a convenient way to visualize and acquire multi-sensor data, ATDD affords users more time and effort to further their research.

Smith, Peter M.↗

Mass Flux of ZnSe by Physical Vapor Transport

Mass fluxes of ZnSe by physical vapor transport (PVT) were measured in the temperature range of 1050 to 1160 C using an in-situ dynamic technique. The starting materials were either baked out or distilled under vacuum to obtain near-congruently subliming compositions. Using an optical absorption technique Zn and Se, were found to be the dominant vapor species. Partial pressures of Zn and Se, over the starting materials at temperatures between 960 and 1140 C were obtained by measuring the optical densities of the vapor phase at the wavelengths of 2138, 3405, 3508, 3613, and 3792 A. The amount and composition of the residual gas inside the experimental ampoules were measured after the run using a total pressure gauge. For the first time, the experimentally determined partial pressures of Zn and Se, and the amount and composition of the residual gas were used in a one-dimensional diffusion limited analysis of the mass transport rates for a PVT system. Reasonable agreement between the experimental and theoretical results was observed.

Sha, Yi-Gao↗

A kinetic and equilibrium analysis of silicon carbide chemical vapor deposition on monofilaments

Chemical kinetics of atmospheric pressure silicon carbide (SiC) chemical vapor deposition (CVD) from dilute silane and propane source gases in hydrogen is numerically analyzed in a cylindrical upflow reactor designed for CVD on monofilaments. The chemical composition of the SiC deposit is assessed both from the calculated total fluxes of carbon and silicon and from chemical equilibrium considerations for the prevailing temperatures and species concentrations at and along the filament surface. The effects of gas and surface chemistry on the evolution of major gas phase species are considered in the analysis.

Gokoglu, S. A.↗

Pressure Profiles in a Loop Heat Pipe Under Gravity Influence

During the operation of a loop heat pipe (LHP), the viscous flow induces pressure drops in various elements of the loop. The total pressure drop is equal to the sum of pressure drops in vapor grooves, vapor line, condenser, liquid line and primary wick, and is sustained by menisci at liquid and vapor interfaces on the outer surface of the primary wick in the evaporator. The menisci will curve naturally so that the resulting capillary pressure matches the total pressure drop. In ground testing, an additional gravitational pressure head may be present and must be included in the total pressure drop when LHP components are placed in a non-planar configuration. Under gravity-neutral and anti-gravity conditions, the fluid circulation in the LHP is driven solely by the capillary force. With gravity assist, however, the flow circulation can be driven by the combination of capillary and gravitational forces, or by the gravitational force alone. For a gravity-assist LHP at a given elevation between the horizontal condenser and evaporator, there exists a threshold heat load below which the LHP operation is gravity driven and above which the LHP operation is capillary force and gravity co-driven. The gravitational pressure head can have profound effects on the LHP operation, and such effects depend on the elevation, evaporator heat load, and condenser sink temperature. This paper presents a theoretical study on LHP operations under gravity neutral, anti-gravity, and gravity-assist modes using pressure diagrams to help understand the underlying physical processes. Effects of the condenser configuration on the gravitational pressure head and LHP operation are also discussed.

0000↗

Pressure Profiles in a Loop Heat Pipe under Gravity Influence

During the operation of a loop heat pipe (LHP), the viscous flow induces pressure drops in various elements of the loop. The total pressure drop is equal to the sum of pressure drops in vapor grooves, vapor line, condenser, liquid line and primary wick, and is sustained by menisci at liquid and vapor interfaces on the outer surface of the primary wick in the evaporator. The menisci will curve naturally so that the resulting capillary pressure matches the total pressure drop. In ground testing, an additional gravitational pressure head may be present and must be included in the total pressure drop when LHP components are placed in a non-planar configuration. Under gravity-neutral and anti-gravity conditions, the fluid circulation in the LHP is driven solely by the capillary force. With gravity assist, however, the flow circulation can be driven by the combination of capillary and gravitational forces, or by the gravitational force alone. For a gravity-assist LHP at a given elevation between the horizontal condenser and evaporator, there exists a threshold heat load below which the LHP operation is gravity driven and above which the LHP operation is capillary force and gravity co-driven. The gravitational pressure head can have profound effects on the LHP operation, and such effects depend on the elevation, evaporator heat load, and condenser sink temperature. This paper presents a theoretical study on LHP operations under gravity-neutral, anti-gravity, and gravity-assist modes using pressure diagrams to help understand the underlying physical processes. Effects of the condenser configuration on the gravitational pressure head and LHP operation are also discussed.

Thermal Control Systems↗

Thermodynamic analysis of cascade microcryocoolers with low pressure ratios

The vapor-compression cycle for refrigeration near ambient temperature achieves high efficiency because the isenthalpic expansion of the condensed liquid is a rather efficient process. However, temperatures are limited to about 200 K with a single-stage system. Temperatures down to 77 K are possible with many stages. In the case of microcryocoolers using microcompressors, pressure ratios are usually limited to about 6 or less. As a result, even more stages are required to reach 77 K. If the microcompressors can be fabricated with low-cost wafer-level techniques, then the use of many stages with separate compressors may become a viable option for achieving temperatures of 77 K with high efficiency. We analyze the ideal thermodynamic efficiency of a cascade Joule-Thomson system for various temperatures down to 77 K and with low pressure ratios. About nine stages are required for 77 K, but fewer stages are also analyzed for operation at higher temperatures. For 77 K, an ideal second-law efficiency of 83 % of Carnot is possible with perfect recuperative heat exchangers and 65 % of Carnot is possible with no recuperative heat exchangers. The results are compared with calculated efficiencies in mixed-refrigerant cryocoolers over the range of 77 K to 200 K. Refrigeration at intermediate temperatures is also available. The use of single-component fluids in each of the stages is expected to eliminate the problem of pulsating flow and temperature oscillations experienced in microcryocoolers using mixed refrigerants.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗