Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Plasma enhanced atomic layer deposition and atomic layer etching of gallium oxide using trimethylgallium

Atomic layer etching driven by self-limiting thermal reactions has recently been developed as a highly conformal and isotropic technique for low damage atomic scale material removal by sequential exposures of vapor phase reactants. Gallium oxide (Ga2O3) is currently among the materials of interest due to a large variety of applications including power electronics, solar cells, gas sensors, and photon detectors. In this study, Ga2O3 was deposited by plasma enhanced atomic layer deposition using trimethylgallium [TMG, Ga(CH3)3] and O2 plasma at a substrate temperature of 200 °C. We report a newly developed method for Ga2O3 thermal atomic layer etching, in which surface modification is achieved through HF exposure resulting in a gallium fluoride surface layer, and then removed through volatile product formation via ligand exchange with TMG. Saturation of the precursor exposure at a substrate temperature of 300 °C resulted in an etch rate of 1.0 ± 0.1 Å/cycle for amorphous Ga2O3. Uniformity and conformality of the atomic layer etching process were confirmed via atomic force microscopy with a measured surface roughness of 0.55 ± 0.05 nm that remains unchanged after etching. The use of TMG for etching may expand available precursors for atomic layer etching processes, while allowing for both etching and deposition of Ga2O3 using the same metalorganic precursor.

Hatch, Kevin A. (ORCID:0000000283118623)↗

Characterization of high-temperature figure of merit for solar-thermal absorbers

The figure of merit (FOM) is a widely used metric to characterize the solar-thermal conversion performance of solar absorber layers. Many of previous works have reported FOMs estimated from the radiative properties measured at room temperature. However, advanced concentrated solar power (CSP) plants operate at very high temperatures (~750°C), which can strongly affect the absorber’s radiative properties. Here, the present work proposes using a 1-D conduction-based reference bar technique to directly measure the converted thermal energy to determine the FOM at high absorber temperatures (≳ 750°C) while operating under a large solar concentration (~ 1200 x suns). Using the finite difference method, we carefully analyze several key parameters influencing the design of the experimental setup, such as temperature distribution, material properties, heat loss, and sensor accuracy. In addition, a rigorous uncertainty analysis is incorporated into the FOM to ascertain the confidence level of the result. We validate this new technique on a custom-built tungsten reference bar with an oxidized Inconel 625 solar-thermal absorber. A good agreement between the model and the experiment shows the reliability of the FOM measurement with a well-defined uncertainty. The same method can be implemented to measure the high-temperature FOM of most surface or volumetric solar absorbers for CSP.

14 SOLAR ENERGY↗

Nanomaterials for Sensor Applications

A large part of the advances in nanotechnology have been directed towards the development of highspeed electronics, more efficient catalysts, and sensors. This latter group of applications has great relevance and unprecedented development potential for the coming years. Some of the main objectives for the development of sensors have focused on making more sensitive, effective and specific sensing devices. The improvement of these systems and the increase of specificity are clearly associated with a decrease in size of the components, which can lead to obtaining more rapid action, almost in real time. Nanomaterials currently used in sensor development include a long list of nanostructured systems, as for example: Metal nanotubes, nanowires, nanofibers, nanocomposites, nanorods, nanoparticles, nanostructured polymers, and different allotropes of carbon as carbon nanotubes, graphene or fullerenes, among others [1]. These nanomaterials are characterized by having unique physicochemical properties, including high electrical and thermal conductivity, extremely high surface area/volume ratio, high mechanical strength and even excellent catalytic properties [1] [2]. These materials, may exhibit relevant physicochemical behavior, such as quantization or electronic confinement effects, which can be used in the development of all kinds of sensors [2]. So far, sensors have been developed for determination and quantification of gases, radiation, biomolecules, microorganisms, etc. [2] [3]. The sensors developed so far usually use the system lock and key, wherein the selective receptor (lock) is selectively anchored to the analyte of interest (or key). This system has great limitations when analyzing the analyte in the presence of other analytes, which can alter the sensitivity or specificity of the measure, as occurs in sensors used in biomedical applications [3] [4]. One possible solution is based on the development of sensor arrays, consisting of a combination of different and specific sensors, which may enable simultaneous measurements of one or more analytes in a less favorable environment [5] in these cases. These sensors are now a reality, although there is still a long way to go before the levels of precision and accuracy are reached. Future challenges for the development and commercialization of efficient sensors are mainly focused on improving the specificity, reproducibility, and the ability to detect trace levels. We hope that in the coming years nanotechnology and nanomaterials allow reaching previously unimaginable advances in the development of these systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Synthesis and luminescent properties of Er3+-activated LaBMoO6 green-emitting phosphors for optical thermometry

Highlights: • Under 380 nm excitation, all the samples emitted visible green emissions from the Er{sup 3+} ions. • The optimal doping concentration was 1 mol% and the critical distance was 28.47 Å. • The maximum sensor sensitivity of the studied phosphors was found to be as high as 0.0179 K{sup −1} at 483 K. • The sensor sensitivity of the obtained samples was independent of Er{sup 3+} ion concentration. - Abstract: The Er{sup 3+}-activated LaBMoO{sub 6} phosphors were synthesized by a sol-gel method. The photoluminescence (PL) emission intensity was revealed to be dependent on the Er{sup 3+} ion concentration and its maximum value was achieved when the doping concentration was 1 mol%. From theoretical analysis, one knows that the concentration quenching mechanism is dominated by the electric dipole-dipole interaction with a critical distance of 28.47 Å. On the basis of the temperature-dependent PL green emission spectra from the {sup 2}H{sub 11/2} and {sup 4}S{sub 3/2} thermally coupled levels by means of the fluorescence intensity ratio technique, the temperature sensing properties of the resultant compounds were studied. When the temperature was 483 K, the sensor sensitivity of the studied samples reached up to 0.017 K{sup −1}. It was found that the sensor sensitivity of the prepared phosphors was hardly varied by the doping concentration. These obtained characteristics suggest that the Er{sup 3+}-activated LaBMoO{sub 6} phosphors have potential applications in optical thermometry.

36 MATERIALS SCIENCE↗

Creating a Voyager Thermal Model 39 Years Into the Flight Mission, Along with Model Correlation and Application

After 39 years of continuous operation in space, the output of the Voyager 1 & 2 spacecraft RTG power systems has decreased to the point where managing the power margin and maintaining thermal control has become increasingly difficult. As the total power dissipation in the bus has decreased, propellant line temperatures and margin above minimum AFTs have decreased, creating risk of the hydrazine freezing (at 1.6°C). This is further complicated by the lack of existing thermal models that can be used to assess propellant tank and line temperatures. In 2014, an effort was begun to create a Voyager spacecraft thermal model for that purpose.A steady-state Thermal Desktop model has been created from scratch over the past two years. The initial thermal model development was started by Applied Sciences Laboratory (ASL) under contract to JPL. The effort relied primarily on archived manufacturing drawings, limited documentation, interviews of senior engineers who worked on the Voyager design and implementation, and the experience of the Voyager Flight Operations team.Data from the Voyager System Thermal Vacuum tests is no longer available, making it necessary to correlate the model to more recent flight data and small in-flight tests. Correlation was achieved to within ±5°C for a hot case and a cold case (both data sets from 2014). However, the flight system has very few temperature sensors directly on propellant lines. So the task remains to determine how best to use the model, in conjunction with flight data, to make sure the Voyagers can continue to fly successfully. How does one go about creating a thermal model for a spacecraft that is already launched, has limited existing mechanical description files, no thermal model in order to do a maneuver that was never planned when the spacecraft was designed?

Ledeboer, William C.↗

Design study for Thermal Infrared Multispectral Scanner (TIMS)

The feasibility of dividing the 8-12 micrometer thermal infrared wavelength region into six spectral bands by an airborne line scanner system was investigated. By combining an existing scanner design with a 6 band spectrometer, a system for the remote sensing of Earth resources was developed. The elements in the spectrometer include an off axis reflective collimator, a reflective diffraction grating, a triplet germanium imaging lens, a photoconductive mercury cadmium telluride sensor array, and the mechanical assembly to hold these parts and maintain their optical alignment across a broad temperature range. The existing scanner design was modified to accept the new spectrometer and two field filling thermal reference sources.

Stanich, C. G.↗

THE THERMAL PROPERTIES OF SOLAR FLARES OVER THREE SOLAR CYCLES USING GOES X-RAY OBSERVATIONS

Solar flare X-ray emission results from rapidly increasing temperatures and emission measures in flaring active region loops. To date, observations from the X-Ray Sensor (XRS) on board the Geostationary Operational Environmental Satellite (GOES) have been used to derive these properties, but have been limited by a number of factors, including the lack of a consistent background subtraction method capable of being automatically applied to large numbers of flares. In this paper, we describe an automated Temperature and Emission measure-Based Background Subtraction method (TEBBS), that builds on the methods of Bornmann. Our algorithm ensures that the derived temperature is always greater than the instrumental limit and the pre-flare background temperature, and that the temperature and emission measure are increasing during the flare rise phase. Additionally, TEBBS utilizes the improved estimates of GOES temperatures and emission measures from White et al. TEBBS was successfully applied to over 50,000 solar flares occurring over nearly three solar cycles (1980-2007), and used to create an extensive catalog of the solar flare thermal properties. We confirm that the peak emission measure and total radiative losses scale with background subtracted GOES X-ray flux as power laws, while the peak temperature scales logarithmically. As expected, the peak emission measure shows an increasing trend with peak temperature, although the total radiative losses do not. While these results are comparable to previous studies, we find that flares of a given GOES class have lower peak temperatures and higher peak emission measures than previously reported. The TEBBS database of flare thermal plasma properties is publicly available at http://www.SolarMonitor.org/TEBBS/.

79 ASTRONOMY AND ASTROPHYSICS↗

OccuTherm: Occupant Thermal Comfort Inference using Body Shape Information

Thermal comfort is a decisive factor for the well-being, productivity, and overall satisfaction of commercial building occupants. Many commercial building automation systems either use a fixed zone-wide temperature set-point for all occupants or they rely on extensive sensor deployments with frequent online interaction with occupants. This results in inadequate comfort levels or significant training effort from users, respectively. However, the increasing ubiquity of cheap, depth-based occupancy tracking systems has enabled an improvement in inferential capabilities. We propose the novel system OccuTherm to model thermal comfort of occupants. We conducted a laboratory study with 77 participants to collect data for the implementation of a thermal comfort model that derives thermal comfort using the human body shape. Based on the comparison with model baselines and ablations, we show that our approach infers thermal comfort of individuals with 60 % accuracy when body shape information is taken into account; 6 % more than state-of-the-art approaches. We make our code, mobile app, datasets, and models freely available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detector Development for the MARE Neutrino Experiment

The MARE experiment is designed to measure the mass of the neutrino with sub-eV sensitivity by measuring the beta decay of {sup 187}Re with cryogenic microcalorimeters. A preliminary analysis shows that, to achieve the necessary statistics, between 10,000 and 50,000 detectors are likely necessary. We have fabricated and characterized Iridium transition edge sensors with high reproducibility and uniformity for such a large scale experiment. We have also started a full scale simulation of the experimental setup for MARE, including thermalization in the absorber, detector response, and optimum filter analysis, to understand the issues related to reaching a sub-eV sensitivity and to optimize the design of the MARE experiment. We present our characterization of the Ir devices, including reproducibility, uniformity, and sensitivity, and we discuss the implementation and capabilities of our full scale simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

All-Ceramic Passive Wireless Temperature Sensor Realized by Tin-Doped Indium Oxide (ITO) Electrodes for Harsh Environment Applications

In this work, an all-ceramic passive wireless inductor–capacitor (LC) resonator was presented for stable temperature sensing up to 1200 °C in air. Instead of using conventional metallic electrodes, the LC resonators are modeled and fabricated with thermally stable and highly electroconductive ceramic oxide. The LC resonator was modeled in ANSYS HFSS to operate in a low-frequency region (50 MHz) within 50 × 50 mm geometry using the actual material properties of the circuit elements. The LC resonator was composed of a parallel plate capacitor coupled with a planar inductor deposited on an Al2O3 substrate using screen-printing, and the ceramic pattern was sintered at 1250 °C for 4 h in an ambient atmosphere. The sensitivity (average change in resonant frequency with respect to temperature) from 200–1200 °C was ~170 kHz/°C. The temperature-dependent electrical conductivity of the tin-doped indium oxide (ITO, 10% SnO2 doping) on the quality factor showed an increase of Qf from 36 to 43 between 200 °C and 1200 °C. The proposed ITO electrodes displayed improved sensitivity and quality factor at elevated temperatures, proving them to be an excellent candidate for temperature sensing in harsh environments. The microstructural analysis of the co-sintered LC resonator was performed using a scanning electron microscope (SEM) which showed that there are no cross-sectional and topographical defects after several thermal treatments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncooled Micro-Cantilever Infrared Imager Optimization

We report on the development, fabrication and characterization of microcantilever based uncooled focal plane array (FPA) for infrared imaging. By combining a streamlined design of microcantilever thermal transducers with a highly efficient optical readout, we minimized the fabrication complexity while achieving a competitive level of imaging performance. The microcantilever FPAs were fabricated using a straightforward fabrication process that involved only three photolithographic steps (i.e. three masks). A designed and constructed prototype of an IR imager employed a simple optical readout based on a noncoherent low-power light source. The main figures of merit of the IR imager were found to be comparable to those of uncooled MEMS infrared detectors with substantially higher degree of fabrication complexity. In particular, the NETD and the response time of the implemented MEMS IR detector were measured to be as low as 0.5K and 6 ms, respectively. The potential of the implemented designs can also be concluded from the fact that the constructed prototype enabled IR imaging of close to room temperature objects without the use of any advanced data processing. The most unique and practically valuable feature of the implemented FPAs, however, is their scalability to high resolution formats, such as 2000 x 2000, without progressively growing device complexity and cost. The overall technical objective of the proposed work was to develop uncooled infrared arrays based on micromechanical sensors. Currently used miniature sensors use a number of different readout techniques to accomplish the sensing. The use of optical readout techniques sensing require the deposition of thin coatings on the surface of micromechanical thermal detectors. Oak Ridge National Laboratory (ORNL) is uniquely qualified to perform the required research and development (R&D) services that will assist our ongoing activities. Over the past decade ORNL has developed a number of unique methods and techniques that led to improved sensors using a number of different approaches.

47 OTHER INSTRUMENTATION↗

NEET Enhanced Micro-Pocket Fission Detector for High Temperature Reactors - FY16 Status Report

A collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Atomic Energy Agency, Commissariat à l'Énergie Atomique et aux Energies Alternatives, (CEA), has been initiated by the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) program for developing and testing High Temperature Micro-Pocket Fission Detectors (HT MPFD), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package for temperatures up to 800 °C. The MPFD technology utilizes a small, multi-purpose, robust, in-core fission chambers and thermocouple. As discussed within this report, the small size, variable sensitivity, and increased accuracy of the MPFD technology represent a revolutionary improvement over current methods used to support irradiations in US Material Test Reactors (MTRs). Previous research conducted through NEET ASI1-3 has shown that the MPFD technology could be made robust and was successfully tested in a reactor core. This new project will further the MPFD technology for higher temperature regimes and other reactor applications by developing a HT MPFD suitable for temperatures up to 800 °C. This report summarizes the research progress for year two of this three year project. Highlights from research accomplishments include: • Continuation of a joint collaboration between INL, KSU, and CEA. Note that CEA is participating at their own expense because of interest in this unique new sensor. • An updated parallel wire HT MPFD design was developed. • Program support for HT MPFD deployments was given to Accident Tolerant Fuels (ATF) and Advanced Gas-cooled Reactor (AGR) irradiation test programs. • Quality approved materials for HT MPFD construction were procured by irradiation test programs for upcoming deployments. • KSU improved and performed electrical contact and fissile material plating. • KSU delivered fissile HT MPFD parts to INL for final construction of HT MPFD prototype. • A prototype HT MPFD was constructed and analyzed at INL. • The HT MPFD has been modeled in MCNP to optimize the amount of fissile material deposition. • The HT MPFD has been modeled in MCNP to optimize the sensor location in the irradiation test. • The fissile material deposition is undergoing independent verifications. • Detector amplifier electronics have been revised and tested by KSU. • Several project meetings were held at INL and KSU to discuss the roles and responsibilities between INL, KSU, and CEA for development and deployment of the HT MPFDs. As documented in this report, FY16 funding has allowed the project to meet year two planned accomplishments to develop a HT MPFD. In addition, the accomplishments of this project have attracted independent funding from other Department of Energy Office of Nuclear Energy (DOE-NE) programs for MTR irradiations of the MPFD technology. These are significant opportunities for this NEET Enhanced Micro-Pocket Fission Detector for High Temperature Reactors project because the irradiation expense of these experiments could not be included in the original project scope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared Sensor on Unmanned Aircraft Transmits Time-Critical Wildfire Data

Since 2006, NASA fs Dryden Flight Research Center (DFRC) and Ames Research Center have been perfecting and demonstrating a new capability for geolocation of wildfires and the real-time delivery of data to firefighters. Managed for the Western States Fire Mission, the Ames-developed Autonomous Modular Scanner (AMS), mounted beneath a wing of DFRC fs MQ-9 Ikhana remotely piloted aircraft, contains an infrared sensor capable of discriminating temperatures within 0.5 F (approx. = 0.3 C), up to 1,000 F (approx. = 540 C). The AMS operates like a digital camera with specialized filters to detect light energy at visible, infrared, and thermal wavelengths. By placing the AMS aboard unmanned aircraft, one can gather information and imaging for thousands of square miles, and provide critical information about the location, size, and terrain around fires to commanders in the field. In the hands of operational agencies, the benefits of this NASA research and development effort can support nationwide wildfire fighting efforts. The sensor also provides data for post-burn and vegetation regrowth analyses. The MQ-9 Unmanned Aircraft System (UAS), a version of the Predator-B, can operate over long distances, staying aloft for over 24 hours, and controlled via a satellite-linked command and control system. This same link is used to deliver the fire location data directly to fire incident commanders, in less than 10 minutes from the time of overflight. In the current method, similarly equipped short-duration manned aircraft, with limited endurance and range, must land, hand-carry, and process data, and then deliver information to the firefighters, sometimes taking several hours in the process. Meanwhile, many fires would have moved over great distances and changed direction. Speed is critical. The fire incident commanders must assess a very dynamic situation, and task resources such as people, ground equipment, and retardant-dropping aircraft, often in mountainous terrain obscured by dense smoke.

Pestana, Mark↗

The Single Cells and Cell Populations Viability Estimation in vitro by the Time-Domain Impedance Spectroscopy

In the present study, we investigate the sensitivity and applicability of the time-domain electrical impedance spectroscopy (EIS) techniques, namely Fourier-EIS and adaptive filtering based EIS (AF-EIS), for studying cells' populations and single living cells in natural physiological environment in vitro. Using ultra-violet radiation for decreasing cell life-span we demonstrate the possibility to distinguish the living cells' population from the dead cells by both Fourier-EIS and AF-EIS. However, determining the viability of the single cell requires significant sensitivity, which is inaccessible with the conventional Fourier-EIS contrary to AF-EIS. The latter result stems from the high noise immunity of the AF-EIS, which also makes it possible to provide the measurements using the safe for cells 15-mV excitation voltage and 10–100 nA current response. The developed single-cell AF-EIS approach opens a direct roadmap for creating accurate, robust, and easy to implement toxin and radiation hazard sensors with the living cell as an acting element and proposes a solution for actual ecological and healthcare problems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Zernike Wavefront Sensor Modeling Development for LOWFS on WFIRST-AFTA

WFIRST-AFTA design makes use of an existing 2.4m telescope for direct imaging of exoplanets. To maintain the high contrast needed for the coronagraph, wavefront error (WFE) of the optical system needs to be continuously sensed and controlled. Low Order Wavefront Sensing (LOWFS) uses the rejected starlight from an immediate focal plane to sense wavefront changes (mostly thermally induced low order WFE) by combining the LOWFS mask (a phase plate located at the small center region with reflective layer) with the starlight rejection masks, i.e. Hybrid Lyot Coronagraph (HLC)'s occulter or Shaped Pupil Coronagraph (SPC)'s field stop. Zernike wavefront sensor (ZWFS) measures phase via the phase-contrast method and is known to be photon noise optimal for measuring low order aberrations. Recently, ZWFS was selected as the baseline LOWFS technology on WFIST/AFTA for its good sensitivity, accuracy, and its easy integration with the starlight rejection mask. In this paper, we review the theory of ZWFS operation, describe the ZWFS algorithm development, and summarize various numerical sensitivity studies on the sensor performance. In the end, the predicted sensor performance on SPC and HLC configurations are presented.

Zernike phase contrast↗

Experimental Performance of a Micromachined Heat Flux Sensor

Steady-state and frequency response calibration of a microfabricated heat-flux sensor have been completed. This sensor is batch fabricated using standard, micromachining techniques, allowing both miniaturization and the ability to create arrays of sensors and their corresponding interconnects. Both high-frequency and spatial response is desired, so the sensors are both thin and of small cross-sectional area. Thin-film, temperature-sensitive resistors are used as the active gauge elements. Two sensor configurations are investigated: (1) a Wheatstone-bridge using four resistors; and (2) a simple, two-resistor design. In each design, one resistor (or pair) is covered by a thin layer (5000 A) thermal barrier; the other resistor (or pair) is covered by a thick (5 microns) thermal barrier. The active area of a single resistor is 360 microns by 360 microns; the total gauge area is 1.5 mm square. The resistors are made of 2000 A-thick metal; and the entire gauge is fabricated on a 25 microns-thick flexible, polyimide substrate. Heat flux through the surface changes the temperature of the resistors and produces a corresponding change in resistance. Sensors were calibrated using two radiation heat sources: (1) a furnace for steady-state, and (2) a light and chopper for frequency response.

TEMPERATURE SENSITIVE ELEMENTS↗

NEET Enhanced Micro Pocket Fission Detector for High Temperature Reactors - FY15 Status Report

A new project, that is a collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Atomic Energy Agency, Commissariat à l'Énergie Atomique et aux Energies Alternatives, (CEA), has been initiated by the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) program for developing and testing High Temperature Micro-Pocket Fission Detectors (HT MPFD), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package for temperatures up to 800 °C. The MPFD technology utilizes a small, multi-purpose, robust, in-core parallel plate fission chamber and thermocouple. As discussed within this report, the small size, variable sensitivity, and increased accuracy of the MPFD technology represent a revolutionary improvement over current methods used to support irradiations in US Material Test Reactors (MTRs). Previous research conducted through NEET ASI1-3 has shown that the MPFD technology could be made robust and was successfully tested in a reactor core. This new project will further the MPFD technology for higher temperature regimes and other reactor applications by developing a HT MPFD suitable for temperatures up to 800 °C. This report summarizes the research progress for year one of this three year project. Highlights from research accomplishments include: A joint collaboration was initiated between INL, KSU, and CEA. Note that CEA is participating at their own expense because of interest in this unique new sensor. An updated HT MPFD design was developed. New high temperature-compatible materials for HT MPFD construction were procured. Construction methods to support the new design were evaluated at INL. Laboratory evaluations of HT MPFD were initiated. Electrical contact and fissile material plating has been performed at KSU. Updated detector electronics are undergoing evaluations at KSU. A project meeting was held at KSU to discuss the roles and responsibilities between INL and KSU for development of the HT MPFDs. Provide input to various irradiation programs for installation of the MPFD technology in irradiation tests. As documented in this report, FY15 funding has allowed the project to meet year one planned accomplishments to develop a HT MPFD that offers US MTR users enhanced capabilities for real-time measurement of flux and temperature with a single detector. In addition, the accomplishments of this project have attracted funding from other Department of Energy Office of Nuclear Energy (DOE-NE) programs for additional applications. The work in those programs will build on current activities completed in this NEETASI HT MPFD project, but the MPFD will be specifically tailored to meet their program needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗