Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

2023 Site Environmental Report: Volume 1

Brookhaven National Laboratory (BNL) is managed on behalf of the Department of Energy (DOE) by Brookhaven Science Associates (BSA), a partnership between Stony Brook University and Battelle, and six core universities: Columbia, Cornell, Harvard, Massachusetts Institute of Technology, Princeton, and Yale. For over 75 years, the Laboratory has played a lead role in the DOE Science and Technology mission and continues to contribute to the DOE’s missions in energy resources, environmental quality, and national security. BNL manages its world-class scientific research operations with sensitivity to environmental issues and community concerns. The Laboratory’s Environmental, Safety, Security, and Health (ESSH) Policy reflects the commitment of BNL’s management to fully integrate environmental stewardship into all facets of its mission and operations. BNL prepares an annual Site Environmental Report (SER) in accordance with DOE Order 231.1B, Environment, Safety, and Health Reporting. The report is written to inform the public, regulators, employees, and other stakeholders of the Laboratory’s environmental performance during the calendar year in review. Volume I of the SER summarizes environmental data; environmental management performance; compliance with applicable DOE, federal, state, and local regulations; and performance in restoration and surveillance monitoring programs. BNL has prepared annual SERs since 1971 and has documented nearly all its environmental history since the Laboratory’s inception in 1947. Volume II of the SER, the Groundwater Status Report, is also prepared annually to report on the status of groundwater protection and restoration efforts. Volume II includes detailed technical summaries of groundwater data and treatment system operations and is intended for regulators and other technically oriented stakeholders. A summary of the information contained in Volume II is included in Chapter 7, Groundwater Protection, of this volume.

54 ENVIRONMENTAL SCIENCES↗

A Community Energy Operations and Planning System: Concept, Use cases, Metrics, and Benefits

Community and city leaders are interested in achieving sustainability goals, providing resilient energy infrastructure, and improving economic competitiveness. Community-level data acquisition and analysis can provide energy and associated benefits that are not possible at the single building level. However, there is a lack of organizational structure, common semantic data models, interoperable systems, and methods to support data-driven decision-making for community-scale energy supply and demand systems. We explored the need and opportunity for a Community Energy Operations and Planning System (Community EOPS), a potential data exchange platform. We conducted “customer discovery” interviews, and reviewed literature, public tools, and technology platforms to identify key energy data “users” and use cases in communities. The key users of the Community EOPS could be developers of mixed-use districts, corporate, defense and university campus energy managers, and city managers of cities that own their energy utility. The value could be for community planning and reporting (for energy data-integrated land use planning and community infrastructure investments in microgrids, storage, district heating and cooling), energy efficiency (leveraging optimizations for community scale energy supply and demand), flexible load management (grid-edge load management to offset, shift, and flatten loads for multiple buildings and EV fleets), cost savings and revenue generation (participating in grid services), and social benefits such as energy resilience, equity, and awareness. We developed a conceptual Community EOPS architecture with recommendations for streamlined and prioritized data acquisition, sharing, and integration driven by prioritized use cases, common metrics, and actionable visualizations that can provide value to a community’s users.

Singh, Reshma↗

Modeling transmission line constraints in two-stage robust unit commitment problem

Integration of renewable energy sources and demand response poses new challenges to system operators as they increase the uncertainty of the power supply and demand. Recently, robust optimization techniques are applied to the unit commitment problem with uncertainty as an alternative to the stochastic programming approaches. However, it remains challenging to solve the robust unit commitment model with full transmission line constraints. In this paper, we propose novel acceleration techniques for solving two-stage robust unit commitment problem with consideration of full transmission line constraints. We use 1) the cutting-plane algorithm for the master problem, which dynamically includes critical transmission line constraints, and 2) column-generation methods, including the branch-and-price-and-cut algorithm and heuristic approaches, for the subproblems, which add only necessary transmission line dual variables on the fly. Furthermore, computational results for the modified IEEE 118-bus system show that the combination of the cutting-plane algorithm and the heuristic column-generation approach greatly reduces the total solution time of the two-stage robust unit commitment problem.

Heuristic algorithms↗

A Physical Model Enhanced Data Driven Method for High-Resolution Residential Load Profile Generation

Residential buildings account for significant energy consumption, creating opportunities to offer grid services. As electric utilities seek to implement effective system operation strategies, understanding residential energy consumption patterns becomes essential; However, the time intervals of load profiles measured by utilities' smart meters are typically from 15 minutes to 60 minutes. The low-resolution data make it hard to extract appliance-level load information, which is critical for providing grid services. This paper presents a load profile generator designed to produce synthetic load profiles for residential buildings that emphasizes the importance of accurate representations of realistic energy consumption patterns. The generator takes realistic low-resolution residential load measurements and weather data as inputs, producing 1-minute interval profiles that match the characteristics of the original profiles. Further, this generator can be used to populate load profiles in areas where actual measurements are limited to improve the ability of utilities to analyze their distribution systems. By providing more high-resolution residential building load profiles, this tool supports electric utilities to enhance their residential building load control strategies and improve overall grid stability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power over fiber development for HEP detectors

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground and electromagnetic isolation is critical. In cryogenic environments, PoF offers a reliable power transmission technology, leveraging optical fibers to transfer power with minimal system degradation. PoF technology excels in maintaining low noise levels and isolation when delivering power to sensitive electronic systems operating in extreme temperature ranges and high voltage environments. Here, in a novel application of PoF for a HEP detector, power is provided to photon detector modules located on a surface at ~300 kV with respect to ground in the planned DUNE experiment. This summary paper of the PoF talk at the 16th PISA Meeting on Advanced Detectors highlights the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications offering a dependable solution with low noise, optimal efficiency, and superior isolation. The DUNE (Abi et al., 2020) experiment will soon deploy large liquid argon (LAr) time projection chambers (TPC) to detect neutrino interactions and other particle physics phenomena. In addition to the particle tracking provided by the TPC, photon detectors, powered by a first ever PoF system, in the cryostat will leverage the high scintillation light yield of LAr to provide crucial timing and additional calorimetric information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

eCounter: Inline Per-IP Network Monitoring at Millisecond Resolution via eBPF

Scientific data acquisition (SciDAQ) systems are shifting from archive-based workflows to streaming paradigms, where real-time, fine-grained network monitoring becomes essential. While P4-enabled devices offer per-packet in-band observability, they require specialized switches and routers. Host-side tools like Prometheus exporters lack sufficient temporal granularity. To bridge this gap, we present eCounter, a lightweight, hardware-agnostic, inline telemetry agent built on extended Berkeley Packet Filter (eBPF). eCounter captures per-interface ingress and egress traffic, categorized by IP address and protocol, at millisecond to sub-millisecond resolution. In a 100 Gbps environment, it continuously exports up to 3,257 time-series bins per second with only 4% CPU utilization at a 35¿KiB/s data rate. We evaluate eCounter across diverse NIC MTU settings, hook types, CPU architectures and operating systems, and observed negligible impact on concurrent high-throughput streaming applications. Complexity analysis confirms that it can be readily scaled to distributed SciDAQ deployments.

Mei, Xinxin [Computational Sciences and Technology↗

Valuing EV Managed Charging for Bulk Power Systems

When and where electric vehicle (EV) charging occurs has significant implications for power systems supporting widespread EV adoption, especially with high shares of wind and solar generation. This study extends previous works by leveraging detailed simulation models for EV adoption, EV use, EV charging, and bulk power system operations, and by linking them with methods for describing charging flexibility at both the individual vehicle and aggregate levels. This technical potential study focuses on how the value of EV managed charging (EVMC) changes depending on charging flexibility type (within-charging session or within-week scheduling), dispatch mechanism (direct load control or one of several price-based mechanisms), and managed charging participation rate. We show that naively aggregating EV charging flexibility from individual vehicles into megawatt-scale resources grossly overestimates the flexibility of the fleet, because such aggregate models can unrealistically pair, e.g., one already-fully-charged vehicle's ability to increase load with another already-charging vehicle's ability to accept more charge, effectively requesting a charging rate that is infeasible for the latter vehicle. We find per-vehicle bulk system value is highest at low participation rates for all dispatch mechanisms. Factoring in production cost savings, avoided firm capacity savings, and combustion-related power sector emissions savings, we estimate the value of EVMC at low participation rates (5%) to be $33/vehicle-year to $69/vehicle-yr for within-session charging flexibility and $40/vehicle-yr to $120/vehicle-yr for within-week charging flexibility in an envisioned 2038 New England power system and monetary value reported in 2016 U.S. dollars. At 100% participation, per-vehicle value declines to $25/vehicle-yr to $31/vehicle-yr for within-session charging flexibility and to $29/vehicle-yr to $36/vehicle-yr for within-week charging flexibility; however, 100% participation yields the highest total system savings.

ADVANCED PROPULSION SYSTEMS↗

ComEd Climate Risk and Adaptation Outlook, Phase 1: Temperature, Heat Index, and Average Wind

This Climate Risk and Adaptation Outlook report presents the research and findings of a joint venture between Commonwealth Edison (ComEd) and Argonne National Laboratory (Argonne) to evaluate future climate risks to ComEd’s infrastructure and operations. ComEd recognizes that its position as the state of Illinois’ largest electric utility, serving roughly 70% of the state’s population, underscores the importance for communities across Illinois to consider climate risk as they plan for future conditions. Climate impacts, such as more severe heatwaves or more frequent flood events, can disrupt the generation, transmission, and distribution of electricity and create public health challenges. Taking a proactive approach to adapt to climate risks will help ensure that ComEd continues to serve its growing customer-base reliably and efficiently. This Climate Risk and Adaptation Outlook serves as an important first step to inform ComEd’s grid planning efforts, but Argonne and ComEd recognize that additional research beyond this report will be necessary to characterize future climate conditions more comprehensively throughout northern Illinois, to assess their impacts to grid assets and system operations, and to index effective adaptation options at an asset-level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Overview: Precipitation characteristics and sensitivities to environmental conditions during GoAmazon2014/5 and ACRIDICON-CHUVA

This study provides an overview of precipitation processes and their sensitivities to environmental conditions in the Central Amazon Basin near Manaus during the GoAmazon2014/5 and ACRIDICON-CHUVA experiments. Here, this study takes advantage of the numerous measurement platforms and instrument systems operating during both campaigns to sample cloud structure and environmental conditions during 2014 and 2015; the rainfall variability among seasons, aerosol loading, land surface type, and topography has been carefully characterized using these data. Differences between the wet and dry seasons were examined from a variety of perspectives. The rainfall rates distribution, total amount of rainfall, and raindrop size distribution (the mass-weighted mean diameter) were quantified over both seasons. The dry season generally exhibited higher rainfall rates than the wet season and included more intense rainfall periods. However, the cumulative rainfall during the wet season was 4 times greater than that during the total dry season rainfall, as shown in the total rainfall accumulation data. The typical size and life cycle of Amazon cloud clusters (observed by satellite) and rain cells (observed by radar) were examined, as were differences in these systems between the seasons. Moreover, monthly mean thermodynamic and dynamic variables were analysed using radiosondes to elucidate the differences in rainfall characteristics during the wet and dry seasons. The sensitivity of rainfall to atmospheric aerosol loading was discussed with regard to mass-weighted mean diameter and rain rate. This topic was evaluated only during the wet season due to the insignificant statistics of rainfall events for different aerosol loading ranges and the low frequency of precipitation events during the dry season. The impacts of aerosols on cloud droplet diameter varied based on droplet size. For the wet season, we observed no dependence between land surface type and rain rate. However, during the dry season, urban areas exhibited the largest rainfall rate tail distribution, and deforested regions exhibited the lowest mean rainfall rate. Airplane measurements were taken to characterize and contrast cloud microphysical properties and processes over forested and deforested regions. Vertical motion was not correlated with cloud droplet sizes, but cloud droplet concentration correlated linearly with vertical motion. Clouds over forested areas contained larger droplets than clouds over pastures at all altitudes. Finally, the connections between topography and rain rate were evaluated, with higher rainfall rates identified at higher elevations during the dry season.

54 ENVIRONMENTAL SCIENCES↗

Effect of chemical substitutions on photo-switching properties of 3-hydroxy-picolinic acid studied by ab initio methods

Effect of chemical substitutions to the molecular structure of 3-hydroxy-picolinic acid on photo-switching properties of the system operating on excited-state intramolecular double proton transfer (d-ESIPT) process [M. F. Rode and A. L. Sobolewski, Chem. Phys. 409, 41 (2012)] was studied with the aid of electronic structure theory methods. It was shown that simultaneous application of electron-donating and electron-withdrawing substitutions at certain positions of the molecular frame increases the height of the S{sub 0}-state tautomerization barrier (ensuring thermal stability of isomers) and facilitates a barrierless access to the S{sub 1}/S{sub 0} conical intersection from the Franck-Condon region of the S{sub 1} potential-energy surface. Results of study point to the conclusion that the most challenging issue for practical design of a fast molecular photoswitch based on d-ESIPT phenomenon are to ensure a selectivity of optical excitation of a given tautomeric form of the system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Implementation of Real-Time Off-Grid Detection Tool Based on FNET/GridEye

Real-time situational awareness tools are of critical importance to power system operators, especially during emergencies. The availability of electric power has become a linchpin of most post disaster response efforts as it is the primary dependency for public and private sector services, as well as individuals. Knowledge of the scope and extent of facilities impacted, as well as the duration of their dependence on backup power, enables emergency response officials to plan for contingencies and provide better overall response. Based on real-time data acquired by Frequency Disturbance Recorders (FDRs) deployed in the North American power grid, a real-time detection method is proposed. This method monitors critical electrical loads and detects the transition of these loads from an on-grid state, where the loads are fed by the power grid to an off-grid state, where the loads are fed by an Uninterrupted Power Supply (UPS) or a backup generation system. The details of the proposed detection algorithm are presented, and some case studies and off-grid detection scenarios are also provided to verify the effectiveness and robustness. Meanwhile, the algorithm has already been implemented based on the Grid Solutions Framework (GSF) and has effectively detected several off-grid situations.

Guo, Jiahui↗

High Burst Rate Charging System for the Lithium Lens Power Supply

Two pulsed power systems have been upgraded for the g-2 experiment at Fermilab. The Pbar Lithium Lens supply previously ran with a half sine pulsed current of 75 kA peak, 400 us duration and a repetition rate of 0.45 pps. For the g-2 experiment, the peak current was reduced to 25 kA, but the repetition rate was increased to an average of 12 pps. Furthermore, the pulses come in a burst of 8 with 10 ms between each of 8 pulses and then a delay until the next burst. The charging rate has gone up by a factor of 20 due to the burst speed. A major challenge for the upgrade was to charge the capacitor bank while keeping the power line loading and charging supply cost to a reasonable level. Furthermore, this paper will discuss how those issues were solved and results from the operational system.

43 PARTICLE ACCELERATORS↗

Autonomous Radiation Mapping and Quantification using an Unmanned Ground Vehicle. Part I - Environment Mapping

When characterizing facilities, advanced autonomous systems are safe, efficient, and cost-effective tools, which can safely deploy state-of-the-art instrumentation without exposing workers to radiation risks. One main focus of the research is the visual mapping of the environment.This paper presents a framework for the mapping aspect that utilizes lidar and SLAM technologies coupled with a monocular camera to create a point cloud of the environment. Upon completion, the present research work aims to provide an autonomous mobile robot the capability to localize itself and aid the user with visualizing the radiation data. Challenges: C++ node needs to properly synchronize image and point cloud data. 3D lidar has resolution of ± 3 cm. Proper camera calibration needed. Transforms need to be precise for proper alignment of image and point-cloud. Results: Voxelated point clouds. Accurate colors from calibrated cameras including details smaller than lidar resolution. Developed Robotics Operating System (ROS) package for ease of transfer to other robot platforms.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solar Ramping Distributions over Multiple Timescales and Weather Patterns

As greater amounts of solar power are included in the power system, it is becoming increasingly important to have a better characterization of the variability of solar power over the timescales that are relevant to power system operations. In this paper, we examine the distribution of ramp events that occur in global horizontal irradiance measurements from a number of sites in the western UnitedStates. The distributions are found to be significantly non-normal over multiple timescales from 1 minute to 1 hour. A hyberbolic distribution is suggested for more accurately representing the observed ramp distributions. Additionally, the ramp distributions that occur during different classifications of weather patterns are characterized and significant differences are observed between patterns.

14 SOLAR ENERGY↗

Miniaturized Magnetoelastic Sensor System

This article describes the design, assembly, and implementation of a hand-held, magnetic-field-based sensor system that can be adapted for a variety of sensing applications. The miniaturized system is based on Chemical Identification by Magneto-Elastic Sensing (ChIMES) technology, which uses three concentric solenoid coils to wirelessly interrogate a sensor body comprised of a response material coupled to a magnetoelastic wire. The response material expands when it encounters a target, imposing mechanical stress on the wire and altering its magnetic permeability. The sensor bodies are passive, requiring no external power source, and they are small, measuring about 15 mm in length and 3.0 mm in diameter. Up to four sensor bodies can be configured as an evenly-spaced linear array. The sensor system operates by applying a low-frequency, current-stabilized, filtered triangle wave to a uniform-density excitation coil to switch the magnetic domains within the wire. Further, the responses from the sensors are picked up by a detection coil as stress-induced changes in the Faraday voltage, and the strong magnetic field induced by the excitation coil in the detection coil is nullified by a cancellation coil reverse-wound in series with the detection coil. The responses of the sensors in an array are separated in time by a linear gradient dc biasing coil. The sensors can be interrogated through metallic and nonmetallic barriers. The signals from the detection coil and the excitation coil are digitized by a pair of bipolar analog-to-digital converters (ADCs). A Raspberry Pi single-board computer (SBC) and associated software perform data acquisition and control all aspects of the sensor system hardware. The program allows the user to select the number of sensors in the array, the type of signal that is being collected, and the number of samples to take. The program also allows for signal processing of the sensor data, such as baseline correction. The program can differentiate sensor peaks from each other and calculate the magnitude of each sensor response with less than 1% error. The data are then displayed along with a graph of the signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Threading Libraries for High Performance Computing

With the appearance of multi-/many core machines, applications and runtime systems have evolved in order to exploit the new on-node concurrency brought by new software paradigms. POSIX threads (Pthreads) was widely-adopted for that purpose and it remains as the most used threading solution in current hardware. Lightweight thread (LWT) libraries emerged as an alternative offering lighter mechanisms to tackle the massive concurrency of current hardware. In this article, we analyze in detail the most representative threading libraries including Pthread- and LWT-based solutions. In addition, to examine the suitability of LWTs for different use cases, we develop a set of microbenchmarks consisting of OpenMP patterns commonly found in current parallel codes, and we compare the results using threading libraries and OpenMP implementations. Moreover, we study the semantics offered by threading libraries in order to expose the similarities among different LWT application programming interfaces and their advantages over Pthreads. This article exposes that LWT libraries outperform solutions based on operating system threads when tasks and nested parallelism are required.

GLT↗

Numerical modeling based machine learning approach for the optimization of falling - film evaporator in thermal desalination application

Scale formation that drastically increases thermal resistance and reduces freshwater production remains a critical challenge in thermal desalination. Novel designs of falling film evaporator and optimal operating condition hold great promise to mitigate scale formation, and increase heat transfer performance and fresh water production. In this work, CFD simulation based machine learning and multi-objective optimization are performed to identify optimal conditions and tube arrangement for evaporator. Non-dominated sorting genetic algorithm is adopted to determine and analyze the optimal pareto front for multiple objectives in desalination criteria. The errors of training, validation, and testing set are computed to identify an optimal hyperparameter set. For performance ratio, fouling resistance, and water production rate, the average relative error is 2.26%, 3.67%, and 3.24%. At pareto front, both performance ratio and water production rate increase at high temperature with fouling resistance (thermal resistance of the fouling layer) increasing as well. Tradeoffs between mitigating scale formation and enhancing desalination performance are evaluated in optimizations for different objectives. Finally, potential optima are identified and can be applied as guidelines to determine evaporator design and system operating conditions.

42 ENGINEERING↗