Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Jack Healy Remembers - Anecdotal Evidence for the Origin of the Approximate 24-hour Urine Sampling Protocol Used for Worker Bioassay Monitoring

The origin of the approximate 24-hour urine sampling protocol used at Hanford for routine bioassay is attributed to an informal study done in the mid-1940s. While the actual data were never published and have been lost, anecdotal recollections by staff involved in the initial bioassay program design and administration suggest that the sampling protocol had a solid scientific basis. Numerous alternate methods for normalizing partial day samples to represent a total 24-hour collection have since been proposed and used, but no one method is obviously preferred.

61 RADIATION PROTECTION AND DOSIMETRY↗

Efficient sampling for spatial uncertainty qualification in multibody system dynamics applications.

We present two methods for efficiently sampling the response (trajectory space) of multibody systems operating under spatial uncertainty, when the latter is assumed to be representable with Gaussian processes. In this case, the dynamics (time evolution) of the multibody systems depends on spatially indexed uncertain parameters that span infinite-dimensional spaces. This places a heavy computational burden on existing methodologies, an issue addressed herein with two new conditional sampling approaches. When a single instance of the uncertainty is needed in the entire domain, we use a fast Fourier transform technique. When the initial conditions are fixed and the path distribution of the dynamical system is relatively narrow, we use an incremental sampling approach that is fast and has a small memory footprint. Both methods produce the same distributions as the widely used Cholesky-based approaches. We illustrate this convergence at a smaller computational effort and memory cost for a simple non-linear vehicle model.

97 MATHEMATICS AND COMPUTING↗

Nanomechanical sampling of material for nanoscale mass spectrometry chemical analysis

The ability to spatially resolve the chemical distribution of compounds on a surface is important in many applications ranging from biological to material science. To this extent, we have recently introduced a hybrid atomic force microscopy (AFM)-mass spectrometry (MS) system for direct thermal desorption and pyrolysis of material with nanoscale chemical resolution. However, spatially resolved direct surface heating using local thermal desorption becomes challenging on material surfaces with low melting points, because the material will undergo a melting phase transition due to heat dissipation prior to onset of thermal desorption. Therefore, here we developed an approach using mechanical sampling and collection of surface materials on an AFM cantilever probe tip for real-time analysis directly from the AFM tip. This approach allows for material to be concentrated directly onto the probe for subsequent MS analysis. We evaluate the performance metrics of the technique and demonstrate localized MS sampling from a candelilla wax matrix containing UV stabilizers avobenzone and oxinoxate from areas down to 250 nm × 250 nm. Overall, this approach removes heat dissipation into the bulk material allowing for a faster desorption and concentration of the gas phase analyte from a single heating pulse enabling higher signal levels from a given amount of material in a single sampling spot.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical Methods for Identifying Hard Clay Core Samples During Petrophysical Studies

X-ray phase analysis of the general mineralogical composition of core samples from one of the West Siberian fields was performed. Electronic absorption spectra of the clay core samples with an added indicator were studied. The speed and availability of applying the two methods in petrophysical laboratories during sample preparation for standard and special studies were estimated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adaptive Sampling-Based Bi-Fidelity Stochastic Trust Region Method for Stochastic Derivative-Free Optimization

Bi-fidelity stochastic optimization has gained increasing attention as an efficient approach to reduce computational costs by leveraging a low-fidelity (LF) model to optimize an expensive high-fidelity (HF) objective. In this paper, we propose ASTRO-BFDF, an adaptive sampling trust-region method specifically designed for unconstrained bi-fidelity stochastic derivative-free optimization problems. In ASTRO-BFDF, the LF function serves two purposes: (i) to identify better iterates for the HF function when the optimization process indicates a high correlation between them and (ii) to reduce the variance of the HF function estimates using bi-fidelity Monte Carlo (BFMC). The algorithm dynamically determines sample sizes while adaptively choosing between crude Monte Carlo and BFMC to balance the trade-off between optimization and sampling errors. We prove that the iterates generated by ASTRO-BFDF converge to a first-order stationary point almost surely. Additionally, we demonstrate the effectiveness of the proposed algorithm through numerical experiments on synthetic benchmarks and simulation optimization problems involving discrete event systems.

97 MATHEMATICS AND COMPUTING↗

Preparation of a 73 As source sample for application in an offline ion source

For the generation of beams with the offline ion source at the Facility for Rare Isotope Beams (FRIB), suitable source samples are required. Arsenic-73 is a frequently requested user beam due to its significance in nuclear structure studies and astrophysics. In this work, we outline the process of preparing a 73 As source sample, containing (5.76 ± 0.37)∗10 14 atoms of 73 As, which was successfully used to generate a 73 As beam for a multi-day user experiment. Silver arsenate was chosen as the chemical form, due to its favorable volatility within the designated operating temperature range. We refined the precipitation method using stable arsenic prior to its application with the 73 As sample, resulting in precipitation yields of (99.4 ± 4.5)%.

As-73↗

A STUDY OF EXTRACTIVE AND REMOTE-SENSING SAMPLING AND MEASUREMENT OF EMISSIONS FROM MILITARY AIRCRAFT ENGINES

Aircraft emissions contribute to the increased atmospheric burden of particulate matter (e.g., black carbon and secondary organic compounds) that plays a role in air quality, contrail formation and climate change. Sampling and measurement of modern aircraft emissions at the engine exhaust plane (EEP) for to engine and fuel certification remains a daunting task, no agency-certified method is available for the task. In this paper we summarize the results of a recent study that was devoted to investigate both extractive and optical remote-sensing (ORS) technologies in sampling and measurement of gaseous and particulate matter (PM) emitted by a number of military aircraft engines operated with JP-8 and a Fischer-Tropsch (FT) fuel at various engine conditions. These engines include cargo, bomber, and helicopter types of military aircraft that consumes 70-80% of the military aviation fuel each year. The emission indices of selected pollutants are discussed as these data may be of interest for atmospheric modeling and for design of air quality control strategies around the airports and military bases. It was found that non-volatile particles in the engine emissions were all in the ultrafine range. The mean diameter of particles increased as the engine power increased; the mode diameters were in the 20nm range for the low power condition of a new helicopter engine to 80nm for the high power condition of a newly maintained bomber engine. Elemental analysis indicated little metals were present on particles in the exhaust, while most of the materials on the exhaust particles were based on carbon and sulfate. Carbon monoxide, carbon dioxide, nitrogen oxide, sulfur dioxide, formaldehyde, ethylene, acetylene, propylene, and alkanes were detected using both technologies. The last five species (in the air toxics category) were most noticeable only under the low engine power. The emission indices calculated based on the ORS data were however observed to differ significantly (up to 90%) from (typically lower than) those based on the extractive techniques. However, the ORS techniques were useful in providing non-intrusive real-time measurements of gaseous species in the exhaust plume, which warrants further development. The results obtained in this program validate sampling methodology and measurement techniques used for non-volatile PM aircraft emissions as described in the SAE AIR-6037.

54 ENVIRONMENTAL SCIENCES↗

Low-mass molecular dynamics simulation: A simple and generic technique to enhance configurational sampling

Highlights: • Reducing atomic masses by 10-fold vastly improves sampling in MD simulations. • CLN025 folded in 4 of 10 × 0.5-μs MD simulations when masses were reduced by 10-fold. • CLN025 folded as early as 96.2 ns in 1 of the 4 simulations that captured folding. • CLN025 did not fold in 10 × 0.5-μs MD simulations when standard masses were used. • Low-mass MD simulation is a simple and generic sampling enhancement technique. - Abstract: CLN025 is one of the smallest fast-folding proteins. Until now it has not been reported that CLN025 can autonomously fold to its native conformation in a classical, all-atom, and isothermal–isobaric molecular dynamics (MD) simulation. This article reports the autonomous and repeated folding of CLN025 from a fully extended backbone conformation to its native conformation in explicit solvent in multiple 500-ns MD simulations at 277 K and 1 atm with the first folding event occurring as early as 66.1 ns. These simulations were accomplished by using AMBER forcefield derivatives with atomic masses reduced by 10-fold on Apple Mac Pros. By contrast, no folding event was observed when the simulations were repeated using the original AMBER forcefields of FF12SB and FF14SB. The results demonstrate that low-mass MD simulation is a simple and generic technique to enhance configurational sampling. This technique may propel autonomous folding of a wide range of miniature proteins in classical, all-atom, and isothermal–isobaric MD simulations performed on commodity computers—an important step forward in quantitative biology.

60 APPLIED LIFE SCIENCES↗

Proteomic analysis of minute amount of colonic biopsies by enteroscopy sampling

Colorectal cancer (CRC) is one of the most common types of malignant tumor worldwide. Currently, although many researchers have been devoting themselves in CRC studies, the process of locating biomarkers for CRC early diagnosis and prognostic is still very slow. Using a centrifugal proteomic reactor-based proteomic analysis of minute amount of colonic biopsies by enteroscopy sampling, 2620 protein groups were quantified between cancer mucosa and adjacent normal colorectal mucosa. Of which, 403 protein groups were differentially expressed with statistic significance between cancer and normal tissues, including 195 up-regulated and 208 down-regulated proteins in cancer tissues. Three proteins (SOD3, PRELP and NGAL) were selected for further Western blot validation. And the resulting Western blot experimental results were consistent with the quantitative proteomic data. SOD3 and PRELP are down-regulated in CRC mucosa comparing to adjacent normal tissue, while NGAL is up-regulated in CRC mucosa. In conclusion, the centrifugal proteomic reactor-based label-free quantitative proteomic approach provides a highly sensitive and powerful tool for analyzing minute protein sample from tiny colorectal biopsies, which may facilitate CRC biomarkers discovery for diagnoses and prognoses. -- Highlights: •Minute amount of colonic biopsies by endoscopy is suitable for proteomic analysis. •Centrifugal proteomic reactor can be used for processing tiny clinic biopsy sample. •SOD3 and PRELP are down-regulated in CRC, while NGAL is up-regulated in CRC.

60 APPLIED LIFE SCIENCES↗

Variable resolution Poisson-disk sampling for meshing discrete fracture networks

Here, we present the near-Maximal Algorithm for Poisson-disk Sampling (nMAPS) to generate point distributions for variable resolution Delaunay triangular and tetrahedral meshes in two and three-dimensions, respectively. nMAPS consists of two principal stages. In the first stage, an initial point distribution is produced using a cell-based rejection algorithm. In the second stage, holes in the sample are detected using an efficient background grid and filled in to obtain a near-maximal covering. Extensive testing shows that nMAPS generates a variable resolution mesh in linear run time with the number of accepted points. We demonstrate nMAPS capabilities by meshing three-dimensional discrete fracture networks (DFN) and the surrounding volume. The discretized boundaries of the fractures, which are represented as planar polygons, are used as the seed of 2D-nMAPS to produce a conforming Delaunay triangulation. The combined mesh of the DFN is used as the seed for 3D-nMAPS, which produces conforming Delaunay tetrahedra surrounding the network. Under a set of conditions that naturally arise in maximal Poisson-disk samples and are satisfied by nMAPS, the two-dimensional Delaunay triangulations are guaranteed to only have well-behaved triangular faces. While nMAPS does not provide triangulation quality bounds in more than two dimensions, we found that low-quality tetrahedra in 3D are infrequent, can be readily detected and removed, and a high-quality balanced mesh is produced.

97 MATHEMATICS AND COMPUTING↗

Induction of IL-6 and inhibition of IL-8 secretion in the human airway cell line Calu-3 by urban particulate matter collected with a modified method of PM sampling

Exposure to particulate matter (PM) induces inflammatory cytokines. In the present study, we evaluated the secretion of IL-6 and IL-8 by an airway cell line exposed to PM with a mean aerodynamic size equal to or less than 10 or 2.5 {mu}m (PM{sub 10} and PM{sub 2.5}, respectively) collected in Mexico City, using a modified high-volume sampling method avoiding the use of solvents or introducing membrane components into the samples. PM was collected on cellulose-nitrate (CN) membranes modified for collection on high-volume samplers. Composition of the particles was evaluated by particle-induced X-ray emission (PIXE) and scanning electron microscopy. The particles (10-160 {mu}g/cm{sup 2}) were tested on Calu-3 cells. Control cultures were exposed to LPS (10 ng/mL to 100 {mu}g/mL) or silica (10-160 {mu}g/cm{sup 2}). IL-6 and IL-8 secretions were evaluated by ELISA. An average of 10 mg of PM was recovered form each cellulose-nitrate filter. No evidence of contamination from the filter was found. Cells exposed to PM{sub 10} presented an increase in the secretion of IL-6 (up to 400%), while IL-8 decreased (from 40% to levels below the detection limit). A similar but weaker effect was observed with PM{sub 2.5}. In conclusion, our modified sampling method provides a large amount of urban PM free of membrane contamination. The urban particles induce a decrease in IL-8 secretion that contrasts with the LPS and silica effects. These results suggest that the regulation of IL-8 expression is different for urban particles (complex mixture containing combustion-related particles, soil and biologic components) than for biogenic compounds or pure mineral particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Danish contribution to the European DEMOCOPHES project: A description of cadmium, cotinine and mercury levels in Danish mother-child pairs and the perspectives of supplementary sampling and measurements

Human biomonitoring (HBM) is an important tool, increasingly used for measuring true levels of the body burdens of environmental chemicals in the general population. In Europe, a harmonized HBM program was needed to open the possibility to compare levels across borders. To explore the prospect of a harmonized European HBM project, DEMOCOPHES (DEMOnstration of a study to COordinate and Perform Human biomonitoring on a European Scale) was completed in 17 European countries. The basic measurements performed in all implemented countries of DEMOCOPHES included cadmium, cotinine and phthalate metabolites in urine and mercury in hair. In the Danish participants, significant correlations between mothers and children for mercury in hair and cotinine in urine were found. Mercury in hair was further significantly associated with intake of fish and area of residence. Cadmium was positively associated with BMI in mothers and an association between cadmium and cotinine was also found. As expected high cotinine levels were found in smoking mothers. For both mercury and cadmium significantly higher concentrations were found in the mothers compared to their children. In Denmark, the DEMOCOPHES project was co-financed by the Danish ministries of health, environment and food safety. The co-financing ministries agreed to finance a number of supplementary measurements of substances of current toxicological, public and regulatory interest. This also included blood sampling from the participants. The collected urine and blood samples were analyzed for a range of other persistent and non-persistent environmental chemicals as well as two biomarkers of effect. The variety of supplementary measurements gives the researchers further information on the exposure status of the participants and creates a basis for valuable knowledge on the pattern of exposure to various chemicals. - Highlights: • Levels of cadmium, mercury and cotinine in the Danish subpopulation are comparable to levels in the total DEMOCOPHES population with mercury in hair above the European median. • Supplementary sample collection and measurements in Denmark gave valuable exposure information on a variety of other chemicals of current toxicological, public and regulatory interest, such as persistent organic pollutants. • It is highly valuable to obtain as much exposure information as possible once you have established the study cohort.

54 ENVIRONMENTAL SCIENCES↗

Optimal PMU design based on sampling model and sensitivity analysis

The precise measurements of the synchrophasor and frequency from phasor measurement units (PMUs) are widely used in power grid applications. With the improvement of the technique, applications always require stable dynamic performance and higher accuracy for the synchrophasor and frequency measurements, which is challenging for PMU development. To evaluate the contribution of PMU hardware to measurement accuracy, this paper proposes a general-purpose sampling model to analyze the measurement error. In the proposed sampling model, a strict mathematical derivation is derived, where its error is purely determined by the parameters of the PMU hardware. The sensitivity analysis is carried out by three methods, including mathematical analysis, computer simulation, and variance-based sensitivity analysis. Through the sensitivity analysis, this paper establishes the systematic formulation and the inclusion of synchrophasor, frequency, and ROCOF. Experimental results based on the real-world testbench involving distribution-level PMUs match the mathematical analysis conclusion, which verifies the correctness of the general-purpose sampling model. Furthermore, a strategy for the optimal PMU design is proposed, which could guide PMU design in the future.

42 ENGINEERING↗

Optimizing 4-Dimensional Magnetic Resonance Imaging Data Sampling for Respiratory Motion Analysis of Pancreatic Tumors

Purpose: To determine the optimum sampling strategy for retrospective reconstruction of 4-dimensional (4D) MR data for nonrigid motion characterization of tumor and organs at risk for radiation therapy purposes. Methods and Materials: For optimization, we compared 2 surrogate signals (external respiratory bellows and internal MRI navigators) and 2 MR sampling strategies (Cartesian and radial) in terms of image quality and robustness. Using the optimized protocol, 6 pancreatic cancer patients were scanned to calculate the 4D motion. Region of interest analysis was performed to characterize the respiratory-induced motion of the tumor and organs at risk simultaneously. Results: The MRI navigator was found to be a more reliable surrogate for pancreatic motion than the respiratory bellows signal. Radial sampling is most benign for undersampling artifacts and intraview motion. Motion characterization revealed interorgan and interpatient variation, as well as heterogeneity within the tumor. Conclusions: A robust 4D-MRI method, based on clinically available protocols, is presented and successfully applied to characterize the abdominal motion in a small number of pancreatic cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimation of distributions via multilevel Monte Carlo with stratified sampling

We design and implement a novel algorithm for computing a multilevel Monte Carlo (MLMC) estimator of the joint cumulative distribution function (CDF) of a vector-valued quantity of interest in problems with random input parameters and initial conditions. Our approach combines MLMC with stratified sampling of the input sample space by replacing standard Monte Carlo at each level with stratified Monte Carlo initialized with proportionally allocated samples. We show that the resulting stratified MLMC (sMLMC) algorithm is more efficient than its standard MLMC counterpart due to the additional variance reduction provided by the stratification of the random parameter's domain, especially at the coarsest levels. Additional computational cost savings are obtained by smoothing the indicator function with a Gaussian kernel, which proves to be an efficient and robust alternative to recently developed polynomial-based techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sample preparation methods for scanning electron microscopy of homogenized Al-Mg-Si billets: A comparative study

Characterization of Mg-Si precipitates is crucial for optimizing the homogenization heat treatment of Al-Mg-Si alloys. Although sample preparation is key for high quality scanning electron microscopy imaging, most common methods lead to dealloying of Mg-Si precipitates. In this article we systematically evaluate different sample preparation methods: mechanical polishing, etching with various reagents, and electropolishing using different electrolytes. We demonstrate that the use of a nitric acid and methanol electrolyte for electropolishing a homogenized Al-Mg-Si alloy prevents the dissolution of Mg-Si precipitates, resulting in micrographs of higher quality. This preparation method is investigated in depth and the obtained scanning electron microscopy images are compared with transmission electron micrographs: the shape and size of Mg-Si precipitates appear very similar in either method. The scanning electron micrographs allow proper identification and measurement of the Mg-Si phases including needles with lengths of roughly 200 nm. These needles are β″ precipitates as confirmed by high resolution transmission electron microscopy. - Highlights: •Secondary precipitation in homogenized 6xxx Al alloys is crucial for extrudability. •Existing sample preparation methods for SEM are improvable. •Electropolishing with nitric acid/methanol yields superior quality in SEM. •The obtained micrographs are compared to TEM micrographs.

36 MATERIALS SCIENCE↗

Modulating Electron Beam–Sample Interactions in Imaging and Diffraction Modes by Dose Fractionation with Low Dose Rates

Abstract Technological opportunities are explored to enhance detection schemes in transmission electron microscopy (TEM) that build on the detection of single-electron scattering events across the typical spectrum of interdisciplinary applications. They range from imaging with high spatiotemporal resolution to diffraction experiments at the window to quantum mechanics, where the wave-particle dualism of single electrons is evident. At the ultimate detection limit, where isolated electrons are delivered to interact with solids, we find that the beam current dominates damage processes instead of the deposited electron charge, which can be exploited to modify electron beam-induced sample alterations. The results are explained by assuming that all electron scattering are inelastic and include phonon excitation that can hardly be distinguished from elastic electron scattering. Consequently, a coherence length and a related coherence time exist that reflect the interaction of the electron with the sample and change linearly with energy loss. Phonon excitations are of small energy (<100 meV), but they occur frequently and scale with beam current in the irradiated area, which is why we can detect their contribution to beam-induced sample alterations and damage.

47 OTHER INSTRUMENTATION↗

Automated Separation of Uranium and Plutonium from Environmental Swipe Samples for Multiple Collector Inductively Coupled Plasma Mass Spectrometry

A fully automated method for the separation of low-concentration uranium from plutonium in environmental swipe samples has been developed. The offline chromatography system features renewable 1 mL Eichrom TEVA and UTEVA column generation from bulk resin slurry. Discrete fractions of the separated actinides are delivered into user defined vials for future analysis. Clean room background levels were achieved outside of a cleanroom environment with this method. Purification of uranium and plutonium from various sample matrixes and at various concentrations was successful. Major and minor isotope ratios for both elements were measured via multiple collector inductively coupled plasma mass spectrometry and were in good agreement with certified reference values. Lastly, validation of the separation method was conducted on archived environmental samples and agreed with values previously reported using standard column chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗