Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Bandgap profiling in CIGS solar cells via valence electron energy-loss spectroscopy

A robust, reproducible method for the extraction of relative bandgap trends from scanning transmission electron microscopy (STEM) based electron energy-loss spectroscopy (EELS) is described. The effectiveness of the approach is demonstrated by profiling the bandgap through a CuIn 1-x Ga x Se 2 solar cell that possesses intentional Ga/(In + Ga) composition variation. The EELS-determined bandgap profile is compared to the nominal profile calculated from compositional data collected via STEM-based energy dispersive X-ray spectroscopy. The EELS based profile is found to closely track the calculated bandgap trends, with only a small, fixed offset difference. This approach, which is particularly advantageous for relatively narrow bandgap materials and/or STEM systems with modest resolution capabilities (i.e., >100 meV), compromises absolute accuracy to provide a straightforward route for the correlation of local electronic structure trends with nanoscale chemical and physical structure/microstructure within semiconductor materials and devices.

14 SOLAR ENERGY↗

Relative intensity calibration of the DIII-D charge-exchange recombination spectroscopy system using neutral beam injection into gas

A new calibration method for the DIII-D charge-exchange spectroscopy system produces a smoother impurity density profile compared to previous techniques, thus improving the accuracy of the impurity density profile reconstruction. The relative intensity calibration between the chords of the DIII-D charge-exchange recombination spectroscopy system is performed by firing neutral beams into the evacuated vacuum vessel pre-filled with neutral gas. Relative calibration is required in order to account for uncertainty in the 3D geometry of the neutral beam. Previous methods using helium gas have been improved by using xenon, which emits an emission line close to the commonly used carbon wavelength 5290.5 Å, as well as improved timing of the gas injection, inclusion of variations in the vessel pressure, and timing of neutral beam injection. Photoemission spectra recorded by 112 sightlines viewing 6 neutral beams are compared and used to form a relative calibration factor for each sightline. This relative calibration is shown to improve the quality of the measured ion density profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operando study of Pd(100) surface during CO oxidation using ambient pressure x-ray photoemission spectroscopy

The surface chemical states of Pd(100) during CO oxidation were investigated using ambient pressure x-ray photoelectron spectroscopy and mass spectroscopy. Under the reactant ratio of CO/O 2 = 0.1, i.e. an oxygen-rich reaction condition, the formation of surface oxides was observed with the onset of CO oxidation reaction at T = 525 K. As the reactant ratio (CO/O 2 ) increased from 0.1 to 1.0, ~ 90 % surface oxides remains on surface during the reaction. Upon the formation of surface oxides, the core level shift of oxygen gas phase peak was observed, indicating that change of surface work function. As CO oxidation takes places, i.e. making a transition from CO covered surface to the oxidic surface, the work functions of surface oxide on Pd(100) and Pt(110) display opposite behavior.

36 MATERIALS SCIENCE↗

Monitoring the growth dynamics of colloidal gold-silver core-shell nanoparticles using in situ second harmonic generation and extinction spectroscopy

The growth dynamics of gold-silver core-shell (Au@Ag) nanoparticles are studied using in situ time-dependent second harmonic generation (SHG) and extinction spectroscopy to investigate the nanoparticle shell formation. The silver shell is grown by reduction of silver cations onto a 14 nm gold core using ascorbic acid in colloidal aqueous solution under varying reaction concentrations producing Au@Ag nanoparticles of final sizes ranging from 51 to 78 nm in diameter. The in situ extinction spectra show a rapid increase in intensity on the timescale of 5–6 s with blue shifting and narrowing of the plasmonic peak during the silver shell formation. The in situ SHG signals show an abrupt rise at early times of the reaction, followed by a time-dependent biexponential decrease, where the faster SHG lifetime corresponds to the timescale of the shell growth, and where the slower SHG lifetime is attributed to changes in the nanoparticle surface charge density. A large enhancement in the SHG signal at early stages of the reaction is caused by plasmonic hot spots due to the nanoparticle surface morphology, which becomes smoother as the reaction proceeds. The final extinction spectra are compared to finite-difference time-domain (FDTD) calculations, showing general agreement with experiment, where the plasmon peak red shifts and increases in spectral width as the silver shell thickness increases. These in situ SHG and extinction spectroscopy results, combined with FDTD calculations, help characterize the complicated processes involved in colloidal nanoparticle shell formation in real time for developing potential plasmon-enhanced nanomaterial applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic-bottle and velocity-map imaging photoelectron spectroscopy of APS- (A = C14H10 or anthracene): electron structure, spin-orbit coupling of APS•, and dipole-bound state of APS-

Gaseous dibenzo-7-phosphanorbornadiene P-sulfide anions APS- (A = C14H10 or anthracene) were generated via electrospray ionization, and characterized by magnetic-bottle photoelectron spectroscopy, velocity-map imaging (VMI) photoelectron spectroscopy, and quantum chemical calculations. The electron affinity (EA) and spin-orbit splitting (SO) of the APS• radical are determined from the photoelectron spectra and Franck-Condon factor simulations to be EA = 2.62 ± 0.05 eV and SO splitting = 43 ± 7 meV. VMI photoelectron images show strong and sharp peaks near detachment threshold with an identical electron kinetic energy (eKE) of 17.9 meV at three different detachment wavelengths, which are therefore assigned due to autodetachment from dipole-bound anion states. The B3LYP/6-31++g(d,p) calculations indicate APS• has a dipole moment of 3.31 Debye, large enough to support a dipole-bound electron.

Dibenzo-7-phosphanorbornadiene P-sulfide, electron↗

Excited-state dynamics of CH 2 I 2 and CH 2 IBr studied with UV-pump VUV-probe momentum-resolved photoion spectroscopy

We perform time-resolved ionization spectroscopy measurements of the excited state dynamics of CH 2 I 2 and CH 2 IBr following photoexcitation in the deep UV. The fragment ions produced by ionization with a vacuum-ultraviolet probe pulse are measured with velocity map imaging, and the momentum resolved yields are compared with trajectory surface hopping calculations of the measurement observable. Together with recent time-resolved photoelectron spectroscopy measurements of the same dynamics, these results provide a detailed picture of the coupled electronic and nuclear dynamics involved. Overall, our measurements highlight the non-adiabatic coupling between electronic states, which leads to notable differences in the dissociation dynamics for the two molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polyvinyl acetate-based polymer host for optical and far-infrared spectroscopy of individualized nanoparticles

Preparation techniques for producing films of individualized solution-dispersed nanoparticles (NPs) for optical spectroscopy are frequently technically challenging and tailored for a specific NP system. In this work, we present a rapid, easy, and economical technique for producing polyvinyl acetate (PVAc)-based NP-polymer films on the order of 100’s of micrometers thick that exhibit high uniformity, low aggregation, excellent optical transparency, and low terahertz absorption. In addition, we find that these films are robust at cryogenic temperatures and have a high laser damage threshold of 0.3 TW cm –2 , which make them suitable for pulsed laser measurements. We show that free-standing, flexible, PVAc films can incorporate both one-dimensional single-wall carbon nanotubes (SWCNTs) and zero-dimensional Au NPs. Using absorbance, Raman scattering, and photoluminescence excitation spectroscopy, we observe that SWCNT individualization is maintained, and minimized polymer strain imposed, when the nanotubes are transitioned from the solution to the polymer host. This PVAc-based polymer host presents researchers with a straightforward method for producing free-standing and flexible NP films with low aggregation.

36 MATERIALS SCIENCE↗

Phase noise limited frequency shift impulsive Raman spectroscopy

We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.

47 OTHER INSTRUMENTATION↗

Electronic structure of NdO via slow photoelectron velocity-map imaging spectroscopy of NdO –

Electronically excited NdO is a possible product of the chemistry associated with the release of Nd into the ionosphere, and emission from these states may contribute to the observations following such experiments. To better characterize the energetics and spectroscopy of NdO, we report a combined experimental and theoretical study using slow photoelectron velocity-map imaging spectroscopy of cryogenically cooled NdO – anions (cryo-SEVI) supplemented by wave function-based quantum-chemical calculations. Using cryo-SEVI, we measure the electron affinity of NdO to be 1.0091(7) eV and resolve numerous transitions to low-lying electronic and vibrational states of NdO that are assigned with the aid of the electronic structure calculations. Additionally, temperature-dependent data suggest contributions from the (2)4.5 state of NdO – residing 2350 cm –1 above the ground anion state. Finally, photodetachment to higher-lying excited states of NdO is also reported, which may help to clarify observations from prior release experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-species temperature and number density analysis of a laser-produced plasma using dual-comb spectroscopy

Dual-comb spectroscopy (DCS) represents a novel method of using absorption spectroscopy as a diagnostic tool for multispecies analysis of excitation temperatures and column densities in laser-produced plasmas (LPPs). DCS was performed on a LPP generated by ablating a multielement alloy containing Nd, Gd, and Fe. Transitions from all three elements were observed in absorption spectra measured from 530.08 to 535.19 nm at seven time-delays from 31 to 250 μs after ablation. The spectra were fit using a nonlinear regression algorithm to determine peak areas, and excitation temperatures and column densities were determined for the three atomic species separately using Boltzmann plots. The measured excitation temperatures of Nd I and Gd I showed good agreement at all time-delays, whereas the Fe I temperature was found to be higher, and the ratios between the column densities varied with delay. The observations are understood via effects of LPP spatial averaging, elemental fractionation, and molecular formation and are compared and contextualized with previous work studying LPPs using other spectroscopic techniques. A brief discussion of the precision and accuracy of the determined excitation temperatures and column densities is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evidence of excited-state lifetime enhancement in dimyristoyl-phosphocholine nanodiscs by ultraviolet absorption spectroscopy

Ultraviolet absorption spectroscopy is an analytical tool that is commonly utilized to determine protein concentrations, primarily due to characteristic absorption of tryptophan and tyrosine at 280 nm. Accurate concentration determination is essential to the accuracy of many biophysical techniques, and ultraviolet absorption provides a convenient and rapid method to assess protein concentration. However, the widespread usage of this method assumes that ultraviolet absorption is the same for individual amino acids in aqueous solution (where the molar extinction coefficient was measured) as for the amino acid in the conformational environment of the protein of interest. We demonstrate that additional considerations may be necessary for the membrane scaffold protein in dimyristoyl-phosphocholine nanodiscs through ultraviolet absorption spectroscopy of nanodiscs, liposomes, the membrane scaffold protein, and a mixture of liposomes and the non-nanodisc-associated protein. The aromatic amino acids of the membrane scaffold protein absorb significantly less light at 280 nm when associated with lipids in a lipoprotein assembly, which we plausibly attribute to an enhancement of chromophore excited-state lifetimes due to reduced intramolecular motion in the nanodisc. We caution that using the molar absorptivity of the membrane scaffold protein alone to determine nanodisc concentrations may not yield accurate results. Instead, the molar absorptivity of each nanodisc formulation should be explored independently to account for the unique conformational environment of each nanodisc.

59 BASIC BIOLOGICAL SCIENCES↗

Perturbative theoretical model of electronic transient circular dichroism spectroscopy of molecular aggregates

A chiral analog of transient absorption spectroscopy, transient circular dichroism (TCD) spectroscopy is an emerging time-resolved method. Both spectroscopic methods can probe the electronic transitions of a sample, and TCD is additionally sensitive to the dynamic aspects of chirality, such as those induced by molecular excitons. Here, we develop a theoretical description of TCD for electronic multi-level models in which the pump pulse is linearly polarized and probe pulse is alternately left- and right-circularly polarized. We derive effective response functions analogous to those often used to describe other four-wave mixing methods and then simulate and analyze TCD spectra for three representative multi-level electronic model systems. We elaborate on the presence and detection of the spectral signatures of electronic coherences.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Polarized tip-enhanced Raman spectroscopy at liquid He temperature in ultrahigh vacuum using an off-axis parabolic mirror

Tip-enhanced Raman spectroscopy (TERS) combines inelastic light scattering well below the diffraction limit down to the nanometer range and scanning probe microscopy and, possibly, spectroscopy. In this way, topographic and spectroscopic as well as single- and two-particle information may simultaneously be collected. While single molecules can now be studied successfully, bulk solids are still not meaningfully accessible. It is the purpose of the work presented here to outline approaches toward this objective. We describe a home-built, liquid helium cooled, ultrahigh vacuum TERS. The setup is based on a scanning tunneling microscope and, as an innovation, an off-axis parabolic mirror having a high numerical aperture of ~0.85 and a large working distance. The system is equipped with a fast load-lock chamber, a chamber for the in situ preparation of tips, substrates, and samples, and a TERS chamber. Base pressure and temperature in the TERS chamber were ~3 × 10 –11 mbar and 15 K, respectively. Polarization dependent tip-enhanced Raman spectra of the vibration modes of carbon nanotubes were successfully acquired at cryogenic temperature. The new features described here including very low pressure and temperature and the external access to the light polarizations, thus the selection rules, may pave the way toward the investigation of bulk and surface materials.

47 OTHER INSTRUMENTATION↗

Observation of laser ablation of silicon as a function of pulse length at constant fluence via time-resolved x-ray spectroscopy

We investigate the ablation of silicon as a function of laser pulse length at a constant fluence using time-resolved x-ray spectroscopy data obtained from OMEGA EP experiments at the University of Rochester's Laboratory for Laser Energetics. Our targets consisted of three-layer planar structures composed of Si (50 μm), Cu (25 μm), and SiO 2 (500 μm) layers. The Si layer was irradiated by a 351-nm laser with varying pulse widths of 250 ps, 500 ps, 1 ns, and 10 ns while maintaining a constant fluence of ~27.9 kJ/cm 2 . Electron temperatures and densities of the ablated plasma were determined by analyzing the time-resolved x-ray spectroscopy data through a comparison of experimental measurements with synthetic results obtained from Si atomic calculations in a steady state and non-local thermodynamic equilibrium. These calculations were computed using PrismSPECT. Additionally, radiation-hydrodynamics simulations with FLASH are used to generate simulated plasma-density and plasma-temperature profiles, which are then compared with the experimental measurements. Our analyses reveal that increasing the laser pulse length at a constant fluence results in a decrease in electron temperatures and densities. Furthermore, the longer pulses with lower intensities lead to deeper ablation regions before reaching the peak ablation but lower ionization balances in the silicon layer. Furthermore, these findings emphasize the critical role of laser pulse length in plasma ablation and shock generation for laser-impulse studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Twins in rotational spectroscopy: Does a rotational spectrum uniquely identify a molecule?

Rotational spectroscopy is the most accurate method for determining structures of molecules in the gas phase. It is often assumed that a rotational spectrum is a unique “fingerprint” of a molecule. The availability of large molecular databases and the development of artificial intelligence methods for spectroscopy make the testing of this assumption timely. In this paper, we pose the determination of molecular structures from rotational spectra as an inverse problem. Within this framework, we adopt a funnel-based approach to search for molecular twins, which are two or more molecules, which have similar rotational spectra but distinctly different molecular structures. Here we demonstrate that there are twins within standard levels of computational accuracy by generating rotational constants for many molecules from several large molecular databases, indicating that the inverse problem is ill-posed. However, some twins can be distinguished by increasing the accuracy of the theoretical methods or by performing additional experiments.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hiding in plain sight: The prevalence and impact of trions and Fermi polarons in transient absorption spectroscopy experiments of 2D semiconductors

Transient absorption (TA) spectroscopy is one of the most popular experimental methods to measure the excited state lifetimes and charge carrier recombination mechanisms in two dimensional (2D) semiconductors. This fundamental information is essential for designing and optimizing the next generation of ultrathin and lightweight 2D semiconductor-based optoelectronic devices. However, the interpretation of TA spectroscopy data varies across the community. The community lacks a unifying physical explanation for how and why experimental variables such as incident light intensity, sample-substrate interactions, and/or applied bias affect TA spectral data. This Perspective (1) compares the physical chemistry TA literature to nanomaterial physics literature from a historical perspective, (2) reviews multiple physical explanations that the TA community developed to explain spectral features and experimental trends, (3) provides a unifying explanation for how and why trions—and, more generally, Fermi polarons—contribute to TA spectra, and (4) quantifies the extent to which various physical interpretations and data analysis procedures yield different timescales and mechanisms for the same set of experimental results. We highlight the importance of considering trions/Fermi polarons in TA measurements and their implications for advancing our understanding of 2D material properties.

2D materials↗

An interactive machine learning platform for analyzing multi-particle coincidence data from cold target recoil ion momentum spectroscopy

We present SCULPT (Supervised Clustering and Uncovering Latent Patterns with Training), a comprehensive software platform for analyzing tabulated high-dimensional multi-particle coincidence data from Cold Target Recoil Ion Momentum Spectroscopy (COLTRIMS) experiments. The software addresses critical challenges in modern momentum spectroscopy by integrating advanced machine learning techniques with physics-informed analysis in an interactive web-based environment. SCULPT implements uniform manifold approximation and projection for non-linear dimensionality reduction to reveal correlations in high-dimensional data. We also discuss potential extensions to deep autoencoders for feature learning and genetic programming for automated discovery of physically meaningful observables. A novel adaptive confidence scoring system provides quantitative reliability assessments by evaluating user-selected clustering quality metrics with predefined weights that reflect each metric’s robustness. The platform features configurable molecular profiles for different experimental systems, interactive visualization with selection tools, and comprehensive data filtering capabilities. Utilizing a subset of SCULPT’s capabilities, we analyze photo-double-ionization data measured using the COLTRIMS method for three-body dissociation of the D 2 O molecule, revealing distinct fragmentation channels and their correlations with physics parameters. The software’s modular architecture and web-based implementation make it accessible to the broader atomic and molecular physics community, significantly reducing the time required for complex multi-dimensional analyses. This opens the door to finding and isolating rare events exhibiting non-linear correlations on the fly during experimental measurements, which can help steer exploration and improve the efficiency of experiments.

Artificial neural networks↗

Terahertz time-domain spectroscopy of biological tissues

Terahertz absorption spectra and dispersion of biologically important substances such as sugar, water, hemoglobin, lipids and tissues are studied. The characteristic absorption lines in the frequency range of a terahertz spectrometer (0.1-3.5 THz) are found. The refraction indices and absorption coefficients of human tooth enamel and dentine are measured. The method of terahertz phase reflection spectroscopy is developed for strongly absorbing substances. Simple and reliable methods of time-resolved terahertz spectroscopy are developed. (biophotonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗