Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Cryogenic goniometer for measurements in pulsed magnetic fields fabricated via additive manufacturing technique

Complex high-precision mechanical devices can be fabricated using 3-dimensional printing technology with the help of computer-aided design. Using 3D stereolithography, we have constructed a cryogenic goniometer for measurements in pulsed magnetic fields of up to 100 T, at temperatures as low as 0.5 K. We review the properties of several materials tested in developing the goniometer and report on its design and performance. The goniometer allows samples to be rotated in situ to a precision of 0.2 deg, so that the field can be applied at many different angles to the samples’ symmetry directions. Following its success, we establish that 3D printing is now a viable technology for pulsed-field and other cryogenic probes.

3D printing↗

Proximity-induced magnetism and the enhancement of damping in ferromagnetic/heavy metal systems

The relationship between proximity-induced magnetism (PIM) at the heavy metal/ferromagnet interface and spin-transport across such interfaces has generated significant debate. To investigate the link between the two, element specific x-ray magnetic circular dichroism and ferromagnetic resonance measurements were made on the same CoFe/Au/Pt and NiFe/Au/Pt thin film samples with varying Au thickness, with complementary SIMS analysis, which shows evidence of Ni diffusion from NiFe into the Pt. An approximately linear relationship is observed between the magnitude of Pt PIM and magnitude of damping enhancement in both systems. The results demonstrate that electronic hybridization of the heavy metal and ferromagnet is required for a full understanding of damping enhancement and interfacial spintransport for spintronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sixteen multiple-amplifier sensing charge-coupled devices and characterization techniques targeting the next generation of astronomical instruments

We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ∼1 erms− with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.

16 multiple-amplifer sensing CCD (MAS-CCD)↗

Magnetically coupled loading chamber and apparatus for in situ MAS NMR: operating under either high or low pressure

A sample chamber holder for MAS-NMR capable of operating at both low and high pressures. In one example the sample chamber holder is made up of a sample holder body defining a sample chamber therein, a connector configured to operatively statically hold an in situ rotor within the sample chamber; a coupler configured to operatively connect the sampler holder body to a magnetically coupled rotation member. The magnetically coupled rotation member is configured to engage and rotate a sealing cap from an NMR rotor in such a way so as to allow an NMR cap to be alternatively opened or sealed in-situ while the NMR rotor remains statically positioned in an NMR device.

Hu, Jian Z.↗

Current-carrying element based on second-generation high-temperature superconductor for the magnet system of a fusion neutron source

Application of current-carrying elements (CCEs) made of second-generation high-temperature superconductor (2G HTS) in magnet systems of a fusion neutron source (FNS) and other fusion devices will allow their magnetic field and thermodynamic stability to be increased substantially in comparison with those of low-temperature superconductor (LTS) magnets. For a toroidal magnet of the FNS, a design of a helical (partially transposed) CCE made of 2G HTS is under development with forced-flow cooling by helium gas, a current of 20–30 kA, an operating temperature of 10–20 K, and a magnetic field on the winding of 12–15 T (prospectively ∼20 T). Short-sized samples of the helical flexible heavy-current CCE are being fabricated and investigated; a pilot-line unit for production of long-sized CCE pieces is under construction. The applied fabrication technique allows the CCE to be produced which combines a high operating current, thermal and mechanical stability, manufacturability, and low losses in the alternating modes. The possibility of fabricating the CCE with the outer dimensions and values of the operating parameter required for the FNS (and with a significant margin) using already available serial 2G HTS tapes is substantiated. The maximum field of toroidal magnets with CCEs made of 2G HTS will be limited only by mechanical properties of the magnet’s casing and structure, while the thermal stability will be approximately two orders of magnitude higher than that of toroidal magnets with LTS-based CCEs. The helical CCE made of 2G HTS is very promising for fusion and hybrid electric power plants, and its design and technologies of production, as well as the prototype coils made of it for the FNS and other tokamaks, are worth developing now.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Construction of Eu2+ doped H3Sr6(PO4)5·2H2O with novel cruciate multilayer microarchitectures: facile hydrothermal synthesis, growth mechanism, and luminescence properties

Highlights: • H{sub 3}Sr{sub 6}(PO{sub 4}){sub 5}·2H{sub 2}O:Eu{sup 2+} phosphors were synthesized via a simple hydrothermal method. • H{sub 3}Sr{sub 6}(PO{sub 4}){sub 5}·2H{sub 2}O:Eu{sup 2+} showed novel cruciate multilayer microarchitectures. • Phase and morphology were depended on the optimization of the reaction conditions. • H{sub 3}Sr{sub 6}(PO{sub 4}){sub 5}·2H{sub 2}O:Eu{sup 2+} exhibited intense characteristic blue emission of Eu{sup 2+}. - Abstract: A series of monodisperse cruciate multilayer H{sub 3}Sr{sub 6}(PO{sub 4}){sub 5}·2H{sub 2}O:Eu{sup 2+} microarchitectures assembled by crossed nanorods have been successfully synthesized via a facile surfactant-assisted hydrothermal route. XRD and FT-IR confirmed the existence of crystalline water in the phosphor. The FE-SEM images revealed that the phase and morphology of resulting samples were strongly depended on the optimization of the reaction conditions, especially the pH value and the molar ratio of citric acid (CA)/Cations. Furthermore, the possible growth mechanism of H{sub 3}Sr{sub 6}(PO{sub 4}){sub 5}·2H{sub 2}O:Eu{sup 2+} microarchitectures was proposed in detail. Under near-ultraviolet excitation of 365 nm, the as-obtained H{sub 3}Sr{sub 6}(PO{sub 4}){sub 5}·2H{sub 2}O:0.05Eu{sup 2+} sample exhibited intense wide characteristic blue emission of Eu{sup 2+}, which could be decomposed by Gaussian fitting into two peaks corresponding to different Eu{sup 2+} luminous centers. The present results demonstrated that the morphology-tunable H{sub 3}Sr{sub 6}(PO{sub 4}){sub 5}·2H{sub 2}O:Eu{sup 2+} microarchitecture could be used as a potential candidate for future optoelectronic device applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Complexity of the CaF 2 :Yb System: A Huge, Reversible, X-ray-Induced Valence Reduction

Here lanthanides are multivalent chemical systems whose luminescence activates numerous optical devices. Their multivalent nature sets a complex scenario that challenges widespread single-valent-ion models. Here we study the complexity inherent in the 2+/3+ mixed-valence nature of Yb in CaF 2 . We report X-ray absorption spectroscopy of CaF 2 :Yb that shows a maximal, huge Yb 3+ X-ray-induced valence reduction at 200 K for low Yb concentration (0.01%) samples, which reverts to the initial state upon warming to 300 K. Although reduction doubles the number of Yb 2+ ions, the anomalous emission that is normally observed at low temperatures completely disappears and never recovers. Surprisingly, however, after annealing at 900 K, some anomalous emission is again observed below 150 K. Under X-ray exposure electrons are ejected from the F – ions, including charge compensating interstitials, F i – . Removing an electron from F i – leaves a neutral atom which appears metastable. Ab initio calculations of the F i – -to-Yb 3+ electron transfer reveal there is a critical dopant–compensator distance below which reoxidation is spontaneous and above which it is not. This, together with temperature-dependent F i 0 and F i – mobilities, and the interpretation of the anomalous emission as an Yb 2+ -to-Yb 3+ electron transfer provide a model for interpreting the complex experimental observations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Suppressing Phase Segregation and Improving Stability in Mixed-Halide Perovskites through Spinel Oxide-Directed Epitaxy

Mixed-cation mixed-halide perovskite compositions are essential for achieving the required bandgaps for high-efficiency multijunction photovoltaics, yet their stability remains limited by interfacial defects, phase segregation, and degradation. Here, we introduce spinel oxides as a new family of lattice-matched substrates that enable crystalline, phase-pure, compositionally-uniform, bromide-rich perovskite film growth. The effect of spinel oxides is two-fold: reducing defects at the bottom interface by templating film growth and inducing beneficial compressive strain through mismatch-dependent substrate-perovskite lattice coupling. Spinel oxide substrates facilitate growth of highly crystalline films and eliminate detrimental secondary phases across thicknesses. Using grazing incidence X-ray diffraction, X-ray fluorescence, cathodoluminescence–scanning electron microscopy, cryogenic photoluminescence, and density functional theory, we reveal that Mg-halide bonds at the bottom interface induce lattice mismatch-dependent compressive strain that suppresses halide segregation and further reduces defect formation. In addition, films grown on spinel oxides maintain over 87% of the perovskite phase after 12 h under 100% relative humidity, as monitored by in situ grazing incidence wide-angle X-ray scattering (GIWAXS), compared to less than 70% for control samples. This work extends lattice matching from vapor-deposited epitaxial semiconductors to solution-processed halide perovskites to establish a broadly applicable strategy for defect suppression, phase homogenization, and long-term stability. Based on the fundamental science explored here, we set the stage for the development of lattice-matched spinel oxide charge transport layers to be integrated into perovskite solar cells and other optoelectronic devices.

36 MATERIALS SCIENCE↗

Topological current divider in a Chern insulator junction

A Chern insulator is a two-dimensional material that hosts chiral edge states produced by the combination of topology with time reversal symmetry breaking. Such edge states are perfect one-dimensional conductors, which may exist not only on sample edges, but on any boundary between two materials with distinct topological invariants (or Chern numbers). Engineering of such interfaces is highly desirable due to emerging opportunities of using topological edge states for energy-efficient information transmission. Here, we report a chiral edge-current divider based on Chern insulator junctions formed within the layered topological magnet MnBi 2 Te 4 . We find that in a device containing a boundary between regions of different thickness, topological domains with different Chern numbers can coexist. At the domain boundary, a Chern insulator junction forms, where we identify a chiral edge mode along the junction interface. We use this to construct topological circuits in which the chiral edge current can be split, rerouted, or switched off by controlling the Chern numbers of the individual domains. Our results demonstrate MnBi 2 Te 4 as an emerging platform for topological circuits design.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The operation cutoff frequency of high electron mobility transistor measured by terahertz method

Commonly, the cutoff frequency of high electron mobility transistor (HEMT) can be measured by vector network analyzer (VNA), which can only measure the sample exactly in low frequency region. In this paper, we propose a method to evaluate the cutoff frequency of HEMT by terahertz (THz) technique. One example shows the cutoff frequency of our HEMT is measured at ∼95.30 GHz, which is reasonable agreement with that estimated by VNA. It is proved THz technology a potential candidate for the substitution of VNA for the measurement of high-speed devices even up to several THz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Focusing adaptive-optics for neutron spectroscopy at extreme conditions

Neutron Spectroscopy employing extreme-conditions sample environments is nowadays a crucial tool for the understanding of fundamental scientific questions as well as for the investigation of materials and chemical-physical properties. For all these kinds of studies, an increased neutron flux over a small sample area is needed. The prototype of a focusing neutron guide component, developed and produced completely at the neutron source FRM II in Garching (Germany), has been installed at the time-of-flight (TOF) disc-chopper neutron spectrometer TOFTOF and came into routine-operation. The design is based on the compressed Archimedes' mirror concept for finite-size divergent sources. It represents a unique device combining the supermirror technology with Adaptive Optics, suitable for broad-bandwidth thermal-cold TOF neutron spectroscopy (here optimized for 1.4–10 Å). It is able to squeeze the beam cross section down to a square centimeter, with a more than doubled signal-to-background ratio, increased efficiency at high scattering angles, and improved symmetry of the elastic resolution function. We present a comparison between the simulated and measured beam cross sections, as well as the performance of the instrument within real experiments. This work intends to show the unprecedented opportunities achievable at already existing instruments, along with useful guidelines for the design and construction of next-generation neutron spectrometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photocatalytic and photoelectrochemical performance of Ta{sub 3}N{sub 5} microcolumn films fabricated using facile reactive sputtering

This paper presents the photocatalytic and photoelectrochemical (PEC) properties of Ta{sub 3}N{sub 5} microcolumn films. The highlights include (1) overcoming the fundamental barrier of standard reactive sputtering for fabricating microcolumns; (2) preventing unnecessary complexity from complicating facile sputtering; (3) an alternative but effective approach for fabricating Ta{sub 3}N{sub 5} without using caustic NH{sub 3} gases; (4) investigating morphology tuning for favorable photocatalysis and PEC reactions; and (5) elucidating the relationships of the structures, morphologies, and properties of Ta{sub 3}N{sub 5} microcolumns. High-resolution transmission electron microscopy and selective-area electron diffraction verified the polycrystallinity of Ta{sub 3}N{sub 5} microcolumns, of which the elemental compositions and stoichiometry were measured using electron-probe energy dispersive spectroscopy, Auger electron spectroscopy, and X-ray photoelectron spectroscopy. The corresponding band gap was determined to be approximately 2.1 eV. The sample exhibited a superior photodegradation capability; the photodegradation rate constant k was determined to be approximately 1.4 times higher than that of P25 under UV irradiation. A photocatalytic and PEC cycling test indicated the photodegradation reusability and photostability of the Ta{sub 3}N{sub 5} microcolumns. The incident photon-to-current efficiency performance reached 6%, suggesting that these microcolumns hold potential for application in PEC devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High pressure, high flow rate batch mixing apparatus for high throughput experiments

An automated, high pressure, high flow rate batch mixing apparatus has been designed and constructed for rapid, stable, and repeatable mixing of multiple gases and vapors. The apparatus operates as an intermittent batch mixer with cycles of topping off fresh mixture to maintain pressure in an accumulator tank until consumed in an experimental apparatus. At high duty cycles, the apparatus can also function at steady state. This style of mixing is suitable for experiments such as high repetition rate shock tubes and other devices with intermittent flow demands. It is compact and portable, facilitating use in locations such as synchrotron light sources. The entire apparatus is heated to permit the mixing of vapors from species with low volatilities. The apparatus is fully automated and runs for extended periods with the only intervention being to refresh reagent supplies. Here, the accuracy and repeatability of the apparatus were verified by periodic gas sampling and analysis with gas chromatography. Multi-component mixtures spanning a wide range of complexity, dilution, and volatility of constituents have been prepared. The compositions of the majority of the mixture were found to be stable over several filling cycles, repeatable, and with the proper calibration of set-point conditions, accurate. Challenges were encountered preparing a mixture from multi-component liquids, and potential solutions are discussed.

47 OTHER INSTRUMENTATION↗

Quantitative Analysis of Ultralow-Density Materials Using Laboratory-Based Quasi-Monochromatic Radiography

The measurement of the density of materials, especially ultralow-density foams, is difficult in that the measurement must be precise and localizable. The density of the material is often governed by its cellular (i.e., porous) structure, and many techniques exist to create that structure. Often, the cellular structure can vary from one location within the material to another, and when at low densities (i.e., densities lower than ~500 mg/cm 3 ), it can vary due to shrinkage during syneresis, collapse under the weight of gravity, or gas/water vapor uptake. Quantifying this variation is important for a variety of applications, especially when used in plasma physics targets. Knowing the density and its variation across the sample is critical for experimental results to be accurately predicted by physics calculations and for modeling the results of the physics targets. The use of quasi-monochromatic radiography provides a means to image the two-dimensional (2-D) distribution of density variation within silica aerogel materials and to quantitatively measure that variation from sample to sample and lot to lot. For this work, two batches of silica aerogels with targeted densities of ~20 mg/cm 3 were created, one batch at Lawrence Livermore National Laboratory, and the other batch at Los Alamos National Laboratory. Outlined here is a quasi-monochromatic radiography system using various X-ray sources coupled to a doubly curved crystal optic and X-ray charge-coupled device camera to image and characterize these materials. It was found that measuring the density both gravimetrically and using quasi-monochromatic radiography were statistically identical, although the two batches were found to be slightly higher than their targeted density due to shrinkage. The radiography system also provided 2-D information as to the aerogel quality, i.e., presence of voids, chipped material, or inclusions.

36 MATERIALS SCIENCE↗

Effect of alloying elements, cold work, and hydrogen on the irradiation-induced growth behavior of zirconium alloy variants - 2016-0040

In-reactor dimensional changes in zirconium-based alloys result from a complex interplay of many factors, such as (1) alloy type and composition, including the addition of elements such as niobium, iron, and tin; (2) fabrication process, including cold work, texture, and residual stresses; (3) irradiation temperature; and (4) hydrogen levels. In many cases, the observed dimensional changes in light water reactor fuel-assembly components-especially at high exposures-cannot be fully explained based on current growth and creep models. Therefore, a systematic approach was taken in this multi-year (2005-2011) Nuclear Fuel Industry Research Program investigation. The objective was to measure stress-free irradiation-induced growth (IIG) of specially fabricated alloys through irradiation under controlled conditions in the BOR-60 fast-flux test reactor up to a high fluence of approximately 2X10{sup 26} m{sup -2} (E>1 MeV)-equivalent to maximum of approximately 37 dpa exposure-followed by postirradiation examinations (PIEs). Irradiation temperature was within a narrow temperature range (320±10 deg. C). The PIEs included dimensional-change and microhardness measurements, metallography and hydride etching, and scanning transmission electron microscopy (STEM) or transmission electron microscopy (TEM). All irradiation samples (typically flat rectangular coupons or curvilinear cutouts of cladding tubes sized 35 by 6.5 by 0.8 mm) were pre-filmed to avoid the uptake of impurity hydrogen from sodium-cooled BOR-60. A wide variety of samples representing standard LWR cladding alloys with and without pre-hydriding (approximately 116 to approximately 718 ppm) as well as special compositions with iron contents (100 to 4,000 ppm) were irradiated. The irradiation in BOR-60 was done in five different stages (eight micro-cycles) and lasted approximately 18 months with interim and final growth measurements made using a high precision-length measurement device. Results of the extensive investigation include: significant effects of Fe, Nb, and hydrogen additions; quantification of growth rates from low to very high fluences (dpas); measurement of volume changes; and correlation of growth with -component dislocation densities. (authors)

36 MATERIALS SCIENCE↗

Structural, Morphological, Electrical and Magnetic Properties of Yttrium-Substituted Co-Zn Ferrites Synthesized by Double Sintering Technique

A series of rare earth Y{sup 3+} ion substituted Co-Zn ferrites Co{sub 0.5}Zn{sub 0.5}Y{sub x}Fe{sub 2-x}O{sub 4} (x = 0.00 to 0.08 in step of 0.02) have been synthesized by conventional double sintering technique from the oxide powders of Co, Zn, Fe, and Y. The XRD, FESEM, EDS, DC resistivity, dielectric measurements, VSM, and Curie temperature (T{sub c}) analysis have been used to investigate structural, morphological, electrical, and magnetic properties. Single phase of cubic spinel structure has been confirmed up to x < 0.06, and a small amount of secondary phase YFeO{sub 3} has also been detected for x > 0.06. The lattice parameter initially decreases than increases with yttrium concentrations. The FESEM image shows that the grains and grain boundaries are distinct and uniformly distributed and the purity has also been endorsed from the EDS spectra. The average grain size decreases at x = 0.02 and then increases with Y substitution. The long range mobility of charge carriers and presence of localized charge carriers with retreat from the Debye-like behavior in the compositions have been explored using electric modulus and impedance. The magnetic strength diminishes owing to existence of magnetic dilution in the A-B interactions subsequent to the T{sub c} declines with the x contents. The value of saturation magnetization decreases with increasing Y{sup 3+} contents that indicates that the domain wall motion become tougher due to substitution of foreign ions Y{sup 3+} that possess larger ionic radius. Therefore, the Y{sup 3+} substituted Co{sub 0.5}Zn{sub 0.5}Y{sub x}Fe{sub 2-x}O{sub 4} (x = 0.00 to 0.08 in step of 0.02) ferrites with high resistivity and low losses has implications to be used in high frequency and power supply devices applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Small-angle neutron polarimetry apparatus (SANPA): Development at the NIST Center for Neutron Research

Spherical neutron polarimetry directly measures the rotation of the neutron polarization after scattering from materials with magnetic structure. It is an under utilized measurement technique that is capable of measuring all nine elements of the polarization tensor of a material. In this article, we describe our new cryogen-free small-angle neutron polarimetry apparatus and infrastructure at the NIST Center for Neutron Research. The resulting apparatus is capable of continuous operation and is designed for measurements at low temperatures (4–8 K) using niobium Meissner shielding and mu-metal shielding to produce a zero-field (≤1 μT) cooling sample environment.

47 OTHER INSTRUMENTATION↗