Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Repeatability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Numerical study of multiscale compaction-initiated detonation

A multiscale model of heterogeneous condensed-phase explosives is examined computationally to determine the course of transient events following the application of a piston-driven stimulus. The model is a modified version of that introduced by Gonthier (Combust Sci Technol 175(9):1679–1709, 2003. https://doi.org/10.1080/00102200302373) in which the explosive is treated as a porous, compacting medium at the macro-scale and a collection of closely packed spherical grains capable of undergoing reaction and diffusive heat transfer at the meso-scale. A separate continuum description is ascribed to each scale, and the two scales are coupled together in an energetically consistent manner. Following piston-induced compaction, localized energy deposition at the sites of intergranular contact creates hot spots where reaction begins preferentially. Reaction progress at the macro-scale is determined by the spatial average of that at the grain scale. A parametric study shows that combustion at the macro-scale produces an unsteady detonation with a cyclical character, in which the lead shock loses strength and is overtaken by a stronger secondary shock generated in the partially reacted material behind it. Finally, the secondary shock in turn becomes the new lead shock and the process repeats itself.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-Shot Decoding of Good Quantum LDPC Codes

Abstract Quantum Tanner codes constitute a family of quantum low-density parity-check codes with good parameters, i.e., constant encoding rate and relative distance. In this article, we prove that quantum Tanner codes also facilitate single-shot quantum error correction (QEC) of adversarial noise, where one measurement round (consisting of constant-weight parity checks) suffices to perform reliable QEC even in the presence of measurement errors. We establish this result for both the sequential and parallel decoding algorithms introduced by Leverrier and Zémor. Furthermore, we show that in order to suppress errors over multiple repeated rounds of QEC, it suffices to run the parallel decoding algorithm for constant time in each round. Combined with good code parameters, the resulting constant-time overhead of QEC and robustness to (possibly time-correlated) adversarial noise make quantum Tanner codes alluring from the perspective of quantum fault-tolerant protocols.

97 MATHEMATICS AND COMPUTING↗

Comparison of image noise and image quality between full-dose abdominal computed tomography scans reconstructed with weighted filtered back projection and half-dose scans reconstructed with improved sinogram-affirmed iterative reconstruction (SAFIRE*)

Purpose: To retrospectively compare the image noise, signal-to-noise ratio (SNR), and subjective image quality between CT images acquired with a dual-source, split-dose imaging protocol reconstructed at full and half doses with weighted filtered back projection (wFBP) and an improved sinogram-affirmed iterative reconstruction algorithm (SAFIRE*). Methods: Fifty-three consecutive patients underwent contrast-enhanced CT of the abdomen using a standardized dual-source, single energy CT protocol. Half-dose images were retrospectively generated using data from one detector only. Full-dose datasets were reconstructed with wFBP, while half-dose datasets were reconstructed with wFBP and SAFIRE* strengths 1–5. Region of interest analysis was performed to assess SNR and noise. Diagnostic acceptability, subjective noise, and spatial resolution were graded on a 10-point scale by two readers. Statistical analysis was carried out with repeated measures analysis of variance, Wilcoxon signed rank test, and Cohen’s κ test. Results: With the increasing strengths of SAFIRE*, a progressive reduction in noise and increase in SNR (p < 0.01) was observed. There was a statistically significant decrease in objective noise and increase in SNR in half-dose SAFIRE* strength 4 and 5 reconstructions compared to full-dose reconstructions using wFBP (p < 0.01). Qualitative analysis revealed a progressive increase in diagnostic acceptability, decrease in subjective noise and increase in spatial resolution for half-dose images reconstructed with the increasing strengths of SAFIRE* (p < 0.01). Conclusions: Half-dose CT images reconstructed with SAFIRE* at strength 4 and 5 have superior image quality compared to full-dose images reconstructed with wFBP. SAFIRE* potentially allows dose reductions in the order of 50% over wFBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precision and accuracy of magnetic resonance imaging for lobar classification of benign prostatic hyperplasia

Purpose: To validate the application of a magnetic resonance imaging (MRI)-based lobar classification of benign prostatic hyperplasia (BPH) for use in research and clinical management. Methods: Two radiologists with 5 and 11 years post-fellowship experience were trained in the lobar classification of BPH using an internally developed atlas of prostate anatomy with example MRI images edited by a third senior radiologist designated as the “administrator” of the study. A study population of 140 patients referred to a tertiary academic medical center with known or suspected prostate cancer was selected by the administrator to test the interrater reliability (IRR; precision) of the classification as well as accuracy of the two readers compared to the administrator as the “gold” standard. The intrarater reliability of repeat readings of the administrator was also examined. Percentage of agreement, proportion of agreement, and Cohen’s κ were applied. This was a retrospective IRB-approved study. Results: IRR (precision) between the two interpreting radiologists was 64% agreement, corresponding to unweighted κ of 0.52. Composite proportion of agreement across all BPH types (categories) for interpreting radiologists was 0.67. Observer accuracy was 62% agreement, unweighted κ 0.49, for observer 1 and 67%, unweighted κ 0.58, for observer 2. Intrarater reliability for the administrator was 87% agreement, unweighted κ 0.81 with composite proportion of agreement across all categories of 0.87. Conclusions: MRI lobar classification of BPH is a reproducible and reliable tool for research and clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of True Renal Arterial Aneurysms: Results from a Single Centre

PurposeTo report a single centre’s experience of the endovascular treatment of renal arterial aneurysms, including techniques and outcomes.Materials and MethodsThis is a retrospective analysis of true renal arterial aneurysms (TRAAs) treated using endovascular techniques over a period of 12 years and 10 months. The clinical presentations, aneurysm characteristics, endovascular techniques and outcomes are reported.ResultsThere were nine TRAA cases with a mean aneurysm size of 21.0 mm, located at the main renal arterial bifurcation in all cases. Onyx{sup ®} was used as the embolic agent of choice (88.9 % cases), with concurrent balloon remodelling. The overall primary technical success rate was 100 %. Repeat intervention was carried out in 1 case, secondary to reperfusion >8 years post-initial treatment. Long-term clinical follow-up was available in 55.6 % of cases (mean 29.8 months; range 3.3–90.1 months). Early post-procedural renal function, as measured by serum creatinine, remained within the normal reference range. Renal parenchymal loss post-embolisation was ≤20 % in 77.8 % of cases, as estimated on imaging. Minor complications included non-target embolization of Onyx{sup ®} with no clinical sequelae (n = 1), transient pain requiring only oral analgesia with no prolongation of hospital stay (n = 2). No major complications occurred as a consequence of embolisation.ConclusionEndovascular therapy is an effective and safe primary therapy for TRAA with high success rate and low morbidity, supplanting surgery as primary therapy. Current experience in the use of Onyx{sup ®} in TRAA is primarily limited to individual case reports, and this represents the largest case series of Onyx{sup ®}-treated TRAAs to date.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of C-Arm Cone Beam CT During Hepatic Radioembolization: Protocol Optimization for Extrahepatic Shunting and Parenchymal Enhancement

PurposeTo optimize a C-arm computed tomography (CT) protocol for radioembolization (RE), specifically for extrahepatic shunting and parenchymal enhancement.Materials and MethodsA prospective development study was performed per IDEAL recommendations. A literature-based protocol was applied in patients with unresectable and chemorefractory liver malignancies undergoing an angiography before radioembolization. Contrast and scan settings were adjusted stepwise and repeatedly reviewed in a consensus meeting. Afterwards, two independent raters analyzed all scans. A third rater evaluated the SPECT/CT scans as a reference standard for extrahepatic shunting and lack of target segment perfusion.ResultsFifty scans were obtained in 29 procedures. The first protocol, using a 6 s delay and 10 s scan, showed insufficient parenchymal enhancement. In the second protocol, the delay was determined by timing parenchymal enhancement on DSA power injection (median 8 s, range 4–10 s): enhancement improved, but breathing artifacts increased (from 0 to 27 %). Since the third protocol with a 5 s scan decremented subjective image quality, the second protocol was deemed optimal. Median CNR (range) was 1.7 (0.6–3.2), 2.2 (−1.4–4.0), and 2.1 (−0.3–3.0) for protocol 1, 2, and 3 (p = 0.80). Delineation of perfused segments was possible in 57, 73, and 44 % of scans (p = 0.13). In all C-arm CTs combined, the negative predictive value was 95 % for extrahepatic shunting and 83 % for lack of target segment perfusion.ConclusionAn optimized C-arm CT protocol was developed that can be used to detect extrahepatic shunts and non-perfusion of target segments during RE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI-Guided Percutaneous Biopsy of Mediastinal Masses Using a Large Bore Magnet: Technical Feasibility

ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinum (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Efficacy of Percutaneous Internal Plastic Stent Placement for Non-anastomotic Biliary Stenosis After Liver Transplantation

PurposeWe aimed to evaluate the long-term efficacy of percutaneous management of non-anastomotic biliary stenosis after liver transplantation, using plastic internal biliary stents.Materials and MethodsThis study included 35 cases (28 men, 7 women; mean age: 52.09 ± 8.13 years, range 34–68) in 33 patients who needed repeated interventional procedures because of biliary strictures. After classification of the biliary strictures, we inserted percutaneous biliary plastic stents through the T-tube or percutaneous transhepatic biliary drainage tracts. Stents were exchanged according to percutaneous methods at regular 2- to 6-month intervals. The stents were removed if the condition improved, as observed on cholangiogram as well as based on clinical findings. The median patient follow-up period after initial diagnosis and treatment was 6.04 years (range 0.29–9.95 years). We assessed treatment success rate and patient and graft survival times.ResultsDuring the follow-up period, 14 patients (14/33, 42.42 %) were successfully treated and were tube-free. The median tube-free time, time without a stent, was 4.13 years (range 1.00–9.01). In contrast, internal plastic stents remained in 9 patients (9/33, 27.27 %) until the last follow-up. These patients had acceptable hepatic function. Among the remaining 10 patients, 3 (3/33, 9.09 %) were lost to regular follow-up and the other 7 (7/33, 21.21 %) patients died. The overall graft loss rate was 20.0 % (7/35). The median time from initial treatment to graft loss was 1.84 years (range 0.42–4.25).ConclusionsPercutaneous plastic stents placement is technically feasible and clinically useful in patients with multiple biliary stenoses following liver transplantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Endovascular Treatment with Distal Radial Artery Coil Embolization and Angioplasty in Steal Syndrome Associated with Forearm Dialysis Fistula

PurposeThe present study was performed to define the results of the endovascular treatment with angioplasty and distal radial artery embolization in ischemic steal syndrome associated with forearm arteriovenous accesses.MethodThe cases referred to our interventional radiology unit with symptoms and physical examination findings suggestive of ischemic steal syndrome were retrospectively evaluated first by Doppler ultrasonography, and then by angiography. Cases with proximal artery stenosis were applied angioplasty, and those with steal syndrome underwent coil embolization to distal radial artery.ResultsOf 589 patients who underwent endovascular intervention for dialysis arteriovenous fistulae (AVF)-associated problems, 6 (1.01 %) (5 female, 1 males; mean age 62 (range 41–78) with forearm fistula underwent combined endovascular treatment for steal syndrome. In addition to steal phenomenon, there were stenosis and/or occlusion in proximal radial and/or ulnar artery in 6 patients concurrently. Embolization of distal radial artery and angioplasty to proximal arterial stenoses were performed in all patients. Ischemic symptoms were eliminated in all patients and the AVF were in use at the time of study. In one patient, ischemic symptoms recurring 6 months later were alleviated by repeat angioplasty of ulnar artery.ConclusionIn palmar arch steal syndrome affecting forearm fistulae, combined distal radial embolization and angioplasty is also an effective treatment method in the presence of proximal radial and ulnar arterial stenoses and occlusions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MWA Versus RFA for Perivascular and Peribiliary CRLM: A Retrospective Patient- and Lesion-Based Analysis of Two Historical Cohorts

PurposeTo retrospectively analyse the safety and efficacy of radiofrequency ablation (RFA) versus microwave ablation (MWA) in the treatment of unresectable colorectal liver metastases (CRLM) in proximity to large vessels and/or major bile ducts.Method and MaterialsA database search was performed to include patients with unresectable histologically proven and/or {sup 18}F–FDG–PET avid CRLM who were treated with RFA or MWA between January 2001 and September 2014 in a single centre. All lesions that were considered to have a peribiliary and/or perivascular location were included. Univariate logistic regression analysis was performed to assess the distribution of patient, tumour and procedure characteristics. Multivariate logistic regression was used to correct for potential confounders.ResultsTwo hundred and forty-three patients with 774 unresectable CRLM were ablated. One hundred and twenty-two patients (78 males; 44 females) had at least one perivascular or peribiliary lesion (n = 199). Primary efficacy rate of RFA was superior to MWA after 3 and 12 months of follow-up (P = 0.010 and P = 0.022); however, after multivariate analysis this difference was non-significant at 12 months (P = 0.078) and vanished after repeat ablations (P = 0.39). More CTCAE grade III complications occurred after MWA versus RFA (18.8 vs. 7.9 %; P = 0.094); biliary complications were especially common after peribiliary MWA (P = 0.002).ConclusionFor perivascular CRLM, RFA and MWA are both safe treatment options that appear equally effective. For peribiliary CRLM, MWA has a higher complication rate than RFA, with similar efficacy. Based on these results, it is advised to use RFA for lesions in the proximity of major bile ducts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lymphatic Leak Occurring After Surgical Lymph Node Dissection: A Preliminary Study Assessing the Feasibility and Outcome of Lymphatic Embolization

PurposeTo analyze imaging findings of lymphatic leakage associated with surgical lymph node dissection on lymphangiography and assess the outcome of lymphatic embolization.Materials and MethodsThis retrospective study comprised 21 consecutive patients who were referred for lymphatic intervention between March 2014 and April 2015 due to postsurgical lymphatic leaks. Lymphangiography was performed through inguinal lymph nodes to identify the leak. When a leak was found, lymphatic embolization was performed by fine-needle injection of N-butyl cyanoacrylate into the site of leakage or into an inflow lymphatic vessel or into a pelvic lymph node located below the leakage. Electronic medical records and imaging studies were reviewed to assess the outcome.ResultLymphangiography revealed single or multiple leaks in all but one patient. Lymphatic embolization was performed in 20 patients with leaks. Including the patient who did not undergo embolization, 17 patients (81.0 %) showed initial response to treatment. Three patients underwent repeated embolization with successful results. The overall success rate was 95.2 %. The mean duration of hospitalization after lymphatic intervention was 5.9 days. During a mean follow-up period of 11 months, two patients developed localized swelling in the groin following lipiodol injection. There were no complications related to lymphatic embolization. Three patients were found to have developed small, asymptomatic lymphoceles on CT or MRI that did not require further treatment.ConclusionLymphangiography is useful for detecting lymphatic leakage occurring after lymph node dissection. Furthermore, lymphatic embolization is feasible, effective, and safe for managing leaks demonstrated on lymphangiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Essentials of Parathyroid Hormone Venous Sampling

Hyperparathyroidism is an excess of parathyroid hormone in the blood due to over-activity of one or more parathyroid gland. Localization of abnormal glands with noninvasive imaging modalities, such as technetium sestamibi scan and cross-sectional imaging, has a high success rate. Parathyroid venous sampling is performed for patients with persistent or recurrent disease after previous parathyroid surgery, when repeat noninvasive imaging studies are negative or discordant. The success of invasive localization studies and results interpretation is dependent on the interventional radiologist’s understanding of the normal and ectopic anatomic locations of parathyroid glands, as well as their blood supply and venous drainage. Anatomic and technical considerations for selective parathyroid venous sampling are reviewed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Myocardial Infarction as a Complication of Bronchial Artery Embolization

Bronchial artery embolization is now a common treatment for massive pulmonary hemoptysis if flexible bronchoscopy at the bedside failed to control the bleeding. Complications of this technique range from benign chest pain to devastating neurological impairments. We report the case of a 41-year-old man who developed an ST elevation myocardial infarction during bronchial artery embolization, presumably because of coronary embolism by injected particles. In this patient who had no previously known coronary artery disease, we retrospectively found a communication between the left bronchial artery and the circumflex coronary artery. This fistula was not visible on the initial angiographic view and likely opened because of the hemodynamic changes resulting from the embolization. This case advocates for careful search for bronchial-to-coronary arterial fistulas and the need for repeated angiographic views during embolization procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Recurrent Spontaneous Hemarthrosis After Arthroplasty

PurposeRecurrent spontaneous hemarthrosis is an infrequent but debilitating late complication of joint replacement, affecting up to 1.6% of patients with arthroplasty of the affected joint. Repeated episodes of bleeding result in an inflammatory cascade that further propagates bleeding events. Open and arthroscopic synovectomy are often performed when conservative treatments fail. Transarterial embolization is increasingly utilized as a less invasive option; however, its role is not widely established. We performed a systematic literature review to report the safety and efficacy of transarterial embolization in treating recurrent hemarthrosis in the setting of prior arthroplasty.Materials and MethodsA systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Review and Meta-Analysis guidelines. A structured search was performed in PubMed, Web of Science, Embase, and SCOPUS databases of patients undergoing embolization for recurrent hemarthrosis after arthroplasty. Patients immediately post-operative, those embolized at first bleeding episode, and those with hemophilia were excluded. Demographic data, clinical information, angiographic findings, treatment, and outcomes were tabulated.ResultsThe search identified 119 titles of which 24 were deemed relevant, comprising 91 patients undergoing 99 embolization procedures. Mean time from prosthesis implantation was 32.2 months. Technical success was 99%. Mean follow-up time was 24.9 months. There were 10 recurrences (10%). Two cases were complicated by joint infection requiring arthroplasty revision.ConclusionsTransarterial embolization for recurrent spontaneous hemarthrosis may be safe and effective in patients having undergone arthroplasty of the affected joint.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cinnamic Acid Derivatives Enhance the Efficacy of Transarterial Embolization in a Rat Model of Hepatocellular Carcinoma

IntroductionWe hypothesize that the combination of transarterial embolization (TAE) plus inhibition of lactate export will limit anaerobic metabolism and reduce tumor survival compared to TAE alone. The purpose of this study was to test this hypothesis in a rat model of hepatocellular carcinoma (HCC).MethodsRat N1-S1 hepatoma cells were assayed in vitro using the Seahorse XF analyzer to measure extracellular acidification (lactate excretion) comparing effects of the addition of caffeic acid (CA) or ferulic acid (FA) or UK-5099 with control. Monocarboxylate transporter Slc16a3 was knocked down by RNAi. N1S1 tumors were orthotopically implanted in rats and 4 groups evaluated: (1) Control, (2) TAE-only, (3) TAE plus CA, and (4) TAE plus FA. Tumor size was determined by ultrasound and analyzed by repeated measures statistics. Tumors harvested at 4 weeks were examined by microscopy.ResultsSeahorse assays showed that CA and FA caused a significant reduction by >90% in lactate efflux by N1S1 tumor cells (p < 0.01). Knockdown of Slc16a3 prevented inhibition by CA. In vivo tumors grew 30-fold in volume over 4 weeks in untreated controls. By comparison, TAE resulted in near cessation of growth (10% in 4-week time period). However, both TAE + CA and TAE + FA caused a significant reduction of tumor volumes (87 and 72%, respectively) compared to control and TAE (p < 0.05). Pathologic evaluation revealed residual tumor in the TAE group but no residual viable tumor cells in the TAE + CA and TAE + FA groups.ConclusionAddition of CA or FA enhances the effectiveness of TAE therapy for HCC in part by blocking lactate efflux.

60 APPLIED LIFE SCIENCES↗

Hybrid Approach for Biliary Interventions Employing MRI-Guided Bile Duct Puncture with Near-Real-Time Imaging

ObjectiveTo assess the feasibility of a hybrid approach employing MRI-guided bile duct (BD) puncture for subsequent fluoroscopy-guided biliary interventions in patients with non-dilated (≤3 mm) or dilated BD (≥3 mm) but unfavorable conditions for ultrasonography (US)-guided BD puncture.MethodsA total of 23 hybrid interventions were performed in 21 patients. Visualization of BD and puncture needles (PN) in the interventional MR images was rated on a 5-point Likert scale by two radiologists. Technical success, planning time, BD puncture time and positioning adjustments of the PN as well as technical success of the biliary intervention and complication rate were recorded.ResultsVisualization even of third-order non-dilated BD and PN was rated excellent by both radiologists with good to excellent interrater agreement. MRI-guided BD puncture was successful in all cases. Planning and BD puncture times were 1:36 ± 2.13 (0:16–11:07) min. and 3:58 ± 2:35 (1:11–9:32) min. Positioning adjustments of the PN was necessary in two patients. Repeated capsular puncture was not necessary in any case. All biliary interventions were completed successfully without major complications.ConclusionA hybrid approach which employs MRI-guided BD puncture for subsequent fluoroscopy-guided biliary intervention is feasible in clinical routine and yields high technical success in patients with non-dilated BD and/or unfavorable conditions for US-guided puncture. Excellent visualization of BD and PN in near-real-time interventional MRI allows successful cannulation of the BD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bariatric Arterial Embolization with Non-spherical Polyvinyl Alcohol Particles for Ghrelin Suppression in a Swine Model

PurposeTo evaluate the effect of bariatric arterial embolization (BAE) with non-spherical polyvinyl alcohol (PVA) particles on systemic ghrelin levels, weight change, and gastric ulceration risk in a swine model.Materials and MethodsFrom March 2014 to February 2015, ten healthy swine were used in the study (mean weight 31.5 kg; range 24.0–41.5 kg). The animals were randomly assigned to two groups: the embolized group (n = 5) in which BAE was performed and the control group (n = 5). In the embolized group, BAE was performed by selectively infusing 150–250 or 50–150 μm PVA into the gastric arteries that supplied the fundus of the stomach. In the control group, a sham procedure was performed with saline infusion. Plasma ghrelin levels were prospectively obtained at baseline and every 2 weeks thereafter. Endoscopy was performed 3 weeks after BAE to see whether any gastric ulcer occurred. To determine the durability of the occluded arteries, repeated celiac trunk angiography was performed 8 weeks after BAE. Then, all the swine were killed and necropsies were performed.ResultsThe mean post-procedure ghrelin value decreased by 370.0 pg/mL in the embolized group at week 3 (mean 536.0 ± 334.3 pg/mL) and week 5 (mean 515.0 ± 150.0 pg/mL, p < 0.05) relative to baseline (880.0 ± 559.5 pg/mL), respectively, but ghrelin levels were not significantly decreased between the embolized and control groups. There was a significant body weight change as follows: 35.1 ± 9.5 to 46.6 ± 15.7 kg and 31.8 ± 5.8 to 41.2 ± 6.6 kg at baseline and endpoint in the control and embolized groups, respectively (p < 0.05). However, the difference between groups was not significant at endpoint. In the embolized group, ulcerations were identified in three animals (60%) and the recanalization of the embolized arteries was noted on follow-up angiography in three animals (60%), respectively.ConclusionBAE with PVA particles can transiently suppress ghrelin levels in embolized animals, but levels are not significantly different compared to controls. Stomach ulcerations were identified in 60% of the embolized animals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adenomatous-Dominant Benign Prostatic Hyperplasia (AdBPH) as a Predictor for Clinical Success Following Prostate Artery Embolization: An Age-Matched Case–Control Study

PurposeTo investigate the clinical impact of performing prostate artery embolization (PAE) on patients with adenomatous-dominant benign prostatic hyperplasia (AdBPH).Materials and MethodsTwelve patients from the ongoing proSTatic aRtery EmbolizAtion for the treatMent of benign prostatic hyperplasia (STREAM) trial were identified as having AdBPH; defined as two or more adenomas within the central gland of ≥1 cm diameter on multi-parametric MRI (MP-MRI). These patients were age-matched with patients from the STREAM cohort, without AdBPH. Patients were followed up with repeat MP-MRI at 3 months and 1 year. International prostate symptom score (IPSS), international index for erectile function (IIEF), and quality of life assessment from the IPSS and EQ-5D-5S questionnaires were recorded pre-PAE and at 6 weeks, 3 months, and 1 year.ResultsThe mean age of patients was 68 (61–76). All patients had PAE as a day-case procedure. The technical success in the cohort was 23/24 (96%). There was a significant reduction in prostate volume following embolization with a median reduction of 34% (30–55) in the AdBPH group, compared to a mean volume reduction of 22% (9–44) in the non-AdBPH group (p = 0.04). There was a significant reduction in IPSS in the AdBPH group following PAE when compared with the control group [AdBPH median IPSS 8 (3–15) vs. non-AdBPH median IPSS 13 (8–18), p = 0.01]. IPSS QOL scores significantly improved in the AdBPH group (p = 0.007). There was no deterioration in sexual function in either group post-PAE.ConclusionsThis is the first time that AdBPH has been identified as being a predictor of clinical success following PAE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗