Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reliability Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Electric Power Delivery Testing Feasibility Study (Task 6 Final Report)

This Final Report is covers the completion of the Electric Power Delivery Testing Feasibility Study. The objective of this project was to research, engineer, and demonstrate high-power laboratory testing protocols to accurately reproduce the conditions on the electric power grid representing both normal load switching and abnormalities such as short-circuit fault protection. Test circuits, equipment, and techniques were developed and proven at reduced power levels to determine the feasibility of building a large-scale high-power testing laboratory capable of testing equipment and systems at simulated high-power conditions of the U.S. power grid at distribution levels up through 38 kiloVolts (kV) and transmission levels up through 230 kV. The project delivered demonstrated testing techniques, high-voltage test equipment for load testing and synthetic short-circuit testing, and recommended designs for future implementation of a high-power testing laboratory to test equipment and systems, enabling increased reliability of the electric transmission and distribution grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Summary of May 21st and 22nd Shear Campaign [Slides]

We have streaked imaging of both smooth and roughened foils in both Ti and Al at both early and late times. Further work will be needed to check if the signal is strong enough on all shots to extract reliable mix-widths. The initial test of the 3 slit streaked imaging setup was unsuccessful. Streaked images of a driven shots using the slit on the target resulted in low signal, while un-driven shots showed much higher signals. The working hypothesis is that the signal dropped due to slit closure on the target; the successful NIF setup used a much wider slit, on the order of 100 um instead of 20 um. We were able to get good streak data by switching back to a 20 um pinhole at the front of the SSCA and removing the slits from the targets. To obtain the best late-time streak data we had to overlap the two TIM4 BL groups (on the BL driver). We have sets of plan view radiographs for at least three different times for both smooth and roughened foils in both Ti and Al. There are visually identifiable difference between the plan view radiographs of the smooth and enhanced roughened foils. The enhanced roughening is apparent in the plan view images at early times and seems to persist as the dominant structure scale into late times. We have several streaked plan view images. Further analysis will be required to determine if this can be turned into a viable platform for turbulence studies. Signal strength on the Al streaked plan view looks promising.

Plasma Physics & Fusion Technology(70)↗

A Scalable Process for Upcycling Carbon Dioxide (CO 2 ) and Coal Combustion Residues into Construction Products

Anthropogenic sources of carbon dioxide are generated from a number of sources, but the key among these are ordinary Portland cement (OPC) production and combustion of fossil fuels. Cement production is the largest global CO 2 source from the mineral decomposition of carbonates. Combination of the limestone decomposition and thermal requirements of the clinkering process causes cement production to contribute 8-9% of annual global CO 2 emissions. Combustion of fossil fuels (coal, oil and gas) was shown to contribute a much larger portion of global CO 2 emissions. As of 2018, combustion of fossil fuels accounted for 65% of global CO 2 , where 41% was derived from stationary sources for electricity and heat generation and the other 24% was related to transport. To reduce these contributions, key steps forward in CO 2 utilization technologies are required. The purpose of this project is to demonstrate the feasibility of the Reversa process evolving from a TRL-3 technology at the bench-scale up to TRL-6 technology at the pilot-scale. The reliability of the Reversa technology was tested to prove the effective production of concrete masonry units (CMUs) at bench scale, where the units exceeded the required 13.8 MPa compressive strength requirements. The overall goal of this project was to accelerate the development of a CO 2 mineralization process that synergistically utilizes CO 2 in flue gas and coal combustion residues (CCRs) to synthesize carbonated concrete, a functional replacement for traditional concrete. The culmination of this work resulted in 12 successful production runs at the Integrated Test Center (ITC), Gillette, WY using coal flue gas as a CO 2 source. This was followed by 6 production runs which were completed at the National Carbon Capture Center (NCCC), Wilsonville, AL, using coal-fired and natural gas (NG) flue gas as the CO 2 source. Over the course of the production runs at NCCC and ITC, the CO 2 utilization as a function of time, 24-h CO 2 uptake, electricity usage, and 28-d net area compressive strength recorded for each run. The ITC and NCCC demonstrations achieved an average of 0.19 and 0.1 g CO 2 /g reactant, respectively. Both demonstrations exceeded the project’s target goals of uptake > 0.05 g CO 2 /g reactant. Average compressive strength of the ITC blocks was 18.24 MPa at 28-days. This exceeded the target strength of 13.8 MPa specified by ASTM C90. ITC and NCCC produced an average CO 2 utilization efficiency of 74.9 and 57.9%, respectively. Both demonstration averages were within the target range of 50 to 90% utilization efficiency. For some production runs the NCCC demo did exceeded the a CO 2 utilization efficiency of 75%. An LCA of the Reversa process compared to an industry standard product revealed a net CO 2 reduction of 39% to 42%. This exceeded the target requirement of >25% net CO 2 reduction. Collection of this data was used to determine that the project was successful as the demonstration goals were achieved: (1) achieving in excess of 75% CO 2 utilization efficiency, (2) utilizing greater than 250 kg of CO 2 per production batch/run, and (3) ensuring compliance of carbonated blocks with industry standard specifications (ASTM C90).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving solar panel durability through novel panel designs and advanced manufacturing equipment

Work in the project was spread across 4 main themes:1) Improved Understanding of Why Cracks Form and Cause Degradation in Solar Cells: We developed a finite element model which correlated well with experimental determined deflection vs load profiles and which predicted stress profiles vs load level and temperature. These profiles helped to guide brace designs and showed the high stress levels seen in the silicon near the interconnect wire locations as the temperature is cooled below -30C, likely forming "invisible" microcracks. Experiments showed how for polymer backsheet modules, a brief exposure to such low temperatures made modules extremely sensitive to propagation of these microcracks at relatively low load levels, and how thicker and softer encapsulant helped to reduce this crack sensitivity. We showed for some modules that most cracks that are seen under loading had their origin at short, hard to see, V-cracks from soldering damage, and how the shunting from cells with high densities of cracks reduces energy delivery more than Pmax. 2) Improved Durability Testing Methods With Respect to Cracked Cells: We lobbied the PV community throughout the project that IEC 61215 was insufficient to probe the sensitivity of module Pmax degradation due to cracks in that in did not have a test leg that included a crack creation step (static loading) followed by a crack opening step (cyclic loading and/or thermal cycling). We published extensively on how pre- existing cracks opened up with cyclic loading. The new IEC TS 63209-1 ED1 test sequence now include our recommendations, and this should lead to improved module designs and reduced risk for investors. We also published recommendations for a new "Cold Climate Test" sequence to probe the sensitivity of modules to degradation from short microcracks formed when modules see temperatures below -30C followed by front side loading. We participated in several USTAG meetings related to cracked cells, EL testing, and mechanical load testing and provided input to the group to improve new standards under consideration. We also showed how the act of performing an EL test can affect the test results due to heating from the injected current. 3) New Module Designs and Related Manufacturing Methods & Equipment: We demonstrated reduced crack sensitivity on encapsulated cell coupons the benefits of building protective compressive stress into the cells by laminating them in a bent state and then allowing the coupon to flatten out after lamination. Our attempts to scale this to the module level with a more manufacturable sequence did not demonstrate the same positive effects, but we hope that others will follow up with other variations on this bent lamination or bent cooling concept to make more durable modules. 4) New Module Mounting Designs: We explored a range of bracing concepts which pressed on the backsheet to slightly bow the glass outward and place cells in a state of protective compressive stress and to reduce the deflection under front side loads. These successfully reduced cell cracking and crack opening, but high static loads permanently deformed cost-effective braces, after which they provided little benefit. We settled on an elegant & effective solution – the RailPad, where lightweight bracing elements are placed between the mounting rail(s) and the backsheet, and the existing strength of the rails is used to prevent module deflection under load. New construction and retrofit designs were made, and test sites were implemented in FL and MA. We applied for RailPad patent protection.

14 SOLAR ENERGY↗

Expanding Solar Research and Generation for a Bright Energy Future (Final Technical Report)

This project supported the construction of an outdoor solar research facility for the primary purpose of characterizing panel and system lifetimes in the northern New England climate which features cold winters and warm, humid summers. The facility is designed to be integrated into future efforts to explore the impacts of the New England climate on energy storage and grid integration, as well as methods to mitigate factors like snow and dust coverage in the industrial and agricultural environment of the Intervale farming community and the McNeil wood-fired power generating station. It will provide year-round renewable energy research opportunities for faculty and students. As renewable energy generation and storage have become research priorities for UVM, for the state of Vermont, and for the United States as a whole, this facility will benefit the public on a broad range of scales.

14 SOLAR ENERGY↗

Achieving Unprecedented CO 2 Utilization InCO 2 Concrete™: System Design, Product Development and Process Demonstration

Anthropogenic sources of carbon dioxide are generated from a number of sources, but the key among these are ordinary Portland cement (OPC) production and combustion of fossil fuels. Cement production is the largest global CO 2 source from the mineral decomposition of carbonates. This is due to the clinkering process whereby limestone (mainly consisting of CaCO 3 ) is decomposed into CaO and CO 2 , and combined with silica rich clays at high temperatures to form clinkers (i.e. the four key minerals that comprise cement). The high temperature range of 1400 – 1550°C required for this process accounts for up to 60% of the generated CO 2 from cement production. Combination of the limestone decomposition and thermal requirements of the clinkering process causes cement production to contribute 8-9% of annual global CO 2 emissions. Combustion of fossil fuels (coal, oil and gas) was shown to contribute a much larger portion of global CO 2 emissions. As of 2018, combustion of fossil fuels accounted for 65% of global CO 2 , where 41% was derived from stationary sources for electricity and heat generation and the other 24% was related to transport. To reduce these contributions, key steps forward in CO 2 utilization technologies are required. Therefore, a CO 2 mineralization technology (CO 2 mineralization concrete) to reduce the OPC content in concrete, while utilizing flue gas emissions from fossil fuel combustion has been developed to address both areas simultaneously. This Reversa™ technology utilizes low-carbon cementation agents produced by in situ CO 2 mineralization (“mineral carbonation reactions”) to offer a promising alternative to OPC. CO 2 mineralization relies upon the reaction of dissolved CO 2 with inorganic alkaline reactants to precipitate mineral carbonates (e.g., CaCO 3 ), which bind proximate particles and achieve cementation. Herein, a concrete green body, which is composed of a mixture of binder, water, and mineral aggregates, is exposed to CO 2 borne in industrial flue gas streams. This manner of CO 2 mineralization allows the production of construction components that feature equivalent engineering attributes as their OPC-based counterparts while featuring a much smaller embodied carbon intensity (eCI). The purpose of this project is to demonstrate the feasibility of the Reversa process evolving from a TRL-3 technology at the bench-scale up to TRL-6 technology at the pilot-scale. The reliability of the Reversa technology was tested to prove the effective production of three standard industrial concrete products selected during the course of the project. The results detailed herein will demonstrate the evolution of this technology to the industrial scale. The culmination of this work resulted in 9 production runs completed at the National Carbon Capture Center (NCCC), Wilsonville, AL, using natural gas (NG) flue gas as the CO 2 source. Over the course of the production runs at NCCC, the CO 2 utilization as a function of time, 24-h CO 2 uptake, electricity usage, and 28-d net area compressive strength recorded for each run. Collection of this data will be used to determine the success of the demonstration goals: (1) achieving in excess of 0.2gCO 2 /g reactant , (2) achieving greater than 50% reduction in global warming potential compared to standard produced units, and (3) ensuring compliance of carbonated concrete with industry standard specifications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of potential buffet problems on the space shuttle vehicle

Buffet of the space shuttle launch and reentry configuration is an area requiring continued evaluation to produce a safe reliable vehicle of minimum weight. Buffet forces result from flow separation and therefore can not be predicted accurately. Buffet loads are highly sensitive to configuration, angle of attack, and Mach number and can be reliably determined only by wind tunnel tests of elastically scaled models.

Muhlstein, L., Jr.↗

Long life assurance study for manned spacecraft long life hardware. Volume 1: Summary of long life assurance guidelines

A long life assurance program for the development of design, process, test, and application guidelines for achieving reliable spacecraft hardware was conducted. The study approach consisted of a review of technical data performed concurrently with a survey of the aerospace industry. The data reviewed included design and operating characteristics, failure histories and solutions, and similar documents. The topics covered by the guidelines are reported. It is concluded that long life hardware is achieved through meticulous attention to many details and no simple set of rules can suffice.

Source record↗

Utilization survey of prototype structural test article

A survey was conducted of six aerospace companies and two NASA agencies to determine how prototype structural test articles are used in flight operations. The prototype structures are airframes and similar devices which are used for testing and generally are not flown. The survey indicated the following: (1) prototype test articles are not being discarded after development testing is complete, but are used for other purposes, (2) only two cases of prototypes being refurbished and flown were identified, (3) protective devices and inspection techniques are available to prevent or minimize test article damage, (4) substitute programs from design verification are availabel in lieu of using prototype structural articles, and (5) there is a trend away from dedicated test articles. Four options based on these study results were identified to reduce test and hardware costs without compromising reliability of the flight program.

Baber, S.↗

Annular Momentum Control Device (AMCD). Volume 1: Laboratory model development

The annular momentum control device (AMCD) a thin hoop-like wheel with neither shaft nor spokes is described. The wheel floats in a magnetic field and can be rotated by a segmented motor. Potential advantages of such a wheel are low weight, configuration flexibility, a wheel that stiffens with increased speed, vibration isolation, and increased reliability. The analysis, design, fabrication, and testing is described of the laboratory model of the AMCD.

Source record↗

ATS-6 - Spacecraft Attitude Precision Pointing and Slewing Adaptive Control Experiment

The primary objective of the Spacecraft Attitude Precision Pointing and Slewing Adaptive Control (SAPPSAC) experiment is to establish feasibility and evaluate capabilities of a ground-based spacecraft attitude control system, wherein RF command and telemetry links, together with a ground station on-line minicomputer, perform closed loop attitude control of the Applications Technology Satellite-6 (ATS-6). The ground processor is described, including operational characteristics and the controller software. Attitude maneuvers include precision pointing to fixed targets, slewing between targets, and generation of prescribed ground tracks. Test results show high performance and reliability for over 30 hours of on-line control with no serious anomalies. Attitude stabilization relative to a prescribed target has been achieved to better than 0.007 deg in pitch and roll and 0.02 deg in yaw for a period of 43 min. Ground tracks were generated which had maximum latitude/longitude deviations less than 0.15 deg from reference.

Isley, W. C.↗

Extended performance solar electric propulsion thrust system study. Volume 4: Thruster technology evaluation

Several thrust system design concepts were evaluated and compared using the specifications of the most advanced 30 cm engineering model thruster as the technology base. Emphasis was placed on relatively high power missions (60 to 100 kW) such as a Halley's comet rendezvous. The extensions in thruster performance required for the Halley's comet mission were defined and alternative thrust system concepts were designed in sufficient detail for comparing mass, efficiency, reliability, structure, and thermal characteristics. Confirmation testing and analysis of thruster and power processing components were performed, and the feasibility of satisfying extended performance requirements was verified. A baseline design was selected from the alternatives considered, and the design analysis and documentation were refined. The baseline thrust system design features modular construction, conventional power processing, and a concentrator solar array concept and is designed to interface with the Space Shuttle.

Poeschel, R. L.↗

Test and evaluation of 23 electric vehicles for state-of-the-art assessment

Eleven of the electric vehicles were passenger cars and 12 were commercial vans. Tests were conducted in accordance with an ERDS test procedure which is based on the SAE J227a Test Procedure. Tests included range, acceleration, coast-down, and braking. The results of the tests are presented, and comments on reliability are made.

Dustin, M. O.↗