Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Phytosulfokine downregulates defense‐related WRKY transcription factors and attenuates pathogen‐associated molecular pattern‐triggered immunity

SUMMARY Phytosulfokine (PSK) is a plant growth‐promoting peptide hormone that is perceived by its cell surface receptors PSKR1 and PSKR2 in Arabidopsis. Plants lacking the PSK receptors show phenotypes consistent with PSK signaling repressing some plant defenses. To gain further insight into the PSK signaling mechanism, comprehensive transcriptional profiling of Arabidopsis treated with PSK was performed, and the effects of PSK treatment on plant defense readouts were monitored. Our study indicates that PSK's major effect is to downregulate defense‐related genes; it has a more modest effect on the induction of growth‐related genes. WRKY transcription factors (TFs) emerged as key regulators of PSK‐responsive genes, sharing commonality with a pathogen‐associated molecular pattern (PAMP) responses, flagellin 22 (flg22), but exhibiting opposite regulatory directions. These PSK‐induced transcriptional changes were accompanied by biochemical and physiological changes that reduced PAMP responses, notably mitogen‐activated protein kinase (MPK) phosphorylation (previously implicated in WRKY activation) and the cell wall modification of callose deposition. Comparison with previous studies using other growth stimuli (the sulfated plant peptide containing sulfated tyrosine [PSY] and Pseudomonas simiae strain WCS417) also reveals WRKY TFs' overrepresentations in these pathways, suggesting a possible shared mechanism involving WRKY TFs for plant growth–defense trade‐off.

Liu, Dian [Biochemistry and Molecular Biophysics T↗

Lynx x-ray microcalorimeter

Lynx is an x-ray telescope, one of four large satellite mission concepts currently being studied by NASA to be a flagship mission. One of Lynx’s three instruments is an imaging spectrometer called the Lynx x-ray microcalorimeter (LXM), an x-ray microcalorimeter behind an x-ray optic with an angular resolution of 0.5 arc sec and ~2 m 2 of area at 1 keV. The LXM will provide unparalleled diagnostics of distant extended structures and, in particular, will allow the detailed study of the role of cosmic feedback in the evolution of the Universe. We discuss the baseline design of LXM and some parallel approaches for some of the key technologies. The baseline sensor technology uses transition-edge sensors, but we also consider an alternative approach using metallic magnetic calorimeters. We discuss the requirements for the instrument, the pixel layout, and the baseline readout design, which uses microwave superconducting quantum interference devices and high-electron mobility transistor amplifiers and the cryogenic cooling requirements and strategy for meeting these requirements. For each of these technologies, we discuss the current technology readiness level and our strategy for advancing them to be ready for flight. We also describe the current system design, including the block diagram, and our estimate for the mass, power, and data rate of the instrument.

47 OTHER INSTRUMENTATION↗

Development of the microcalorimeter and anticoincidence detector for the Line Emission Mapper x-ray probe

The Line Emission Mapper (LEM) is an x-ray probe mission concept that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight x-ray optic with a large-format microcalorimeter array. The LEM detector utilizes a 14k pixel array of transition-edge sensors (TESs) that will provide <2.5 eV spectral resolution over the energy range 0.2 to 2 keV, along with a field-of-view of 30 arcmin. The microcalorimeter array and readout builds upon the technology developed for the European Space Agency’s (ESA’s) Athena/x-ray Integral Field Unit. Here, we present a detailed overview of the base- line microcalorimeter design, its performance characteristics, including a detailed energy resolution budget and the expected count-rate capability. In addition, we outline the current status and plan for continued technology maturation. Behind the LEM array sits a high-efficiency TES-based anticoincidence (antico) detector that will reject cosmic-ray background events. We will briefly describe the design of the antico and plan for continued development.

47 OTHER INSTRUMENTATION↗

High Pressure Sensing and Dynamics Using High Speed Fiber Bragg Grating Interrogation Systems

Fiber Bragg gratings (FBGs) are developing into useful sensing tools for measuring high pressure dynamics in extreme environments under shock loading conditions. Approaches using traditional diode array coupled FBG interrogation systems are often limited to readout speeds in the sub-MHz range. For shock wave physics, required detection speeds approaching 100 MHz are desired. We explore the use of two types of FBG sensing systems that are aimed at applying this technology as embedded high pressure probes for transient shock events. Both approaches measure time resolved spectral shifts in the return light from short (few mm long) uniform FBGs at 1550 nm. In the first approach, we use a fiber coupled spectrometer to demultiplex spectral channels into an array (up to 12) of single element InGaAs photoreceivers. By monitoring the detectors during a shock impact event with high speed recording, we are able to track the pressure induced spectral shifting in FBG down to a time resolution of 20 ns. In the second approach, developed at the Special Technologies Lab, a coherent mode-locked fiber laser is used to illuminate the FBG sensor. After the sensor, wavelength-to-time mapping is accomplished with a chromatic dispersive element, and entire spectra are sampled using a single detector at the modelocked laser repetition rate of 50 MHz. By sampling with a 12 GHz InGaAs detector, direct wavelength mapping in time is recorded, and the pressure induced FBG spectral shift is sampled at 50 MHz. Here, the sensing systems are used to monitor the spectral shifts of FBGs that are immersed into liquid water and shock compressed using explosives. In this configuration, the gratings survive to pressures approaching 50 kbar. We describe both approaches and present the measured spectral shifts from the shock experiments.

fiber Bragg grating sensors, shockwave diagnostics↗

Subwavelength films for standoff radiation dosimetry

We present optical subwavelength nanostructure architecture suitable for standoff radiation dosimetry with remote optical readout in the visible or infrared spectral regions. To achieve this, films of subwavelength structures are fabricated over several square inches via the creation of a 2D non-close packed (NCP) array template of radiation-sensitive polymeric nanoparticles, followed by magnetron sputtering of a metallic coating to form a 2D array of separated hemispherical nanoscale metallic shells. The nanoshells are highly reflective at resonance in the visible or infrared depending on design. These structures and their behavior are based on the open ring resonator (ORR) architecture and have their analog in resonant inductive-capacitive (LC) circuits, which display a resonance wavelength that is inversely proportional to the square root of the product of the inductance and capacitance. Therefore, any modification of the nanostructure material properties due to radiation alters the inductive or capacitive behavior of the subwavelength features, which in turn changes their optical properties resulting in a shift in the optical resonance. This shift in resonance may be remotely interrogated actively using either laser illumination or passively by hyperspectral or multispectral sensing with broadband illumination. These structures may be designed to be either anisotropic or isotropic, which can also offer polarization-sensitive interrogation. We present experimental measurements of a radiation induced shift in the optical resonance of a subwavelength film after exposure to an absorbed dose of gamma radiation from 2 Mrad up to 62 Mrad demonstrating the effect. Interestingly the resonance shift is non-monotonic for this material system and possible radiation damage mechanisms to the nanoparticles are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optically resonant subwavelength films for tamper-indicating tags and seals

We present the design, modeling and performance of a proof-of-concept tamper indicating approach that exploits newly-developed subwavelength-patterned films. These films have a nanostructure-dependent resonant optical reflection that is wavelength, angle, and polarization dependent. As such, they can be tailored to fabricate overlay transparent films for tamper indication and authentication of sensitive or controlled materials not possible with currently-known technologies. An additional advantage is that the unique optical signature is dictated by the geometry and fabrication process of the nanostructures in the film, rather than on the material used. The essential structure unit in the subwavelength resonant coating is a nanoscale Open-Ring Resonator (ORR). This building block is fabricated by coating a dielectric nanoscale template with metal to form a hemispherical shell-like structure. This curved metallic shell structure has a cross-section with an intrinsic capacitance and inductance and is thus the optical equivalent to the well-known “LC” circuit where the capacitance and inductance are determined by the nanoshell dimensions. For structures with sub 100 nm scale, this resonance occurs in the visible electromagnetic spectrum, and in the IR for larger shells. Tampering of the film would be visible though misalignment of the angular dependence of the features in the film. It is additionally possible to add in intrinsic oxidation and strain sensitive matrix materials to further complicate tamper repair and counterfeiting. Cursory standoff readout would be relatively simple using a combination of a near-infrared (or visible) LED flashlight and polarizer or passively using room lighting illumination and a dispersive detector.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Modeling and Analysis of Hybrid Pixel Detector Deficiencies for Scientific Applications

Semiconductor hybrid pixel detectors often consist of a pixellated sensor layer bump bonded to a matching pixelated readout integrated circuit (ROIC). The sensor can range from high resistivity Si to III-V materials, whereas a Si CMOS process is typically used to manufacture the ROIC. Independent, device physics and electronic design automation (EDA) tools are used to determine sensor characteristics and verify functional performance of ROICs respectively with significantly different solvers. Some physics solvers provide the capability of transferring data to the EDA tool. However, single pixel transient simulations are either not feasible due to convergence difficulties or are prohibitively long. A simplified sensor model, which includes a current pulse in parallel with detector equivalent capacitor, is often used; even then, spice type top-level (entire array) simulations range from days to weeks. In order to analyze detector deficiencies for a particular scientific application, accurately defined transient behavioral models of all the functional blocks are required. Furthermore, various simulations, such as transient, noise, Monte Carlo, inter-pixel effects, etc. of the entire array need to be performed within a reasonable time frame without trading off accuracy. The sensor and the analog front-end can be modeling using a real number modeling language, as complex mathematical functions or detailed data can be saved to text files, for further top-level digital simulations. Parasitically aware digital timing is extracted in a standard delay format (sdf) from the pixel digital back-end layout as well as the periphery of the ROIC. For any given input, detector level worst-case and best-case simulations are performed using a Verilog simulation environment to determine the output. Each top-level transient simulation takes no more than 10-15 minutes. The impact of changing key parameters such as sensor Poissonian shot noise, analog front-end bandwidth, jitter due to clock distribution etc. can be accurately analyzed to determine ROIC architectural viability and bottlenecks. Hence the impact of the detector parameters on the scientific application can be studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical design of PICO: a concept for a space mission to probe inflation and cosmic origins

The Probe of Inflation and Cosmic Origins (PICO) is a probe-class mission concept currently under study by NASA. PICO will probe the physics of the Big Bang and the energy scale of inflation, constrain the sum of neutrino masses, measure the growth of structures in the universe, and constrain its reionization history by making full sky maps of the cosmic microwave background with sensitivity 80 times higher than the Planck space mission. With bands at 21-799 GHz and arcmin resolution at the highest frequencies, PICO will make polarization maps of Galactic synchrotron and dust emission to observe the role of magnetic fields in Milky Way's evolution and star formation. We discuss PICO's optical system, focal plane, and give current best case noise estimates. The optical design is a two-reflector optimized open-Dragone design with a cold aperture stop. It gives a diffraction limited field of view (DLFOV) with throughput of 910 cm 2 sr at 21 GHz. The large 82 square degree DLFOV hosts 12,996 transition edge sensor bolometers distributed in 21 frequency bands and maintained at 0.1 K. We use focal plane technologies that are currently implemented on operating CMB instruments including three-color multi-chroic pixels and multiplexed readouts. To our knowledge, this is the first use of an open-Dragone design for mm-wave astrophysical observations, and the only monolithic CMB instrument to have such a broad frequency coverage. Finally, with current best case estimate polarization depth of 0.65 μKCMB-arcmin over the entire sky, PICO is the most sensitive CMB instrument designed to date.

79 ASTRONOMY AND ASTROPHYSICS↗

PICO - the probe of inflation and cosmic origins

Downloading of the abstract is permitted for personal use only. The Probe of Inflation and Cosmic Origins (PICO) is a NASA-funded study of a Probe-class mission concept. The toplevel science objectives are to probe the physics of the Big Bang by measuring or constraining the energy scale of inflation, probe fundamental physics by measuring the number of light particles in the Universe and the sum of neutrino masses, to measure the reionization history of the Universe, and to understand the mechanisms driving the cosmic star formation history, and the physics of the galactic magnetic field. PICO would have multiple frequency bands between 21 and 799 GHz, and would survey the entire sky, producing maps of the polarization of the cosmic microwave background radiation, of galactic dust, of synchrotron radiation, and of various populations of point sources. Several instrument configurations, optical systems, cooling architectures, and detector and readout technologies have been and continue to be considered in the development of the mission concept. We will present a snapshot of the baseline mission concept currently under development.

47 OTHER INSTRUMENTATION↗

Year 2 instrument status from the SPT-3G cosmic microwave background receiver (Conference Presentation)

The South Pole Telescope (SPT) is a millimeter-wavelength telescope surveying the cosmic microwave background (CMB). The SPT measures both the temperature and polarization of the CMB with a large aperture, resulting in high-resolution maps sensitive to signals across a wide range of angular scales on the sky. With these capabilities, the SPT has the potential to constrain inflationary gravitational waves as well as the effect of massive neutrinos on large-scale structure formation. The SPT was upgraded in late 2016 with a new receiver (SPT-3G) containing 16,0000 polarization-sensitive transition-edge sensor bolometers. Several key technological developments have enabled this large-format focal, including advances in detectors, readout electronics, and large millimeter-wavelength optics. We will discuss the implementation of these technologies in the SPT-3G receiver as well as the challenges they presented. In late 2017 the implementations of all three of these technologies were iterated to optimize total performance. Here, we present the current instrument status of the SPT-3G receiver.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and performance of the second-year SPT-3G focal plane

The third-generation instrument for the 10-meter South Pole Telescope, SPT-3G, was first installed in January 2017. In addition to completely new cryostats, secondary telescope optics, and readout electronics, the number of detectors in the focal plane has increased by an order of magnitude from previous instruments to ~16,000. The SPT-3G focal plane consists of ten detector modules, each with an array of 269 trichroic, polarization-sensitive pixels on a six-inch silicon wafer. Within each pixel is a broadband, dual-polarization sinuous antenna; the signal from each orthogonal linear polarization is divided into three frequency bands centered at 95, 150, and 220 GHz by in-line lumped element filters and transmitted via superconducting microstrip to Ti/Au transition-edge sensor (TES) bolometers. Properties of the TES film, microstrip filters, and bolometer island must be tightly controlled to achieve optimal performance. For the second year of SPT-3G operation, we have replaced all ten wafers in the focal plane with new detector arrays tuned to increase mapping speed and improve overall performance. Here we discuss the TES superconducting transition temperature and normal resistance, detector saturation power, bandpasses, optical efficiency, and full array yield for the 2018 focal plane.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BlackCAT CubeSat: a soft x-ray sky monitor, transient finder, and burst detector for high-energy and multimessenger astophysics

Here we present the conceptual design of a wide field imager onboard a 6U class CubeSat platform for the study of GRB prompt and afterglow emission and detection of electromagnetic counterparts of gravitational waves in soft X-rays. The planned instrument configuration consists of an array of X-ray Hybrid CMOS detectors (HCD), chosen for their soft-X-ray response, flexible and rapid readout rate, and low power, which makes these detectors well suited for detecting bright transients on a CubeSat platform. The wide field imager is realized by a 2D coded mask. This paper will give an overview of the instrument design and the scientific requirements of the proposed mission.

79 ASTRONOMY AND ASTROPHYSICS↗

CCAT-prime: Designs and status of the first light 280 GHz MKID array and mod-cam receiver

The CCAT-prime project's first light array will be deployed in Mod-Cam, a single-module testbed and first light cryostat, on the Fred Young Submillimeter Telescope (FYST) in Chile's high Atacama desert in late 2022. FYST is a six-meter aperture telescope being built on Cerro Chajnantor at an elevation of 5600 meters to observe at millimeter and submillimeter wavelengths. 1 Mod-Cam will pave the way for Prime-Cam, the primary first generation instrument, which will house up to seven instrument modules to simultaneously observe the sky and study a diverse set of science goals from monitoring protostars to probing distant galaxy clusters and characterizing the cosmic microwave background (CMB). At least one feedhorn-coupled array of microwave kinetic inductance detectors (MKIDs) centered on 280 GHz will be included in Mod-Cam at first light, with additional instrument modules to be deployed along with Prime-Cam in stages. The first 280 GHz detector array was fabricated by the Quantum Sensors Group at NIST in Boulder, CO and includes 3,456 polarization- sensitive MKIDs. Current mechanical designs allow for up to three hexagonal arrays to be placed in each single instrument module. We present details on this first light detector array, including mechanical designs and cold readout plans, as well as introducing Mod-Cam as both a testbed and predecessor to Prime-Cam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Single-Volume Scatter Camera

The multi-institution Single-Volume Scatter Camera (SVSC) collaboration led by Sandia National Laboratories (SNL) is developing a compact, high-efficiency double-scatter neutron imaging system. Kinematic emission imaging of fission-energy neutrons can be used to detect, locate, and spatially characterize special nuclear material. Neutron-scatter cameras, analogous to Compton imagers for gamma ray detection, have a wide field of view, good event-by-event angular resolution, and spectral sensitivity. Existing systems, however, suffer from large size and/or poor efficiency. We are developing high-efficiency scatter cameras with small form factors by detecting both neutron scatters in a compact active volume. This effort requires development and characterization of individual system components, namely fast organic scintillators, photodetectors, electronics, and reconstruction algorithms. In this presentation, we will focus on characterization measurements of several SVSC candidate scintillators. The SVSC collaboration is investigating two system concepts: the monolithic design in which isotropically emitted photons are detected on the sides of the volume, and the optically segmented design in which scintillation light is channeled along scintillator bars to segmented photodetector readout. For each of these approaches, we will describe the construction and performance of prototype systems. We will conclude by summarizing lessons learned, comparing and contrasting the two system designs, and outlining plans for the next iteration of prototype design and construction.

Manfredi, Juan↗

Results from the Advanced Scintillator Compton Telescope (ASCOT) Balloon Payload

The Advanced Scintillator Compton Telescope (ASCOT) is a medium-energy gamma-ray Compton telescope flown on NASA’s high-altitude scientific balloon from Palestine, TX on 5th July 2018. It uses commercially available highperformance scintillators like Cerium Bromide (CeBr3) and p-terphenyl along with compact readout devices - silicon photomultipliers (SiPMs) - for an improved instrument response. ASCOT was built to address the existing need for observations in the gamma-ray energy range of 0.4 - 20 MeV. Operating stably throughout the mission, it reached an altitude of 120,000 ft and observed the Crab Nebula at MeV energies for ~5 hours. Built on the legacy of COMPTEL (onboard CGRO), along with the hardware advancement ASCOT also makes use of the Time-of-Flight (ToF) background rejection technique for effective imaging. Presented here is the Energy and ToF calibrated flight data with optimal data cuts (Earth Horizon Cut, Pulse Shape Discrimination Cut). The growth curves generated using this data from 5 to 100 g/cm2 of residual atmosphere in conjunction with the Monte Carlo simulations of the instrument response have been used to obtain the Cosmic Diffuse Gamma-ray (CDG) flux value of (1.28 ± 0.37)×10 -5 photons/cm 2 /s/sr/keV for 0.4 – 0.7 MeV energy range. The 3σ upper limit for CDG flux is 1.8×10-5 photons/cm 2 /s/sr/keV for 0.7-1.5 MeV and 2×10-6 photons/cm2/s/sr/keV for 1.5-2.5 MeV. The analysis of the Crab Nebula from flight observation is underway

79 ASTRONOMY AND ASTROPHYSICS↗

SPT-3G+: mapping the high-frequency cosmic microwave background using kinetic inductance detectors

We present the design and science goals of SPT-3G+, a new camera for the South Pole Telescope, which will consist of a dense array of 34100 kinetic inductance detectors measuring the cosmic microwave background (CMB) at 220, 285 and 345 GHz. The SPT-3G+ dataset will enable new constraints on the process of reionization, including measurements of the patchy kinematic Sunyaev-Zeldovich effect and improved constraints on the optical depth due to reionization. At the same time, it will serve as a pathfinder for the detection of Rayleigh scattering, which could allow future CMB surveys to constrain cosmological parameters better than from the primary CMB alone. In addition, the combined, multi-band SPT-3G and SPT-3G+ survey data, will have several synergies that enhance the original SPT-3G survey, including: extending the redshift-reach of SZ cluster surveys to z > 2; understanding the relationship between magnetic fields and star formation in our Galaxy; improved characterization of the impact of dust on inflationary B-mode searches; and characterizing astrophysical transients at the boundary between mm and sub-mm wavelengths. Finally, the modular design of the SPT-3G+ camera allows it to serve as an on-sky demonstrator for new detector technologies employing microwave readout, such as the on-chip spectrometers that we expect to deploy during the SPT-3G+ survey. In this paper, we describe the science goals of the project and the key technology developments that enable its powerful yet compact design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of Microwave Transducers for Linearity Dependence and Applications in Quantum Networking

Quantum devices have the potential to revolutionize applications in computing, communications, and sensing; however, current state-of-art resources must operate at extremely low temperatures, making the routing of microwave control and readout signals challenging to scale. Interest in microwave photonic solutions to this problem has grown in recent years, in which control signals are delivered to the cold stage via optical fiber, where they are converted to electrical signals through photodetection. Overall link performance depends strongly on the characteristics of the photodiode, yet detailed measurements of many detector properties remain lacking at cold temperatures. In this work, we examine and compare the performance of a modified uni-traveling carrier photodiode (MUTC-PD) at both room (300 K) and liquid nitrogen (80 K) temperatures, focusing in particular on responsivity, bandwidth, and linearity. In line with previous work, we find a sharp reduction in responsivity at 1550 nm as temperature decreases, while RF bandwidth remains steady. Interestingly, our linearity tests reveal that the RF output saturates more quickly at 80 K, suggesting reduced linearity with lower temperature, the cause of which is still under investigation. Our results should help contribute to the understanding and future design of highly linear cryogenic quantum links.

Bolton, Summer↗