Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Source location of Jupiter's decametric radiation and UV aurora

The source region of a component of Jovian Io-unrelated decametric radiation is inferred geometrically based on simultaneous observations from Voyager spacecraft and a ground-based observatory with the aid of a hollow cone beam model and model of the Jovian magnetic field. The results indicate that the sources of this component lie above the northern hemisphere, and on field lines that connect the Io plasma torus and the Jovian ionosphere in the so-called active sector. It is concluded that an interaction between the Io-torus plasma and the ionospheric plasma through a thin flux tube initiates the decametric radiation.

Maeda, Koitiro↗

Simulated Performance of Algorithms for the Localization of Radioactive Sources from a Position Sensitive Radiation Detecting System (COCAE)

Simulation studies are presented regarding the performance of algorithms that localize point-like radioactive sources detected by a position sensitive portable radiation instrument (COCAE). The source direction is estimated by using the List Mode Maximum Likelihood Expectation Maximization (LM-ML-EM) imaging algorithm. Furthermore, the source-to-detector distance is evaluated by three different algorithms based on the photo-peak count information of each detecting layer, the quality of the reconstructed source image, and the triangulation method. These algorithms have been tested on a large number of simulated photons over a wide energy range (from 200 keV to 2 MeV) emitted by point-like radioactive sources located at different orientations and source-to-detector distances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface Detection in a STXM Microscope

We have modified scanning transmission x-ray microscopes (STXM) at the Canadian Light Source and the Advanced Light Source with total electron yield (TEY) detection (TEY-STXM). This provides improved surface-sensitive detection, simultaneous with existing bulk-sensitive transmission detection in the STXM microscopes. We have explored sample-current and channeltron-based electron yield detection. Both approaches provide improved surface sensitive imaging and spectroscopy, although channeltron-based detection is superior. TEY-STXM provides surface sensitive imaging of ultrathin films such as phase-separated Langmuir-Blodgett monolayer films, as well as differentiation of surface and bulk oxides of patterned metallic thin films. This paper will outline the experimental challenges of this method and the opportunities for correlative surface and bulk measurements of complex samples.

07 ISOTOPE AND RADIATION SOURCES↗

TESTING OF THE RADBALL TECHNOLOGY AT SAVANNAH RIVER NATIONAL LABORATORY

The United Kingdom's National Nuclear Laboratory (NNL) has developed a remote, nonelectrical, radiation-mapping device known as RadBall (patent pending), which offers a means to locate and quantify radiation hazards and sources within contaminated areas of the nuclear industry. Positive results from initial deployment trials in nuclear waste reprocessing plants at Sellafield in the United Kingdom and the anticipated future potential use of RadBall throughout the U.S. Department of Energy Complex have led to the NNL partnering with the Savannah River National Laboratory (SRNL) to further test, underpin, and strengthen the technical performance of the technology. The study completed at SRNL addresses key aspects of the testing of the RadBall technology. The first set of tests was performed at Savannah River Nuclear Solutions Health Physics Instrument Calibration Laboratory (HPICL) using various gamma-ray sources and an x-ray machine with known radiological characteristics. The objective of these preliminary tests was to identify the optimal dose and collimator thickness. The second set of tests involved a highly contaminated hot cell. The objective of this testing was to characterize a hot cell with unknown radiation sources. The RadBall calibration experiments and hot cell deployment were successful in that for each trial radiation tracks were visible. The deployment of RadBall can be accomplished in different ways depending on the size and characteristics of the contaminated area (e.g., a hot cell that already has a crane/manipulator available or highly contaminated room that requires the use of a remote control device with sensor and video equipment to position RadBall). This report also presents SRNL-designed RadBall accessories for future RadBall deployment (a harness, PODS, and robot).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The dedicated QEXAFS facility at the SLS: Performance and Scientific Opportunities

The SuperXAS beamline at the Swiss Light Source (SLS) features a permanently installed monochromator for quick scanning EXAFS (QEXAFS) spectroscopy in series with a conventional double crystal monochromator (DCM). All installed optical components like collimating and focussing mirrors can be used by both devices. The remote exchange of the monochromators is possible in less than five minutes while maintaining the beam geometry on the sample. The QEXAFS system allows fast absorption scans down to the millisecond range for the investigation of time dependent processes. Using a Si(111) channel cut crystal the energy range from 5-16 keV can be covered, with a Si(311) cut the range 9.5-30 keV. Usually a quick scanning interval of 0.1 deg. - 2 deg. in Bragg angle is selected, thus covering XANES, full EXAFS or multiple edge scans of e.g. all L-edges of a heavy element. Up to about 80 spectra per second can be collected, corresponding to a time resolution of 12.5 ms. The high intensity of the beamline even facilitates fluorescence measurements on dilute samples.

43 PARTICLE ACCELERATORS↗

Radiation efficiency of earthquake sources at different hierarchical levels

Such factors as earthquake size and its mechanism define common trends in alteration of radiation efficiency. The macroscopic parameter that controls the efficiency of a seismic source is stiffness of fault or fracture. The regularities of this parameter alteration with scale define several hierarchical levels, within which earthquake characteristics obey different laws. Small variations of physical and mechanical properties of the fault principal slip zone can lead to dramatic differences both in the amplitude of released stress and in the amount of radiated energy.

42 ENGINEERING↗

Evidence for halo-like radio sources from kilometric type III burst observations

The radio azimuths for many kilometric type III bursts that originate near or behind the limb of the sun are observed to drift far to the east or far to the west of the spacecraft-sun line. It is shown that the behavior of the observed burst parameters for these events corresponds to the response of a spinning dipole antenna to halolike sources of radiation around the sun. These results provide evidence for a previous suggestion that behind-the-limb type III events should appear as halolike sources of radiation to an observer on the opposite side of the sun, due to scattering of the radiation from the primary source back around the sun.

Reiner, M. J.↗

In situ deformation of antigorite-olivine two-phase mixtures: Implications for dynamics and seismic anisotropy in the mantle wedge

Water released from hydrous minerals in subducting slabs reacts with the overlying plate, resulting in widespread serpentinization in the mantle wedge. Deformation of serpentinized peridotites has been invoked to explain forearc seismic anisotropy, yet studies of the mechanical properties and deformation behaviors of serpentine-bearing multiphase aggregates remain limited. Here we deformed olivine-antigorite mixtures containing 70, 50, and 20 vol.% of antigorite at 2.5 – 7.6 GPa, 673 K and strain rates of ∼10 –5 –10 –4 s –1 . Elasto-viscoplastic self-consistent simulations, constrained by synchrotron X-ray diffraction (XRD) data, were used to estimate lattice strain, stress–strain partitioning, crystallographic preferred orientations (CPO) development, and aggregate strength. Selected run products were also analyzed by electron backscatter diffraction for comparison with the CPO results obtained from XRD experiments. We found olivine transitions from A- or B-type to C-type when antigorite fraction drops to 20 vol.%, coinciding with a microstructural change from interconnected weak layers to a load-bearing framework (LBF). An additional run on a sample Atg50/Ol50 with preexisting microstructures suggested the formation of LBF was promoted by these microstructures, although the preexisting antigorite CPO has been overprinted at 20.8 % strain and could be erased completely by subsequent deformation in nature. Estimated viscosity of the two-phase mixtures suggests that low-degree serpentinization (≤20 %) in the mantle wedge may increase the strength of olivine-rich peridotite and hinder slab-mantle decoupling, whereas high-degree serpentinization (≥50–70 %) weakens the peridotite and favors decoupling if sufficient viscosity contrast (>10) develops. Seismic anisotropy shows a nonlinear dependence on antigorite fraction: antigorite CPO governs the anisotropy of the mixtures with ≥50 vol.% antigorite, whereas olivine CPO dominates at low fractions (∼20 vol.%). The presence of pre-existing microstructures reduces seismic anisotropy of the deformed mixtures, however the persistence of pre-existing CPO in actively subducting slabs remains uncertain, making their significance over geological timescales questionable.

Crystallographic preferred orientation↗

Connectivity-Dependent Exciton–Phonon Coupling in Cesium Bismuth Halide Quantum Dots

Metal halide octahedra form the fundamental functional building blocks of metal halide perovskites, dictating their structures, optical properties, electronic structures, and dynamics. Here, in this study, we show that the connectivity of bismuth halide octahedra in Cs 3 Bi 2 Br 9 and Cs 3 Bi 2 I 9 quantum dots (QDs) changes with different halide elements. We use first-principles calculations to reveal the key role of the connectivity of bismuth halide octahedra on the wave function symmetry, Huang-Rhys factor, and exciton-phonon interaction strength. Following QD synthesis via a ligand-mediated transport method, the effect of connectivity is verified with transient absorption spectroscopy, where we contrast Cs 3 Bi 2 Br 9 and Cs 3 Bi 2 I 9 QD exciton dynamics. In photoexcited Cs 3 Bi 2 I 9 QDs, phonons related to the vibrational motions of face-sharing [BiI 6 ] 3- bioctahedra couple strongly to the electronic state and drive rapid carrier relaxation. Equivalent signals are not observed for photoexcited Cs 3 Bi 2 Br 9 QDs, implying a lack of phonon involvement in band-edge absorption and subsequent exciton relaxation. Our findings suggest that structural engineering can effectively tune the exciton-phonon coupling and therefore influence exciton relaxation and recombination in perovskite nanomaterials.

TDDFT↗

Some consequences of intense electromagnetic wave injection into space plasmas

The future possibility of actively testing the current understanding of how energetic particles may be accelerated in space or dumped from the radiation belts using intense electromagnetic energy from ground based antennas is discussed. The ground source of radiation is merely a convenience. A space station source for radiation that does not have to pass through the atmosphere and lower ionosphere, is an attractive alternative. The text is divided into two main sections addressing the possibilities of: (1) accelerating electrons to fill selected flux tubes above the Kennel-Petscheck limit for stably trapped fluxes, and (2) using an Alfven maser to cause rapid depletion of energetic protons or electrons from the radiation belts.

Burke, William J.↗

Pulse Compression of Nd:YAG Laser with Stimulated Brillouin Scattering for Compton Backscattered X-ray Source

Compton backscattered x-ray source is developed in the energy region of a few hundred keV at Kansai Photon Science Institute of Japan Atomic Energy Agency (KPSI-JAEA). A remarkable feature of the Compton backscattered x-ray source is that the generated x-ray beam is a well-collimated and has a definite polarization property. The Compton backscattered x-ray source at KPSI-JAEA consists of the 150-MeV electron beam with the pulse duration of 24 ps accelerated by Microtron accelerator and a Nd:YAG laser with the pulse duration of 23 ns. At the first trial of the X-ray generation, the x-ray flux is not enough for actual use. As an actual x-ray source, it is important to increase the generated x-ray flux as much as possible. Thus, in order to increase the x-ray flux, we develop the pulse compression system for the Nd:YAG laser through the stimulated Brillouin scattering (SBS). The SBS pulse compression is characterized by its high conversion efficiency and by its simplicity of construction. On this article, we describe the present status of the SBS pulse compression for the Compton backscattered x-ray source at KPSI-JAEA.

07 ISOTOPE AND RADIATION SOURCES↗

Source region of the smooth high-frequency nightside Uranus kilometric radiation - A ray-tracing study

This paper presents a plasma density model for the Uranus nightside at r less than 4.2 r(u), developed on the basis of radio wave observations of the Planetary Radio Astronomy instrument on board the Voyager 2 spacecraft and on cyclotron maser instability. The results provide an accurate description of the Uranus kilometric radiation (UKR) source region dependent on a minimum of assumptions, and indicate that the UKR source region is more extended in longitude than previosly determined.

Menietti, J. D.↗

THE QUaD GALACTIC PLANE SURVEY. II. A COMPACT SOURCE CATALOG

We present a catalog of compact sources derived from the QUaD Galactic Plane Survey. The survey covers {approx}800 deg{sup 2} of the inner galaxy (|b| < 4{sup 0}) in Stokes I, Q, and U parameters at 100 and 150 GHz, with angular resolutions of 5 and 3.5 arcmin, respectively. Five hundred and twenty-six unique sources are identified in I, of which 239 are spatially matched between frequency bands, with 53 (234) detected at 100 (150) GHz alone; 170 sources are identified as ultracompact H II regions. Approximating the distribution of total intensity source fluxes as a power law, we find a slope of {gamma}{sub S,100} = -1.8 {+-} 0.4 at 100 GHz and {gamma}{sub S,150} = -2.2 {+-} 0.4 at 150 GHz. Similarly, the power-law index of the source two-point angular correlation function is {gamma}{sub {theta},100} = -1.21 {+-} 0.04 and {gamma}{sub {theta},150} = -1.25 {+-} 0.04. The total intensity spectral index distribution peaks at {alpha}{sub I} {approx} 0.25, indicating that dust emission is not the only source of radiation produced by these objects between 100 and 150 GHz; free-free radiation is likely significant in the 100 GHz band. Four sources are detected in polarized intensity P, of which three have matching counterparts in I. Three of the polarized sources lie close to the Galactic center, Sagittarius A*, Sagittarius B2, and the Galactic Radio Arc, while the fourth is RCW 49, a bright H II region. An extended polarized source, undetected by the source extraction algorithm on account of its {approx}0.{sup 0}5 size, is identified visually, and is an isolated example of large-scale polarized emission oriented distinctly from the bulk Galactic dust polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

A fine-focusing x-ray source using carbon-nanofiber field emitter

A fine-focusing x-ray source has been constructed employing a field electron emitter prepared by growing carbon-nanofibers (CNFs) on a metal tip. The x-ray source is composed of a CNF field electron emitter, an electrostatic lens, two magnetic lenses, and a W-target for generating x-rays by electron impact. The CNFs provided field electrons with a current density of J{approx}5x10{sup 9} A/m{sup 2}, which was evaluated with the aid of Fowler-Nordheim theory. The electron beam extracted from the CNF emitter was accelerated to the energies of E=10-25 keV, and then focused by the lenses. By recording the x-ray images of test charts, the optimum resolution of the x-ray source was estimated to be approximately D{sub x}=0.5 {mu}m.

07 ISOTOPE AND RADIATION SOURCES↗

The New Structural Materials Science Beamlines BL8A and 8B at Photon Factory

BL8A and 8B are new beamlines for structural materials science at Photon Factory. The primary characteristics of both beamlines are similar. The incident beam is monochromatized by the Si(111) double-flat crystal monochromator and focused at the sample position by a Rh-coated bent cylindrical quartz mirror. The Weissenberg-camera-type imaging-plate (IP) diffractometers were installed. The X-ray diffraction experiments for structural studies of strongly correlated materials, such as transition metals, molecular conductors, endohedral fullerenes, nano-materials, etc, are conducted at these stations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Super-radiance in the sodium resonance lines from sodium iodide arc lamps

Super-radiance observed within the centers of the sodium resonance D lines emitted by arc lamps containing sodium iodide as additive in a high-pressure mercury plasma environment was studied by high-resolution emission spectroscopy. The spectral radiance of these self-reversed lines including super-radiance was simulated by considering a local enhancement of the source function due to the presence of an additional source of radiation near the arc wall. Causes of this hitherto unrecognized source of radiation are given.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗