Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Protection & Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

MO-AB-210-02: Ultrasound Imaging and Therapy-Hands On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

Development of a First-of-a-Kind Deterministic Decision-Making Tool for Supervisory Control System

Decision-making is the process of identifying and choosing alternatives where each alternative offers a different approach or path to move from a given state or condition to a desired state or condition. The generation of consistent decisions requires that a structured, coherent process be defined, immediately leading to a decision-making framework. The overall objective of the generalized framework is for it to be adopted into an autonomous decision-making framework and tailored to specific requirements for various applications. In this context, automation is the use of computing resources to make decisions and implement a structured decision-making process with limited or no human intervention. The overriding goal of automation is to replace or supplement human decision makers with reconfigurable decision- making modules that can perform a given set of tasks reliably. Risk-informed decision making requires a probabilistic assessment of the likelihood of success given the status of the plant/systems and component health, and a deterministic assessment between plant operating parameters and reactor protection parameters to prevent unnecessary trips and challenges to plant safety systems. The implementation of the probabilistic portion of the decision-making engine of the proposed supervisory control system was detailed in previous milestone reports. Once the control options are identified and ranked based on the likelihood of success, the supervisory control system transmits the options to the deterministic portion of the platform. The deterministic multi-attribute decision-making framework uses variable sensor data (e.g., outlet temperature) and calculates where it is within the challenge state, its trajectory, and margin within the controllable domain using utility functions to evaluate current and projected plant state space for different control decisions. Metrics to be evaluated include stability, cost, time to complete (action), power level, etc. The integration of deterministic calculations using multi-physics analyses (i.e., neutronics, thermal, and thermal-hydraulics) and probabilistic safety calculations allows for the examination and quantification of margin recovery strategies. This also provides validation of the control options identified from the probabilistic assessment. Thus, the thermal-hydraulics analyses are used to validate the control options identified from the probabilistic assessment. Future work includes evaluating other possible metrics and computational efficiencies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Atmospheric Tracer Depletion Testing for Unfiltered Air In-Leakage Determination at the Wolf Creek Nuclear Power Plant

Atmospheric Tracer Depletion tests were conducted at the Wolf Creek Nuclear Power Plant to quantify the unfiltered in-leakage (UI) into the Control Room (CR), Control Building (CB), and Equipment Rooms (ER) at the Wolf Creek Nuclear Power Plant. Wolf Creek has two independent charcoal filter Emergency Ventilation Systems (EVS) that can be used to purify air entering the control building and control room. The Bravo System contains a filtration system in Room 1501 in the Auxiliary Building for the Control Room and another filtration system (FGK02B) on Elevation 2016 for the Control Building. The Alpha system contains a filtration system in Room 1512 in the Auxiliary Building for the Control Room and another filtration system (FGK02A) on Elevation 2016 for the Control Building. The Atmospheric Tracer Depletion (ATD) test is a technique to measure in-leakage using the concentration of perfluorocarbon compounds that have a constant atmospheric background. These levels are present in the Control Room and Control Building under normal operating conditions. When air is supplied by either of the EVS, most of the PFTS are removed by the charcoal filters. If the concentrations of the PFTs measured in protected areas are the same as the levels at the output of the EVS, the in-leakage of outside air into the protected area would be zero. If the concentration is higher in the protected area than at the output of the filter system, there is in-leakage and the in-leakage can be quantified by the difference. Sampling was performed using state-of-the-art Brookhaven Atmospheric Tracer Samplers (BATS) air sampling equipment and analysis performed on Brookhaven National Laboratory (BNL) dedicated PFT analytical systems. In the Alpha test two tracers PMCH and mcPDCH were used to determine in-leakage into the control building. The analytical system was tuned to maximize sensitivity after initial analysis of the Alpha test. The increased sensitivity permitted accurate quantification of five isomers of the PFT PDCH (mtPDCH, pcPDCH, otPDCH, mcPDCH, and ptPDCH). These isomers were quantified in the low concentration samples in the Alpha test and in all samples in the Bravo test. The best estimates of UI (Rui) for the four zones are provided in Table ES-1. For the CB, this estimate averages the four tracers at the four elevations. For the CR, this estimate uses the four sampling units located in the Control Room.

54 ENVIRONMENTAL SCIENCES↗

Challenges at the Frontiers of Matter and Energy: Transformative Opportunities for Discovery Science

FIVE TRANSFORMATIVE OPPORTUNITIES FOR DISCOVERY SCIENCE As a result of this effort, it has become clear that the progress made to date on the five Grand Challenges has created a springboard for seizing five new Transformative Opportunities that have the potential to further transform key technologies involving matter and energy. These five new Transformative Opportunities and the evidence supporting them are discussed in this new report, “Challenges at the Frontiers of Matter and Energy: Transformative Opportunities for Discovery Science.” Mastering Hierarchical Architectures and Beyond-Equilibrium Matter Complex materials and chemical processes transmute matter and energy, for example from CO2 and water to chemical fuel in photosynthesis, from visible light to electricity in solar cells and from electricity to light in light emitting diodes (LEDs) Such functionality requires complex assemblies of heterogeneous materials in hierarchical architectures that display time-dependent away-from-equilibrium behaviors. Much of the foundation of our understanding of such transformations however, is based on monolithic single- phase materials operating at or near thermodynamic equilibrium. The emergent functionalities enabling next-generation disruptive energy technologies require mastering the design, synthesis, and control of complex hierarchical materials employing dynamic far-from-equilibrium behavior. A key guide in this pursuit is nature, for biological systems prove the power of hierarchical assembly and far- from-equilibrium behavior. The challenges here are many: a description of the functionality of hierarchical assemblies in terms of their constituent parts, a blueprint of atomic and molecular positions for each constituent part, and a synthesis strategy for (a) placing the atoms and molecules in the proper positions for the component parts and (b) arranging the component parts into the required hierarchical structure. Targeted functionality will open the door to significant advances in the harvesting, transforming (e.g., reducing CO2, splitting water, and fixing nitrogen), storing, and use of energy to create new materials, manufacturing processes, and technologies—the lifeblood of human societies and economic growth. Beyond Ideal Materials and Systems: Understanding the Critical Roles of Heterogeneity, Interfaces, and Disorder Real materials, both natural ones and those we engineer, are usually a complex mixture of compositional and structural heterogeneities, interfaces, and disorder across all spatial and temporal scales. It is the fluctuations and disorderly states of these heterogeneities and interfaces that often determine the system’s properties and functionality. Much of our fundamental scientific knowledge is based on “ideal” systems, meaning materials that are observed in “frozen” states or represented by spatially or temporally averaged states. Too often, this approach has yielded overly simplistic models that hide important nuances and do not capture the complex behaviors of materials under realistic conditions. These behaviors drive vital chemical transformations such as catalysis, which initiates most industrial manufacturing processes, and friction and corrosion, the parasitic effects of which cost the U.S. economy billions of dollars annually. Expanding our scientific knowledge from the relative simplicity of ideal, perfectly ordered, or structurally averaged materials to the true complexity of real-world heterogeneities, interfaces, and disorder should enable us to realize enormous benefits in the materials and chemical sciences, which translates to the energy sciences, including solar and nuclear power, hydraulic fracturing, power conversion, airframes, and batteries. Harnessing Coherence in Light and Matter Quantum coherence in light and matter is a measure of the extent to which a wave field vibrates in unison with itself at neighboring points in space and time. Although this phenomenon is expressed at the atomic and electronic scales, it can dominate the macroscopic properties of materials and chemical reactions such as superconductivity and efficient photosynthesis. In recent years, enormous progress has been made in recognizing, manipulating, and exploiting quantum coherence. This progress has already elucidated the role that symmetry plays in protecting coherence in key materials, taught us how to use light to manipulate atoms and molecules, and provided us with increasingly sophisticated techniques for controlling and probing the charges and spins of quantum coherent systems. With the arrival of new sources of coherent light and electron beams, thanks in large part to investments by the U.S. Department of Energy’s Office of Basic Energy Sciences (BES), there is now an opportunity to engineer coherence in heterostructures that incorporate multiple types of materials and to control complex, multistep chemical transformations. This approach will pave the way for quantum information processing and next-generation photovoltaic cells and sensors. Revolutionary Advances in Models, Mathematics, Algorithms, Data, and Computing Science today is benefiting from a convergence of theoretical, mathematical, computational, and experimental capabilities that put us on the brink of greatly accelerating our ability to predict, synthesize, and control new materials and chemical processes, and to understand the complexities of matter across a range of scales. Imagine being able to chart a path through a vast sea of possible new materials to find a select few with desired properties. Instead of the time-honored forward approach, in which materials with desired properties are found through either trial-and-error experiments or lucky accidents, we have the opportunity to inversely design and create new materials that possess the properties we desire. The traditional approach has allowed us to make only a tiny fraction of all the materials that are theoretically possible. The inverse design approach, through the harmonious convergence of theoretical, mathematical, computational, and experimental capabilities, could usher in a virtual cornucopia of new materials with functionalities far beyond what nature can provide. Similarly, enhanced mathematical and computational capabilities significantly enhance our ability to extract physical and chemical insights from vastly larger data streams gathered during multimodal and multidimensional experiments using advanced characterization facilities. Exploiting Transformative Advances in Imaging Capabilities across Multiple Scales Historically, improvements in imaging capabilities have always resulted in improved understanding of scientific phenomena. A prime challenge today is finding ways to reconstruct raw data, obtained by probing and mapping matter across multiple scales, into analyzable images. BES investments in new and improved imaging facilities, most notably synchrotron x-ray sources, free-electron lasers, electron microscopes, and neutron sources, have greatly advanced our powers of observation, as have substantial improvements in laboratory- scale technologies. Furthermore, BES is now planning or actively discussing exciting new capabilities. Taken together, these advances in imaging capabilities provide an opportunity to expand our ability to observe and study matter from the 3D spatial perspectives of today to true “4D” spatially and temporally resolved maps of dynamics that allow quantitative predictions of time-dependent material properties and chemical processes. The knowledge gained will impact data storage, catalyst design, drug delivery, structural materials, and medical implants, to name just a few key technologies. ENABLING SUCCESS Seizing each of these five Transformative Opportunities, as well as accelerating further progress on Grand Challenge research, will require specific, targeted investments from BES in the areas of synthesis, meaning the ability to make the materials and architectures that are envisioned; instrumentation and tools, a category that includes theory and computation; and human capital, the most important asset for advancing the Grand Challenges and Transformative Opportunities. While “Challenges at the Frontiers of Matter and Energy: Transformative Opportunities for Discovery Science” could be viewed as a sequel to the original Grand Challenges report, it breaks much new ground in its assessment of the scientific landscape today versus the scientific landscape just a few years ago. In the original Grand Challenges report, it was noted that if the five Grand Challenges were met, our ability to direct matter and energy would be measured only by the limits of human imagination. This new report shows that, prodded by those challenges, the scientific community is positioned today to seize new opportunities whose impacts promise to be transformative for science and society, as well as dramatically accelerate progress in the pursuit of the original Grand Challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating a Microgrid Controller with a Local OpenADR Server

When military microgrids isolate themselves from the main electrical grid, they must locally balance electricity supply and demand. Since local generation may be limited, the current strategy is to shed all but the most critical loads by tripping smart circuit breakers, which must then be reset manually (e.g., ESTCP project EW-201350). This strategy is typically applied at the building level, meaning that entire buildings housing mission critical activities must be excluded from any load management, while those considered non-critical may lose service entirely. The remotely controlled switchgear needed to manage load in this way is very expensive ($\$30,000$-$\$50,000$ per building). While effective at shedding load, this strategy disrupts installation operation and risks damaging equipment during both disconnection and re-energization. With the goals of lowering costs, protecting equipment, and enhancing the agility of DoD microgrids, this report demonstrates the use of cybersecure automated demand response (ADR) technology to manage microgrid loads during grid-independent (a.k.a. "islanded") operation. This automated approach achieves load shedding and shifting through communication signals sent to equipment controllers rather than by cutting off the flow of electricity within the microgrid itself. Because it operates only on the base network, with no connection to external entities, this strategy avoids the main cybersecurity concern raised by past applications of ADR on military bases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Prediction of human observer performance in a 2-alternative forced choice low-contrast detection task using channelized Hotelling observer: Impact of radiation dose and reconstruction algorithms

Purpose: Efficient optimization of CT protocols demands a quantitative approach to predicting human observer performance on specific tasks at various scan and reconstruction settings. The goal of this work was to investigate how well a channelized Hotelling observer (CHO) can predict human observer performance on 2-alternative forced choice (2AFC) lesion-detection tasks at various dose levels and two different reconstruction algorithms: a filtered-backprojection (FBP) and an iterative reconstruction (IR) method. Methods: A 35 Multiplication-Sign 26 cm{sup 2} torso-shaped phantom filled with water was used to simulate an average-sized patient. Three rods with different diameters (small: 3 mm; medium: 5 mm; large: 9 mm) were placed in the center region of the phantom to simulate small, medium, and large lesions. The contrast relative to background was -15 HU at 120 kV. The phantom was scanned 100 times using automatic exposure control each at 60, 120, 240, 360, and 480 quality reference mAs on a 128-slice scanner. After removing the three rods, the water phantom was again scanned 100 times to provide signal-absent background images at the exact same locations. By extracting regions of interest around the three rods and on the signal-absent images, the authors generated 21 2AFC studies. Each 2AFC study had 100 trials, with each trial consisting of a signal-present image and a signal-absent image side-by-side in randomized order. In total, 2100 trials were presented to both the model and human observers. Four medical physicists acted as human observers. For the model observer, the authors used a CHO with Gabor channels, which involves six channel passbands, five orientations, and two phases, leading to a total of 60 channels. The performance predicted by the CHO was compared with that obtained by four medical physicists at each 2AFC study. Results: The human and model observers were highly correlated at each dose level for each lesion size for both FBP and IR. The Pearson's product-moment correlation coefficients were 0.986 [95% confidence interval (CI): 0.958-0.996] for FBP and 0.985 (95% CI: 0.863-0.998) for IR. Bland-Altman plots showed excellent agreement for all dose levels and lesions sizes with a mean absolute difference of 1.0%{+-} 1.1% for FBP and 2.1%{+-} 3.3% for IR. Conclusions: Human observer performance on a 2AFC lesion detection task in CT with a uniform background can be accurately predicted by a CHO model observer at different radiation dose levels and for both FBP and IR methods.

60 APPLIED LIFE SCIENCES↗

Walk the Talk: Progress in Building a Supply Chain Security Culture

Pacific Northwest National Laboratory (PNNL) has engaged industry to “go beyond compliance” for over a decade in controlling and securing their supply chains to ensure their goods are not diverted to nuclear weapons programs. This work has focused on dual-use industries that manufacture products that can be used in both commercial applications and in the development of a nuclear weapon. The team encourages industry to self-regulate to reduce proliferation risks. As part of that work, PNNL interviewed numerous companies about their compliance practices to understand their business and to build awareness around best practices to ensure security of goods, technology, and information along their supply chains. From conducting this work, PNNL identified indicators that a company can adopt as part of its commitment to nonproliferation ideals with a focus on supply chain security.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Post-exposure treatment with nasal atropine methyl bromide protects against microinstillation inhalation exposure to sarin in guinea pigs

We evaluated the protective efficacy of nasal atropine methyl bromide (AMB) which does not cross the blood-brain barrier against sarin inhalation exposure. Age and weight matched male guinea pigs were exposed to 846.5 mg/m{sup 3} sarin using a microinstillation inhalation exposure technique for 4 min. The survival rate at this dose was 20%. Post-exposure treatment with nasal AMB (2.5 mg/kg, 1 min) completely protected against sarin induced toxicity (100% survival). Development of muscular tremors was decreased in animals treated with nasal AMB. Post-exposure treatment with nasal AMB also normalized acute decrease in blood oxygen saturation and heart rate following sarin exposure. Inhibition of blood AChE and BChE activities following sarin exposure was reduced in animals treated with nasal AMB, indicating that survival increases the metabolism of sarin or expression of AChE. The body weight loss of animals exposed to sarin and treated with nasal AMB was similar to saline controls. No differences were observed in lung accessory lobe or tracheal edema following exposure to sarin and subsequent treatment with nasal AMB. Total bronchoalveolar lavage fluid (BALF) protein, a biomarker of lung injury, showed trends similar to saline controls. Surfactant levels post-exposure treatment with nasal AMB returned to normal, similar to saline controls. Alkaline phosphatase levels post-exposure treatment with nasal AMB were decreased. Taken together, these data suggest that nasal AMB blocks the copious airway secretion and peripheral cholinergic effects and protects against lethal inhalation exposure to sarin thus increasing survival.

60 APPLIED LIFE SCIENCES↗

Dose optimization in pediatric cardiac x-ray imaging

Purpose: The aim of this research was to explore x-ray beam parameters with intent to optimize pediatric x-ray settings in the cardiac catheterization laboratory. This study examined the effects of peak x-ray tube voltage (kVp) and of copper (Cu) x-ray beam filtration independently on the image quality to dose balance for pediatric patient sizes. The impact of antiscatter grid removal on the image quality to dose balance was also investigated. Methods: Image sequences of polymethyl methacrylate phantoms approximating chest sizes typical of pediatric patients were captured using a modern flat-panel receptor based x-ray imaging system. Tin was used to simulate iodine-based contrast medium used in clinical procedures. Measurements of tin detail contrast and flat field image noise provided the contrast to noise ratio. Entrance surface dose (ESD) and effective dose (E) measurements were obtained to calculate the figure of merit (FOM), CNR{sup 2}/dose, which evaluated the dose efficiency of the x-ray parameters investigated. The kVp, tube current (mA), and pulse duration were set manually by overriding the system's automatic dose control mechanisms. Images were captured with 0, 0.1, 0.25, 0.4, and 0.9 mm added Cu filtration, for 50, 55, 60, 65, and 70 kVp with the antiscatter grid in place, and then with it removed. Results: For a given phantom thickness, as the Cu filter thickness was increased, lower kVp was favored. Examining kVp alone, lower values were generally favored, more so for thinner phantoms. Considering ESD, the 8.5 cm phantom had the highest FOM at 50 kVp using 0.4 mm of Cu filtration. The 12 cm phantom had the highest FOM at 55 kVp using 0.9 mm Cu, and the 16 cm phantom had highest FOM at 55 kVp using 0.4 mm Cu. With regard to E, the 8.5 and 12 cm phantoms had the highest FOM at 50 kVp using 0.4 mm of Cu filtration, and the 16 cm phantom had the highest FOM at 50 kVp using 0.25 mm Cu. Antiscatter grid removal improved the FOM for a given set of x-ray conditions. Under aforesaid optimal settings, the 8.5 cm phantom FOM improved by 24% and 33% for ESD and E, respectively. Corresponding improvements were 26% and 24% for the 12 cm phantom and 6% and 15% for the 16 cm phantom. Conclusions: For pediatric patients, using 0.25-0.9 mm Cu filtration in the x-ray beam while maintaining 50-55 kVp, depending on patient size, provided optimal x-ray image quality to dose ratios. These settings, adjusted for x-ray tube loading limits and clinically acceptable image quality, should provide a useful strategy for optimizing iodine contrast agent based cardiac x-ray imaging. Removing the antiscatter grid improved the FOM for the 8.5 and 12 cm phantoms, therefore grid removal is recommended for younger children. Improvement for the 16 cm phantom declined into the estimated margin of error for the FOM; the need for grid removal for older children would depend on practical feasibility in the clinical environment.

60 APPLIED LIFE SCIENCES↗

Dosimetry and Image Quality in Control Studies in Computerised Tomography Realized to Paediatric Patients

Computerised tomography (CT) is a favourite method of medical diagnosis. Its use has thus increased rapidly throughout the world, particularly in studies relating to children. However to avoid administering unnecessarily high doses of radiation to paediatric patients it is important to have correct dose reference levels to minimize risk. The research is being developed within the public health sector at the Hospital Infantil de Mexico 'Dr. Federico Gomez.' We measured the entrance surface air kerma (K{sub P}) in paediatric patients, during the radiological studies of control in CT (studies of head, thorax and abdomen). Phantom was used to evaluate image quality as the tomograph requires a high resolution image in order to operate at its optimum level.

61 RADIATION PROTECTION AND DOSIMETRY↗

Beamline Control and Instrumentation System using Industrial Interface Techniques

How should a beamline be designed, which satisfies the needs and requirements of scientists and is easy to build and operate? Today, most control and instrumentation systems for beamlines are based on scientific requirements. Scientific details of the beamline, e.g. vacuum and beam physics details; are usually extensively described. However, control system specifications are often reduced to few requirements, e.g. which beam-related device to use. Lots of these systems work perfectly from the physicist's point of view, but are hard to bring into service and operate and difficult to extend with additional equipment. To overcome this, the engineering company ENZ has developed components using industrial standard interfaces to guarantee high flexibility for equipment extension. Using special interface boards and galvanic isolation offers increased stability of motion control axes. This saves resources during commissioning and service. A control system was developed and installed at a Soft-X-ray beamline at ASP Melbourne. It is operated under EPICs on distributed embedded IOC's based on PC-hardware. Motion and vacuum systems, measurement devices, e.g. a Low-Current Monitor (LoCuM) for beam position monitoring, and parts of the equipment protection system were developed and most of them tested in cooperation with DELTA at the Technical University of Dortmund.

43 PARTICLE ACCELERATORS↗

Risk-based area of review estimation in overpressured reservoirs to support injection well storage facility permit requirements for CO 2 storage projects

This paper by the Energy & Environmental Research Center presents a workflow and modeling approach for delineating a risk-based area of review (AOR) to support a U.S. Environmental Protection Agency (EPA) Class VI permit for a carbon dioxide (CO 2 ) storage project. The approach combines semianalytical solutions for estimating formation fluid leakage through a hypothetical leaky wellbore with the results of numerical reservoir simulations to define the AOR. The modeling utilizes 1) semianalytical solutions from the peer-reviewed literature for formation fluid leakage through abandoned wellbores by Raven (1990) and Avci (1994), 2) a FORTRAN model compiled and described in Cihan et al. (2011, 2012) called ASLMA (Analytical Solution for Leakage in Multilayered Aquifers), and 3) a computational framework for estimating a risk-based AOR first proposed by Oldenburg et al. (2014, 2016). Therefore, the approach builds upon well-established research and underlying hydrogeological principles that have been upheld for nearly three decades. Moreover, the ASLMA model has been broadly applied to an array of storage projects. The work presented herein extends these earlier works using a custom wrapper written in the software environment, R (R Core Team, 2020), which was developed to perform multiple runs of the ASLMA model using given ranges for one or more input parameters. In addition, the current work simulates the pressure buildup within the storage reservoir in response to CO 2 injection using a compositional simulator to better accommodate the temporospatial evolution of pressure buildup within the storage reservoir that is more accurately modeled using a heterogeneous geologic model and a compositional simulator that accounts for the multiphase interactions. The workflow is demonstrated using a case study for a 180,000-metric-ton-per-year storage project located in the PCOR (Plains CO 2 Reduction) Partnership region. For the storage project evaluated here, under the scenario where the leaky wellbore is open to a saline aquifer (thief zone) between the overlying seal (cap rock) and the underground sources of drinking water (USDW), the risk-based AOR essentially collapses to the areal extent of the CO 2 plume in the storage reservoir because the pressure buildup in the storage reservoir beyond the CO 2 plume is insufficient to drive formation fluids up a hypothetical leaky wellbore into the USDW. However, even under the conservative assumption that the leaky wellbore is not open to a thief zone, beyond the areal extent of the CO 2 plume, the incremental leakage is less than 400 m 3 over 20 years, which represents ~0.0001% or less of the total volume of water contained within the USDW rock volume. As discussed in the text, the threshold criterion for defining the risk-based AOR is site-specific and should be informed by the results of the sensitivity analysis and available site characterization data. The approach outlined in this paper is designed to be protective of USDWs and, therefore, comply with the Safe Drinking Water Act requirements and provisions for the U.S. EPA Class VI Underground Injection Control (UIC) Program (Class VI Rule) and North Dakota Administrative Code Chapter 43-05-01.

54 ENVIRONMENTAL SCIENCES↗

Polymer Nanosheet Containing Star‐Like Copolymers: A Novel Scalable Controlled Release System

Abstract Poly(ε‐caprolactone) (PCL)‐based nanomaterials, such as nanoparticles and liposomes, have exhibited great potential as controlled release systems, but the difficulties in large‐scale fabrication limit their practical applications. Among the various methods being developed to fabricate polymer nanosheets (PNSs) for different applications, such as Langmuir–Blodgett technique and layer‐by‐layer assembly, are very effort consuming, and only a few PNSs can be obtained. In this paper, poly(ε‐caprolactone)‐based PNSs with adjustable thickness are obtained in large quantity by simple water exposure of multilayer polymer films, which are fabricated via a layer multiplying coextrusion method. The PNS is also demonstrated as a novel controlled guest release system, in which release kinetics are adjustable by the nanosheet thickness, pH values of the media, and the presence of protecting layers. Theoretical simulations, including Korsmeyer–Peppas model and Finite‐element analysis, are also employed to discern the observed guest‐release mechanisms.

Cao, Peng‐Fei↗

Molecular Properties That Define the Activities of Antibiotics in Escherichia coli and Pseudomonas aeruginosa

The permeability barrier of Gram-negative cell envelopes is the major obstacle in the discovery and development of new antibiotics. In Gram-negative bacteria, these difficulties are exacerbated by the synergistic interaction between two biochemically distinct phenomena, the low permeability of the outer membrane (OM) and active multidrug efflux. In this study, we used Pseudomonas aeruginosa and Escherichia coli strains with controllable permeability barriers, achieved through hyperporination of the OMs and varied efflux capacities, to evaluate the contributions of each of the barriers to protection from antibacterials. We analyzed antibacterial activities of β-lactams and fluoroquinolones, antibiotics that are optimized for targets in the periplasm and the cytoplasm, respectively, and performed a machine learning-based analysis to identify physicochemical descriptors that best classify their relative potencies. Our results show that the molecular properties selected by active efflux and the OM barriers are different for the two species. Antibiotic activity in P. aeruginosa was better classified by electrostatic and surface area properties, whereas topology, physical properties, and atom or bond counts best capture the behavior in E. coli . In several cases, descriptor values that correspond to active antibiotics also correspond to significant barrier effects, highlighting the synergy between the two barriers where optimizing for one barrier promotes strengthening of the other barrier. Furthermore, both barriers should be considered when optimizing antibiotics for favorable OM permeability, efflux evasion, or both.

59 BASIC BIOLOGICAL SCIENCES↗

Light-induced Weyl semiconductor-to-metal transition mediated by Peierls instability

Elemental tellurium is a strongly spin-orbit coupled Peierls-distorted semiconductor whose band structure features topologically protected Weyl nodes. Here, using time-dependent density functional theory calculations, we show that impulsive optical excitation can be used to transiently control the amplitude of the Peierls distortion, realizing a mechanism to switch tellurium between three states: Weyl semiconductor, Weyl metal and non-Weyl metal. Further, we present experimental evidence of this inverse-Peierls distortion using time-resolved optical second harmonic generation measurements. These results provide a pathway to multifunctional ultrafast Weyl devices and introduce Peierls systems as viable hosts of light-induced topological transitions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Forecasting and Early Warning for Adversarial Targeting in Industrial Control Systems

A new feature-based forecasting framework of abnormalities is presented for early warning for cyber-physical control systems. The abnormalities may refer to intelligent cyber-attacks or naturally occurring faults and failures. Techniques presented here are aimed at protecting against unauthorized intrusions as well as fault prevention. Time series signals from system monitoring nodes are converted to features using feature discovery techniques. The feature behavior for each monitoring node is characterized in the form of decision boundaries, separating normal and abnormal space with operating data collected from the plant or by running virtual models of the plant. A set of ensemble state-space models are constructed for representing feature evolution in time-domain, where the ensembles are selected using Gaussian Mixture Model (GMM) clustering. The forecasted outputs are anticipated time-evolution of features, computed by applying an adaptive Kalman predictor to each ensemble model. The overall features forecast is then obtained through dynamic ensemble averaging. This is done by projecting evolution of feature vector to future times in a receding horizon fashion. The features forecast are compared to the decision boundary to estimate if/when the feature vectors will cross the boundary. Simulation results in a high fidelity GE gas turbine platform, show the effectiveness of our approach for forecasting abnormalities.

42 ENGINEERING↗

A Line Impedance Conditioner for Saturation Mitigation of Zigzag Transformer in Hybrid AC/DC Transmission System Considering Line Unbalances

Hybrid ac/dc transmission extends the power transfer capacity of existing long ac lines closer to their thermal limit, by superposing the dc current onto three-phase ac lines through a zigzag transformer. However, this transformer could suffer saturation under unbalanced line impedance conditions. This paper introduces the concept of hybrid line impedance conditioner (HLIC) as a cost-effective approach to compensate for the line unbalance and therefore avoid saturation. The topology and operation principle are presented. The two-level control strategy is described, which enables autonomous adaptive regulation without the need of system-level control. Design and implementation are also analyzed, including dc-link capacitance as one of the key line conditioner components, HLIC installation, and protection under fault conditions. The cost study on this HLIC-based hybrid system is also performed to reveal the benefits of the solution. In conclusion, simulation results and experimental results based on a down-scaled prototype are provided to verify the feasibility of the proposed approach.

30 DIRECT ENERGY CONVERSION↗