Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Uncertainty Quantification for Empirical X-59 Sonic Boom Loudness Levels

Estimates of the total uncertainty for empirically determined loudness levels are documented when GRS (Ground Recording System) noise monitors are used to record X 59 sonic boom waveforms. The total uncertainty is characterized by combining nine different sources of uncertainty that may affect the apparent gain of the measurement chain. These uncertainty estimates are presented as expected measurement error relative to the true loudness level, and separate error estimates are provided for eight different noise metrics in which NASA has interest. The behavior of the Perceived Level (PL) metric is studied within the report body, while the total uncertainties for the seven other noise metrics are summarized in appendices for brevity. The effects of four sources of uncertainty are estimated simply from information found on hardware specification sheets provided by the manufacturer. However, mock acoustic recordings are created to estimate the effects of other sources because those effects are expected to induce spectral coloration, so they may vary with noise metric type and sound level. These sources are not well modeled by simple gain adjustments. Importantly, measurement error is computable when processing mock recordings since the true levels are knowable, which is not the case when processing data recorded in the field. Specifically, the true levels are knowable because the components of the mock recordings are separable – e.g., loudness levels of booms can be computed with or without superimposed background noise. Mock acoustic recordings also have the benefit of allowing analysis of sonic booms from vehicles that are not yet flying, like the X-59, since the mock recordings are created by combining vehicle-specific predicted waveforms with other audio sources. The estimates of total measurement error are documented as a function of the signal-to-noise ratio (SNR) of the loudness level, where the corrected SNR is computed while accounting for the effects of the method that is used to correct for background noise contamination when computing the noise metric values. The corrected SNR calculations used here can be applied to both mock recordings and in-field measurements, so the uncertainty of in-field recordings can be found using pre-computed lookup tables that identify the relationship between metric type, corrected SNR, and the expected measurement error.

Sonic Boom↗

Project 1640 Observations of Brown Dwarf GJ 758 B: Near-infrared Spectrum and Atmospheric Modeling

The nearby Sun-like star GJ 758 hosts a cold substellar companion, GJ 758 B, at a projected separation of ≲30 au, previously detected in high-contrast multi-band photometric observations. In order to better constrain the companion’s physical characteristics, we acquired the first low-resolution (R ∼ 50) near-infrared spectrum of it using the high-contrast hyperspectral imaging instrument Project 1640 on Palomar Observatory’s 5 m Hale telescope. We obtained simultaneous images in 32 wavelength channels covering the Y, J, and H bands (∼952–1770 nm), and used data processing techniques based on principal component analysis to efficiently subtract chromatic background speckle-noise. GJ 758 B was detected in four epochs during 2013 and 2014. Basic astrometric measurements confirm its apparent northwest trajectory relative to the primary star, with no clear signs of orbital curvature. Spectra of SpeX/IRTF observed T dwarfs were compared to the combined spectrum of GJ 758 B, with χ {sup 2} minimization suggesting a best fit for spectral type T7.0 ± 1.0, but with a shallow minimum over T5–T8. Fitting of synthetic spectra from the BT-Settl13 model atmospheres gives an effective temperature T {sub eff} = 741 ± 25 K and surface gravity logg=4.3±0.5 dex (cgs). Our derived best-fit spectral type and effective temperature from modeling of the low-resolution spectrum suggest a slightly earlier and hotter companion than previous findings from photometric data, but do not rule out current results, and confirm GJ 758 B as one of the coolest sub-stellar companions to a Sun-like star to date.

79 ASTRONOMY AND ASTROPHYSICS↗

The cool-star spectral catalog: A uniform collection of IUE SWP-LOs

Over the past decade and a half of its operations, the International Ultraviolet Explorer has recorded low-dispersion spectrograms in the 1150-2000 A interval of more than 800 stars of late spectral type (F-M). The sub-2000 A region contains a number of emission lines that are key diagnostics of physical conditions in the high-excitation chromospheres and subcoronal 'transition zones' of such stars. Many of the sources have been observed a number of times, and the available collection of SWP-LO exposures in the IUE Archives exceeds 4,000. With support from the Astrophysics Data Program, we have assembled the archival material into a catalog of IUE far-UV fluxes of late-type stars. In order to ensure uniform processing of the spectra, we: (1) photometrically corrected the raw vidicon images with a custom version of the 1985 SWP ITF; (2) identified and eliminated, sharp cosmic-ray 'hits' by means of a spatial filter; (3) extracted the spectral traces with the 'optimal' (weighted-slit) strategy; and (4) calibrated them against a well-characterized reference source, the DA white dwarf G191-B2B. Our approach is similar to that adopted by the IUE Project for its 'Final Archive', but our implementation is specialized to the case of chromospheric emission-line sources. We measured the resulting SWP-LO spectra using a semi-autonomous algorithm that establishes a smooth continuum by numerical filtering, and then fits the significant emissions (or absorptions) by means of a constrained Bevington-type multiple-Gaussian procedure. The algorithm assigns errors to the fitted fluxes - or upper limits in the absence of a significant detection - according to a model based on careful measurements of the noise properties of the IUE's intensified SEC cameras. Here, we describe the 'visualization' strategies we adopted to ensure human-review of the semi-autonomous processing and measuring algorithms; the derivation of the noise model and the assignment of errors; and the structure of the final catalog as delivered to the Astrophysics Data System.

Ayres, T.↗

How to COAAD Images. II. A Coaddition Image that is Optimal for Any Purpose in the Background-dominated Noise Limit

Image coaddition is one of the most basic operations that astronomers perform. In Paper I, we presented the optimal ways to coadd images in order to detect faint sources and to perform flux measurements under the assumption that the noise is approximately Gaussian. Here, we build on these results and derive from first principles a coaddition technique that is optimal for any hypothesis testing and measurement (e.g., source detection, flux or shape measurements, and star/galaxy separation), in the background-noise-dominated case. This method has several important properties. The pixels of the resulting coadded image are uncorrelated. This image preserves all the information (from the original individual images) on all spatial frequencies. Any hypothesis testing or measurement that can be done on all the individual images simultaneously, can be done on the coadded image without any loss of information. The PSF of this image is typically as narrow, or narrower than the PSF of the best image in the ensemble. Moreover, this image is practically indistinguishable from a regular single image, meaning that any code that measures any property on a regular astronomical image can be applied to it unchanged. In particular, the optimal source detection statistic derived in Paper I is reproduced by matched filtering this image with its own PSF. This coaddition process, which we call proper coaddition, can be understood as the maximum signal-to-noise ratio measurement of the Fourier transform of the image, weighted in such a way that the noise in the entire Fourier domain is of equal variance. This method has important implications for multi-epoch seeing-limited deep surveys, weak lensing galaxy shape measurements, and diffraction-limited imaging via speckle observations. The last topic will be covered in depth in future papers. We provide an implementation of this algorithm in MATLAB.

79 ASTRONOMY AND ASTROPHYSICS↗

Satellite and space probe telemetry.

Space modulation systems characteristics, considering data flow rate, spacecraft weight and power, antenna gain, noise figure, etc

SPACE COMMUNICATION↗

Terrestrial Water Mass Load Changes from Gravity Recovery and Climate Experiment (GRACE)

Recent studies show that data from the Gravity Recovery and Climate Experiment (GRACE) is promising for basin- to global-scale water cycle research. This study provides varied assessments of errors associated with GRACE water storage estimates. Thirteen monthly GRACE gravity solutions from August 2002 to December 2004 are examined, along with synthesized GRACE gravity fields for the same period that incorporate simulated errors. The synthetic GRACE fields are calculated using numerical climate models and GRACE internal error estimates. We consider the influence of measurement noise, spatial leakage error, and atmospheric and ocean dealiasing (AOD) model error as the major contributors to the error budget. Leakage error arises from the limited range of GRACE spherical harmonics not corrupted by noise. AOD model error is due to imperfect correction for atmosphere and ocean mass redistribution applied during GRACE processing. Four methods of forming water storage estimates from GRACE spherical harmonics (four different basin filters) are applied to both GRACE and synthetic data. Two basin filters use Gaussian smoothing, and the other two are dynamic basin filters which use knowledge of geographical locations where water storage variations are expected. Global maps of measurement noise, leakage error, and AOD model errors are estimated for each basin filter. Dynamic basin filters yield the smallest errors and highest signal-to-noise ratio. Within 12 selected basins, GRACE and synthetic data show similar amplitudes of water storage change. Using 53 river basins, covering most of Earth's land surface excluding Antarctica and Greenland, we document how error changes with basin size, latitude, and shape. Leakage error is most affected by basin size and latitude, and AOD model error is most dependent on basin latitude.

Seo, K.-W.↗

Near-Field Acoustic Power Level Analysis of F31/A31 Open Rotor Model at Simulated Cruise Conditions, Technical Report II

Near-field acoustic power level analysis of F31A31 open rotor model has been performed to determine its noise characteristics at simulated cruise flight conditions. The non-proprietary parts of the test data obtained from experiments in the 8x6 supersonic wind tunnel were provided by NASA-Glenn Research Center. The tone and broadband components of total noise have been separated from raw test data by using a new data analysis tool. Results in terms of sound pressure levels, acoustic power levels, and their variations with rotor speed, freestream Mach number, and input shaft power, with different blade-pitch setting angles at simulated cruise flight conditions, are presented and discussed. Empirical equations relating models acoustic power level and input shaft power have been developed. The near-field acoustic efficiency of the model at simulated cruise conditions is also determined. It is hoped that the results presented in this work will serve as a database for comparison and improvement of other open rotor blade designs and also for validating open rotor noise prediction codes.

Broadband↗

160-190 GHz Monolithic Low Noise Amplifiers

This paper presents the results of two 160-190 GHz monolithic low noise amplifiers (LNAs) fabricated with 0.07 meu pseudomorphic (PM) InAIAs/InGaAs/InP HEMT technology using a reactive ion etch (RIE) via hole process.

low↗

Low-noise cold-field emission current obtained between two opposed carbon cone nanotips during in situ transmission electron microscope biasing

A dedicated transmission electron microscope sample holder has been used to study in situ the cold-field emission process of carbon cone nanotips (CCnTs). We show that when using a CCnT instead of a Au plate-anode, the standard deviation of the emission current noise can be decreased from the 10 nA range to the 1 nA range under vacuum conditions of 10{sup −5 }Pa. This shows the strong influence of the anode on the cold-field emission current noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-D-210-03: Limited-View Multi-Source Quantitative Photoacoustic Tomography

Purpose: This work is to investigate a novel limited-view multi-source acquisition scheme for the direct and simultaneous reconstruction of optical coefficients in quantitative photoacoustic tomography (QPAT), which has potentially improved signal-to-noise ratio and reduced data acquisition time. Methods: Conventional QPAT is often considered in two steps: first to reconstruct the initial acoustic pressure from the full-view ultrasonic data after each optical illumination, and then to quantitatively reconstruct optical coefficients (e.g., absorption and scattering coefficients) from the initial acoustic pressure, using multi-source or multi-wavelength scheme.Based on a novel limited-view multi-source scheme here, We have to consider the direct reconstruction of optical coefficients from the ultrasonic data, since the initial acoustic pressure can no longer be reconstructed as an intermediate variable due to the incomplete acoustic data in the proposed limited-view scheme. In this work, based on a coupled photo-acoustic forward model combining diffusion approximation and wave equation, we develop a limited-memory Quasi-Newton method (LBFGS) for image reconstruction that utilizes the adjoint forward problem for fast computation of gradients. Furthermore, the tensor framelet sparsity is utilized to improve the image reconstruction which is solved by Alternative Direction Method of Multipliers (ADMM). Results: The simulation was performed on a modified Shepp-Logan phantom to validate the feasibility of the proposed limited-view scheme and its corresponding image reconstruction algorithms. Conclusion: A limited-view multi-source QPAT scheme is proposed, i.e., the partial-view acoustic data acquisition accompanying each optical illumination, and then the simultaneous rotations of both optical sources and ultrasonic detectors for next optical illumination. Moreover, LBFGS and ADMM algorithms are developed for the direct reconstruction of optical coefficients from the acoustic data. Jing Feng and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hyperspectral data analysis procedures with reduced sensitivity to noise

Multispectral sensor systems have become steadily improved over the years in their ability to deliver increased spectral detail. With the advent of hyperspectral sensors, including imaging spectrometers, this technology is in the process of taking a large leap forward, thus providing the possibility of enabling delivery of much more detailed information. However, this direction of development has drawn even more attention to the matter of noise and other deleterious effects in the data, because reducing the fundamental limitations of spectral detail on information collection raises the limitations presented by noise to even greater importance. Much current effort in remote sensing research is thus being devoted to adjusting the data to mitigate the effects of noise and other deleterious effects. A parallel approach to the problem is to look for analysis approaches and procedures which have reduced sensitivity to such effects. We discuss some of the fundamental principles which define analysis algorithm characteristics providing such reduced sensitivity. One such analysis procedure including an example analysis of a data set is described, illustrating this effect.

Landgrebe, David A.↗

Multioutput Convolutional Neural Network for Improved Parameter Extraction in Time-Resolved Electrostatic Force Microscopy Data

Time-resolved scanning probe microscopy methods, like time-resolved electrostatic force microscopy (trEFM), enable imaging of dynamic processes ranging from ion motion in batteries to electronic dynamics in microstructured thin film semiconductors for solar cells. Reconstructing the underlying physical dynamics from these techniques can be challenging due to the interplay of cantilever physics with the actual transient kinetics of interest in the resulting signal. Previously, quantitative trEFM used empirical calibration of the cantilever or feed-forward neural networks trained on simulated data to extract the physical dynamics of interest. Both these approaches are limited by interpreting the underlying signal as a single exponential function, which serves as an approximation but does not adequately reflect many realistic systems. Here, we present a multi-branched, multi-output convolutional neural network (CNN) that uses the trEFM signal in addition to the physical cantilever parameters as input. The trained CNN accurately extracts parameters describing both single-exponential and bi-exponential underlying functions, and more accurately reconstructs real experimental data in the presence of noise. This article demonstrates an application of physics-informed machine learning to complex signal processing tasks, enabling more efficient and accurate analysis of trEFM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantized Information in Spectral Cyberspace

The constant-Q Gabor atom is developed for spectral power, information, and uncertainty quantification from time–frequency representations. Stable multiresolution spectral entropy algorithms are constructed with continuous wavelet and Stockwell transforms. The recommended processing and scaling method will depend on the signature of interest, the desired information, and the acceptable levels of uncertainty of signal and noise features. Selected Lamb wave signatures and information spectra from the 2022 Tonga eruption are presented as representative case studies. Resilient transformations from physical to information metrics are provided for sensor-agnostic signal processing, pattern recognition, and machine learning applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

PROBING THE DARK AGES AT z ∼ 20: THE SCI-HI 21 cm ALL-SKY SPECTRUM EXPERIMENT

We present first results from the SCI-HI experiment, which we used to measure the all-sky-averaged 21 cm brightness temperature in the redshift range 14.8 < z < 22.7. The instrument consists of a single broadband sub-wavelength size antenna and a sampling system for real-time data processing and recording. Preliminary observations were completed in 2013 June at Isla Guadalupe, a Mexican biosphere reserve located in the Pacific Ocean. The data was cleaned to excise channels contaminated by radio frequency interference, and the system response was calibrated by comparing the measured brightness temperature to the Global Sky Model of the Galaxy and by independent measurement of Johnson noise from a calibration terminator. We present our results, discuss the cosmological implications, and describe plans for future work.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of a Decision-Directed Receiver with Unknown Priors

A decision-directed receiver (DDR) uses previous outputs (decisions) to estimate unknown parameters and, on the basis of these estimates, modifies the detector structure for subsequent decisions. Although the DDR is less complex to instrument than other adaptive schemes, inherent in the decision-directed approach is the possibility of a runaway. This occurs when the detector commits a sequence of decision errors resulting in a degradation of parameter estimates, which, in turn, results in a further deterioration of detector performance. Because of the dependencies introduced by the learning process, runaway is difficult to analyze. In this paper, a DDR with unknown a priori probabilities is considered. The priors are estimated by the relative frequency of decisions of that event. For binary detection, it is shown that there is a positive probability of a runaway (the estimates converge to 1 or 0), which equals 1 if the signal-to-noise ratio is below a critical value. A tight bound on the probability of a runaway is obtained by approximating the learning process by a random walk with independent increments. The analysis demonstrates that a runaway is quite improbable even for moderate signal-to-noise ratios. The analysis is extended to multiple signals and to the situation where the estimates of the priors are updated continuously through exponential weighting rather than allowed to converge.

Davisson, Lee D.↗

Navigating the Noise: Bringing Clarity to ML Parameterization Design With O $\boldsymbol{\mathcal{O}}$(100) Ensembles

Abstract Machine‐learning (ML) parameterizations of subgrid processes (here of turbulence, convection, and radiation) may one day replace conventional parameterizations by emulating high‐resolution physics without the cost of explicit simulation. However, uncertainty about the relationship between offline and online performance (i.e., when integrated with a large‐scale general circulation model) hinders their development. Much of this uncertainty stems from limited sampling of the noisy, emergent effects of upstream ML design decisions on downstream online hybrid simulation. Our work rectifies the sampling issue via the construction of a semi‐automated, end‐to‐end pipeline for size ensembles of hybrid simulations, revealing important nuances in how systematic reductions in offline error manifest in changes to online error and online stability. For example, removing dropout and switching from a Mean Squared Error to a Mean Absolute Error loss both reduce offline error, but they have opposite effects on online error and online stability. Other design decisions, like incorporating memory, converting moisture input from specific humidity to relative humidity, using batch normalization, and training on multiple climates do not come with any such compromises. Finally, we show that ensemble sizes of may be necessary to reliably detect causally relevant differences online. By enabling rapid online experimentation at scale, we can empirically settle debates regarding subgrid ML parameterization design that would have otherwise remained unresolved in the noise.

Lin, Jerry [Department of Earth System Sciences Un↗

Synthetic Tracking on a Small Telescope

Synthetic tracking uses high speed (up to 10 Hz) low noise (<2e-) large format sensors ~16 Mpix along with a multi-vector shift/add algorithm that coadds multiple image frames to increase the signal to noise ratio (SNR) needed to detect (if present) multiple moving objects in the field of view (FOV). We published the application of synthetic tracking to look for asteroids in 2014 (Shao 2014), but recently have applied it more as well to Earth orbiting objects. We have begun testing the data processing graphical processing unit (GPU) array with a small telescope, a 28 cm Celestron RASA telescope and a low cost low noise 16 Mpix CMOS camera at a dark site in California. This system is now operational with a 2 sqdeg FOV and a limiting magnitude between ~16-17.5 stellar magnitudes (mag) depending on a number of observational parameters for short integration times. The instrument can be used to search for NEOs, where we use much longer integration times to get sensitivity ~ 20.5 mag (at new moon). Synthetic tracking provides significant improvements in both sensitivity and astrometric accuracy.

Turyshev, Slava G.↗

Denoising of polychromatic CT images based on their own noise properties

Purpose: Because of high diagnostic accuracy and fast scan time, computed tomography (CT) has been widely used in various clinical applications. Since the CT scan introduces radiation exposure to patients, however, dose reduction has recently been recognized as an important issue in CT imaging. However, low-dose CT causes an increase of noise in the image and thereby deteriorates the accuracy of diagnosis. In this paper, the authors develop an efficient denoising algorithm for low-dose CT images obtained using a polychromatic x-ray source. The algorithm is based on two steps: (i) estimation of space variant noise statistics, which are uniquely determined according to the system geometry and scanned object, and (ii) subsequent novel conversion of the estimated noise to Gaussian noise so that an existing high performance Gaussian noise filtering algorithm can be directly applied to CT images with non-Gaussian noise. Methods: For efficient polychromatic CT image denoising, the authors first reconstruct an image with the iterative maximum-likelihood polychromatic algorithm for CT to alleviate the beam-hardening problem. We then estimate the space-variant noise variance distribution on the image domain. Since there are many high performance denoising algorithms available for the Gaussian noise, image denoising can become much more efficient if they can be used. Hence, the authors propose a novel conversion scheme to transform the estimated space-variant noise to near Gaussian noise. In the suggested scheme, the authors first convert the image so that its mean and variance can have a linear relationship, and then produce a Gaussian image via variance stabilizing transform. The authors then apply a block matching 4D algorithm that is optimized for noise reduction of the Gaussian image, and reconvert the result to obtain a final denoised image. To examine the performance of the proposed method, an XCAT phantom simulation and a physical phantom experiment were conducted. Results: Both simulation and experimental results show that, unlike the existing denoising algorithms, the proposed algorithm can effectively reduce the noise over the whole region of CT images while preventing degradation of image resolution. Conclusions: To effectively denoise polychromatic low-dose CT images, a novel denoising algorithm is proposed. Because this algorithm is based on the noise statistics of a reconstructed polychromatic CT image, the spatially varying noise on the image is effectively reduced so that the denoised image will have homogeneous quality over the image domain. Through a simulation and a real experiment, it is verified that the proposed algorithm can deliver considerably better performance compared to the existing denoising algorithms.

60 APPLIED LIFE SCIENCES↗