Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Microstructure, Mechanical Properties and Residual Stress of Selective Laser Melted AlSi10Mg

AlSi10Mg processed by selective laser melting (SLM) is common in various industries because of its complex structure and high performance. The microstructure, residual stress and mechanical properties restrict its application, while they are affected by the scanning path type and preheating temperature. In this work, to investigate the properties of selective laser melted AlSi10Mg alloys and gain better performance results, the microstructure and mechanical tests are performed at several preheating temperatures based on the uniformity and chessboard scanning strategy. It is found that the selective laser melted AlSi10Mg parts fabricated in the chessboard scanning path have better mechanical properties than those fabricated in the uniformity scanning path. Furthermore, a higher preheating temperature can induce less residual stress due to the enhanced Al crystal faces. Finally, analyses of the microstructures, mechanical and residual stress provide a valuable suggestion that the combination of the range of preheating temperature and the scanning path can improve the performance of selective laser melted AlSi10Mg.

36 MATERIALS SCIENCE↗

Deploy Nalu/Kokkos algorithmic infrastructure with performance benchmarking.

The former Nalu interior heterogeneous algorithm design, which was originally designed to manage matrix assembly operations over all elemental topology types, has been modified to operate over homogeneous collections of mesh entities. This newly templated kernel design allows for removal of workset variable resize operations that were formerly required at each loop over a Sierra ToolKit (STK) bucket (nominally, 512 entities in size). Extensive usage of the Standard Template Library (STL) std::vector has been removed in favor of intrinsic Kokkos memory views. In this milestone effort, the transition to Kokkos as the underlying infrastructure to support performance and portability on many-core architectures has been deployed for key matrix algorithmic kernels. A unit-test driven design effort has developed a homogeneous entity algorithm that employs a team-based thread parallelism construct. The STK Single Instruction Multiple Data (SIMD) infrastructure is used to interleave data for improved vectorization. The collective algorithm design, which allows for concurrent threading and SIMD management, has been deployed for the core low-Mach element- based algorithm. Several tests to ascertain SIMD performance on Intel KNL and Haswell architectures have been carried out. The performance test matrix includes evaluation of both low- and higher-order methods. The higher-order low-Mach methodology builds on polynomial promotion of the core low-order control volume nite element method (CVFEM). Performance testing of the Kokkos-view/SIMD design indicates low-order matrix assembly kernel speed-up ranging between two and four times depending on mesh loading and node count. Better speedups are observed for higher-order meshes (currently only P=2 has been tested) especially on KNL. The increased workload per element on higher-order meshes bene ts from the wide SIMD width on KNL machines. Combining multiple threads with SIMD on KNL achieves a 4.6x speedup over the baseline, with assembly timings faster than that observed on Haswell architecture. The computational workload of higher-order meshes, therefore, seems ideally suited for the many-core architecture and justi es further exploration of higher-order on NGP platforms. A Trilinos/Tpetra-based multi-threaded GMRES preconditioned by symmetric Gauss Seidel (SGS) represents the core solver infrastructure for the low-Mach advection/diffusion implicit solves. The threaded solver stack has been tested on small problems on NREL's Peregrine system using the newly developed and deployed Kokkos-view/SIMD kernels. fforts are underway to deploy the Tpetra-based solver stack on NERSC Cori system to benchmark its performance at scale on KNL machines.

97 MATHEMATICS AND COMPUTING↗

GeoMelt{sup R} ICV{sup TM} Treatment of Sellafield Pond Solids Waste - 13414

Kurion, Inc., in partnership with AMEC Ltd., is demonstrating its GeoMelt{sup R} In-Container Vitrification (ICV){sup TM} Technology to Sellafield Ltd. (SL). SL is evaluating the proposition of directly converting a container (skip/box/drum) of raw solid ILW into an immobilized waste form using thermal treatment, such that the resulting product is suitable for interim storage at Sellafield and subsequent disposal at a future Geological Disposal Facility. Potential SL feed streams include sludges, ion-exchange media, sand, plutonium contaminated material, concrete, uranium, fuel cladding, soils, metals, and decommissioning wastes. The solid wastes have significant proportions of metallic constituents in the form of containers, plant equipment, structural material and swarf arising from the nuclear operations at Sellafield. GeoMelt's proprietary ICV process was selected for demonstration, with the focus being high and reactive metal wastes arising from solid ILW material. A composite surrogate recipe was used to demonstrate the technology towards treating waste forms of diverse types and shapes, as well as those considered difficult to process; all the while requiring few (if any) pre-treatment activities. Key strategic objectives, along with their success criterion, were established by SL for this testing, namely: 1. Passivate and stabilize the raw waste simulant, as demonstrated by the entire quantity of material being vitrified, 2. Immobilize the radiological and chemo-toxic species, as demonstrated via indicative mass balance using elemental analyses from an array of samples, 3. Production of an inert and durable product as evidenced by transformation of reactive metals to their inert oxide forms and satisfactory leachability results using PCT testing. Two tests were performed using the GeoMelt Demonstration Unit located at AMEC's Birchwood Park Facilities in the UK. Post-melt examination of the first test indicated some of the waste simulant had not fully processed, due to insufficient processing time and melt temperature. A second test, incorporating operational experience from the first test, was performed and resulted in all of the 138 kg of feed material being treated. The waste simulant portion, at 41 kg, constituted 30 wt% of the total feed mass, with over 90% of this being made up of various reactive and non-reactive metals. The 95 liters of staged material was volume reduced to 41 liters, providing a 57% overall feed to product volume reduction in a fully passivated two-phase glass/metal product. The GeoMelt equipment operated as designed, vitrifying the entire batch of waste simulant. Post-melt analytical testing verified that 91-99+% of the radiological tracer metals were uniformly distributed within the glass/cast refractory/metal product, and the remaining fraction was captured in the offgas filtration systems. PCT testing of the glass and inner refractory liner showed leachability results that outperform the DOE regulatory limit of 2 g/m{sup 2} for the radiological species of interest (Sr, Ru, Cs, Eu, Re), and by more than an order of magnitude better for standard reference analytes (B, Na, Si). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 1c Raw Data

Intermittent chronoamperometry (CA) testing was performed on Si/GaN photocathode in hourly manner. The LSV scan at 0 hour, 1 hour CA, 2 hours CA, 3 hours CA, 4 hours CA, 6 hours CA, 8 hours CA and 10 hours CA were recorded to track the changes of the photoelectrochemica (PEC) performance of the photocathode. The scan range was set to be 0V vs open circuit voltage (Eoc) to -0.7V vs RHE. Test was performed under one sun illumination in 0.5M H2SO4 (pH=0.4).

photocathode↗

A Qualitative Investigation of Deposition Velocities of a Non-Newtonian Slurry in Complex Pipeline Geometries

The External Flowsheet Review Team (EFRT) has identified the issues relating to the Waste Treatment and Immobilization Plant (WTP) pipe plugging. Per the review’s executive summary, “Piping that transports slurries will plug unless it is properly designed to minimize this risk. This design approach has not been followed consistently, which will lead to frequent shutdowns due to line plugging.” To evaluate the potential for plugging, testing was performed to determine critical velocities for the complex WTP piping layout. Critical velocity is defined as the point at which a moving bed of particles begins to form on the pipe bottom during slurry-transport operations. Pressure drops across the fittings of the test pipeline were measured with differential pressure transducers, from which the critical velocities were determined. A WTP prototype flush system was installed and tested upon the completion of the pressure-drop measurements. We also provide the data for the overflow relief system represented by a WTP complex piping geometry with a non-Newtonian slurry. A waste simulant composed of alumina (nominally 50 μm in diameter) suspended in a kaolin clay slurry was used for this testing. The target composition of the simulant was 10 vol% alumina in a suspending medium with a yield stress of 3 Pa. No publications or reports are available to confirm the critical velocities for the complex geometry evaluated in this testing; therefore, for this assessment, the results were compared to those reported by Poloski et al. (2008) for which testing was performed for a straight horizontal pipe. The results of the flush test are compared to the WTP design guide 24590-WTP-GPG-M-0058, Rev. 0 (Hall 2006) in an effort to confirm flushing-velocity requirements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Active Climate Control Seats on Energy Use, Fuel Use, and CO2 Emissions

A project was developed through collaboration between Gentherm and NREL to determine the impact of climate control seats for light-duty vehicles in the United States. The project used a combination of experimentation and analysis, with experimental results providing critical input to the analysis process. First, outdoor stationary vehicle testing was performed at NREL's facility in Golden, CO using multiple occupants. Two pre-production Ford Focus electric vehicles were used for testing; one containing a standard inactive seat and the second vehicle containing a Gentherm climate control seat. Multiple maximum cool-down and steady-state cooling tests were performed in late summer conditions. The two vehicles were used to determine the increase in cabin temperature when using the climate control seat in comparison to the baseline vehicle cabin temperature with a standard seat at the equivalent occupant whole-body sensation. The experiments estimated that on average, the climate control seats allowed for a 2.61 degrees Celsius increase in vehicle cabin temperature at equivalent occupant body sensation compared to the baseline vehicle. The increased cabin air temperature along with their measured energy usage were then used as inputs to the national analysis process. The national analysis process was constructed from full vehicle cabin, HVAC, and propulsion models previously developed by NREL. In addition, three representative vehicle platforms, vehicle usage patterns, and vehicle registration weighted environmental data were integrated into the analysis process. Both the baseline vehicle and the vehicle with climate control seats were simulated, using the experimentally determined cabin temperature offset of 2.61degrees Celsius and added seat energy as inputs to the climate control seat vehicle model. The U.S. composite annual fuel use savings for the climate control seats over the baseline A/C system was determined to be 5.1 gallons of gasoline per year per vehicle, corresponding to 4.0 grams of CO2/mile savings. Finally, the potential impact of 100 percent adoption of climate control seats on U.S. light-duty fleet A/C fuel use was calculated to be 1.3 billion gallons of gasoline annually with a corresponding CO2 emissions reduction of 12.7 million tons. Direct comparison of the impact of the CCS to the ventilated seat off-cycle credit was not possible because the NREL analysis calculated a combined car/truck savings and the baseline A/C CO2 emissions were higher than EPA. To enable comparison, the CCS national A/C CO2 emissions were split into car/truck components and the ventilated seat credit was scaled up. The split CO2 emissions savings due to the CCS were 3.5 g/mi for a car and 4.4 g/mi for a truck. The CCS saved an additional 2.0 g/mi and 2.5 g/mi over the adjusted ventilated seat credit for a car and truck, respectively.

30 DIRECT ENERGY CONVERSION↗

300 Area VOC Program Slug Test Characterization Results for Selected Test/Depth Intervals for Wells 399-2-5, 399-3-22, and 399-4-14

Multiple, stress-level slug tests were performed at selected test/depth intervals within wells 399-2-5, 399-3-22, and 399-4-14 as part of the 300 Area volatile organic compound characterization program at the Hanford Site in Washington State. The temporary test screen lengths were characterized as the boreholes were advanced to their final drill depths and before their completion as monitor-well facilities. Following well completion, slug tests were performed in the final, completed well-screen sections. The objectives of the slug tests were to provide the vertical distribution of hydraulic conductivity with depth at these locations and to support selection of the final well screen-depth interval for each of these monitor-well facilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal conductance measurements of bolted copper joints for SuperCDMS

Joint thermal conductance testing has been undertaken for bolted copper to copper connections from 60 mK to 26 K. This testing was performed to validate an initial design basis for the SuperCDMS experiment, where a dilution refrigerator will be coupled to a cryostat via multiple bolted connections. Copper used during testing was either gold plated or passivated with citric acid to prevent surface oxidation. Results obtained are well fit by a power law regression of joint thermal conductance to temperature and match well with data collected during a literature review.

Schmitt, R.↗

Acceptance Test Report IdentiFinder 2 Serial Number 910532-78 (14 May 2014)

This report documents the initial testing of the subject IdentiFinder 2. The testing was performed by Philip Hypes, Scientist 3, at technical area 35 of Los Alamos National Laboratory on 14 May 2014. It appeared that these tests constituted the first use of the instrument, as the software asked for verification of the date/time immediately after the instrument was turned on. Except for the final self-calibration (noted below), all of the testing was performed with the instrument attached to AC power, as the battery was not charged.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acceptance Test Report IdentiFinder 2 Serial Number 910532-77 (14 May 2014)

This report documents the initial testing of the subject IdentiFinder 2. The testing was performed by Philip Hypes, Scientist 3, at technical area 35 of Los Alamos National Laboratory on 14 May 2014. It appeared that these tests constituted the first use of the instrument, as the software asked for verification of the date/time immediately after the instrument was turned on. Except for the final self-calibration (noted below), all of the testing was performed with the instrument attached to AC power, as the battery was not charged.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-100: Designing a QA Tool for Enhance Dynamic Wedges Based On Dynalog Files

Purpose: A robust quality assurance (QA) program for computer controlled enhanced dynamic wedge (EDW) has been designed and tested. Calculations to perform such QA test is based upon the EDW dynamic log files generated during dose delivery. Methods: Varian record and verify system generates dynamic log (dynalog) files during dynamic dose delivery. The system generated dynalog files contain information such as date and time of treatment, energy, monitor units, wedge orientation, and type of treatment. It also contains the expected calculated segmented treatment tables (STT) and the actual delivered STT for the treatment delivery as a verification record. These files can be used to assess the integrity and precision of the treatment plan delivery. The plans were delivered with a 6 MV beam from a Varian linear accelerator. For available EDW angles (10°, 15°, 20°, 25°, 30°, 45°, and 60°) Varian STT values were used to manually calculate monitor units for each segment. It can also be used to calculate the EDW factors. Independent verification of fractional MUs per segment was performed against those generated from dynalog files. The EDW factors used to calculate MUs in TPS were dosimetrically verified in solid water phantom with semiflex chamber on central axis. Results: EDW factors were generated from the STT provided by Varian and verified against practical measurements. The measurements were in agreement of the order of 1 % to the calculated EDW data. Variation between the MUs per segment obtained from dynalog files and those manually calculated was found to be less than 2%. Conclusion: An efficient and easy tool to perform routine QA procedure of EDW is suggested. The method can be easily implemented in any institution without a need for expensive QA equipment. An error of the order of ≥2% can be easily detected.

60 APPLIED LIFE SCIENCES↗

The Optics of Deterrence: How Science Assures the Nuclear Stockpile's Reliability In Lieu of Testing

When designing a product intended to perform a certain function and satisfy some set of criteria, the standard engineering method to assess its ability to perform is to test it. This nearly universal concept works consistently, assuring proper function and generally avoiding or mitigating the consequence of failure to within acceptable limits. What would happen if the product developers were told that they must continue to certify and validate the performance without testing it, that the landscape in which the product must serve its purpose is constantly evolving, and that the product in question is the United States’ nuclear weapons stockpile? This is the position the National Nuclear Security Administration (NNSA) finds itself in; the reliability of the stockpile must be verified without actually testing it to see if it works as intended.

43 PARTICLE ACCELERATORS↗

CoDCon Project (Final Report)

The co-decontamination (CoDCon) project was established in FY 2016 with the objectives of (a) evaluating the uncertainty in the uranium (U)/plutonium (Pu) ratio in a mixed U/Pu product from a tributyl phosphate (TBP)–based solvent extraction flowsheet, and (b) developing and demonstrating on-line optical spectroscopy for real-time monitoring of key components (e.g., Pu, U, and HNO 3 concentrations) in the process solutions. We were interested in assessing the accuracy and precision to which a specific uranium-to-plutonium (U/Pu) ratio can be achieved, which for the purposes of this project was set at a U/Pu mass ratio of 7/3. The uncertainty associated with achieving this specific target U/Pu ratio was investigated during five flowsheet tests using laboratory-scale solvent extraction equipment. In addition, optical spectroscopic techniques were incorporated into the CoDCon solvent extraction testing system, allowing real time monitoring of all input and output process streams. Two CoDCon flowsheet tests were performed in FY 2018 using a simple dissolved fuel simulant containing only U (~1 M) and Pu (~15 mM) in nitric acid (HNO 3 ; ~3 M). In FY 2019, two additional flowsheet tests were performed. For the first of these (CoDCon Run 3), the dissolved fuel simulant was similar to that used in the first two tests, with the inclusion of 1 mM neptunium (Np). The second test conducted in FY 2019 (CoDCon Run 4) used a more representative dissolved fuel simulant, including addition of non-radioactive fission product elements. A fifth CoDCon flowsheet test (CoDCon Run 5) was conducted in FY 2020, with the following additional objectives: (1) routing of the technetium (Tc) in the simulated dissolved fuel solution to the solvent extraction raffinate, and (2) routing of the Np in the simulated dissolved fuel solution to the U/Pu product. All tests used a bank of sixteen 2 cm centrifugal contactors. The tests involved first loading the solvent (30 vol% TBP dissolved in n-dodecane) with U and Pu (and Np, for Run 5), then the Pu (and Np) was stripped from the loaded solvent with a U(IV) solution (~50 mM) and the flowsheet conditions were adjusted such that some U partitioned into the Pu-containing product stream. The amount of U accompanying the Pu was monitored in real time using optical spectroscopic techniques coupled with chemometric modeling. Based on the real-time spectroscopic measurement of the U/Pu ratio, adjustments were made to the flowrate of the fresh TBP solvent phase used to scrub U from the aqueous Pu-containing product. This proved to be a very effective way to control the U/Pu mass ratio in the product. This report presents the results of the CoDCon Run 5 test. The flowsheet tested in Run 5 was substantially different than that run in the prior tests, especially the solvent loading section of the flowsheet. Two key changes were made. First, based on the objective to extract all the Np and route it with the U/Pu product, pentavalent vanadium [V(V)] was added to the feed and scrub solutions. The purpose of the V(V) was to convert all the Np to the +6 oxidation state, which is extractable by TBP. Second, a high acid (8 M HNO 3 ) scrub was added to the flowsheet to scrub the Tc from the solvent. This was followed by a low acid scrub (0.05 M HNO 3 ) to reduce the residual HNO 3 concentration in the solvent prior to the Pu stripping step. The output from the low acid scrub was collected separately, rather than routing towards the raffinate. The modifications to the solvent loading part of the flowsheet were only partially successful. The treatment with V(V) was effective at converting the Np to Np(VI). Only 1.3% of the Np remained in the raffinate solution. However, ~40% of the Np stripped out of the solvent in the low acid scrub step; nearly 20% of the Pu also was stripped from the solvent during the low acid scrub. For further development, either modifications to the flowsheet, or concentration and recycle of the low acid stream into the

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental and Computational Studies of Stress Corrosion Cracking of Alloys 308/309 and 82/182 Weldments in Corrosive and Radiation Environment

The goal of the project was to determine factors that influence SCC and IASCC in weldments found in LWR nuclear power plants. We focused on a SA508-304L SS weldment fabricated by EPRI using gas tungsten arc welding and used an aggressive BWR normal water chemistry (NWC) immersion environment. This weldment used 309L butter and 308L groove filler material. The microstructure of the 309L butter was non-uniform, exhibiting a 20–30μm thick martensitic layer closest to the SA508 interface, a 1–4 mm thick single γ austenite phase dilution zone, and a γ–δ duplex region extending to the 308L groove filler. The 308L groove filler had an entirely γ–δ duplex microstructure. Two approximately 1-inch thick 304L and SA508 plates approximately 12 by 6 square inches were joined using standard nuclear grade welding techniques. This included a post weld heat treatment of the 309L butter after application, a 0.32 cm fit-up root opening, and 57 bead lines of 308L groove filler applied in 18 layers. A 60 degree weld bevel angle was used and the 309L butter was 1.5 cm thick. Displacement cascade damage was induced using proton irradiation at the Michigan Ion Beam Laboratory. The incident proton energy was 2 MeV, the sample temperature was 360 ºC, and the calculated dpa value at 10 μm (60% of the Bragg peak depth of ~18 μm) was 5 dpa using the quick Kinchin-Pease model. Proton irradiation to this damage level required approximately 125 hours of beam time. Two types of samples were irradiated, tensile specimens and TEM bars. Samples were selected from all regions of the weldment, including the SA508-309L butter interface, the 309L-308L interface, and 308L-304L interface. The stainless steel alloys (304L, 308L, and 309L) within the heat affected zone are characterized by a duplex skeletal morphology of δ-ferrite and γ-austenite resulting from the recrystallization associated with weld fabrication. Approximately 7 to 8 mm of length along the specimen was irradiated. The gauge volume surfaces were mechanically polished and then electro-polished to remove mechanical damage from the mechanical polishing step prior to irradiation. Immersion tests were performed in a recirculating autoclave under BWR NWC conditions (2000 ppb wt. dissolved oxygen, neutral pH, 288 ºC, 10 MPa, and inlet water conductivity <100 nS/cm) to accelerate corrosion. Constant strain rate tests were performed either to failure or to approximately 5% strain. Strain rates of 10 -7 to 10 -6 mm/mm/s were used and typical immersion testing required four to six weeks to achieve failure or strains near 5%. Analysis primarily used advanced electron microscopy techniques of FIB lift out specimens.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development, feasibility, and uncertainty of radioactive 22 Na tracer dilution and gamma spectroscopy for mass determination of molten salt for pyroprocessing spent nuclear fuels

Accurate knowledge of the total mass of molten salts both for pyroprocessing spent nuclear fuels and for molten salt reactors is necessary for safeguards purposes. However, it is challenging to know or measure the total mass of molten salt due to the complicated shapes as well as the compositional—and thus density—changes that occur over time during operation. Here, we investigated radioactive tracer dilution (RTD) as a potential safeguards technique for application to the total mass measurement of LiCl–KCl–UCl 3 salt used for uranium electrorefining, with a focus on the feasibility, uncertainty, and fission product effect of RTD for salt mass measurement. To this end, experimental-scale RTD tests (600–700 g of total mass) were initially carried out by adding 22 Na tracer salt into LiCl–KCl salt containing 0, 5, and 28wt% radioactive salts from an electrorefiner (ER) for refining uranium. Upon the completion of the experimental-scale RTD tests, we performed a scale-up RTD test by directly adding 22 Na tracer salts to the ER, which uses about 12 kg of LiCl–KCl–UCl 3 salt during normal operation. This paper reports the main features of RTD for total mass measurement of molten salt and summarizes the results of the experimental-scale and scale-up RTD tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Influence of Process-Induced Anisotropy and Synovial Environment on Wear of EBM Built Ti6Al4V Joint Implants

Additive manufacturing (AM) technology is identified as an ideal solution to overcome challenges in design and manufacturing of complex components. However, the layered fashion of AM process result in directionally solidified microstructures on the system. The anisotropic surface texture will affect wear and corrosion resistance. The current study investigates tribological responses of AM-made Ti6Al4V for joint implant applications during the combined effect from synovial lubrication and process-induced surface structure on surface fatigue damage response. Electron beam melting was used to produce Ti6Al4V specimens and mechanical characterizations were performed using nanoindentation and micro bending tests to determine their mechanical properties. A series of pin-on-disk wear tests were performed to quantify sliding contact fatigue damage in three simulated synovial fluids with variable concentrations of bovine serum albumin and hyaluronic acid in the PBS solution. Physical properties of simulated synovial fluids were measured using a nanoindenter-based technique and correlated to fatigue wear response. The lower wear rate is found in greater protein concentrations. The results presented AM build direction significantly affects sliding fatigue wear resistance on TI6Al4V surface in all synovial environments.

36 MATERIALS SCIENCE↗

A computationally-efficient method for flamelet calculations

A new open-source code for the simulation of the diffusion flamelet equations is proposed. Emphasis is placed on using an approximate Jacobian to reduce the computational cost of the matrix operations. Performance of the proposed solvers is tested by performing flamelet calculations with kinetic mechanisms of varying sizes. For the unity Lewis number equations, the present iterative Newton solver using an approximate Jacobian greatly outperforms direct Newton solvers using exact Jacobians. The computation cost scales linearly with the number of species, leading to a reduction in solution times by two orders of magnitude for mechanisms containing thousands of species. The applicability of the Jacobian approximations to the solution of the non-unity Lewis number flamelet equations is assessed. The approximations are generally inadequate to solve the full non-unity Lewis number equations but can be used in some applications depending on the balance of terms in the flamelet equations. As an example, the flamelet solver is applied to the study of sooting tendencies in laminar co-flow diffusion flames where modified non-unity Lewis number flamelet equations, previously shown to accurately reproduce experimentally-measured Yield Sooting Indices (YSI), are solved. Here, the accelerated flamelet solver is well suited for sensitivity analysis and uncertainty quantification with large detailed kinetic mechanisms, tasks for which the computational cost was previously prohibitive.

42 ENGINEERING↗