Search for Magnetic Monopole Pair Production in Ultraperipheral Pb + Pb Collisions at s NN = 5.36 TeV with the ATLAS Detector at the LHC

This Letter presents a search for highly ionizing magnetic monopoles in 262 μ b − 1 of ultraperipheral Pb + Pb collision data at s NN = 5.36 TeV collected by the ATLAS detector at the LHC. A new methodology that exploits the properties of clusters of hits reconstructed in the innermost silicon detector layers is introduced to study highly ionizing particles in heavy-ion data. No significant excess above the background, which is estimated using a data-driven technique, is observed. Using a nonperturbative semiclassical model, upper limits at 95% confidence level are set on the cross section for pair production of monopoles with a single Dirac magnetic charge in the mass range of 20–150 GeV. Depending on the model, monopoles with a single Dirac magnetic charge and mass below 80–120 GeV are excluded. © 2025 CERN, for the ATLAS Collaboration 2025 CERN

Aad, G. (ORCID:0000000266654934)↗

Direct measurement of Stokes–Einstein diffusion of Cowpea mosaic virus with 19 µs-resolved XPCS

Brownian motion of Cowpea mosaic virus (CPMV) in water was measured using small-angle X-ray photon correlation spectroscopy (SA-XPCS) at 19.2 µs time resolution. It was found that the decorrelation time τ(Q) = 1/DQ 2 up to Q = 0.091 nm -1 . The hydrodynamic radius R H determined from XPCS using Stokes–Einstein diffusion D = kT/(6πηR H ) is 43% larger than the geometric radius R 0 determined from SAXS in the 0.007 M K 3 PO 4 buffer solution, whereas it is 80% larger for CPMV in 0.5 M NaCl and 104% larger in 0.5 M (NH 4 ) 2 SO 4 , a possible effect of aggregation as well as slight variation of the structures of the capsid resulting from the salt–protein interactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Yield of Thermo Scientific P385 D-T Neutron Generator vs . Current and Voltage

The Thermo Scientific P385 Neutron Generator is a compact neutron source, producing 14 MeV neutrons through the deuterium-tritium (DT) fusion reaction. It is important to measure and understand the dependence of the neutron production rate on the accelerator current and voltage. In this study we evaluated neutron production with an absolutely calibrated liquid scintillator neutron spectrometer (BTI N-Probe), an absolutely calibrated He-3 detector surrounded by HDPE shells (Detec Nested Neutron Spectrometer, NNS), and two uncalibrated ZnS fast neutron scintillators (EJ-410), for both A3082 and A3083 sealed tubes. Here we also modeled the neutron yield using the TRIM code, which calculates the trajectory and the energy loss of deuterons and tritons within the target. Experimental results showed an essentially linear dependence on beam current, as expected. A 3.59 ±0.08 power law dependence on the operating voltage was measured, in effective agreement with the modeled value of 3.5. A series of absolute NNS and N-Probe measurements, matched against MCNP calculations, showed that the A3083 and A3082 tubes provide a maximum neutron yield of 8.2 × 10 8 n/s and 4.7 × 10 8 n/s respectively, with estimated uncertainty of ±10%.We showed, through modeling, that tritium decay is not a significant consideration for tubes, such as these, with lifetimes of less than 10 years.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of $K_S^0$ and $\Lambda^0$ production in $t \bar{t}$ dileptonic events in pp collisions at $\sqrt{s} =$ 7 TeV with the ATLAS detector

Measurements of $K_S^0$ and Λ 0 production in $t\bar{t}$ final states have been performed. They are based on a data sample with integrated luminosity of 4.6 fb -1 from proton–proton collisions at a centre-of-mass energy of 7 TeV, collected in 2011 with the ATLAS detector at the Large Hadron Collider. Neutral strange particles are separated into three classes, depending on whether they are contained in a jet, with or without a $b$-tag, or not associated with a selected jet. The aim is to look for differences in their main kinematic distributions. A comparison of data with several Monte Carlo simulations using different hadronisation and fragmentation schemes, colour reconnection models and different tunes for the underlying event has been made. The production of neutral strange particles in $t \bar{t}$ dileptonic events is found to be well described by current Monte Carlo models for $K_S^0$ and Λ 0 production within jets, but not for those produced outside jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Next-Event Estimators Kinematics (Rev.2)

This paper reviews the kinematics of neutron elastic and inelastic scattering with moving and stationary targets for contributions to Neutron Next-Event Estimators (NEEs). NEEs are often used for simulating the response of detectors in locations that have few random walk particles. Contributions to NEEs from collisions differ from sampling the outgoing particle state in standard random walk collisions as the location of the estimator is fixed, thus fixing the scattering angle between the incoming and outgoing directions. To calculate contributions to NEEs, the outgoing energies and probabilities of scatter toward the estimator must be calculated. This paper presents the most general case that encompasses elastic and inelastic scattering with both moving and stationary targets. The moving target case is required for elastic scattering with thermal motion due to the free gas thermal treatment approximation. The stationary target equations are presented for comparison with equations presented in canonical Monte Carlo texts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Jefferson Lab Eta Factory Experiment and Applications of PbWO4 Calorimeters in Future Experimental Facilities

The goal of the new JLab Eta Factory (JEF) experiment, conducted with the GlueX detector in Hall D at Jefferson Lab, is to perform measurements of various ¿(') decays with a primary focus on rare neutral modes. The experiment’s physics program ranges from precision tests of low-energy QCD to searches for gauge bosons with masses below 1 GeV that could couple the Standard Model (SM) sector to the dark sector. The experiment will collect a high-statistics data sample of ¿(') mesons produced via a beam of tagged photons. The GlueX detector features a large, nearly uniform acceptance for both neutral and charged particles, enabling efficient identification of complex multi-particle final states. To meet the requirements of the JEF experiment, the inner section of the forward lead-glass calorimeter in the GlueX detector has been upgraded with lead tungstate (PbWO4) scintillating crystals. PbWO4 offers exceptional characteristics, such as a small radiation length and Molire radius, and large light yield, that make it ideal for constructing high- granularity, high-resolution, radiation-hard detectors. These properties enable excellent spatial separation and energy resolution of reconstructed electromagnetic showers, establishing PbWO4 as the material of choice for many high-precision experiments. The JEF experiment began data collection in April 2025 and will operate concurrently with the GlueX experiment, whose primary objective is the search for gluonic excitations in the meson spectrum. I will give an overview of the JEF experiment, the GlueX detector, and the feasibility of further upgrades to support future ¿ physics studies. Special attention will be given to the newly constructed PbWO4 scintillating calorimeter and recent advancements in calorimeter instrumentation.

Somov, Alexander↗

The diffuse X-ray spectrum from 14-200 keV as measured on OSO-5

The measurement of energy spectrum of the diffuse component of cosmic X-ray flux made on the OSO-5 spacecraft is described. The contributions to the total counting rate of the actively shielded X-ray detector are considered in some detail and the techniques used to eliminate the non-cosmic components are described. Positive values for the cosmic flux are obtained in seven energy channels between 14 and 200 keV and two upper limits are obtained between 200 and 254 keV. The results can be fitted by a power law spectrum. A critical comparison is made with the OSO-3 results. Conclusions show that the reported break in the energy spectrum at 40 keV is probably produced by an erroneous correction for the radioactivity induced in the detector on each passage through the intense charged particle fluxes in the South Atlantic anomaly.

Dennis, B. R.↗

Summary of the CTS Transient Event Counter data after one year of operation

The environmental charging of satellite surfaces during geomagnetic substorms is the apparent cause of a significant number of anomalous events occurring on geosynchronous satellites since the early 1970's. Electromagnetic pulses produced in connection with the differential charging of insulators can couple into the spacecraft harness and cause electronic switching anomalies. An investigation conducted to determine the response of the spacecraft surfaces to substorm particle fluxes makes use of a harness transient detector. The harness transient detector, called the Transient Event Counter (TEC) was built and integrated into the Canadian-American Communications Technology Satellite (CTS). A description of the TEC and its operational characteristics is given and the obtained data are discussed. The data show that the satellite surfaces appear to be charged to the point that discharges occur and that the discharge-induced transients couple into the wire harnesses.

Stevens, N. J.↗

An instrument for rapidly measuring plasma distribution functions with high resolution

An instrument which can rapidly measure plasma particle distribution functions has been developed based upon recent innovations in electrostatic analyzer design and position sensitive particle detection. The new analyzer uses a quadrispherical geometry, but has a completely uniform 360 deg fan-shaped field of view. The polar angular distribution of entering particles is spatially imaged onto a position sensitive detector at the annular exit aperture after a deflection through 90 deg. Several methods of position sensitive detection have been successfully used in conjunction with this analyzer. The simplest is individual channel multipliers spaced around the annular exit. Microchannel plate electron multipliers permit greater position resolution to be obtained, and a detector using microchannel plates followed by a resistive anode image converter obtains angular resolution of about one degree, i.e., 360 individual angle pixels. Instruments of this type were flown on a sounding rocket in early 1982 and will be included on the Giotto comet mission and the AMPTE ion release module (IRM).

Carlson, C. W.↗

Kinetics of hydrogen release from lunar soil

With increasing interest in a lunar base, there is a need for extensive examination of possible lunar resources. Hydrogen will be needed on a lunar base for many activities including providing fuel, making water, and serving as a reducing agent in the extraction of oxygen from its ores. Previous studies have shown the solar wind has implanted hydrogen in the lunar regolith and that hydrogen is present not only in the outer layer of soil but to considerable depths, depending on the sampling site. If this hydrogen is to be mined and used on the lunar surface, a number of questions need to be answered. How much energy must be expended in order to release the hydrogen from the soil. What temperatures must be attained, and how long must the soil be heated. This study was undertaken to provide answers to practical questions such as these. Hydrogen was determined using a Pyrolysis/GC technique in which hydrogen was released by heating the soil sample contained in a quartz tube in a resistance wire furnace, followed by separation and quantitative determination using a gas chromatograph with a helium ionization detector. Heating times and temperatures were varied, and particle separates were studied in addition to bulk soils. The typical sample size was 10 mg of lunar soil. All of the soils used were mature soils with similar hydrogen abundances. Pre-treatments with air and steam were used in an effort to find a more efficient way of releasing hydrogen.

Bustin, Roberta↗

Infrared astronomy from the Moon

The purpose of this paper is to exhibit the advantages and limitations to infrared astronomical observations form the moon. The most obvious apparent advantage is the lack of a lunar atmosphere; radiation arriving from the universe is neither extinguished nor refracted as it approaches the lunar surface. However, the Earth's atmosphere's protection against cosmic rays is also lost, and infrared detectors are highly sensitive to irradiation by energetic particles. A second apparent advantage is the relative ease with which beams from an array of telescopes can be interferometrically combined; again the vacuum environment with constant refractive index of unity throughout, permits combination without phase delay across the entire spectral range. But thermal radiation from optical components and stray radiation from the lunar environment, just outside the light path, tend to lessen that advantage, except in narrow-spectral-band spatial interferometry, in which only the radiation in individual spectral lines is mapped, and broad-band thermal emission can be effectively filtered out. On the Moon's night side, and in polar craters on the Moon, radiative cooling should permit the attainment of high sensitivity with large telescopes. Just as the proposed Edison spacecraft primary mirror is expected to reach temperatures around 40 K, so also large lunar primary mirrors might be expected to reach temperatures in that range, making the zodiacal glow the main source of noise at wavelengths shortward of 25 micrometers. The slow rota tion of the Moon, and the lack of vibrations from natural sources such as winds, should provide advantages in guiding on specific astronomical sources. To learn as much as possible about the difficulties of remote observations in a hostile environment, Antarctic observatories should be used as test beds for the rigors of lunar observations. The strenuous requirements for successful astronomical observations from the South Pole are similar to those expected to be encountered in observations conducted from the Moon.

Harwit, Martin↗

Software for Processing Flight and Simulated Data of the ATIC Experiment

ATIC (Advanced Thin Ionization Calorimeter) is a balloon borne experiment designed to measure the cosmic ray composition for elements from hydrogen to iron and their energy spectra from approx.50 GeV to near 100 TeV. It consists of a Si-matrix detector to determine the charge of a CR particle, a scintillator hodoscope for tracking, carbon interaction targets and a fully active BGO calorimeter. ATIC had its first flight from McMurdo, Antarctica from 28/12/2000 to 13/01/2001. The ATIC flight collected approximately 25 million events. A C++-class library for building different programs for processing flight and simulated data of the ATIC balloon experiment is described. This library is compatible with the ROOT-system and includes classes and methods for solving a number of problems as the following: Reading data files in different formats (raw-data format, ROOT-format, ASCII-format, different formats for simulated data); Transferring all these formats to the only inner format of the library; Reconstruction of trajectories of primary particles with BGO calorimeter only. The Monte-Carlo simulations with GEANT code were used to obtain the basic tables for computing error corridors and chi(sup 2)-values for the trajectories. Obtaining error corridors for searching for signal of primary particle in the Si-matrix; Searching for hit of primary particle in the Si-matrix with using of error corridor and other criteria (chi(sup 2)-values, agreement between signals in Si-matrix and in the upper layer of scintillator and others); Determination of charge of primary particle; Determination of energy deposit in BGO calorimeter.

Panov, A. D.↗

Simulation of Energy Response of the ATIC Calorimeter

ATIC (Advanced Thin Ionization Calorimeter) is a balloon borne experiment designed to measure the cosmic ray composition for elements from hydrogen to iron and their energy spectra from approx.50 GeV to near 100 TeV. It consists of a Si-matrix detector to determine the charge of a CR particle, a scintillator hodoscope for tracking, carbon interaction targets and a fully active BGO calorimeter. ATIC had its first flight from McMurdo, Antarctica from 28/12/2000 to 13/01/2001. The ATIC flight collected approximately 25 million events. For reconstruction of primary spectra from spectra of energy deposits measured in the experiment, correlations between kinetic energy of a primary particle E(sub kin) and energy deposit in the calorimeter E(sub d) should be known. For this purpose, simulations of energy response of the calorimeter on energy spectra of different nuclei were done. The simulations were performed by GEANT-3.21 code with QGSM generator for nucleus - nucleus interactions. The incident flux was taken as isotropic in the ATIC aperture. Primary spectra power-law by momentum were used as inputs according to standard models of cosmic ray acceleration. These spectra become power-law by kinetic energy at E(sub kin) higher than approx.20Mc(sup 2), where M is primary nucleus mass. It should be noted that energy deposit spectra measured by ATIC illustrate similar behavior. Distributions of ratio E(sub kin)/E(sub d) are presented for different energy deposits and for a set of primaries. For power-law regions of energy spectra at E(sub d)> or equal to 20Mc(sup 2) the obtained mean value of E(sub kin)/E(sub d) increases from approx.2.4 for protons to approx.3.1 for iron, while rms/ decreases from 50% for protons to about 15% for iron. These values were obtained for the spectral index gamma=1.6

Batkov, K. E.↗

Charge Resolution of the Silicon Matrix of the ATIC Experiment

ATIC (Advanced Thin Ionization Calorimeter) is a balloon borne experiment designed to measure the cosmic ray composition for elements from hydrogen to iron and their energy spectra from approx.50 GeV to near 100 TeV. It consists of a Si-matrix detector to determine the charge of a CRT particle, a scintillator hodoscope for tracking, carbon interaction targets and a fully active BGO calorimeter. ATIC had its first flight from McMurdo, Antarctica from 28/12/2000 to 13/01/2001. The ATIC flight collected approximately 25 million events. The silicon matrix of the ATIC spectrometer is designed to resolve individual elements from proton to iron. To provide this resolution careful calibration of each pixel of the silicon matrix is required. Firstly, for each electronic channel of the matrix the pedestal value was subtracted taking into account its drift during the flight. The muon calibration made before the flight was used then to convert electric signals (in ADC channel number) to energy deposits in each pixel. However, the preflight muon calibration was not accurate enough for the purpose, because of lack of statistics in each pixel. To improve charge resolution the correction was done for the position of Helium peak in each pixel during the flight . The other way to set electric signals in electronics channels of the Si-matrix to one scale was correction for electric channel gains accurately measured in laboratory. In these measurements it was found that small different nonlinearities for different channels are present in the region of charge Z > 20. The correction for these non-linearities was not done yet. In linear approximation the method provides practically the same resolution as muon calibration plus He-peak correction. For searching a pixel with the signal of primary particle an indication from the cascade in the calorimeter was used. For this purpose a trajectory was reconstructed using weight centers of energy deposits in BGO layers. The point of intersection of this trajectory with Si-matrix and its RMS was determined. The pixel with maximal signal in 3sigma region was taken as sought. The signal in this pixel was corrected by trajectory zenith angle. The preliminary results on charge resolution of the Si-matrix in the range from protons to iron are presented.

Zatsepin, V. I.↗

A modular solid state detector for measuring high energy heavy ion fragmentation near the beam axis

A multi-element solid state detector has been designed to measure fluences of fragments produced near the beam axis by high energy heavy ion beams in thick targets. The detector is compact and modular, so as to be readily reconfigured according to the range of fragment charges and energies to be measured. Preamplifier gain settings and detector calibrations are adjustable remotely under computer control. We describe the central detector, its associated detectors and electronics, triggering scheme, data acquisition and particle identification techniques, illustrated by data taken with 600 MeV/u 56Fe beams and thick polyethylene targets at the LBL Bevalac. The applications of this work to space radiation protection are discussed.

NASA Center HQS↗