Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Revisiting the cylindrical positive column in an axial magnetic field

This paper seeks to bring together past and present work in this area and to remove some recent inconsistencies. It concludes that while some aspects were not completely correct in the early work, the general picture of azimuthal motion of electrons and ions is an important feature and accounts for the diamagnetism of a bounded active plasma and other features of an axially magnetised plasma. It also introduces a means of testing the equations derived by interchanging electrons and positive ions; under such a 'transformation,' the equations to be solved should be identical. This is a fundamental principle and is implicit in treatments given in many of the standard texts, but not made explicit.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonmonotonic radial distribution of excited atoms in a positive column of pulsed direct currect discharges in helium

Nonmonotonic radial distributions of excited helium atoms have been experimentally observed in a positive column of pulsed helium discharges using planar laser induced fluorescence. Computational analysis of the discharge dynamics with a fluid plasma model confirms the experimental observations over a range of pressures and currents. The observed effect is attributed to the peculiarities of electron population-depopulation of the excited states during the 'dynamic discharge' conditions with strong modulations of the electric field maintaining the plasma.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluation of an automatic system for detection and positioning of small pore defects using digital radiography

A recently developed algorithm for positioning of small defects within metal bodies using digital radiography has been experimentally validated. The algorithm has been validated in the high contrast to noise limit. A calibration method has also been developed and validated. The average error in defect interspacings are found to be approximately 0.03mm with a maximum at 0.2 mm, this is at the same order as the errors predicted by simulations. The relative error in interspacings are all less than 2% which is comparable to simulated ideal case at 0.25%.

42 ENGINEERING↗

Thomson spectrometer-microchannel plate assembly calibration for MeV-range positive and negative ions, and neutral atoms

We report on the absolute calibration of a microchannel plate (MCP) detector, used in conjunction with a Thomson parabola spectrometer. The calibration delivers the relation between a registered count numbers in the CCD camera (on which the MCP phosphor screen is imaged) and the number of ions incident on MCP. The particle response of the MCP is evaluated for positive, negative, and neutral particles at energies below 1 MeV. As the response of MCP depends on the energy and the species of the ions, the calibration is fundamental for the correct interpretation of the experimental results. The calibration method and arrangement exploits the unique emission symmetry of a specific source of fast ions and atoms driven by a high power laser.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated ultrasonic particle positioning and low excitation light fluorescence imaging

A compact hybrid system has been developed to position and detect fluorescent micro-particles by combining a Single Photon Avalanche Diode (SPAD) imager with an acoustic manipulator. The detector comprises a SPAD array, light-emitting diode (LED), lenses, and optical filters. The acoustic device is formed of multiple transducers surrounding an octagonal cavity. By stimulating pairs of transducers simultaneously, an acoustic landscape is created causing fluorescent micro-particles to agglomerate into lines. The fluorescent pattern is excited by a low power LED and detected by the SPAD imager. Our technique combines particle manipulation and visualization in a compact, low power, portable setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic contraction of the positive column of a self-sustained glow discharge in air flow

We study the dynamic contraction of a self-sustained glow discharge in air in a rectangular duct with convective cooling. A two dimensional numerical model of the plasma contraction was developed in a cylindrical frame. The process is described by a set of time-dependent continuity equations for the electrons, positive and negative ions; gas and vibrational temperature; and equations which account for the convective heat and plasma losses by the transverse flux. Transition from the uniform to contracted state was analyzed. It was shown that such transition experiences a hysteresis, and that the critical current of the transition increases when the gas density drops. Possible coexistence of the contracted and uniform state of the plasma in the discharge, where the current flows along the density gradient of the background gas, is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional positive column structure in a discharge tube with radius discontinuity

The low-pressure (40 and 90 Pa) low-current (4 and 10 mA) direct current discharge in a tube with a sharp change of its radius is studied both numerically and experimentally. A fully self-consistent hybrid numerical model of a two-dimensional non-uniform positive column in neon is developed using a nonlocal approach. The model combines kinetic simulation of the electrons (under two-terms approach) and fluid description of the neon ions and permits to calculate the distribution of all plasma parameters in the direct current discharges in the cameras with cylindrical geometry and radius discontinuity. The simulation results are compared with the measured 585.3 nm neon spectral line absolute intensities and excited 1s{sub 3} metastable neon atom number densities. Non-local electron kinetics in the transition region and formation of standing strata are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A button - type beam position monitor design for TARLA facility

Turkish Accelerator and Radiation Laboratory in Ankara (TARLA) facility is proposed as an IR FEL and Bremsstrahlung facility as the first facility of Turkish Accelerator Center (TAC). TARLA is essentially proposed to generate oscillator mode FEL in 3-250 microns wavelengths range, will consist of normal conducting injector system with 250 keV beam energy, two superconducting RF accelerating modules in order to accelerate the beam 15-40 MeV. The TARLA facility is expected to provide two modes, Continuous wave (CW) and pulsed mode. Longitudinal electron bunch length will be changed between 1 and 10 ps. The bunch charge will be limited by 77pC. The design of the Button-type Beam Position Monitor for TARLA IR FEL is studied to operate in 1.3 GHz. Mechanical antenna design and simulations are completed considering electron beam parameters of TARLA. Ansoft HFSS and CST Particle Studio is used to compare with results of simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new UHV micro positioning system for high load

In this work we report the design and performance of a novel compact in-vacuum actuator, designed to be compatible with all the motions required for the scissor-type ESRF mirror bender. These mirror benders include several linear actuators, which drive the mirror bending torques, as well as the main alignment motions such as pitch and translation along the normal to the mirror surface. The motions are provided by compact linear actuators, which consist of motor, reduction, spindle and nut, encapsulated on a closed air volume to provide vacuum compatibility. The actuator includes a hydroformed bellows to transmit the force to the actuator tip, and an electrical feedthrough for the motor cables. The design boundaries for these actuators are quite tight, as they must be integrated in a narrow volume, must be UHV compatible and must provide high resolution, for a relatively high load. As a result, they have limited mechanical performance, and in some cases poor reliability. To overcome these problems, we designed and implemented a different concept. In the proposed concept, the motor rotation is converted onto a linear motion by means of a cam instead of a spindle and a nut. This allows for much shorter and stiffer transmission system, with similar dimensions. The vacuum compatibility is intrinsic for this solution, since the whole mechanism of the actuator is UHV compatible. All motions are preloaded and guided by vacuum compatible (hybrid metal-ceramics) ball bearings. This allows the system reaching a repeatability and backlash well within the micron. The absence of friction allows for a high reliability and releases the maintenance needs of the system. The transmission is intrinsically irreversible, and the system can hold a load of 250 N within a few nanometers without any holding current on the motors. This allows the system to move reliably also in micro-stepping mode, providing a resolution well below the half-step nominal resolution of 100 nm. Performances have been tested on a prototype. We report the results of the tests obtained in air and in vacuum after bake-out. Two units of the new actuator have been installed at the photoemission beamline of ALBA (CIRCE) and are routinely used to align the 3 µm spot on the field of view of the Photoemission Electron Microscope. The absence of any noticeable backlash, or any friction effect and the reliability of the micro-stepping motion has simplified very much the alignment of the photon beam, reducing the alignment process to few minutes. The excellent performances and relatively high load capacity of this new compact actuator make of it a versatile element to be integrated in other systems requiring reliable in-vacuum positioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal management and prototype testing of Compton scattering X-ray beam position monitor for the Advanced Photon Source Upgrade

Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source Upgrade. In the next-generation XBPMs for the canted-undulator front ends, where two undulator beams are separated by 1.0 mrad, the lower beam power (<10 kW) per undulator allows us to explore lower-cost solutions based on Compton scattering from a diamond placed edge-on to the x-ray beam. Because of the high peak power density of the x-ray beams, this diamond experiences high temperatures and has to be clamped to a water-cooled heat spreader using thermal interface materials (TIMs), which play a key role in reducing the temperature of the diamond. To evaluate temperature changes through the interface via thermal simulations, the thermal contact resistance (TCR) of TIMs at an interface between two solid materials under even contact pressure must be known. This paper addresses the TCR measurements of several TIMs, including gold, silver, pyrolytic graphite sheet, and 3D graphene foam. In addition, a prototype of a Compton-scattering XBPM with diamond blades was installed at APS Beamline 24-ID-A in May 2015 and has been tested. This study presents the design of the Compton-scattering XBPM, and compares thermal simulation results obtained for the diamond blade of this XBPM by the finite element method with in situ empirical measurements obtained by using reliable infrared technology.

43 PARTICLE ACCELERATORS↗

A Crystal Structure of a Dimer of the Antibiotic Ramoplanin Illustrates Membrane Positioning and a Potential Lipid II Docking Interface

The glycodepsipeptide antibiotic ramoplanin A2 is in late stage clinical development for the treatment of infections from Gram-positive pathogens, especially those that are resistant to first line antibiotics such as vancomycin. Ramoplanin A2 achieves its antibacterial effects by interfering with production of the bacterial cell wall; it indirectly inhibits the transglycosylases responsible for peptidoglycan biosynthesis by sequestering their Lipid II substrate. Lipid II recognition and sequestration occur at the interface between the extracellular environment and the bacterial membrane. Therefore, we determined the structure of ramoplanin A2 in an amphipathic environment, using detergents as membrane mimetics, to provide the most physiologically relevant structural context for mechanistic and pharmacological studies. We report here the X-ray crystal structure of ramoplanin A2 at a resolution of 1.4 {angstrom}. This structure reveals that ramoplanin A2 forms an intimate and highly amphipathic dimer and illustrates the potential means by which it interacts with bacterial target membranes. The structure also suggests a mechanism by which ramoplanin A2 recognizes its Lipid II ligand.

36 MATERIALS SCIENCE↗

Stretched and Filtered Multigroup Pn Transport for Improved Positivity and Accuracy

One of the common methods for solving the radiation transport equation is to use a polynomial expansion for the angle variable(s). Recent research that reduces the oscillations and improves the positivity of the gray transport equation solutions is here applied to the multigroup transport equations. Constant scale factors that stretch the time axis and constant scattering opacities that filter the solution greatly increase the accuracy of the solution with no added nonlinearities. No new solution techniques are required. Test problems are presented in one and two dimensions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Architecture of a Silicon Strip Beam Position Monitor

A collaboration between Fermilab and the Institute for High Energy Physics (IHEP), Beijing, has developed a beam position monitor for the IHEP test beam facility. This telescope is based on 5 stations of silicon strip detectors having a pitch of 60 microns. The total active area of each layer of the detector is about 12 x 10 cm{sup 2}. Readout of the strips is provided through the use of VA1 ASICs mounted on custom hybrid printed circuit boards and interfaced to Adapter Cards via copper-over-kapton flexible circuits. The Adapter Cards amplify and level-shift the signal for input to the Fermilab CAPTAN data acquisition nodes for data readout and channel configuration. These nodes deliver readout and temperature data from triggered events to an analysis computer over gigabit Ethernet links.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Osteocalcin binds to a GPRC6A Venus fly trap allosteric site to positively modulate GPRC6A signaling

GPRC6A, a member of the Family C G-protein coupled receptors, regulates energy metabolism and sex hormone production and is activated by diverse ligands, including cations, L-amino acids, the osteocalcin (Ocn) peptide and the steroid hormone testosterone. We sought a structural framework for the ability of multiple distinct classes of ligands to active GPRC6A. We created a structural model of GPRC6A using Alphafold2. Using this model we explored a putative orthosteric ligand binding site in the bilobed Venus fly trap (VFT) domain of GPRC6A and two positive allosteric modulator (PAM) sites, one in the VFT and the other in the 7 transmembrane (7TM) domain. We provide evidence that Ocn peptides act as a PAM for GPRC6A by binding to a site in the VFT that is distinct from the orthosteric site for calcium and L-amino acids. In agreement with this prediction, alternatively spliced GPRC6A isoforms 2 and 3, which lack regions of the VFT, and mutations in the computationally predicted Ocn binding site, K352E and H355P, prevent Ocn activation of GPRC6A. These observations explain how dissimilar ligands activate GPRC6A and set the stage to develop novel molecules to activate and inhibit this previously poorly understood receptor.

59 BASIC BIOLOGICAL SCIENCES↗

Towards a deep characterization of a 64-fold-pixelated position sensitive detector for a new {gamma}-scanning system of HPGe segmented detectors

Characterization of the electrical response of the HPGe segmented detectors is one of the current goals for the Nuclear Physics community in order to perform {gamma}-ray tracking or even imaging with these detectors. For this purpose, scanning devices have to be developed to achieve the signal-position association with the highest precision. In this laboratory, a new scanning system, SALSA (Salamanca Lyso-based Scanning Array), consisting on a high spatial resolution {gamma} camera, is a under development. In this work the whole scanning system is presented and first results for the characterization of the {gamma} camera are shown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Analysis of Positive-feedback-based Active Anti-islanding Schemes for Inverter-Based Distributed Generators

Recently proposed positive-feedback-based anti-islanding schemes (AI) are highly effective in preventing islanding without causing any degradation in power quality. This paper aims to analyze the performance of these schemes quantitatively in the context of the dynamic models of inverter-based distributed generators (DG). In this study, the characteristics of these active anti-islanding methods are discussed and design guidelines are derived.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AMAROK: A Radio Frequency Development Platform for High-Power, Full-Scale Positive Ion Sources for DIII-D Neutral Beam Injectors

Next-generation neutral beam injection (NBI) systems demand RF ion sources capable of efficiently coupling >120 kW at 2–4-MHz frequencies, yet existing designs face voltage standoff and impedance-matching challenges. To address this, the advanced multicoil antenna for RF operations at kilowatts (AMAROK) was developed as a high-power RF inductively coupled plasma (ICP) source delivering up to 200 kW in the 2–4-MHz range via four phase-controlled generators for flexible power sharing. Two antenna designs—a single-strap multiturn (MT) and a multistrap single-turn (ST) design—were evaluated to optimize resonance, impedance matching, and power coupling across plasma loads. Here, a semi-analytical self-resonant frequency (SRF) model, validated experimentally, predicts resonance trends for arbitrary turn counts and tubing diameters, enabling rapid antenna optimization. Strap-to-strap mutual inductance in the ST configuration showed strong spatial dependence, guiding generator operation and total load inductance. These insights informed a custom π -topology matching network, achieving stable impedance matching over a wide range of plasma-driven loads. Collectively, these results position AMAROK as a versatile testbed for advancing high-power RF source technology in fusion NBI applications.

DIII-D↗

The Effect of Positioning on Ureteral Stone Retropulsion: “Gravity Works”

To evaluate the potential impact of alterations in “patient” position on laser-induced ureteral stone retropulsion in an in vitro model. In this paper, a ceramic (phantom) stone was placed in a water-filled clear polymer tube and subjected to continuous laser energy until the stone had retropulsed a distance of 10cm. The trial was stopped after 60 seconds if the stone had not reached 10cm. The time and total energy needed to cause 10cm of retropulsion were recorded at an incline angle of 0°, 10°, 20°, and 40°; ten trials at each angle were completed. The study was then repeated with pure calcium phosphate brushite stones. Retropulsion decreased with increasing incline angle of the saline-filled clear polymer tube. At 0° of incline the phantom stone reached a distance of 10cm after 7.4 seconds. At 10°, 20°, and 40° the phantom stone migrated a mean maximum distance of 3.1 cm, 1.2 cm, and 0.7 cm, respectively, and the trial was stopped after 60 seconds. For the calcium phosphate stone, at 0° and 10° of incline, the stone reached 10cm after 6.9 seconds and 42.8 seconds respectively (p<0.05). At 20° and 40°, the calcium phosphate stone moved a mean maximum distance of 2.4cm and 1cm, and the trial was stopped after 60 seconds. Alterations in the angle of inclination reduced stone retropulsion during ureteroscopic lithotripsy in an in vitro model to <1cm. Finally, increasing the incline angle of a patient may effectively preclude retropulsion when performing laser lithotripsy of ureteral stones.

60 APPLIED LIFE SCIENCES↗