Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON SCIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Back-Stress and Its Evolution during Primary Creep in Particle Strengthened Nickel Superalloys

According to Eshelby’s theory, inelastically inhomogeneous inclusions in a metallic matrix give rise to a distribution of internal stresses. In the case of particle strengthened materials, such as nickel base superalloys, the presence and evolution of this back-stress leads to various observable effects, such as primary creep, back-flow upon loading, and memory of prior deformation. This article presents the background of the concept of back-stress and how it applies to the scenario of creep. A derivation of an evolution equation for back-stress in the context of primary creep is also presented. The results from neutron diffraction with in-situ creep experiments on directionally solidified nickel superalloys are presented in order to demonstrate the validity of the proposed equation and the corollaries derived therefrom.

36 MATERIALS SCIENCE↗

Side Chain Dynamics of Poly(norbornene)- g -Poly(propylene oxide) Bottlebrush Polymers

The segmental dynamics of the side chains of poly(norbornene)- g -poly(propylene oxide) (PNB- g -PPO) bottlebrush polymer in comparison to PPO is studied by quasi-elastic neutron scattering. Having experimental time and length scale information simultaneously allows to extract spatial information in addition to relaxation time. Tethering one end of the PPO side chain onto a stiff PNB backbone slows down the segmental relaxation, over the length and time scales investigated. The power law dependence of the relaxation time on the momentum transfer, Q , indicates a more heterogeneous relaxation pattern for the bottlebrush polymer, whereas the linear PPO has less deviations from a homogenous relaxation. Similar conclusions can be drawn from the time dependent mean square displacement, $\langle$ r 2 ( t )$\rangle$, and the non-Gaussian parameter, α 2 ( t ). Herein, the bottlebrush polymer shows a more restricted dynamics, whereas the linear PPO reaches $\langle$ r 2 ( t )$\rangle$∝ t 0.5 at the highest temperature. The deviations from Gaussian behavior are evident at the α 2 ( t ). Both samples show a decaying α 2 ( t ). Finally, the non-Gaussian parameter supports the results from the power law dependence of the relaxation times, with lower α 2 ( t ) values for PPO compared to those for PNB-g-PPO, pointing to less deviations from Gaussian behavior.

36 MATERIALS SCIENCE↗

Neutron Resonance Transmission Analysis (NRTA): A Nondestructive Assay Technique for the Next Generation Safeguards Initiative’s Plutonium Assay Challenge

This is an end-of-year report for a project funded by the National Nuclear Security Administration's Office of Nuclear Safeguards (NA-241). The goal of this project is to investigate the feasibility of using Neutron Resonance Transmission Analysis (NRTA) to assay plutonium in commercial light-water-reactor spent fuel. This project is part of a larger research effort within the Next-Generation Safeguards Initiative (NGSI) to evaluate methods for assaying plutonium in spent fuel, the Plutonium Assay Challenge. The first-year goals for this project were modest and included: 1) developing a zero-order MCNP model for the NRTA technique, simulating data results presented in the literature, 2) completing a preliminary set of studies investigating important design and performance characteristics for the NRTA measurement technique, and 3) documentation of this work in an end of the year report (this report). Research teams at Los Alamos National Laboratory (LANL), Lawrence Berkeley National Laboratory (LBNL), Pacific Northwest National Laboratory (PNNL), and at several universities are also working to investigate plutonium assay methods for spent-fuel safeguards. While the NRTA technique is well proven in the scientific literature for assaying individual spent fuel pins, it is a newcomer to the current NGSI efforts studying Pu assay method techniques having just started in March 2010; several analytical techniques have been under investigation within this program for two to three years or more. This report summarizes a nine month period of work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of neutron irradiation on Al-6061 alloy produced via ultrasonic additive manufacturing

Samples of aluminum alloy 6061 produced via ultrasonic additive manufacturing (UAM) were irradiated in the High Flux Isotope Reactor (HFIR) up to 17.3 dpa at ~70°C while in contact with water using perforated rabbit capsules. The irradiation campaign included as-received (AR) material, specimens subjected to various post-weld heat treatments (PWHTs, including hot isostatic pressing [HIP]), and reference (wrought) alloy samples. Mechanical tensile tests, accompanied by digital image correlation (DIC) analysis, fractography, and metallography, were performed as a part of the post-irradiation evaluation. The X- and Y-specimens (i.e., oriented in the sonotrode moving and vibration directions, respectively) showed pronounced radiation hardening and ductility decrease. Specific serration flow behavior and propagation of deformation bands were observed under various material conditions up to 3.5 dpa but disappeared at 17.3 dpa. In all cases, the fracture mechanism of X- and Y-specimens was ductile; ductile dimples dominated the fracture surface. Irradiated X- and Y-specimens showed good performance, regardless of material conditions (AR or PWHT). The performance of Z-specimens oriented in the build direction was strongly dependent on the PWHT. The AR and aged specimens showed fracture stress decrease with dose, and they experienced fracture under irradiation after 3.5 dpa; specimen cross section analysis revealed specific interface degradation that was likely related to corrosion. Recrystallization significantly improved in-reactor performance. Finally, HIP suppressed interface degradation due to recrystallization and pore removal, which led to good in-reactor performance for Z-specimens.

36 MATERIALS SCIENCE↗

Digitized two-parameter spectrometer for neutron-gamma mixed field

This paper shows the results of digital processing of output pulses from combined photon-neutron detector using a commercially available digitizer ACQUIRIS DP 210. The advantage of digital processing is reduction of the apparatus in weight and size, acceleration of measurement, and increased resistance to pile-up of pulses. The neutron and photon spectrum of radionuclide source {sup 252}Cf is presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross sections for neutron-induced reactions from surrogate data: Reexamining the Weisskopf-Ewing approximation for ( n , n ' ) and ( n , 2 n ) reactions

Background: Modeling nuclear reaction networks for nuclear science applications and for simulations of astrophysical environments relies on cross section data for a vast number of reactions, many of which have never been measured. Cross sections for neutron-induced reactions on unstable nuclei are particularly scarce, since they are the most difficult to measure. Consequently, we must rely on theoretical predictions or indirect measurements to obtain the requisite reaction data. For compound nuclear reactions, the surrogate reaction method can be used to determine many cross sections of interest. Purpose: Earlier work has demonstrated that cross sections for neutron-induced fission and radiative neutron capture can be determined from a combination of surrogate reaction data and theory. For the fission case, it was shown that the Weisskopf-Ewing approximation, which significantly simplifies the implementation of the surrogate method, can be employed. Capture cross sections cannot be obtained, and require a detailed description of the surrogate reaction process. Here, we examine the validity of the Weisskopf-Ewing approximation for determining unknown (n, n') and (n, 2n) cross sections from surrogate data. Methods: Using statistical reaction calculations with realistic parametrizations, we investigate first whether the assumptions underlying the Weisskopf-Ewing approximation are valid for (n, n') and (n, 2n) reactions on representative target nuclei. We then produce simulated surrogate reaction data and assess the impact of applying the Weisskopf-Ewing approximation when extracting (n, n') and (n, 2n) cross sections in situations where the approximation is not strictly justified. Results: We find that peak cross sections can be estimated using the Weisskopf-Ewing approximation, but the shape of the (n, n') and (n, 2n) cross sections, especially for low neutron energies, cannot be reliably determined without accounting for the angular-momentum differences between the neutron-induced and surrogate reaction. Conclusions: To obtain reliable (n, n') and (n, 2n) cross sections from surrogate reaction data, a detailed description of the surrogate reaction mechanisms is required. To do so for the compound-nucleus energies and decay channels relevant to these reactions, it becomes necessary to extend current modeling capabilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of antimicrobial peptide on dynamics of phosphocholine membrane: role of cholesterol and physical state of bilayer

Antimicrobial peptides are universal in all forms of life and are well known for their strong interaction with the cell membrane. This makes them a popular target for investigation of peptide-lipid interactions. Here we report the effect of melittin, an important antimicrobial peptide, on the dynamics of membranes based on 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) lipid in both the solid gel and fluid phases. To probe the phase transition, elastic neutron intensity temperature scans have been carried out on DMPC-based unilamellar vesicles (ULV) with and without melittin. We have found that addition of a small amount (0.2 mol%) melittin eliminates the steep fall in the elastic intensity at 296 K associated with the solid gel to fluid phase transition, which is observed for pure DMPC vesicles. Quasielastic neutron scattering (QENS) experiments have been carried out on DMPC ULV in the solid gel and fluid phases with and without 0.2 mol % melittin. The data analysis invariably shows the presence of lateral and internal motions of the DMPC molecule. We found that melittin does have a profound effect on the dynamics of lipid molecules, especially on the lateral motion, and affects it in a different way, depending on the phase of the bilayers. In the solid gel phase, it acts as a plasticizer, enhancing the lateral motion of DMPC. However, in the fluid phase it acts as a stiffening agent, restricting the lateral motion of the lipid molecules. These observations are consistent with the mean squared displacements extracted from the elastic intensity temperature scans. Cholesterol is a vital component of eukaryotic membrane, which is a natural target for melittin. To investigate the effect of melittin on vesicles supplemented with cholesterol, QENS experiments have also been carried out on DMPC ULV with 20 mol% cholesterol in the presence and absence of 0.2 mol% melittin. Remarkably, the effects of melittin on the membrane dynamics disappear in the presence of 20 mol % cholesterol. Thus, our measurements indicate that the destabilizing effect of the peptide melittin on membranes can be mitigated by the presence of cholesterol.

59 BASIC BIOLOGICAL SCIENCES↗

Magnetic field induced antiferromagnetic cone structure in multiferroic BiFeO 3

Neutron diffraction measurements were performed under high magnetic fields up to 17 T in a multiferroic BiFeO 3 single crystal, in which an intermediate magnetic (IM) phase has been found between the cycloid and canted antiferromagnetic phases [S. Kawachi et al., Phys. Rev. Mater. 1, 024408 (2017)]. We clearly found that the incommensurate magnetic peaks, which split perpendicular to the magnetic field in the cycloid phase, rotate by 90 deg to align parallel to the field in the IM phase. The magnetic structure in the IM phase can be best described by an antiferromagnetic cone (AF cone) structure. The transition from the cycloid to AF cone is of first order and the direction of the magnetic wave vector and the easy plane of the cycloidal component are rotated by 90 deg without changing the cycloidal modulation period, whereas the transition from the AF cone to canted antiferromagnetic phase is gradual and the cone angle becomes smaller gradually without changing the modulation period. Interestingly, the cycloidal component as well as the cone angle in the IM phase shows a large hysteresis between the field increasing and decreasing processes. Finally, this result, combined with the magnetostriction with a large hysteresis previously reported in the IM phase, suggests a strong magnetoelastic coupling.

36 MATERIALS SCIENCE↗

Hermeticity of SiC/SiC composite and monolithic SiC tubes irradiated under radial high-heat flux

Demonstration of hermetic SiC fiber–reinforced SiC matrix composite cladding under normal operating environments has been identified as one of the most critical feasibility issues for accident-tolerant fuel cladding in light-water reactors. This study provides critical experimental data needed for understanding the effects of irradiation on hermeticity. SiC composite and monolithic tubes were neutron-irradiated to 2 displacements per atom with and without a nominal radial heat flux of 0.6 MW/m2 to produce a simulated in-pile stress state for the normal operation of a light-water reactor. The through-thickness temperature gradient under irradiation results in a gradient in swelling, which causes a significant stress buildup. Such irradiation-induced stress was modeled using a commercial finite element analysis code. The radial heat flux–irradiation synergism was experimentally investigated by constructing a special irradiation capsule and evaluating the helium hermeticity of the specimens. The simulated stress state exhibited a near equi-biaxial tensile axial and hoop stress of ~150 MPa at the inner surface of the SiC composite tube. This stress level is potentially beyond the matrix cracking stress. Degradation of hermeticity of the SiC composite tubes was observed after irradiation, indicating irradiation-induced cracking, whereas the irradiated monolithic SiC tubes remained hermetic. In conclusion, the results indicate that loss of hermeticity caused by radiation-induced microcracking is a potential issue for SiC composite cladding, depending on the magnitude of the temperature gradients. Coating the outer surface of the cladding was identified as a mitigation strategy that might overcome the cracking issue.

36 MATERIALS SCIENCE↗

Neutron detector characterization for SCINTIA array

SCINTIA is a new detector array of organic scintillators under development at the Inst. for Reference Materials and Measurements (IRMM). The present design of SCINTIA includes NE213, p-terphenyl and Li glass neutron detectors positioned in a spherical configuration around the target. The properties of a novel p-terphenyl neutron detector to be used with SCINTIA have been investigated using photon sources and neutrons from a time tagged {sup 252}Cf(sf) source. The results show that the p-terphenyl crystal has better energy resolution, increased proton light output and neutron efficiency when compared to a similar size NE213 equivalent neutron detector. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse Mode Calibration of the Micro Pocket Fission Detector

The Micro-Pocket Fission Detector (MPFD) is a neutron sensor currently under development in the High Temperature Test Laboratory (HTTL) for use as a supporting instrument during material testing experiments performed at TREAT. The detector has the capability to observe the real-time neutron population while surviving the harsh radiation, and temperature conditions, which sets it apart from most neutron sensitive devices. The next step in the instrument development process is to define a method of calibrating pulse-mode operations. This procedure will allow the detector to be calibrated to allow for absolute measurements of localized neutron population in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel in-situ, lift-out, three-point bend technique to quantify the mechanical properties of an ex-service neutron irradiated inconel X-750 component

A first of its kind small scale mechanical testing technique involving micro-three-point bending was invented, developed, and implemented on reactor irradiated, active Inconel X-750 components removed from service after approximately 53 and 67 dpa. These tests were performed at ambient room temperature in-situ using a scanning electron microscope in order to obtain live recordings of sample deformation and loading curves. Sample and testing apparatus preparation required novel lift-out and fabrication processes. Materials from two irradiation temperature regimes, low temperature (120-280 °C) and high temperature (300 ± 15 °C) were examined. Manufacturing and finishing (grinding) of this component create differences between its edge and center, so micro-specimens from both areas were extracted in order to study these differences. According to three-point beam bending theory, a 0.2% offset yield stress parameter is introduced and calculated for all specimens. Differences in mechanical properties due to irradiation temperature and dose effects were observed. Material irradiated at the higher temperature exhibited yield strength increases of ~540 MPa after 53 dpa and ~1000 MPa after 67 dpa. There was little difference (≤310 MPa) in yield strength between materials irradiated at the lower temperature at 53 dpa and 67 dpa compared with non-irradiated material. Differences in yield strengths between the edge and center of the component are retained after irradiation. The difference in yield strengths for the edge and center regions was ~740 MPa for non-irradiated material. After irradiation to a dose of 67 dpa these differences were ~570 MPa for the lower irradiation temperature and ~710 MPa for higher irradiation temperature. There were no indications of grain boundary failures via cracking except for material irradiated to 67 dpa at low temperature.

36 MATERIALS SCIENCE↗

Equation of state and strain-induced stabilization of δ-phase stabilized plutonium alloys

An in-situ high-pressure neutron diffraction experiment was conducted on a δ-phase stabilized plutonium alloy with isotope 242 Pu. Upon room-temperature compression, neither of the previously reported pressure-induced transformation paths, δ → α' or δ → γ’ → α', was observed up to 1.2 GPa. Instead, a drastic reduction in the diffraction intensity of the δ phase was observed when the pressure was above 0.8 GPa. At the highest pressure of the experiment (1.2 GPa), the diffraction data appear to be characteristic of an amorphous state, manifested by the diminishing intensities of all diffraction lines. Additionally, no evidence was found to support the transformation to a body-centered tetragonal structure (δ’), which was previously inferred from the diffraction line broadening during initial compression to 0.1 GPa. The discrepancies between the present and previous experiments suggest a substantial strain-induced stabilization of the δ-phase and is presumably attributed to the different stress states in the high-pressure environments. From the pressure - volume measurements, the determined isothermal bulk modulus for the δ-phase is in the range of 31.9 ± 1.3–34.8 ± 1.8 GPa using different pressure scales, comparable to those obtained from the resonant ultrasound spectroscopy measurements of the alloys of similar composition. Finally, the pressure-induced elastic softening is neither convinced in the present work, nor can it be resolved from the diffraction experiments if it is intrinsically weak.

36 MATERIALS SCIENCE↗

Neutron-induced electronic failures around a high-energy linear accelerator

Purpose: After a new in-vault CT-on-rails system repeatedly malfunctioned following use of a high-energy radiotherapy beam, we investigated the presence and impact of neutron radiation on this electronic system, as well as neutron shielding options. Methods: We first determined the CT scanner's failure rate as a function of the number of 18 MV monitor units (MUs) delivered. We then re-examined the failure rate with both 2.7-cm-thick and 7.6-cm-thick borated polyethylene (BPE) covering the linac head for neutron shielding. To further examine shielding options, as well as to explore which neutrons were relevant to the scanner failure, Monte Carlo simulations were used to calculate the neutron fluence and spectrum in the bore of the CT scanner. Simulations included BPE covering the CT scanner itself as well as covering the linac head. Results: We found that the CT scanner had a 57% chance of failure after the delivery of 200 MUs. While the addition of neutron shielding to the accelerator head reduced this risk of failure, the benefit was minimal and even 7.6 cm of BPE was still associated with a 29% chance of failure after the delivery of 200 MU. This shielding benefit was achieved regardless of whether the linac head or CT scanner was shielded. Additionally, it was determined that fast neutrons were primarily responsible for the electronic failures. Conclusions: As illustrated by the CT-on-rails system in the current study, physicists should be aware that electronic systems may be highly sensitive to neutron radiation. Medical physicists should therefore monitor electronic systems that have not been evaluated for potential neutron sensitivity. This is particularly relevant as electronics are increasingly common in the therapy vault and newer electronic systems may exhibit increased sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-21: A D-D Based Neutron Generator System for Boron Neutron Capture Therapy: A Feasibility Study

Purpose: To investigate the feasibility of a deuterium-deuterium (DD) neutron generator for application in boron neutron capture therapy (BNCT) of brain cancer Methods: MCNP simulations were performed using a head phantom and a monoenergetic neutron source, which resembles the point source in a DD generator that emits 2.45-MeV neutrons. Source energies ranging from 5eV to 2.45MeV were simulated to determine the optimal treatment energy. The phantom consisted of soft tissue, brain tissue, skull, skin layer, and a brain tumor of 5 cm in diameter. Tumor depth was varied from 5–10 cm. Boron-10 concentrations of 10 ppm, 15 ppm, and 30 ppm were used in the soft/brain tissues, skin, and tumor, respectively. The neutron flux required to deliver 60 Gy to the tumor as well as the normal tissue doses were determined. Results: Beam energies between 5eV and 10keV obtained doses with the highest dose ratios (3.3–25.9) between the tumor and the brain at various depths. The dose ratio with 2.45-MeV neutrons ranged from 0.8–6.6. To achieve the desired tumor dose in 40 minutes, the required neutron flux for a DD generator was between 8.8E10 and 5.2E11 n/s and the resulting brain dose was between 2.3 and 18 Gy, depending on the tumor depth. The skin and soft tissue doses were within acceptable tolerances. The boron-neutron interaction accounted for 54–58% of the total dose. Conclusion: This study shows that the DD neutron generator can be a feasible neutron source for BNCT. The required neutron flux for treatment is achievable with the current DD neutron technology. With a well-designed beam shaping assembly and treatment geometry, the neutron flux can be further improved and a 60-Gy prescription can be accurately delivered to the target while maintaining tolerable normal tissue doses. Further experimental studies will be developed and conducted to validate the simulation results.

60 APPLIED LIFE SCIENCES↗

Event Centroiding Applied to Energy-Resolved Neutron Imaging at LANSCE

The energy-dependence of the neutron cross section provides vastly different contrast mechanisms than polychromatic neutron radiography if neutron energies can be selected for imaging applications. In recent years, energy-resolved neutron imaging (ERNI) with epi-thermal neutrons, utilizing neutron absorption resonances for contrast as well as for quantitative density measurements, was pioneered at the Flight Path 5 beam line at LANSCE and continues to be refined. In this work, we present event centroiding, i.e., the determination of the center-of-gravity of a detection event on an imaging detector to allow sub-pixel spatial resolution and apply it to the many frames collected for energy-resolved neutron imaging at a pulsed neutron source. While event centroiding was demonstrated at thermal neutron sources, it has not been applied to energy-resolved neutron imaging, where the energy resolution requires to be preserved, and we present a quantification of the possible resolution as a function of neutron energy. For the 55 μm pixel size of the detector used for this study, we found a resolution improvement from ~80 μm to ~22 μm using pixel centroiding while fully preserving the energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Black hole–neutron star mergers: The first mass gap and kilonovae

Observations of X-ray binaries indicate a dearth of compact objects in the mass range from ~2 –5 M ⊙ . The existence of this (first mass) gap has been used to discriminate between proposed engines behind core-collapse supernovae. From LIGO/Virgo observations of binary compact remnant masses, several candidate first mass gap objects, either neutron stars (NSs) or black holes (BHs), were identified during the O3 science run. Motivated by these new observations, we study the formation of BH-NS mergers in the framework of isolated classical binary evolution, using population synthesis methods to evolve large populations of binary stars (Population I and II) across cosmic time. We present results on the NS to BH mass ratios (q = M NS /M BH ) in merging systems, showing that although systems with a mass ratio as low as q = 0.02 can exist, typically BH-NS systems form with moderate mass ratios q = 0.1 –0.2. If we adopt a delayed supernova engine, we conclude that ~30% of BH-NS mergers may host at least one compact object in the first mass gap (FMG). Even allowing for uncertainties in the processes behind compact object formation, we expect the fraction of BH-NS systems ejecting mass during the merger to be small (from ~0.6 –9%). In our reference model, we assume: (i) the formation of compact objects within the FMG, (ii) natal NS/BH kicks decreased by fallback, (iii) low BH spins due to Tayler-Spruit angular momentum transport in massive stars. We find that ≲1% of BH-NS mergers will have any mass ejection and about the same percentage will produce kilonova bright enough to have a chance of being detected with a large (Subaru-class) 8 m telescope. Interestingly, all these mergers will have both a BH and an NS in the FMG.

79 ASTRONOMY AND ASTROPHYSICS↗