Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Neuro-Motor Responses to Daily Centrifugation in Bed-Rested Subjects

It is well known from numerous space flight studies that exposure to micro-g produces both morphological and neural adaptations in the major postural muscles. However, the characteristics and mechanism of these changes, particularly when it may involve the central nervous system are not defined. Furthermore, it is not known what role unloading of the muscular system may have on central changes in sensorimotor function or if centrifugation along the +Gz direction (long body axis) can mitigate both the peripheral changes in muscle function and modification of the central changes in sensorimotor adaptation to the near weightless environment of space flight. The purpose of this specific effort was, therefore, to investigate the efficacy of artificial gravity (AG) as a method for maintaining sensorimotor function in micro-g. Eight male subjects were exposed to daily 1 hr centrifugation during a 21 day 6 degree head-down bed rest study. Seven controls were placed on the centrifuge without rotation. The radius and angular velocity of the centrifuge were adjusted such that each subject experienced a centripetal acceleration of 2.5g at the feet, and approximately 1.0g at the heart. Both the tendon (MSR) and functional stretch reflexes (FSR) were collected using an 80 lb. ft. servomotor controlled via position feedback to provide a dorsiflexion step input to elicit the MSR, and the same step input with a built in 3 sec hold to evoke the FSR. EMG data were obtained from the triceps surae. Supplementary torque, velocity and position data were collected with the EMG responses. All data were digitized and sampled at 4 kHz. Only the MSR data has been analyzed at this time, and preliminary results suggest that those subjects exposed to active centrifugation (treatment group) show only minor changes in MSR peak latency times, either as a function of time spent in bed rest or exposure to centrifugation, while the control subjects show delays in the MSR peak latencies that are typical of bed rested subjects. There also appears to be a trend in the treatment group where centrifugation results in peak latencies that are shorter than the control group. This trend is supported by the observation that peak reflex amplitudes are larger (up to 40% in magnitude)than those of the control subjects. Furthermore, centrifugation tends, by day 21 of bed rest, to normalize the peak amplitudes to the amplitudes observed prior to bed rest or centrifugation. From a preliminary point of view, centrifugation appears to have a positive effect on the sensorimotor system, and specifically on those muscles that provide anti-gravity and postural support.

Reschke, Millard F.↗

Experimental Performance Evaluation of a High Speed Permanent Magnet Synchronous Motor and Drive for a Flywheel Application at Different Frequencies

This paper presents the results of an experimental performance characterization study of a high speed, permanent magnet motor/generator (M/G) and drive applied to a flywheel module. Unlike the conventional electric machine the flywheel M/G is not a separated unit; its stator and rotor are integrated into a flywheel assembly. The M/G rotor is mounted on a flywheel rotor, which is magnetically levitated and sealed within a vacuum chamber during the operation. Thus, it is not possible to test the M/G using direct load measurements with a dynamometer and torque transducer. Accordingly, a new in-situ testing method had to be developed. The paper describes a new flywheel M/G and drive performance evaluation technique, which allows the estimation of the losses, efficiency and power quality of the flywheel high speed permanent magnet M/G, while working in vacuum, over wide frequency and torque ranges. This method does not require any hardware modification nor any special addition to the test rig. This new measurement technique is useful for high-speed applications, when applying an external load is technically difficult.

Nagorny, Aleksandr S.↗

Performance of Air-Launched T-40 Rocket Motors with Two Types of Igniter

Air-launched firings of eight T-40 rockets have been made. An average total impulse of 22,870 pound-seconds was observed for four of the rounds mounted in cone-cylinder vehicles. Maximum velocities of over 5000 feet per second were observed for two of the rounds with approximately 70-pound pay loads.

Disher, J.H.↗

Sensorimotor Adaptability Training Improves Motor and Dual-Task Performance

The overall objective of our project is to develop a sensorimotor adaptability (SA) training program designed to facilitate recovery of functional capabilities when astronauts transition to different gravitational environments. The goal of our current study was to determine if SA training using variation in visual flow and support surface motion produces improved performance in a novel sensory environment and demonstrate the retention characteristics of SA training.

Bloomberg, J.J.↗

Measurements of Ground Acoustic Environments for Small Solid Rocket Motor Firings

Mobile launcher deck and tower are exposed to severe acoustic environments during launch. These environments, if not properly managed, can weaken ground support equipment and result in structure failure. The objectives of this study were: (1) Characterize the acoustic ground environment with and without water suppression systems. (2) Validate the ground acoustic prediction based on scaling of Saturn V data. and (3) Validate a semi-empirical acoustic analysis.

Vu, Bruce↗

Space Shuttle Solid Rocket Motor Plume Pressure and Heat Rate Measurements

The Solid Rocket Booster (SRB) Main Flame Deflector (MFD) at Launch Complex 39A was instrumented with sensors to measure heat rates, pressures, and temperatures on the last three Space Shuttle launches. Because the SRB plume is hot and erosive, a robust Tungsten Piston Calorimeter was developed to compliment the measurements made by off-the-shelf sensors. Witness materials were installed and their melting and erosion response to the Mach 2 / 4500 F / 4-second duration plume was observed. The data show that the specification document used for the design of the MFD thermal protection system over-predicted heat rates by a factor of 3 and under-predicted pressures by a factor of 2. These findings will be used to baseline NASA Computational Fluid Dynamics models and develop innovative MFD designs for the Space Launch System (SLS) before this vehicle becomes operational in 2017.

vonEckroth, Wulf↗

Functional Sensory-Motor Performance Following Long Term Space Flight: The First Results of "Field Test" Experiment

The effect that extended-duration space flights may have on human space travelers, including exploration missions, is widely discussed at the present time. Specifically, there is an increasing amount of evidence showing that the physical capacity of cosmonauts is significantly reduced after long-duration space flights. It is evident that the most impaired functions are those that rely on gravity, particularly up right posture and gait. Because of the sensorimotor disturbances manifested in the neurology of the posture and gait space flight and postflight changes may also be observed in debilitating motion sickness. While the severity of particular symptoms varies, disturbances in spatial orientation and alterations in the accuracy of voluntary movements are persistently observed after long-duration space flights. At this time most of the currently available data are primarily descriptive and not yet suitable for predicting operational impacts of most sensorimotor decrements observed upon landing on planetary surfaces or asteroids. In particular there are no existing data on the recovery dynamics or functionality of neurological, cardiovascular or muscle performance making it difficult to model or simulate the cosmonauts' activity after landing and develop the appropriate countermeasure that will ensure the rapid and safe recovery of crewmembers immediately after landing in what could be hostile environments. However and as a starting position, the videos we have acquired during recent data collection following the long duration flights of cosmonauts and astronauts walking and performing other tasks shortly after return from space flight speak volumes about their level of deconditioning. A joint Russian-American team has developed a new study specifically to address the changes in crewmembers performance and the recovery of performance with the intent of filling the missing data gaps. The first (pilot) phase of this study includes recording body kinematics and quantifying the coordination and timing of relatively simple basic movements - transition from seated and prone positions to standing, walking, stepping over obstacles, tandem walking, muscle compliance, as well as characteristics of postural sway and orthostatic tolerance. Testing for changes in these parameters have been initiated in the medical tent at the landing site. The first set of experiments showed that during the first hour after landing, cosmonauts and astronauts were able to execute (although slower and with more effort than preflight) simple movements such as egress from a seated or prone position and also to remain standing for 3.5 minutes without exhibiting pronounced cardiovascular changes. More challenging tests, however, demonstrated a prominent reduction in coordination - the obstacle task, for example, was performed at much slower speed and with a marked overestimation of the obstacle height and tandem walking was greatly degraded suggesting significant changes in proprioception, brainstem and vestibular function. There is some speculation that the neural changes, either from the bottom-up or top down may be long lasting; requiring compensatory responses that will modify or mask the adverse responses we have observed. Furthermore, these compensatory responses may actually be beneficial, helping achieve a more rapid adaptation to both weightlessness and a return to earth.

Tomilovskaya, E. S.↗

Insights into the Behavior of Potential Structural Failures Originating from Localized High Stress Regions in Configurations Relevant to Solid Rocket Motor Nozzles

During the structural certification effort for the Space Launch System solid rocket booster nozzle, it was identified that no consistent method for addressing local negative margins of safety in non-metallic materials had been developed. Relevant areas included bond-line terminations and geometric features in the composite nozzle liners. In order to gain understanding, analog test specimens were designed that very closely mimic the conditions in the actual full scale hardware. Different locations in the nozzle were represented by different analog specimen designs. This paper describes those tests and corresponding results. Finite element analysis results for the tests are presented. Strain gage correlation of the analysis to the test results is addressed. Furthermore, finite fracture mechanics (a coupled stress and energy failure criterion) is utilized to predict the observed crack pop-in loads for the different configurations. The finite fracture mechanics predictions are found to be within a 10% error relative to the average measured pop-in load for each of four configurations. Initiation locations, arrest behaviors, and resistances to further post-arrest crack propagation are also discussed.

McCutcheon, David Matthew↗

Preliminary Design of the Superconducting Rotor for NASA's High-Efficiency Megawatt Motor

NASA Glenn Research Center is developing a 1.4~MW high-efficiency electric machine for future electrified aircraft to reduce energy consumption, emissions, and noise. This wound-field, synchronous machine employs a self-cooled, superconducting rotor to achieve excellent specific power and efficiency. The design of the superconducting rotor and the optimization of its electromagnetic and structural responses are analyzed in this paper. Candidate designs are evaluated in terms of absolute performance, specific performance, and performance per cost. It is found that optimizing the electromagnetic response for absolute or specific performance yields designs that are similar to each other, but opposite of the cost-optimized design. A method to define the thermal requirements of the superconducting coils and integrated cryocooler is also presented.

electric machines↗