At least 1,765 records · Page 98

Monte-Carlo analysis of rarefied-gas diffusion including variance reduction using the theory of Markov random walks

Molecular diffusion through a rarefied gas is analyzed by using the theory of Markov random walks. The Markov walk is simulated on the computer by using random numbers to find the new states from the appropriate transition probabilities. As the sample molecule during its random walk passes a scoring position, which is a location at which the macroscopic diffusing flow variables such as molecular flux and molecular density are desired, an appropriate payoff is scored. The payoff is a function of the sample molecule velocity. For example, in obtaining the molecular flux across a scoring position, the random walk payoff is the net number of times the scoring position has been crossed in the positive direction. Similarly, when the molecular density is required, the payoff is the sum of the inverse velocity of the sample molecule passing the scoring position. The macroscopic diffusing flow variables are then found from the expected payoff of the random walks.

Perlmutter, M.↗

Anisotropic picosecond photoconductivity caused by optical alignment of electron momenta in cubic semiconductors

Transient photoconductivity in cubic semiconductors InGaAs and InAs excited by a femtosecond laser pulse in the presence of a uniform dc electric field has been studied with the use of the Monte Carlo simulation by taking into account optical alignment of photoexcited electrons over their momenta. Simulations show that due to the optical alignment effect and energy dependence of the electron mobility, the transient photoconductivity in cubic semiconductors becomes anisotropic during the first few picoseconds after optical excitation. The magnitude of this anisotropy reaches its peak when the excess energy of the optically excited electrons approaches the threshold for the intervalley transfer. It has also been found that when the electrons are excited near the threshold energy for the intervalley transfer, the component of the transient photocurrent directed along the dc field for a short time after the end of the femtosecond optical pulse can become negative. The anisotropy of the transient photoconductivity has been investigated experimentally on (001) InGaAs sample by the optical pump - terahertz-probe technique. Optically induced changes in terahertz pulse amplitude were found to be dependent on the direction of terahertz field relative to the polarization of the optical pump pulse and to the crystallographic axes of the semiconductor. Experimental data have been explained in terms of the transient anisotropic photoconductivity and correlate with the results of the Monte Carlo simulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Working with Bézier Curves as bases for Functional Expansion Tallies

Functional expansion tallies (FETs) are powerful tools for getting more information per history from Monte Carlo simulations, but in the past they have been constrained to orthogonal bases. Bézier curves are used widely in computer aided design (CAD) geometry kernels and could be well-suited for FETs due to their ability to assume many arbitrary shapes, but they use nonorthogonal bases. Recent developments in 2021 have made nonorthogonal FETs possible. The convergence of Bézier curve FETs in both polynomial order and number of samples is explored in this work. It is shown that these bases are well-suited for representing normal distributions and this opens the door to the possibility of other CAD-derived FET bases.

97 - MATHEMATICS AND COMPUTING↗

30 GeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_elec_eta45_30gev

Single particle gun for detector studies: A particle gun with single electrons. One e+/e- per event. 5000 events per file. Production at (x,y,z,t)=(0,0,0,0). e+ and e- are alternated. Momentum is random from 0 to 30 GeV. Uniform distribution in Phi. Uniform distribution in the Eta (pseudorapidity) range [-4.5, 4.5]. This sample was prepared for the EIC detector studies (DIS)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraining the Beam Neutrino MC Flux Using the MINOS ND Data

This document describes a method to handle correlated systematic uncertainties from hadron production on the beam spectrum by using the neutrino ·data from the MINOS detector. We have developed a tuning function which can be applied after the fact to the Monte Carlo to force agreement with the CC neutrino energy spectra observed in the near detector and the beam MC. The method relies on the flexible NuMI beam, which can be configured so as to selectively sample pions. of different momenta and angles off the target. There is sufficient information in the neutrino data in a detector like MINOS to deduce the portion of the underlying spectrum of hadrons off the NuMI target which contribute to the NuMI flux.

Kopp, Sacha [U. Texas, Austin (main)]↗

Method of Distributions for Two‐Phase Flow in Heterogeneous Porous Media

Abstract Multiscale heterogeneity and insufficient characterization data for a specific subsurface formation of interest render predictions of multi‐phase fluid flow in geologic formations highly uncertain. Quantification of the uncertainty propagation from the geomodel to the fluid‐flow response is typically done within a probabilistic framework. This task is computationally demanding due to, for example, the slow convergence of Monte Carlo simulations (MCS), especially when computing the tails of a distribution that are necessary for risk assessment and decision‐making under uncertainty. The frozen streamlines method (FROST) accelerates probabilistic predictions of immiscible two‐phase fluid flow problems; however, FROST relies on MCS to compute the travel‐time distribution, which is then used to perform the transport (phase saturation) computations. To alleviate this computational bottleneck, we replace MCS with a deterministic equation for the cumulative distribution function (CDF) of travel time. The resulting CDF‐FROST approach yields the CDF of the saturation field without resorting to sampling‐based strategies. Our numerical experiments demonstrate the high accuracy of CDF‐FROST in computing the CDFs of both saturation and travel time. For the same accuracy, it is about 5 and 10 times faster than FROST and MCS, respectively.

Yang, Hyung Jun↗

Simulating diffusion processes in discontinuous media: A numerical scheme with constant time steps

In this article, we propose new Monte Carlo techniques for moving a diffusive particle in a discontinuous media. In this framework, we characterize the stochastic process that governs the positions of the particle. The key tool is the reduction of the process to a Skew Brownian motion (SBM). In a zone where the coefficients are locally constant on each side of the discontinuity, the new position of the particle after a constant time step is sampled from the exact distribution of the SBM process at the considered time. To do so, we propose two different but equivalent algorithms: a two-steps simulation with a stop at the discontinuity and a one-step direct simulation of the SBM dynamic. Some benchmark tests illustrate their effectiveness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Event-by-Event Simulation of Induced Fission

We are developing a novel code that treats induced fission by statistical (or Monte-Carlo) simulation of individual decay chains. After its initial excitation, the fissionable compound nucleus may either de-excite by evaporation or undergo binary fission into a large number of fission channels each with different energetics involving both energy dissipation and deformed scission pre-fragments. After separation and Coulomb acceleration, each fission fragment undergoes a succession of individual (neutron) evaporations, leading to two bound but still excited fission products (that may further decay electromagnetically and, ultimately, weakly), as well as typically several neutrons. (The inclusion of other possible ejectiles is planned.) This kind of approach makes it possible to study more detailed observables than could be addressed with previous treatments which have tended to focus on average quantities. In particular, any type of correlation observable can readily be extracted from a generated set of events. With a view towards making the code practically useful in a variety of applications, emphasis is being put on making it numerically efficient so that large event samples can be generated quickly. In its present form, the code can generate one million full events in about 12 seconds on a MacBook laptop computer. The development of this qualitatively new tool is still at an early stage and quantitative reproduction of existing data should not be expected until a number of detailed refinement have been implemented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First principles calculation of finite temperature magnetism in Fe and Fe3C

Density functional calculations have proven to be a useful tool in the study of ground state properties of many materials. The investigation of finite temperature magnetism, on the other hand, has to rely usually on the usage of empirical models that allow the large number of evaluations of the systems Hamiltonian that are required to obtain the phase space sampling needed to obtain the free energy, specific heat, magnetization, susceptibility, and other quantities as function of temperature. We have demonstrated a solution to this problem that harnesses the computational power of today s large massively parallel computers by combining a classical Wang Landau Monte-Carlo calculation [F. Wang and D. P. Landau, Phys. Rev. Lett. 86, 2050 (2001)] with our first principles multiple scattering electronic structure code [Y. Wang et al., Phys. Rev. Lett. 75, 2867 (1995)] that allows the energy calculation of constrained magnetic states [M. Eisenbach et al., Proceedings of the Conference on High Performance Computing, Networking, Storage and Analysis (ACM, New York, 2009)]. We present our calculations of finite temperature properties of Fe and Fe3C using this approach and we find the Curie temperatures to be 980 and 425K, respectively.

36 MATERIALS SCIENCE↗

Detailed high-accuracy megavoltage transmission measurements: A sensitive experimental benchmark of EGSnrc

Purpose: There are three goals for this study: (a) to perform detailed megavoltage transmission measurements in order to identify the factors that affect the measurement accuracy, (b) to use the measured data as a benchmark for the EGSnrc system in order to identify the computational limiting factors, and (c) to provide data for others to benchmark Monte Carlo codes. Methods: Transmission measurements are performed at the National Research Council Canada on a research linac whose incident electron parameters are independently known. Automated transmission measurements are made on-axis, down to a transmission value of {approx}1.7%, for eight beams between 10 MV (the lowest stable MV beam on the linac) and 30 MV, using fully stopping Be, Al, and Pb bremsstrahlung targets and no fattening filters. To diversify energy differentiation, data are acquired for each beam using low-Z and high-Z attenuators (C and Pb) and Farmer chambers with low-Z and high-Z buildup caps. Experimental corrections are applied for beam drifts (2%), polarity (2.5% typical maximum, 6% extreme), ion recombination (0.2%), leakage (0.3%), and room scatter (0.8%)-the values in parentheses are the largest corrections applied. The experimental setup and the detectors are modeled using EGSnrc, with the newly added photonuclear attenuation included (up to a 5.6% effect). A detailed sensitivity analysis is carried out for the measured and calculated transmission data. Results: The developed experimental protocol allows for transmission measurements with 0.4% uncertainty on the smallest signals. Suggestions for accurate transmission measurements are provided. Measurements and EGSnrc calculations agree typically within 0.2% for the sensitivity of the transmission values to the detector details, to the bremsstrahlung target material, and to the incident electron energy. Direct comparison of the measured and calculated transmission data shows agreement better than 2% for C (3.4% for the 10 MV beam) and typically better than 1% for Pb. The differences can be explained by acceptable photon cross section changes of Less-Than-Or-Slanted-Equal-To 0.4%. Conclusions: Accurate transmission measurements require accounting for a number of influence quantities which, if ignored, can collectively introduce errors larger than 10%. Accurate transmission calculations require the use of the most accurate data and physics options available in EGSnrc, particularly the more accurate bremsstrahlung angular sampling option and the newly added modeling of photonuclear attenuation. Comparison between measurements and calculations implies that EGSnrc is accurate within 0.2% for relative ion chamber response calculations. Photon cross section uncertainties are the ultimate limiting factor for the accuracy of the calculated transmission data (Monte Carlo or analytical).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculating uncertainty on K-effective with MONK10 - 14583

Criticality safety assessments require a demonstration that a particular configuration of fissile material has an adequate sub-critical margin (k-effective sufficiently below unity) to ensure that the risk of criticality under normal operation and accident conditions is acceptable. The required sub-critical margin depends upon the uncertainty in the estimated value of k-effective. The uncertainty in the calculated value of k-effective arises from a number of sources, including: manufacturing tolerances on input data to the code (affecting geometry, compositions and densities), uncertainty in the nuclear data used by the code, stochastic uncertainty resulting from Monte Carlo simulation and modelling approximations/errors, including the inevitable bugs in the software. The ANSWERS Software Service, in collaboration with industrial partners, is developing a number of techniques to better understand and quantify uncertainty on predicted values of k-effective, using MONK. The SPRUCE utility code has been developed to allow uncertainty to be estimated using sampling methods. This can include the sampling of input parameters (including dimensions, compositions and densities) from statistical distributions. It can also include sampling different nuclear data libraries. A set of nuclear data libraries has been generated for this purpose by sampling from statistical distributions that represent the uncertainties in the published nuclear data evaluated files; a set of libraries has been produced for Latin Hypercube Sampling. By varying the input data and nuclear data, separate and combined uncertainties due to manufacturing tolerances and nuclear data can be derived. By performing least squares fitting on the results it is also possible to estimate the contribution of each of the uncertain inputs and a sensitivity method in MONK can break down the nuclear data uncertainty. (authors)

42 ENGINEERING↗

THE FAINT END OF THE QUASAR LUMINOSITY FUNCTION AT z {approx} 4

The evolution of the quasar luminosity function (QLF) is one of the basic cosmological measures providing insight into structure formation and mass assembly in the universe. We have conducted a spectroscopic survey to find faint quasars (-26.0 < M{sub 1450} < -22.0) at redshifts z = 3.8-5.2 in order to measure the faint end of the QLF at these early times. Using available optical imaging data from portions of the NOAO Deep Wide-Field Survey and the Deep Lens Survey, we have color-selected quasar candidates in a total area of 3.76 deg{sup 2}. Thirty candidates have R <= 23 mag. We conducted spectroscopic follow-up for 28 of our candidates and found 23 QSOs, 21 of which are reported here for the first time, in the 3.74 < z < 5.06 redshift range. We estimate our survey completeness through detailed Monte Carlo simulations and derive the first measurement of the density of quasars in this magnitude and redshift interval. We find that the binned luminosity function (LF) is somewhat affected by the K-correction used to compute the rest-frame absolute magnitude at 1450 A. Considering only our R <= 23 sample, the best-fit single power law (PHI {proportional_to} L {sup beta}) gives a faint-end slope beta = -1.6 +- 0.2. If we consider our larger, but highly incomplete sample going 1 mag fainter, we measure a steeper faint-end slope -2 < beta < -2.5. In all cases, we consistently find faint-end slopes that are steeper than expected based on measurements at z {approx} 3. We combine our sample with bright quasars from the Sloan Digital Sky Survey to derive parameters for a double-power-law LF. Our best fit finds a bright-end slope, alpha = -2.4 +- 0.2, and faint-end slope, beta = -2.3 +- 0.2, without a well-constrained break luminosity. This is effectively a single power law, with beta = -2.7 +- 0.1. We use these results to place limits on the amount of ultraviolet radiation produced by quasars and find that quasars are able to ionize the intergalactic medium at these redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of hadronic event-shape variables in multijet final states in pp collisions at √s = 7 TeV

Event-shape variables, which are sensitive to perturbative and nonperturbative aspects of quantum chromodynamic (QCD) interactions, are studied in multijet events recorded in proton-proton collisions at √s = 7 TeV. Events are selected with at least one jet with transverse momentum p T > 110 GeV and pseudorapidity |η| < 2.4, in a data sample corresponding to integrated luminosities of up to 5 fb –1 . As a result, the distributions of five event-shape variables in various leading jet p T ranges are compared to predictions from different QCD Monte Carlo event generators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Construction of A Cerenkov Counter for In Situ Monitoring of Sr-90 in Groundwater

Migration of groundwater contamination from beneath the U.S. Department of Energy’s Hanford Site into the Columbia River creates a need for in situ 90Sr monitoring. The prototype monitor discussed here is designed for deployment inside a monitoring well and provides near-real-time determination of the 90Sr concentration in a two-liter groundwater sample. The measurement is made by direct detection of Cerenkov light generated in the water by beta decay of the 90Y daughter. This manuscript presents results from a prototype monitor that was designed by a parametric Monte Carlo simulation study. Calibration and testing results of the as-built system show near perfect agreement between simulated predictions and experimental results. Downwell and laboratory tests demonstrate that the prototype monitor is sensitive to 90Sr at concentrations below drinking water standards of 8 pCi/l (0.3 Bq/l) at the 90% confidence level in measurement times of less than four hours.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectroscopic and neutron detection properties of rare earth and titanium doped LiAlO 2 single crystals

In this study, LiAlO2 crystals doped with rare-earth elements and Ti were produced by the CZ method and spectroscopic and neutron detection properties were investigated. Photoluminescence revealed no clear luminescent activation of LiAlO2 by the rare-earth dopants though some interesting luminescence was observed from secondary phases within the crystal. Gamma-ray pulse height spectra collected using a 137Cs source exhibited only a Compton edge for the crystals. Neutron modeling using Monte Carlo N-Particle Transport Code revealed most neutrons used in the detection setup are thermalized, and while using natural lithium in the crystal growth, which contains 7.6 % 6Li, a 10 mm Ø by 10 mm sample of LiAlO2 has a 70.7 % intrinsic thermal neutron capture efficiency. Furthermore, the pulse height spectra collected using a 241Am-Be neutron source demonstrated a distinct neutron peak.

Dickens, Peter T.↗

The Tynode: A new vacuum electron multiplier

By placing, in vacuum, a stack of transmission dynodes (tynodes) on top of a CMOS pixel chip, a single free electron detector could be made with outstanding performance in terms of spatial and time resolution. The essential object is the tynode: an ultra thin membrane, which emits, at the impact of an energetic electron on one side, a multiple of electrons at the other side. The electron yields of tynodes have been calculated by means of GEANT-4 Monte Carlo simulations, applying special low-energy extensions. The results are in line with another simulation based on a continuous charge-diffusion model. By means of Micro Electro Mechanical System (MEMS) technology, tynodes and test samples have been realized. The secondary electron yield of several samples has been measured in three different setups. Finally, several possibilities to improve the yield are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Instrument performance study on the short and long pulse options of the second Spallation Neutron Source target station

The Spallation Neutron Source (SNS) facility at the Oak Ridge National Laboratory is designed with an upgrade option for a future low repetition rate, long wavelength second target station. This second target station is intended to complement the scientific capabilities of the 1.4 MW, 60 Hz high power first target station. Two upgrade possibilities have been considered, the short and the long pulse options. In the short pulse mode, proton extraction occurs after the pulse compression in the accumulator ring. The proton pulse structure is thus the same as that for the first target station with a pulse width of ∼0.7 μs. In the long pulse mode, protons are extracted as they are produced by the linac, with no compression in the accumulator ring. The time width of the uncompressed proton pulse is ∼1 ms. This difference in proton pulse structure means that neutron pulses will also be different. Neutron scattering instruments thus have to be designed and optimized very differently for these two source options which will directly impact the overall scientific capabilities of the SNS facility. In order to assess the merits of the short and long pulse target stations, we investigated a representative suit of neutron scattering instruments and evaluated their performance under each option. Our results indicate that the short pulse option will offer significantly better performance for the instruments and is the preferred choice for the SNS facility.

43 PARTICLE ACCELERATORS↗