Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mobile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

A First-Order Estimate of Automated Mobility District Fuel Consumption and GHG Emission Impacts

A first of its kind, this study develops a framework to quantify the fuel consumption and greenhouse gas emission impacts of an Automated Small Vehicle Transit system on a campus area. The results show that the automated mobility district system has the potential to reduce transportation system fuel consumption and greenhouse gas emissions, but the benefits are largely dependent on the operation and ridership of the personal rapid transit system. Our study calls for more research to understand the energy and environmental benefits of such a system.

33 ADVANCED PROPULSION SYSTEMS↗

Sensing Few Electrons Floating on Helium with High-Electron-Mobility Transistors

We report on low-frequency measurements of few electrons floating on superfluid helium using a bespoke cryogenic cascode amplifier circuit built with off-the-shelf GaAs high-electron-mobility transistors (HEMTs). We integrate this circuit with a charge-coupled device (CCD) to transport the electrons on helium and characterize its performance. Here, we show that this circuit has a signal-to-noise ratio (SNR) of ~ 2 $\frac{e}{√Hz}$ at 102 kHz, an order of magnitude improvement from previous implementations, and provides a compelling alternative to few electron sensing with high-frequency resonators.

Charge-Coupled Devices↗

Determining the Impact of Personal Mobility Carbon Allowance Schemes in Transportation Networks

We know that personal mobility carbon allowance (PMCA) schemes are designed to reduce carbon consumption from transportation networks. PMCA schemes influence the travel decision process of users and accordingly impact the system metrics including travel time and greenhouse gas (GHG) emissions. Here, we develop a multi-user class dynamic user equilibrium model to evaluate the transportation system performance when PMCA scheme is implemented. The results using Sioux-Falls test network indicate that PMCA schemes can achieve the emissions reduction goals for transportation networks. Further, users characterized by high value of travel time are found to be less sensitive to carbon budget in the context of work trips. Results also show that PMCA scheme can lead to higher emissions for a path compared with the case without PMCA because of flow redistribution. The developed network equilibrium model allows us to examine the change in system states at different carbon allocation levels and to design parameters of PMCA schemes accounting for population heterogeneity.

54 ENVIRONMENTAL SCIENCES↗

Separation and Classification of Lipids Using Differential Ion Mobility Spectrometry

Correlations between the dimensions of a 2-D separation create trend lines that normally depend on structural or functional characteristics of the compound class and thus facilitate classification of unknowns. This broadly applies to conventional ion mobility spectrometry (IMS)/mass spectrometry (MS), where the major biomolecular classes (e.g., lipids, peptides, nucleotides) occupy different trend line domains. However, strong correlation between the IMS and MS separations for ions of same charge has impeded finer distinctions. Differential IMS (or FAIMS) is generally much less correlated to MS and thus should better separate the trend lines and associated domains. We report the first observation of chemical class separation by trend lines using FAIMS, here for lipids. For all lipids, FAIMS is indeed more independent of MS than conventional IMS, and subclasses (such as phospho-, glycero-, or sphingolipids) form distinct, often non-overlapping domains. Even finer categories with different functional groups or degrees of unsaturation are often separated. As expected, resolution improves in He-rich gases: at ~70% He, glycerolipid isomers with different positions of fatty acid attachment can be resolved. These results open the door for lipidomics application of FAIMS, particularly shotgun lipidomics and targeted analyses of bioactive lipids.

99 GENERAL AND MISCELLANEOUS↗

Detecting and Removing Data Artifacts in Hadamard Transform Ion Mobility-Mass Spectrometry Measurements

Applying Hadamard transform multiplexing to ion mobility separations (IMS) can significantly improve the signal-to-noise ratio and throughput for IMS coupled mass spectrometry (MS) measurements by increasing the ion utilization efficiency. However, it has been determined that both fluctuations in ion intensity as well as spatial shifts in the multiplexed data lower the signal-to-noise ratios and appear as noise in downstream processing of the data. To address this problem, we have developed a novel algorithm that discovers and eliminates data artifacts. The algorithm uses knowledge of the true signal peaks derived from the encoded data and allows for both artifacts and noise to be removed with high confidence, decreasing the likelihood of false identifications in subsequent data processing. The result is that IMS-MS can be applied to increase measurement sensitivity while avoiding artifacts that have previously limited its utility.

47 OTHER INSTRUMENTATION↗

Comprehensive Gas-Phase Peptide Ion Structure Studies Using Ion Mobility Techniques: Part 2. Gas-Phase Hydrogen/Deuterium Exchange for Ion Population Estimation

Gas-phase hydrogen/deuterium exchange (HDX) using D{sub 2}O reagent and collision cross-section (CCS) measurements are utilized to monitor the ion conformers of the model peptide acetyl-PAAAAKAAAAKAAAAKAAAAK. The measurements are carried out on a home-built ion mobility instrument coupled to a linear ion trap mass spectrometer containing electron transfer dissociation (ETD) capabilities. ETD is utilized to obtain per-residue deuterium uptake data for select ion conformers, and a new algorithm is presented for interpreting the HDX data. Using molecular dynamics (MD) production data and a hydrogen accessibility scoring (HAS)-number of effective collisions (NEC) model, hypothetical HDX behavior is attributed to various in-silico candidate (CCS match) structures. The HAS-NEC model is applied to all candidate structures, and non-negative linear regression is employed to determine structure contributions resulting in the best match to deuterium uptake. The accuracy of the HAS-NEC model is tested with the comparison of predicted and experimental isotopic envelopes for several of the observed c-ions. It is proposed that gas-phase HDX can be utilized effectively as a second criterion (after CCS matching) for filtering suitable MD candidate structures. In this study, the second step of structure elucidation, 13 nominal structures were selected (from a pool of 300 candidate structures) and each with a population contribution proposed for these ions. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differential Mobility Spectrometry for Improved Selectivity in Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry Analysis of Paralytic Shellfish Toxins

Paralytic shellfish toxins (PSTs) are neurotoxins produced by dinoflagellates and cyanobacteria that cause paralytic shellfish poisoning in humans. PST quantitation by LC-MS is challenging because of their high polarity, lability as gas-phase ions, and large number of potentially interfering analogues. Differential mobility spectrometry (DMS) has the potential to improve the performance of LC-MS methods for PSTs in terms of selectivity and limits of detection. This work describes a comprehensive investigation of the separation of 16 regulated PSTs by DMS and the development of highly selective LC-DMS-MS methods for PST quantitation. The effects of all DMS parameters on the separation of PSTs from one another were first investigated in detail. The labile nature of 11α-gonyautoxin epimers gave unique insight into fragmentation of labile analytes before, during, and after the DMS analyzer. Two sets of DMS parameters were identified that either optimized the resolution of PSTs from one another or transmitted them at a limited number of compensation voltage (CV) values corresponding to structural subclasses. These were used to develop multidimensional LC-DMS-MS/MS methods using existing HILIC-MS/MS parameters. In both cases, improved selectivity was observed when using DMS, and the quantitative capabilities of a rapid UPLC-DMS-MS/MS method were evaluated. Limits of detection of the developed method were similar to those without DMS, and differences were highly analyte-dependant. Analysis of shellfish matrix reference materials showed good agreement with established methods. The developed methods will be useful in cases where specific matrix interferences are encountered in the LC-MS/MS analysis of PSTs in complex biological samples. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmark Comparison for a Multi-Processing Ion Mobility Calculator in the Free Molecular Regime

A benchmark comparison between two ion mobility and collision cross-section (CCS) calculators, MOBCAL and IMoS, is presented here as a standard to test the efficiency and performance of both programs. Utilizing 47 organic ions, results are in excellent agreement between IMoS and MOBCAL in He and N{sub 2,} when both programs use identical input parameters. Due to a more efficiently written algorithm and to its parallelization, IMoS is able to calculate the same CCS (within 1%) with a speed around two orders of magnitude faster than its MOBCAL counterpart when seven cores are used. Due to the high computational cost of MOBCAL in N{sub 2}, reaching tens of thousands of seconds even for small ions, the comparison between IMoS and MOBCAL is stopped at 70 atoms. Large biomolecules (>10000 atoms) remain computationally expensive when IMoS is used in N{sub 2} (even when employing 16 cores). Approximations such as diffuse trajectory methods (DHSS, TDHSS) with and without partial charges and projected area approximation corrections can be used to reduce the total computational time by several folds without hurting the accuracy of the solution. These latter methods can in principle be used with coarse-grained model structures and should yield acceptable CCS results. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion Mobility Spectrometry - High Resolution LTQ-Orbitrap Mass Spectrometry for Analysis of Homemade Explosives

The detailed chemical characterization of homemade explosives (HMEs) and other chemicals that can mimic or mask the presence of explosives is important for understanding and improving the performance of commercial instrumentation used for explosive detection. To that end, an atmospheric-pressure drift tube ion mobility spectrometry (IMS) instrument has been successfully coupled to a commercial tandem mass spectrometry (MS) system. The tandem MS system is comprised of a linear ion trap and a high resolution Orbitrap analyzer. This IMS-MS combination allows extensive characterization of threat chemical compounds, including HMEs, and complex real-world background chemicals that can interfere with detection. Here, the composition of ion species originating from a specific HME, erythritol tetranitrate, has been elucidated using accurate mass measurements, isotopic ratios, and tandem MS. Gated IMS-MS and high-resolution MS have been used to identify minor impurities that can be indicative of the HME source and/or synthesis route. Comparison between data obtained on the IMS/MS system and on commercial stand-alone IMS instruments used as explosive trace detectors (ETDs) has also been performed. Such analysis allows better signature assignments of threat compounds, modified detection algorithms, and improved overall ETD performance. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broad Separation of Isomeric Lipids by High-Resolution Differential Ion Mobility Spectrometry with Tandem Mass Spectrometry

Maturation of metabolomics has brought a deeper appreciation for the importance of isomeric identity of lipids to their biological role, mirroring that for proteoforms in proteomics. However, full characterization of the lipid isomerism has been thwarted by paucity of rapid and effective analytical tools. A novel approach is ion mobility spectrometry (IMS) and particularly differential or field asymmetric waveform IMS (FAIMS) at high electric fields, which is more orthogonal to mass spectrometry. Here we broadly explore the power of FAIMS to separate lipid isomers, and find a ~75% success rate across the four major types of glycero- and phospho- lipids (sn, chain length, double bond position, and cis/trans). The resolved isomers were identified using standards, and (for the first two types) tandem mass spectrometry. These results demonstrate the general merit of incorporating high-resolution FAIMS into lipidomic analyses. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coming to Grips with Ambiguity: Ion Mobility-Mass Spectrometry for Protein Quaternary Structure Assignment

Multiprotein complexes are central to our understanding of cellular biology, as they play critical roles in nearly every biological process. Despite many impressive advances associated with structural characterization techniques, large and highly-dynamic protein complexes are too often refractory to analysis by conventional, high-resolution approaches. To fill this gap, ion mobility-mass spectrometry (IM-MS) methods have emerged as a promising approach for characterizing the structures of challenging assemblies due in large part to the ability of these methods to characterize the composition, connectivity, and topology of large, labile complexes. In this Critical Insight, we present a series of bioinformatics studies aimed at assessing the information content of IM-MS datasets for building models of multiprotein structure. Our computational data highlights the limits of current coarse-graining approaches, and compelled us to develop an improved workflow for multiprotein topology modeling, which we benchmark against a subset of the multiprotein complexes within the PDB. This improved workflow has allowed us to ascertain both the minimal experimental restraint sets required for generation of high-confidence multiprotein topologies, and quantify the ambiguity in models where insufficient IM-MS information is available. We conclude by projecting the future of IM-MS in the context of protein quaternary structure assignment, where we predict that a more complete knowledge of the ultimate information content and ambiguity within such models will undoubtedly lead to applications for a broader array of challenging biomolecular assemblies. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polymers for Traveling Wave Ion Mobility Spectrometry Calibration

One of the main issues when using traveling wave ion mobility spectrometry (TWIMS) for the determination of collisional cross-section (CCS) concerns the need for a robust calibration procedure built from referent ions of known CCS. Here, we implement synthetic polymer ions as CCS calibrants in positive ion mode. Based on their intrinsic polydispersities, polymers offer in a single sample the opportunity to generate, upon electrospray ionization, numerous ions covering a broad mass range and a large CCS window for different charge states at a time. In addition, the key advantage of polymer ions as CCS calibrants lies in the robustness of their gas-phase structure with respect to the instrumental conditions, making them less prone to collisional-induced unfolding (CIU) than protein ions. In this paper, we present a CCS calibration procedure using sodium cationized polylactide and polyethylene glycol, PLA and PEG, as calibrants with reference CCS determined on a home-made drift tube. Our calibration procedure is further validated by testing the polymer calibration to determine CCS of numerous different ions for which CCS are reported in the literature. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Native Mass Spectrometry, Ion mobility, and Collision-Induced Unfolding Categorize Malaria Antigen/Antibody Binding

Plasmodium vivax Duffy Binding Protein (PvDBP) is a promising vaccine candidate for P. vivax malaria. Recently, we reported the epitopes on PvDBP region II (PvDBP-II) for three inhibitory monoclonal antibodies (2D10, 2H2, and 2C6). In this communication, we describe the combination of native mass spectrometry and ion mobility (IM) with collision induced unfolding (CIU) to study the conformation and stabilities of three malarial antigen–antibody complexes. These complexes, when collisionally activated, undergo conformational changes that depend on the location of the epitope. CIU patterns for PvDBP-II in complex with antibody 2D10 and 2H2 are highly similar, indicating comparable binding topology and stability. A different CIU fingerprint is observed for PvDBP-II/2C6, indicating that 2C6 binds to PvDBP-II on an epitope different from 2D10 and 2H2. This work supports the use of CIU as a means of classifying antigen-antibody complexes by their epitope maps in a high throughput screening workflow. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flying Cages in Traveling Wave Ion Mobility: Influence of the Instrumental Parameters on the Topology of the Host–Guest Complexes

Supramolecular mass spectrometry has emerged in the last decade as an orthogonal method to access, at the molecular level, the structures of noncovalent complexes extracted from the condensed phase to the rarefied gas phase using electrospray ionization. It is often considered that the soft nature of the ESI source confers to the method the capability to generate structural data comparable to those in the condensed phase. In the present paper, using the ammonium ion/cucurbituril combination as a model system, we investigate using ion mobility and computational chemistry the influence of the instrumental parameters on the topology, i.e., internal versus external association, of gaseous host/guest complex ions. MS and theoretical data are confronted to condensed phase data derived from nuclear magnetic resonance spectroscopy to assess whether the instrumental parameters can play an insidious role when trying to derive condensed phase data from mass spectrometry results. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining the Effect of Catechins on SOD1 Conformation and Aggregation by Ion Mobility Mass Spectrometry Combined with Optical Spectroscopy

The aggregation of Cu,Zn-superoxide dismutase (SOD1) plays an important role in the etiology of amyotrophic lateral sclerosis (ALS). For the disruption of ALS progression, discovering new drugs or compounds that can prevent SOD1 aggregation is important. In this study, ESI-MS was used to investigate the interaction of catechins and SOD1. The noncovalent complex of catechins that interact with SOD1 was found and retained in the gas phase under native ESI-MS condition. The conformation changes of SOD1 after binding with catechins were also explored via traveling wave ion mobility (IM) spectrometry. Epigallocatechin gallate (EGCG) can stabilize SOD1 conformation against unfolding in three catechins. To further evaluate the efficacy of EGCG, we monitored the fluorescence changes of dimer E{sub 2},E{sub 2},-SOD1(apo-SOD1, E:empty) with and without ligands under denaturation conditions, and found that EGCG can inhibit apo-SOD1 aggregation. In addition, the circular dichroism spectra of the samples showed that EGCG can decrease the β-sheet content of SOD1, which can produce aggregates. These results indicated that orthogonal separation dimension in the gas-phase IM coupled with ESI-MS (ESI-IM-MS) can potentially provide insight into the interaction between SOD1 and small molecules. The advantage is that it dramatically decreases the analysis time. Meantime, optical spectroscopy techniques can be used to confirm ESI-IM-MS results. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Traveling Wave Ion Mobility Spectrometry (TWIMS) Study of the Robo1-Heparan Sulfate Interaction

Roundabout 1 (Robo1) interacts with its receptor Slit to regulate axon guidance, axon branching, and dendritic development in the nervous system and to regulate morphogenesis and many cell functions in the nonneuronal tissues. This interaction is known to be critically regulated by heparan sulfate (HS). Previous studies suggest that HS is required to promote the binding of Robo1 to Slit to form the minimal signaling complex, but the molecular details and the structural requirements of HS for this interaction are still unclear. Here, we describe the application of traveling wave ion mobility spectrometry (TWIMS) to study the conformational details of the Robo1-HS interaction. The results suggest that Robo1 exists in two conformations that differ by their compactness and capability to interact with HS. The results also suggest that the highly flexible interdomain hinge region connecting the Ig1 and Ig2 domains of Robo1 plays an important functional role in promoting the Robo1-Slit interaction. Moreover, variations in the sulfation pattern and size of HS were found to affect its binding affinity and selectivity to interact with different conformations of Robo1. Both MS measurements and CIU experiments show that the Robo1-HS interaction requires the presence of a specific size and pattern of modification of HS. Furthermore, the effect of N-glycosylation on the conformation of Robo1 and its binding modes with HS is reported. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion Mobility Measurements of Multianionic Metalloporphyrin Dimers: Structural Changes Induced by Countercation Exchange

We present gas-phase structures of dimers of Mn{sup III} and Fe{sup III} meso-tetra(4-sulfonatophenyl)porphyrin multianions with various amounts of sodium and hydrogen counterions. The structural assignments are achieved by combining mass spectrometry, ion mobility measurements, quantum chemical calculations, and trajectory method collision cross section calculations. For a common charge state, we observe significant topological variations in the dimer structures of [(MTPPS){sub 2}+nX]{sup (6-n)-} (M=Mn{sup III}, Fe{sup III}; X=H, Na; n = 1–3) induced by replacing hydrogen counterions by sodium. For sodium, the dimer structures are much more compact, a finding that can be rationalized by the stronger interactions of the sodium cations with the anionic sulfonic acid groups of the porphyrins as compared to hydrogen. .

74 ATOMIC AND MOLECULAR PHYSICS↗