Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Multiple-orifice liquid injection into hypersonic airstreams and applications to ram C-3 flight

Experimental data are presented for the oblique injection of water and three electrophilic liquids (fluorocarbon compounds) through multiple-orifice nozzles from a flat plate and the sides of a hemisphere-cone (0.375 scale of RAM C spacecraft) into hypersonic airstreams. The nozzle patterns included single and multiple orifices, single rows of nozzles, and duplicates of the RAM C-III nozzles. The flat-plate tests were made at Mach 8. Total pressure was varied from 3.45 MN/m2 to 10.34 MN/m2, Reynolds number was varied form 9,840,000 per meter to 19,700,000 per meter, and liquid injection pressure was varied from 0.69 MN/m2 to 3.5 MN/m2. The hemisphere-cone tests were made at Mach 7.3. Total pressure was varied from 1.38 MN/m2, to 6.89 MN/m2, Reynolds number was varied from 3,540,000 per meter to 17,700,000 per meter, and liquid-injection pressure was varied from 0.34 MN/m2 to 4.14 MN/m2. Photographs of the tests and plots of liquid-penetration and spray cross-section area are presented. Maximum penetration was found to vary as the square root of the dynamic-pressure ratio and the square root of the total injection nozzle area. Spray cross-section area was linear with maximum penetration. The test results are used to compute injection parameters for the RAM C-3 flight injection experiment.

Weaver, W. L.↗

High-temperature strength of refractory-metal wires and consideration for composite applications

Tensile and stress-rupture tests were conducted on wires of W-Hf-C, W-Re-Hf-C, ASTAR 811C (a tantalum alloy), and B-88 (a columbium alloy) at room temperature, 1093 C (2000 F), and 1204 C (2200 F). Metallographic examinations were also made of the wire microstructure after testing. Ultimate tensile strength values up to 2170 meganewtons per square meter (314000 psi) at 1093 C (2000 F) and 1940 meganewtons per square meter (281 000 psi) at 1204 C (2200 F) were obtained for W-Re-Hf-C wire. The best strength values obtained for a 100-hour rupture life were, 1410 meganewtons per square meter (205 000 psi) at 1093 C (2000 F) and 910 meganewtons per square meter (132 000 psi) at 1240 C (2200 F) for W-Re-Hf-C wire. The properties obtained suggested that the wires studied showed promise as potential fiber reinforcement in the 1093 to 1204 C (2000 to 2200 F) temperature range.

Petrasek, D. W.↗

Apollo 15 main-parachute failure

In the investigation of the failure of one of the three main parachutes of the Apollo 15 spacecraft, which collapsed at approximately 1825 meters after operating properly from deployment at 3050 meters, three conditions considered to be possible causes of the failure were produced. The suspect conditions were the proximity of the forward heat shield that passed the spacecraft at approximately 1825 meters, the dumping of the reaction control system hypergolic propellants at approximately 1825 meters, and the failing of a riser link found on a recovered parachute. (The failed parachute was not recovered). The remaining two parachutes functioned as planned and averted a catastrophic failure. The conclusions concerning the cause of the failure are discussed.

Arabian, D. D.↗

Flight investigation of XB-70 structural response to oscillatory aerodynamic shaker excitation and correlation with analytical results

The low frequency symmetric structural response and damping characteristics of the XB-70 airplane were measured at four flight conditions: heavyweight at a Mach number of 0.87 at an altitude of 7620 meters (25,000 feet); lightweight at a Mach number of 0.86 at an altitude of 7620 meters (25,000 feet); a Mach number of 1.59 at an altitude of 11,918 meters (39.100 feet); and a Mach number of 2.38 and an altitude of 18,898 meters (62,000 feet). The flight data are compared with the response calculated by using early XB-70 design data and with the response calculated with mass, structural, and aerodynamic data updated to reflect as closely as possible the airplane characteristics at three of the flight conditions actually flown.

Mckay, J. M.↗

A one way Doppler tracking system for satellite to satellite tracking

An S-band tracking system employing one way Doppler applicable to the tracking and data relay system (TDRS) was evaluated. This evaluation is limited to the measurement system parameters. The analysis assumes state-of-the-art components such as spacecraft oscillator long term stability of one part in 10 to the 8th power and ground station oscillator stability of one part in 10 to the 11th power. Signal characteristics comparable with the present ranging systems are utilized in the analysis. Predicated upon measurement system parameters, position uncertainties for the low orbiting spacecraft vary from 5 meters to 2 kilometers along track, 4 meters to 1 kilometer cross track, and 1 meter to 180 meters radially depending upon the tracking geometry and the high satellite position and velocity error assumptions.

Bryan, J. W.↗

Evaluation of ERTS data for certain oceanographic uses

The author has identified the following significant results. According to Lake Michigan records, the pH levels have been steadily increasing as the lake becomes more eutrophic. Numerous upwellings during the summer of 1973, beginning with the late July event, appear to be triggering a chemical precipitation of calcium carbonate. The upwelling provides abundant carbon dioxide into the surface water and results in massive blooms of phytoplankton. As the CO2 is utilized by these microscopic plants the pH is increased (acidity decreases) and CaCO3 no longer is able to remain in solution. The precipitation takes place where the phytoplankton are living, near depths of 10 meters. Therefore, the whiting observed by ERTS-1 is only seen in the green band, as red cannot penetrate but a few meters. With these whitings, secci disc readings lower in July from 10-15 meters to 3-5 meters and green, milky water is observed by research vessels. It appears that whitings have been becoming more frequent since the middle 60's but until ERTS-1 the extent had never been realized. Calcium levels are too low, presently, for a similar precipitate in Lakes Huron or Superior. However, whitings have been seen by ERTS-1 in Lakes Erie and Ontario where the calcium ion and pH levels are more like those found in Lake Michigan.

Strong, A. E.↗

Gravimetric geodesy and sea surface topography studies by means of satellite-to-satellite tracking and satellite altimetry

A satellite-to-satellite tracking experiment is planned between ATS-F and GEOS-C with a range accuracy of 2-meters and a range rate accuracy of 0.035 centimeters per second for a 10-second integration time. This experiment is planned for 1974. It is anticipated that it will improve the spatial resolution of the satellite geoid by half an order of magnitude to about 6 degrees. Longer integration times should also permit a modest increase in the acceleration resolution. Satellite altimeter data will also be obtained by means of GEOS-C. An overall accuracy of 5-meters in altitude is the goal. The altimeter, per se, is expected to have an instrumental precision of about 2 meters, and an additional capability to observe with a precision of about 0.2 meters for limited periods.

Siry, J. W.↗

Global detailed geoid computation and model analysis

Comparisons and analyses were carried out through the use of detailed gravimetric geoids which we have computed by combining models with a set of 26,000 1 deg x 1 deg mean free air gravity anomalies. The accuracy of the detailed gravimetric geoid computed using the most recent Goddard earth model (GEM-6) in conjunction with the set of 1 deg x 1 deg mean free air gravity anomalies is assessed at + or - 2 meters on the continents of North America, Europe, and Australia, 2 to 5 meters in the Northeast Pacific and North Atlantic areas, and 5 to 10 meters in other areas where surface gravity data are sparse. The R.M.S. differences between this detailed geoid and the detailed geoids computed using the other satellite gravity fields in conjuction with same set of surface data range from 3 to 7 meters.

Marsh, J. G.↗

Results of the long range position-determining system tests

The long range position-determining system (LRPDS) has been developed by the Corps of Engineers to provide the Field Army with a rapid and accurate positioning capability. The LRPDS consists of an airborne reference position set (RPS), up to 30 ground based positioning sets (PS), and a position computing central (PCC). The PCC calculates the position of each PS based on the range change information provided by each Set. The positions can be relayed back to the PS again via RPS. Each PS unit contains a double oven precise crystal oscillator. The RPS contains a Hewlett-Packard cesium beam standard. Frequency drifts and off-sets of the crystal oscillators are taken in account in the data reduction process. A field test program was initiated in November 1972. A total of 54 flights were made which included six flights for equipment testing and 48 flights utilizing the field test data reduction program. The four general types of PS layouts used were: short range; medium range; long range; tactical configuration. The overall RMS radial error of the unknown positions varied from about 2.3 meters for the short range to about 15 meters for the long range. The corresponding elevation RMS errors vary from about 12 meters to 37 meters.

Rhode, F. W.↗

Results of the 3 November 1974 Applications Technology Satellite-6 (ATS-6) trilateration test

The highly successful 24 hour trilateration tracking and orbit determination test conducted on 3 November 1974 is described. In this test a new method of accurately computing geostationary spacecraft orbits was applied to the Applications Technology Satellite (ats-6). A single tracking station interrogates several strategically deployed ground based transponders via the synchronous satellite whose orbit is to be determined. The ATS-6 tracking data measurement noise over the 24 hour period was observed to be 0.3 mm/sec in range rate and 1.5 meters in range. By means of overlap orbit computation using 2 separate tracking data bases, the ATS-6 total position and velocity uncertainties were determined to reach a minimum of 30 meters and 0.2 cm/sec respectively. The maximum position and velocity uncertainty over this same time period was determined to be approximately 250 meters and 2 cm/sec respectively. A position determination using simultaneous tracking of the NASA-GSFC site by ATS-6 and ATS-3 was also performed. Station location recovery was to an accuracy on the order of 100 meters over the first 10 hours of tracking.

Schmid, P. E.↗

Preliminary results from screening tests of commercial catalysts with potential use in gas turbine combustors. Part 2: Combustion test rig evaluation

Several commercial monolithic catalysts were tested in a combustion test rig to determine their suitability for use in a gas turbine combuster primary zone. The catalyst test bed consisted of two to four elements of 12-centimeter diameter by 2.5-centimeter long monolith. Results are presented of the measured combustion efficiency and catalyst bed temperature history for an inlet propane-air mixture temperature of 800 K, a pressure of 300,000 newtons per square meter, inlet velocities of 10 to 25 meters per second and equivalence ratios of 0.1 to 0.3. The best catalysts tested gave combustion efficiencies of virtually 100 percent for reaction temperatures ranging from 1,325 K at 10 meters per second to 1,400 K at 25 meters per second. This performance was only possible with fresh catalysts. The catalysts tested were not specifically developed for use at these conditions and showed some loss in activity after about 3 hours' testing.

Anderson, D. N.↗

Preliminary results from screening tests of commercial catalysts with potential use in gas turbine combustors. II - Combustion test rig evaluation

Several commercial monolithic catalysts were tested in a combustion test rig to determine their suitability for use in a gas-turbine combustor primary zone. The catalyst test bed consisted of two to four elements of 12-centimeter diameter by 2.5-centimeter long monolith. Results are presented of the measured combustion efficiency and catalyst bed temperature history for an inlet propane-air mixture temperature of 800 K, a pressure of 300,000 newtons per square meter, inlet velocities of 10 to 25 meters per second and equivalence ratios of 0.1 to 0.3. The best catalysts tested gave combustion efficiencies of virtually 100% for reaction temperatures ranging from 1325 K at 10 meters per second to 1400 K at 25 meters per second. This performance was only possible with fresh catalysts. The catalysts tested were not specifically developed for use at these conditions and showed some loss in activity after about 3 hours' testing.

Anderson, D. N.↗

Radar systems for the water resources mission. Volume 4: Appendices E-I

The use of a scanning antenna beam for a synthetic aperture system was examined. When the resolution required was modest, the radar did not use all the time the beam was passing a given point on the ground to build a synthetic aperture, so time was available to scan the beam to other positions and build several images at different ranges. The scanning synthetic-aperture radar (SCANSAR) could achieve swathwidths of well over 100 km with modest antenna size. Design considerations for a SCANSAR for hydrologic parameter observation are presented. Because of the high sensitivity to soil moisture at angles of incidence near vertical, a 7 to 22 deg swath was considered for that application. For snow and ice monitoring, a 22 to 37 deg scan was used. Frequencies from X-band to L-band were used in the design studies, but the proposed system operated in C-band at 4.75 GHz. It achieved an azimuth resolution of about 50 meters at all angles, with a range resolution varying from 150 meters at 7 deg to 31 meters at 37 deg. The antenna required an aperture of 3 x 4.16 meters, and the average transmitter power was under 2 watts.

Moore, R. K.↗

Flight-measured lift and drag characteristics of a large, flexible, high supersonic cruise airplane

Flight measurements of lift, drag, and angle of attack were obtained for the XB-70 airplane, a large, flexible, high supersonic cruise airplane. This airplane had a length of over 57 meters, a takeoff gross mass of over 226,800 kilograms, and a design cruise speed of Mach 3 at an altitude of 21,340 meters. The performance measurements were made at Mach numbers from 0.72 to 3.07 and altitudes from approximately 7620 meters to 21,340 meters. The measurements were made to provide data for evaluating the techniques presently being used to design and predict the performance of aircraft in this category. Such performance characteristics as drag polars, lift-curve slopes, and maximum lift-to-drag ratios were derived from the flight data. The base drag of the airplane, changes in airplane drag with changes in engine power setting at transonic speeds, and the magnitude of the drag components of the propulsion system are also discussed.

Arnaiz, H. H.↗

Landsat-D thematic mapper simulation using aircraft multispectral scanner data

A simulation of imagery from the upcoming Landsat-D Thematic Mapper was accomplished by using selected channels of aircraft 24-channel multispectral scanner data. The purpose was to simulate Thematic Mapper 30-meter resolution imagery, to compare its spectral quality with the original aircraft MSS data, and to determine changes in thematic classification accuracy for the simulated imagery. The original resolution of approximately 7.5 meters IFOV and simulated resolution of 15, 30, and 60 meters were used to indicate the trend of spectral quality and classification accuracy. The study was based in a 6.5 square kilometer area of urban Los Angeles having a diversity of land use. The original imagery was reduced in resolution by two related methods: pixel matrix averaging, and matrix smoothing with a unity box filter, followed by matrix averaging. Thematic land use classification using training sites and a Bayesian maximum-likelihood algorithm was performed at three levels of standard deviation - 1.0, 2.0, and 3.0 sigma. Plots of relative standard deviation showed that for larger training sites with a normal distribution of data, as the resolution decreased, the distribution range of density values decreased. Also, the classification accuracies for three levels of standard deviation increased as resolution decreased. However, the indication is that a point of diminishing returns had been reached, and 30 meters IFOV should be the best for multispectral classification of urban scenes.

Clark, J.↗

Precision orbit computations for Starlette

The Starlette satellite, launched in February 1975 was designed to minimize the effects of nongravitational forces and to obtain the highest possible accuracy for laser range measurements. Analyses of the first four months of laser tracking data from nine stations have confirmed the stability of the orbit and the precision to which the satellite's position can be established. Initial orbit computations using the GSFC GEM - 7 gravity model produced rms fits of about 8 to 10 meters for arc lengths of 5 days. After tailoring a gravity model specifically to Starlette, the rms fits for the 5 day arcs were reduced significantly to the 1 to 2 meter level. An rms fit of 4.3 meters was obtained for a 90 day arc. Five day arcs overlapped by 2.5 days showed rms satellite position differences generally less than 2 meters. Prediction errors at the end of two months were less than 30 milliseconds.

Marsh, J. G.↗

Hot-water aquifer storage: A field test

The basic water injection cycle used in a large-scale field study of heat storage in a confined aquifer near Mobile, Alabama is described. Water was pumped from an upper semi-confined aquifer, passed through a boiler where it was heated to a temperature of about 55 C, and injected into a medium sand confined aquifer. The injection well has a 6-inch (15-cm) partially-penetrating steel screen. The top of the storage formation is about 40 meters below the surface and the formation thickness is about 21 meters. In the first cycle, after a storage period of 51 days, the injection well was pumped until the temperature of the recovered water dropped to 33 c. At that point 55,300 cubic meters of water had been withdrawn and 66 percent of the injected energy had been recovered. The recovery period for the second cycle continued until the water temperature was 27.5 C and 100,100 cubic meters of water was recovered. At the end of the cycle about 90 percent of the energy injected during the cycle had been recovered.

Parr, A. D.↗

JPL antenna technology development

Plans for evaluating, designing, fabricating, transporting and deploying cost effective and STS compatible offset wrap rib antennas up to 300 meters in diameter for mobile communications, Earth resources observation, and for the orbiting VLBI are reviewed. The JPL surface measurement system, intended for large mesh deployable antenna applications will be demonstrated and validated as part of the antenna ground based demonstration program. Results of the offset wrap rib deployable antenna technology development will include: (1) high confidence structural designs for antennas up to 100 meters in diameter; (2) high confidence estimates of functional performance and fabrication cost for a wide range of antenna sizes (up to 300 meters in diameter); (3) risk assessment for fabricating the large size antennas; and (4) 55 meter diameter flight quality hardware that can be cost effectively completed toto accommodate a flight experiment and/or application.

Freeland, R. E.↗