Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

L-TERRA [SWR-15-34]

Lidar (light detection and ranging) instruments are often used in wind energy studies in place of meteorological towers, as they can collect measurements at higher heights than met towers and are more easily moved to different parts of a site. While lidars can accurately measure mean wind speeds, they frequently measure different values of turbulence intensity (TI) than would be measured by a cup anemometer on a tower. Discrepancies in TI values are caused by several factors, including instrument noise and volume averaging. The inability of lidars to accurately measure turbulence is a significant barrier to replacing met towers with lidars in the future. There is currently no accepted standard process for quantifying and removing these errors in lidar TI measurements. The Software is an error reduction algorithm for lidar-measured turbulence. The algorithm is trained using co-located lidar and meteorological tower data. Lidar-measured parameters, such as wind speed, shear, and TI, will be used to predict the difference between the lidar- and tower-measured TI. The algorithm will be disseminated as a set of computer code that can be used by lidar users and manufacturers to correct lidar TI data in real time or in post-processing.

Newman, Jennifer↗

Suggested Modifications for Bifacial Capacity Testing: Preprint

Capacity tests such as those described in ASTM 2848 and IEC 61724-2 are widely used during the contracting and acceptance testing of PV systems. With the increasing deployment of bifacial PV modules, there is a need to develop a standardized approach to capacity test these systems. Although variability and bias error was inherently higher for the measured capacity of bifacial systems, it could be reduced to a level consistent with the monofacial reference system by appropriate incorporation of rear irradiance- either measured or modeled. Three field installations provided bifacial system capacity that was measured with a mean bias error and standard deviation within 1% over the 2-10 month observation period. Capacity test accuracy could be improved further by utilizing measured back-of-module temperature and the IEC 61724-2 test method.

14 SOLAR ENERGY↗

Suggested Modifications for Bifacial Capacity Testing

Capacity tests such as those described in ASTM 2848 and IEC 61724-2 are widely used during the contracting and acceptance testing of photovoltaic systems. With the increasing deployment of bifacial photovoltaic modules, there is a need to develop a standardized approach to capacity test these systems. Although variability and bias error were inherently higher for the measured capacity of bifacial systems, they could be reduced to a level consistent with the monofacial reference system by appropriate incorporation of rear irradiance—either measured or modeled. Three field installations provided bifacial system capacity that was measured with a mean bias error and standard deviation within 1% over the 2–10-month observation period. Capacity test accuracy could be improved further by using the measured back-of-module temperature and the IEC 61724-2 test method for well curated systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Effects of specimen preparation on the electromagnetic property measurements of solid materials with an automatic network analyzer

Effects of specimen preparation on measured values of an acrylic's electomagnetic properties at X-band microwave frequencies, TE sub 1,0 mode, utilizing an automatic network analyzer have been studied. For 1 percent or less error, a gap between the specimen edge and the 0.901-in. wall of the specimen holder was the most significant parameter. The gap had to be less than 0.002 in. The thickness variation and alignment errors in the direction parallel to the 0.901-in. wall were equally second most significant and had to be less than 1 degree. Errors in the measurement f the thickness were third most significant. They had to be less than 3 percent. The following parameters caused errors of 1 percent or less: ratios of specimen-holder thicknesses of more than 15 percent, gaps between the specimen edge and the 0.401-in. wall less than 0.045 in., position errors less than 15 percent, surface roughness, hickness variation in the direction parallel to the 0.401-in. wall less than 35 percent, and specimen alignment in the direction parallel to the 0.401-in. wall mass than 5 degrees.

Long, E. R., Jr.↗

Backus-Gilbert theory and its application to retrieval of ozone and temperature profiles

The inversion method provides a quantitative evaluation of the trade-off between vertical resolution of a retrieved profile and formal root-mean-square (rms) error due to measurement noise propagation. The problem of retrieving the top-side ozone profile from backscattered ultraviolet (BUV) measurements is considered. For measurements of the type currently being obtained with the Nimbus 4 and AE-E BUV experiments, it is found that a vertical resolution of approximately 0.75 scale height can be achieved for a formal volume mixing ratio profile error of 10%. Other examples include treatments of the retrieval of temperature profiles from measurements in the 15 micron CO2 absorption band for both the terrestrial and Martian atmospheres. Finally, the method is applied to the problem of retrieving temperature profiles of the Jovian planets from measurements in the far infrared pressure induced H2 lines to be obtained from the Mariner Jupiter/Saturn fly-by missions.

Conrath, B. J.↗

ATS-6 satellite radio beacon measurements at Ootacamund, India

ATS-6 radio beacon measurements of modulation phase and Faraday rotation made at Ootacamund, India in 1975-1976 are discussed with emphasis on the measurement and analysis errors. The modulation-phase errors are insensitive to the geomagnetic field and provide an accurate determination of the total columnar electron content. Comparison of modulation-phase measurements at different frequencies shows a minor sensitivity to the ATS-6 pitch angle. For the low geomagnetic latitude and nearly transverse propagation conditions of Ootacamund, the use of a fixed conversion coefficient gives an unreliable Faraday content. However, the Faraday rotation measurements may be used to determine the shape factor F, which provides information about the electron density height profile.

Davies, K.↗

Impact of non-Maxwellian electron velocity distribution functions on inferred plasma parameters in collective Thomson scattering

Optical collective Thomson scattering provides precise density and temperature measurements in numerous plasma-physics experiments. The accuracy of such measurements depends on the core assumption that the underlying electron distribution functions in under-dense laser-produced plasmas are Maxwellian. A statistically based, quantitative analysis of the errors in the measured electron density and temperature is presented when synthetic data calculated using a non-Maxwellian electron distribution function is fit assuming a Maxwellian electron distribution. Such analysis can lead to errors of up to 50% in temperature and 30% in density, in the specific case of super-Gaussian distributions characteristic of inverse bremsstrahlung heating. Furthermore including the proper family of non-Maxwellian electron distribution functions, as a fitting parameter, in Thomson-scattering analysis removes the model-dependent errors in the inferred parameters at a minimal cost to the statistical uncertainty.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Branching ratios, CP asymmetries and polarizations of $B\rightarrow \psi (2S) V$ decays

We analyze the non-leptonic decays B/B s →ψ(2S)V with V=(ρ,ω,K*,Φ) by employing the perturbative QCD (pQCD) factorization approach. Here the branching ratios, the CP asymmetries and the complete set of polarization observables are investigated systematically. Besides the traditional contributions from the factorizable and non-factorizable diagrams at the leading order, the next-to-leading order (NLO) vertex corrections could also provide considerable contributions. The pQCD predictions for the branching ratios of the B (s) →ψ(2S)K*,ψ(2S) decays are consistent with the measured values within errors. As for B→ψ(2S)ρ,ψ(2S)ω decays, the branching ratios can reach the order of 10 –5 and could be measured in the LHCb and Belle-II experiments. The numerical results show that the direct CP asymmetries of the considered decays are very small. Thus the observation of any large direct CP asymmetry for these decays will be a signal for new physics. The mixing-induced CP asymmetries in the neutral modes are very close to sin2β (s) , which suggests that these channels can give a cross-check on the measurement of the Cabbibo–Kobayashi–Maskawa (CKM) angle β and β s . We find that the longitudinal polarization fractions f 0 are suppressed to ~50% due to the large non-factorizable contributions. The magnitudes and phases of the two transverse amplitudes A∥ and A⊥ are roughly equal, which is an indication for the approximate light-quark helicity conservation in these decays. The overall polarization observables of B→ψ(2S)K* 0 and B s →ψ(2S)Φ channels are also in good agreement with the experimental measurements as reported by LHCb and BaBar. In conclusion, other results can also be tested by the LHCb and Belle-II experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Double Quarter Wave Crab Cavity Wire Stretching Measurement at BNL

The Double Quarter Wave (DQW) crab cavity is one out of the two crab cavities within Work Package 4 of the LHC (Large Hadron Collider) Hi-Lumi Program, and the RF design of the cavity was originally supported by the US LHC Accelerator Research Program (LARP) and later the LHC Accelerator Upgrade Program (AUP) funded by the DOE High Energy Physics Office in the Office of Science. Brookhaven National Laboratory (BNL) has delivered the successful DQW crab cavity RF design, and worked actively with all. The wire stretching measurement was completed on the prototype DQW crab cavity for operation practice and calibration of the measurement system. Four locations were defined to be on the electrical center plane of the crab cavity, and survey of the wire indicated all are on the same plane. The successful measurement validated the wire stretching system built at Brookhaven National Lab. The offset of the four wire locations to the fitted plane provided the error of the measurement.

43 PARTICLE ACCELERATORS↗

Antenna pointing subsystem conscan implementation

The software of the computer that drives the tracking antennas in the DSN was modified to improve the pointing accuracy for tracking operations at X-band frequencies. The change implemented an improved model for atmospheric refraction correction and added a software tracking option that corrects any remaining pointing errors. The software tracking option that was added measures the actual pointing error and corrects the antenna position accordingly.

Tappan, R.↗

Error analysis for relay type satellite-aided search and rescue systems

An analysis is made of the errors in the determination of the position of an emergency transmitter in a satellite-aided search and rescue system. The satellite is assumed to be at a height of 820 km in a near-circular near polar orbit. Short data spans of four minutes or less are used. The error sources considered are measurement noise, transmitter frequency drift, ionospheric effects, and error in the assumed height of the transmitter. The errors are calculated for several different transmitter positions, data rates, and data spans. The only transmitter frequency used was 406 MHz, but the result can be scaled to different frequencies.

Marini, J. W.↗

Horizontal electric fields from lightning return strokes

An experiment to measure simultaneously the wideband horizontal and vertical electric fields from lightning return strokes is described. Typical wave shapes of the measured horizontal and vertical fields are presented, and the horizontal fields are characterized. The measured horizontal fields are compared with calculated horizontal fields obtained by applying the wavetilt formula to the vertical fields. The limitations and sources of error in the measurement technique are discussed.

Thomson, E. M.↗

Comparing Experiment and Computation of Hypersonic Laminar Boundary Layers with Isolated Roughness

Streamwise velocity profile behavior in a hypersonic laminar boundary layer in the presence of an isolated roughness element is presented for an edge Mach number of 8.2. Two different roughness element types are considered: a 2-mm tall, 4-mm diameter cylinder, and a 2-mm radius hemisphere. Measurements of the streamwise velocity behavior using nitric oxide (NO) planar laser-induced fluorescence (PLIF) molecular tagging velocimetry (MTV) have been performed on a 20-degree wedge model. The top surface of this model acts as a flat-plate and is oriented at 5 degrees with respect to the freestream flow. Computations using direct numerical simulation (DNS) of these flows have been performed and are compared to the measured velocity profiles. Particular attention is given to the characteristics of velocity profiles immediately upstream and downstream of the roughness elements. In these regions, the streamwise flow can experience strong deceleration or acceleration. An analysis in which experimentally measured MTV profile displacements are compared with DNS particle displacements is performed to determine if the assumption of constant velocity over the duration of the MTV measurement is valid. This assumption is typically made when reporting MTV-measured velocity profiles, and may result in significant errors when comparing MTV measurements to computations in regions with strong deceleration or acceleration. The DNS computations with the cylindrical roughness element presented in this paper were performed with and without air injection from a rectangular slot upstream of the cylinder. This was done to determine the extent to which gas seeding in the MTV measurements perturbs the boundary layer flowfield.

Bathel, Brett F.↗

The Impact of Truth Surrogate Variance on Quality Assessment/Assurance in Wind Tunnel Testing

Minimum data volume requirements for wind tunnel testing are reviewed and shown to depend on error tolerance, response model complexity, random error variance in the measurement environment, and maximum acceptable levels of inference error risk. Distinctions are made between such related concepts as quality assurance and quality assessment in response surface modeling, as well as between precision and accuracy. Earlier research on the scaling of wind tunnel tests is extended to account for variance in the truth surrogates used at confirmation sites in the design space to validate proposed response models. A model adequacy metric is presented that represents the fraction of the design space within which model predictions can be expected to satisfy prescribed quality specifications. The impact of inference error on the assessment of response model residuals is reviewed. The number of sites where reasonably well-fitted response models actually predict inadequately is shown to be considerably less than the number of sites where residuals are out of tolerance. The significance of such inference error effects on common response model assessment strategies is examined.

DeLoach, Richard↗

High Temperature W-band Complex Permittivity Measurements of Thermally Cycled Ceramic-Metal Composites: AlN:Mo with 0.25 vol% to 4.0 vol% Mo from 25 °C to 1000 °C in Air

An apparatus for measuring the W-band (75-110GHz) complex permittivity of dielectrics at 1000 °C was developed. This apparatus allows for measurements at approximately twice the temperature of previously published high temperature free-space measurement systems while maintaining similar precision. Challenges were addressed related to high temperature measurements, including temperature uniformity, the accuracy of temperature measurements, and preventing temperature related changes to mm-wave measurement systems. The details of complex permittivity extraction from the measured S-parameters are discussed. Sources of error related to permittivity measurement and mathematical models were identified and are discussed in detail herein. Thermally-cycled, mm-wave absorbing, aluminum nitride ceramic composites containing varying levels of molybdenum additives were measured over the range of 25-1000 °C. These measurements were compared to the same composites before thermal cycling. It was found that ceramic composites are largely stable after thermal cycling in terms of dielectric properties despite the presence of visible surface modifications.

Zane W Cohick↗

Development and application of a standardized flow measurement uncertainty analysis framework to various low-head short-converging intake types across the United States federal hydropower fleet

Turbine discharges at low-head short converging intakes are difficult to measure accurately. The proximity of the measurement section to the intake entrance admits large uncertainties related to asymmetry of the velocity profile, swirl, and turbulence. Existing turbine performance codes [10, 24] do not address this special case and published literature is largely silent on rigorous evaluation of uncertainties associated with this measurement context. The American Society of Mechanical Engineers (ASME) Committee investigated the use of Acoustic transit time (ATT), Acoustic scintillation (AS), and Current meter (CM) in a short converging intake at the Kootenay Canal Generating Station in 2009. Based on their findings, a standardized uncertainty analysis (UA) framework for velocity-area method (specifically for CM measurements) is presented in this paper given the fact that CM is still the most fundamental and common type of measurement system. Typical sources of systematic and random errors associated with CM measurements are investigated, and the major sources of uncertainties associated with turbulence and velocity fluctuations, numerical velocity integration technique (bi-cubic spline), and the number and placement of current meters are being considered for an evaluation. Since the velocity measurements in a short converging intake are associated with complex nonlinear and time varying uncertainties (e.g., Reynolds stress in fluid dynamics), simply applying the law of propagation of uncertainty is known to overestimate the measurement variance while the Monte Carlo method does not. Therefore, a pseudo-Monte Carlo simulation method (random flow generation technique [8]) which was initially developed for the purpose of establishing upstream or initial conditions in the Large-Eddy Simulation (LES) and the Direct Numerical Simulation (DNS) is used to statistically determine uncertainties associated with turbulence and velocity fluctuations. This technique is then combined with a bi-cubic spline interpolation method which converts point velocities into a continuous velocity distribution over the measurement domain. Subsequently the number and placement of current meters are simulated to investigate the accuracy of the estimated flow rates using the numerical velocity-area integration method outlined in ISO 3354 [12]. The authors herein consider that statistics on generated flow rates processed with bi-cubic interpolation and sensor simulations are the combined uncertainties which already accounted for the effects of all those three uncertainty sources. A preliminary analysis based on the current meter data obtained through an upgrade acceptance test of a single unit located in a mainstem plant has been presented.

Smith, Brennan T↗

Current Status of the Development of a Transportable and Compact VLBI System by NICT and GSI

MARBLE (Multiple Antenna Radio-interferometer for Baseline Length Evaluation) is under development by NICT and GSI. The main part of MARBLE is a transportable VLBI system with a compact antenna. The aim of this system is to provide precise baseline length over about 10 km for calibrating baselines. The calibration baselines are used to check and validate surveying instruments such as GPS receiver and EDM (Electro-optical Distance Meter). It is necessary to examine the calibration baselines regularly to keep the quality of the validation. The VLBI technique can examine and evaluate the calibration baselines. On the other hand, the following roles are expected of a compact VLBI antenna in the VLBI2010 project. In order to achieve the challenging measurement precision of VLBI2010, it is well known that it is necessary to deal with the problem of thermal and gravitational deformation of the antenna. One promising approach may be connected-element interferometry between a compact antenna and a VLBI2010 antenna. By measuring repeatedly the baseline between the small stable antenna and the VLBI2010 antenna, the deformation of the primary antenna can be measured and the thermal and gravitational models of the primary antenna will be able to be constructed. We made two prototypes of a transportable and compact VLBI system from 2007 to 2009. We performed VLBI experiments using theses prototypes and got a baseline length between the two prototypes. The formal error of the measured baseline length was 2.7 mm. We expect that the baseline length error will be reduced by using a high-speed A/D sampler.

Ishii, Atsutoshi↗