Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Measurements of the Electron Cloud Density in the PEP-II Low Energy Ring

Clouds of low energy electrons in the vacuum beam pipes of accelerators of positively charged particle beams present a serious limitation for operation of these machines at high currents. Because of the size of these accelerators, it is difficult to probe the low energy electron clouds over substantial lengths of the beam pipe. We have developed a novel technique to directly measure the electron cloud density via the phase shift induced in a TE wave that is independently excited and transmitted over a section of the accelerator. We infer the absolute phase shift with relatively high accuracy from the phase modulation of the transmission due to the modulation of the electron cloud density from a gap in the positively charged beam. We have used this technique for the first time to measure the average electron cloud density over a 50 m straight section in the positron ring of the PEP-II collider at the Stanford Linear Accelerator Center. We have also measured the variation of the density by using low field solenoid magnets to control the electrons.

43 PARTICLE ACCELERATORS↗

Challenges and Opportunities for the Next Generation of Photon Regeneration Experiments

Photon regeneration experiments searching for signatures of oscillations of photons into hypothetical very weakly interacting ultra-light particles, such as axions, axion-like and hidden-sector particles, have improved their sensitivity considerably in recent years. Important progress in laser and detector technology as well as recycling of available magnets from accelerators may allow a big further step in sensitivity such that, for the first time, laser light shining through a wall experiments will explore territory in parameter space that has not been excluded yet by astrophysics and cosmology. We review these challenges and opportunities for the next generation experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Post-assembly magnetization of a 100 kW high speed permanent magnet rotor

A post-assembly magnetizing fixture has been designed and successfully used to magnetize the rotor of a 100 kW high speed permanent magnet synchronous motor. The rotor is a solid cylinder with outer diameter of 80 mm and total length of 515 mm. The permanent magnet material is samarium-cobalt (Sm{sub 2}Co{sub 17}) with saturation magnetizing field of 6 T. The mechanical stability of the magnetizing fixture has been studied as well as the general design methodology. The magnetizing coil is subdivided in order to reduce the electromagnetic force, and the coils are separately reinforced in different ways. The electromagnetic and structural optimization is performed by finite element analysis and verified by experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BIPOLAR MAGNETIC REGIONS ON THE SUN: GLOBAL ANALYSIS OF THE SOHO/MDI DATA SET

The magnetic flux that is generated by dynamo processes inside the Sun emerges in the form of bipolar magnetic regions. The properties of these directly observable signatures of the dynamo can be extracted from full-disk solar magnetograms. The most homogeneous, high-quality synoptic data set of solar magnetograms has been obtained with the Michelson Doppler Imager (MDI) instrument on the Solar and Heliospheric Observatory spacecraft during 1995-2011. We have developed an IDL program that has, when applied to the 73,838 magnetograms of the MDI data set, automatically identified 160,079 bipolar magnetic regions that span a range of scale sizes across nearly four orders of magnitude. The properties of each region have been extracted and statistically analyzed, in particular with respect to the polarity orientations of the bipolar regions, including their tilt-angle distributions and their violations of Hale's polarity law. The latitude variation of the average tilt angles (with respect to the E-W direction), which is known as Joy's law, is found to closely follow the relation 32.{sup 0}1 Multiplication-Sign sin (latitude). There is no indication of a dependence on region size that one may expect if the tilts were produced by the Coriolis force during the buoyant rise of flux loops from the tachocline region. A few percent of all regions have orientations that violate Hale's polarity law. We show explicit examples, from different phases of the solar cycle, where well-defined medium-size bipolar regions with opposite polarity orientations occur side by side in the same latitude zone in the same magnetogram. Such oppositely oriented large bipolar regions cannot be part of the same toroidal flux system, but different flux systems must coexist at any given time in the same latitude zones. These examples are incompatible with the paradigm of coherent, subsurface toroidal flux ropes as the source of sunspots, and instead show that fluctuations must play a major role at all scales for the turbulent dynamo. To confirm the profound role of fluctuations at large scales, we show explicit examples in which large bipolar regions differ from the average Joy's law orientation by an amount between 90 Degree-Sign and 100 Degree-Sign . We see no observational support for a separation of scales or a division between a global and a local dynamo, since also the smallest scales in our sample retain a non-random component that significantly contributes to the accumulated emergence of a north-south dipole moment that will lead to the replacement of the old global poloidal field with a new one that has the opposite orientation.

79 ASTRONOMY AND ASTROPHYSICS↗

Small solar wind transients: Stereo-A observations in 2009

Year 2009 was the last year of a long and pronounced solar activity minimum. In this year the solar wind in the inner heliosphere was for 90% of the time slow (< 450 km s{sup -1}) and with a weaker magnetic field strength compared to the previous solar minimum 1995-1996. We choose this year to present the results of a systematic search for small solar wind transients (STs) observed by the STEREO-Ahead (ST-A) probe. The data are from the PLASTIC and IMPACT instrument suites. By 'small' we mean a duration from {approx}1 to 12 hours. The parameters we search for to identify STs are (i) the total field strength, (ii) the rotation of the magnetic field vector, (iii) its smoothness, (iv) proton temperature, (v) proton beta, and (vi) Alfven Mach number. We find 45 examples. The STs have an average duration of {approx}4 hours. Ensemble averages of key quantities are: (i) maximum B = 7.01 nT; (ii) proton {beta}= 0.18; (iii) proton thermal speed = 20.8 km s{sup -1}; and (iv) Alfven Mach number = 6.13. No distinctive feature is found in the pitch angle distributions of suprathermal electrons. Our statistical results are compared with those of STs observed near Earth by Wind during 2009.

79 ASTRONOMY AND ASTROPHYSICS↗

The Unified Radio and Plasma wave investigation

The scientific objectives of the Ulysses Unified Radio and Plasma wave (URAP) experiment are twofold: (1) the determination of the direction, angular size, and polarization of radio sources for remote sensing of the heliosphere and the Jovian magnetosphere and (2) the detailed study of local wave phenomena, which determine the transport coefficients of the ambient plasma. A brief discussion of the scientific goals of the experiment is followed by a comprehensive description of the instrument. The URAP sensors consist of a 72.5 m electric field antenna in the spin plane, a 7.5-m electric field monopole along the spin axis of a pair of orthogonal search coil magnetic antennas. The various receivers, designed to encompass specific needs of the investigation, cover the frequency range from dc to 1 MHz. A relaxation sounder provides very accurate electron density measurements. Radio and plasma wave observations are shown to demonstrate the capabilities and limitations of the URAP instruments: radio observations include solar bursts, auroral kilometric radiation, and Jovian bursts; plasma waves include Langmuir waves, ion acousticlike noise, and whistlers.

Stone, R. G.↗

MEMS-Based Micro Instruments for In-Situ Planetary Exploration

NASA's planetary exploration strategy is primarily targeted to the detection of extant or extinct signs of life. Thus, the agency is moving towards more in-situ landed missions as evidenced by the recent, successful demonstration of twin Mars Exploration Rovers. Also, future robotic exploration platforms are expected to evolve towards sophisticated analytical laboratories composed of multi-instrument suites. MEMS technology is very attractive for in-situ planetary exploration because of the promise of a diverse and capable set of advanced, low mass and low-power devices and instruments. At JPL, we are exploiting this diversity of MEMS for the development of a new class of miniaturized instruments for planetary exploration. In particular, two examples of this approach are the development of an Electron Luminescence X-ray Spectrometer (ELXS), and a Force-Detected Nuclear Magnetic Resonance (FDNMR) Spectrometer.

micro instruments↗

Vision 20/20: Simultaneous CT-MRI — Next chapter of multimodality imaging

Multimodality imaging systems such as positron emission tomography-computed tomography (PET-CT) and MRI-PET are widely available, but a simultaneous CT-MRI instrument has not been developed. Synergies between independent modalities, e.g., CT, MRI, and PET/SPECT can be realized with image registration, but such postprocessing suffers from registration errors that can be avoided with synchronized data acquisition. The clinical potential of simultaneous CT-MRI is significant, especially in cardiovascular and oncologic applications where studies of the vulnerable plaque, response to cancer therapy, and kinetic and dynamic mechanisms of targeted agents are limited by current imaging technologies. The rationale, feasibility, and realization of simultaneous CT-MRI are described in this perspective paper. The enabling technologies include interior tomography, unique gantry designs, open magnet and RF sequences, and source and detector adaptation. Based on the experience with PET-CT, PET-MRI, and MRI-LINAC instrumentation where hardware innovation and performance optimization were instrumental to construct commercial systems, the authors provide top-level concepts for simultaneous CT-MRI to meet clinical requirements and new challenges. Simultaneous CT-MRI fills a major gap of modality coupling and represents a key step toward the so-called “omnitomography” defined as the integration of all relevant imaging modalities for systems biology and precision medicine.

60 APPLIED LIFE SCIENCES↗

Magnetoencephalography with a two-color pump probe atomic magnetometer.

The authors have detected magnetic fields from the human brain with a compact, fiber-coupled rubidium spin-exchange-relaxation-free magnetometer. Optical pumping is performed on the D1 transition and Faraday rotation is measured on the D2 transition. The beams share an optical axis, with dichroic optics preparing beam polarizations appropriately. A sensitivity of <5 fT/{radical}Hz is achieved. Evoked responses resulting from median nerve and auditory stimulation were recorded with the atomic magnetometer. Recordings were validated by comparison with those taken by a commercial magnetoencephalography system. The design is amenable to arraying sensors around the head, providing a framework for noncryogenic, whole-head magnetoencephalography.

47 OTHER INSTRUMENTATION↗

Optimization of the first order gradiometer for small sample magnetization measurements using pulse integrating magnetometer

In the paper we present an analytical calculation method for determination of the sensitivity of a pulse field magnetometer working with a first order gradiometer. Our considerations here are especially focused on a case of magnetic moment measurements of very small samples. Derived in the work analytical equations allow for a quick estimation of the magnetometer's sensitivity and give also the way to its calibration using the sample simulation coil method. On the base of the given in the paper calculations we designed and constructed a simple homemade magnetometer and performed its sensitivity calibration.

36 MATERIALS SCIENCE↗

DETECTION OF X-RAY PERIODICITY FROM A NEW ECLIPSING POLAR CANDIDATE XGPS-I J183251-100106

We report the results from a detailed analysis of an archival XMM-Newton observation of the X-ray source XGPS-I J183251-100106, which has been suggested as a promising magnetic cataclysmic variable (CV) candidate based on its optical properties. A single periodic signal of {approx}1.5 hr is detected from all EPIC instruments on board XMM-Newton. The phase-averaged X-ray spectrum can be well modeled with a thermal bremsstrahlung temperature of kT {approx} 50 keV. Both the X-ray spectral and temporal behavior of this system suggest that it is an eclipsing CV of the AM Herculis (or polar) type.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing Majorana Wave Functions in Kitaev Honeycomb Spin Liquids with Second-Order Two-Dimensional Spectroscopy

Two-dimensional coherent terahertz spectroscopy (2DCS) emerges as a valuable tool to probe the nature, couplings, and lifetimes of excitations in quantum materials. It thus promises to identify unique signatures of spin liquid states in quantum magnets by directly probing properties of their exotic fractionalized excitations. Here, in this study, we calculate the second-order 2DCS of the Kitaev honeycomb model and demonstrate that distinct spin liquid fingerprints appear already in this lowest-order nonlinear response $\chi^{(2)}_{yzx}$⁡($ω_1$, $ω_2$) when using crossed light polarizations. We further relate the off-diagonal 2DCS peaks to the localized nature of the matter Majorana excitations trapped by $\mathbb{Z}_2$ flux excitations and show that 2DCS thus directly probes the inverse participation ratio of Majorana wave functions. By providing experimentally observable features of spin liquid states in the 2D spectrum, our Letter can guide future 2DCS experiments on Kitaev magnets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test Stand Functional Requirements for Testing MQXFA Magnets and Q1/Q3 Cryostat Assemblies (Rev.3)

This document specifies test stand requirements for testing the High Luminosity LHC (HL-LHC, or HiLumi LHC) MQXFA magnets and LQXFA/B cryostat assemblies. Total of 12 (3 pre-series, 7 series production and 2 re-work) of these cryostat assemblies are expected to be fabricated and delivered to CERN by the U.S. HL-LHC Accelerator Upgrade Project (US HL-LHC AUP) as part of the U.S. contributions to the LHC High Luminosity Upgrade. These cryostat assemblies are the quadrupole magnetic components of the HL-LHC Q1 (LQXFA) and Q3 (LQXFB) inner triplet optical elements in front of the interactions points 1 (ATLAS) and 5 (CMS). One LMQXFA cold mass is installed in each cryostat assembly and each cold mass consists of two MQXFA quadrupole magnets. MQXFA, LMQXFA and LQXFA/B functional requirements are specified in [1,2,3].MQXFA magnets will be tested at BNL Vertical Magnet Test Facility (VMTF) and 12 cryostat assembly tests planned at Fermilab’s Horizontal Magnet Test Facility (HMTF). This document specifies the test stand functional requirements for testing MQXFA magnets and LQXFA/B cryostat assemblies.

43 PARTICLE ACCELERATORS↗

Electromagnetic anti-jam telemetry tool

A mud-pulse telemetry tool includes a tool housing, a motor disposed in the tool housing, and a magnetic coupling coupled to the motor and having an inner shaft and an outer shaft. The tool may also include a stator coupled to the tool housing, a restrictor disposed proximate the stator and coupled to the magnetic coupling, so that the restrictor and the stator adapted to generate selected pulses in a drilling fluid when the restrictor is selectively rotated. The tool may also include a first anti-jam magnet coupled to the too housing, and an second anti-jam magnet disposed proximate the first anti-jam magnet and coupled to the inner shaft and/or the outer shaft, wherein at least one of the first anti-jam magnet and the second anti-jam magnet is an electromagnet, and wherein the first anti-jam magnet and the second anti-jam magnet are positioned with adjacent like poles.

47 OTHER INSTRUMENTATION↗

Design and performance of a compact scanning transmission X-ray microscope at the Photon Factory

We present a new compact instrument designed for scanning transmission X-ray microscopy. It has piezo-driven linear stages, making it small and light. Optical components from the virtual source point to the detector are located on a single optical table, resulting in a portable instrument that can be operated at a general-purpose spectroscopy beamline without requiring any major reconstruction. Careful consideration has been given to solving the vibration problem common to high-resolution microscopy, so as not to affect the spatial resolution determined by the Fresnel zone plate. Results on bacteriogenic iron oxides, single particle aerosols, and rare-earth permanent magnets are presented as examples of its performance under diverse applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray and rotational luminosity correlation and magnetic heating of radio pulsars

Previous works have suggested a correlation between the X-ray luminosity L{sub x} and the rotational luminosity L{sub rot} of radio pulsars. However, none of the obtained regression lines is statistically acceptable due to large scatter. We construct a statistical model that has an intrinsic L{sub x}–L{sub rot} relation and reproduces the observed L{sub x} distribution about it by using a Monte Carlo simulator, which takes into account the effects obscuring the intrinsic relation, i.e., the anisotropy of radiation, additional heating, uncertainty in distance, and the detection limit of the instruments. From the ATNF pulsar catalog we collect 57 “ordinary radio pulsars” with significant detection and 42 with upper limits. The sample does not include high-magnetic-field pulsars (>10{sup 13} G), which are analyzed separately. We obtain a statistically acceptable relation L{sub x}(0.5--10keV)=10{sup 31.69}(L{sub rot}/L{sub 0}){sup c{sub 1}} with c {sub 1} = 1.03 ± 0.27 and L {sub 0} = 10{sup 35.38}. The distribution about the obtained L{sub x}–L{sub rot} relation is reproduced well by the simulator. Pulsars with abnormally high L{sub x} fall into two types: one is the soft gamma-ray pulsars, and the other is pulsars that are thermally bright in comparison with the standard cooling curve. On the other hand, pulsars showing low L{sub x} are found to have dim pulsar wind nebulae (PWNs). We argue that there is an unknown mechanism that governs both the magnetospheric emission and the PWNs, and it might involve the production rate of electron–positron pairs. High-field pulsars form a population that is distinct from ordinary pulsars due to their excess luminosities.

79 ASTRONOMY AND ASTROPHYSICS↗

Cygnus X-1: A Case for a Magnetic Accretion Disk?

With the advent of Rossi X-ray Timing Explorer (RXTE), which is capable of broad spectral coverage and fast timing, as well as other instruments which are increasingly being used in multi-wavelength campaigns (via both space-based and ground-based observations), we must demand more of our theoretical models. No current model mimics all facets of a system as complex as an x-ray binary. However, a modern theory should qualitatively reproduce - or at the very least not fundamentally disagree with - all of Cygnus X-l's most basic average properties: energy spectrum (viewed within a broader framework of black hole candidate spectral behavior), power spectrum (PSD), and time delays and coherence between variability in different energy bands. Below we discuss each of these basic properties in turn, and we assess the health of one of the currently popular theories: Comptonization of photons from a cold disk. We find that the data pose substantial challenges for this theory, as well as all other in currently discussed models.

Nowak, Michael A.↗

A highly stable DC power supply for precision magnetic field measurements and other purposes

A homogeneous magnetic field is essential for the {sup 3}He neutron spin filter used to polarize neutron beams and analyze neutron spins in neutron scattering. The required spatial uniformity of the magnetic field is on the order of 10{sup -4}/cm or less. To measure such uniformity, one needs a DC current source with a current stability much better than 10{sup -4}. However, laboratory DC power supplies, which are commonly used in many {sup 3}He neutron spin filters, do not have such stabilities. To attain a highly stable current with a common laboratory DC power supply for every {sup 3}He neutron spin filter, a simple feedback circuit has been developed to keep the output current stable up to 10{sup -6}. Such a highly stable current or voltage from a common laboratory DC power supply can also be used for various other research applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗