Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Structure Corrections in Modeling VLBI Delays for RDV Data

Since 1997, bimonthly S- and X-band observing sessions have been carried out employing the VLBA (Very Long Baseline Array) and as many as ten additional antennas. Maps of the extended structures have been generated for the 160 sources observed in ten of these experiments (approximately 200,000 observations) taking place during 1997 and 1998. This paper reports the results of the first massive application of such structure maps to correct the modeled VLBI (Very Long Baseline Interferometry) delay in astrometric data analysis. For high-accuracy celestial reference frame work, proper choice of a reference point within each extended source is crucial. Here the reference point is taken at the point of maximum emitted flux. Overall, the weighted delay residuals (approximately equal to 30 ps) are reduced by 8 ps in quadrature upon introducing source maps to model the structure delays of the sources. Residuals of some sources with extended or fast-varying structures improve by as much as 40 ps. Scatter of 'arc positions' about a time-linear model decreases substantially for most sources. Based on our results, it is also concluded that source structure is presently not the dominant error source in astrometric/geodetic VLBI.

Sovers, Ojars J.↗

Fault Detection and Correction for the Solar Dynamics Observatory Attitude Control System

The Solar Dynamics Observatory is an Explorer-class mission that will launch in early 2009. The spacecraft will operate in a geosynchronous orbit, sending data 24 hours a day to a devoted ground station in White Sands, New Mexico. It will carry a suite of instruments designed to observe the Sun in multiple wavelengths at unprecedented resolution. The Atmospheric Imaging Assembly includes four telescopes with focal plane CCDs that can image the full solar disk in four different visible wavelengths. The Extreme-ultraviolet Variability Experiment will collect time-correlated data on the activity of the Sun's corona. The Helioseismic and Magnetic Imager will enable study of pressure waves moving through the body of the Sun. The attitude control system on Solar Dynamics Observatory is responsible for four main phases of activity. The physical safety of the spacecraft after separation must be guaranteed. Fine attitude determination and control must be sufficient for instrument calibration maneuvers. The mission science mode requires 2-arcsecond control according to error signals provided by guide telescopes on the Atmospheric Imaging Assembly, one of the three instruments to be carried. Lastly, accurate execution of linear and angular momentum changes to the spacecraft must be provided for momentum management and orbit maintenance. In th~sp aper, single-fault tolerant fault detection and correction of the Solar Dynamics Observatory attitude control system is described. The attitude control hardware suite for the mission is catalogued, with special attention to redundancy at the hardware level. Four reaction wheels are used where any three are satisfactory. Four pairs of redundant thrusters are employed for orbit change maneuvers and momentum management. Three two-axis gyroscopes provide full redundancy for rate sensing. A digital Sun sensor and two autonomous star trackers provide two-out-of-three redundancy for fine attitude determination. The use of software to maximize chances of recovery from any hardware or software fault is detailed. A generic fault detection and correction software structure is used, allowing additions, deletions, and adjustments to fault detection and correction rules. This software structure is fed by in-line fault tests that are also able to take appropriate actions to avoid corruption of the data stream.

Starin, Scott R.↗

The MP{sub N} method: a new angular discretization method based on piecewise polynomial interfaces fluxes

In transport calculations, it is well known how S{sub N} method is extremely inefficient in problems where the particle physics is dominated by streaming. The ray-effect eventually produced by the insufficient angular discretization, appears to be extremely persistent with respect to the refinement of the angular quadrature. The MP{sub N} method, that relies on continuous angular representation, offers a robust remedy to such an issue. MP{sub N} is based on the decomposition of the unit sphere into solid angles and on a piecewise continuous definition of interface fluxes, which are expanded in polynomials in each solid angle. This allows propagating more than one angular degree of freedom simultaneously while maintaining unaltered the block-diagonal pattern of the displacement plus removal operator. The method is therefore well suited for the flux resolution by means of a conventional sweep algorithm. Furthermore, unlike the S{sub N} method, MP{sub N} does not rely on discrete directions and, thus, on an angular quadrature formula, but rather constructs a set of linear equations solving for the angular moments of the flux for all discrete solid angles within the sweep. MP{sub N} shows an error convergence rate higher than S{sub N} at the expense of an increased size of the coefficient matrices, so of the computational cost. Although MP{sub N} is not free from ray-effect, the latter is effectively mitigated and less persistent with respect to the increase of the angular refinement order. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

DEMONSTRATION OF A HYBRID INTELLIGENT CONTROL STRATEGY FOR CRITICAL BUILDING HVAC SYSTEMS

Many industrial facilities utilize pressure control gradients to prevent migration of hazardous species from containment areas to occupied zones, often using Proportional-Integral-Derivative (PID) control. Within these facilities, PID control is often inadequate to maintain desired performance due to changing operating conditions. As the goal of the Heating, Ventilation and Air-Conditioning (HVAC) control system is to optimize the pressure gradients and associated flows for the plant, Linear Quadratic Tracking (LQT) provides a time-based approach to guiding plant interactions. However, LQT methods are susceptible to modeling and measurement errors, and therefore a hybrid design using the integration of soft control methods with hard control methods is developed and demonstrated to account for these errors and nonlinearities.

47 OTHER INSTRUMENTATION↗

On unifying randomized methods for inverse problems

This work unifies the analysis of various randomized methods for solving linear and nonlinear inverse problems with Gaussian priors by framing the problem in a stochastic optimization setting. By doing so, we show that many randomized methods are variants of a sample average approximation (SAA). More importantly, we are able to prove a single theoretical result that guarantees the asymptotic convergence for a variety of randomized methods. Additionally, viewing randomized methods as an SAA enables us to prove, for the first time, a single non-asymptotic error result that holds for randomized methods under consideration. Another important consequence of our unified framework is that it allows us to discover new randomization methods. Here, we present various numerical results for linear, nonlinear, algebraic, and PDE-constrained inverse problems that verify the theoretical convergence results and provide a discussion on the apparently different convergence rates and the behavior for various randomized methods.

42 ENGINEERING↗

Response Surface Modeling Tolerance and Inference Error Risk Specifications: Proposed Industry Standards

This paper reviews the derivation of an equation for scaling response surface modeling experiments. The equation represents the smallest number of data points required to fit a linear regression polynomial so as to achieve certain specified model adequacy criteria. Specific criteria are proposed which simplify an otherwise rather complex equation, generating a practical rule of thumb for the minimum volume of data required to adequately fit a polynomial with a specified number of terms in the model. This equation and the simplified rule of thumb it produces can be applied to minimize the cost of wind tunnel testing.

DeLoach, Richard↗

Spectral Polarization Distribution Models (PDMs) for NASA CLARREO Pathfinder’s Inter-Calibration Applications

Solar radiation scattered by Earth surfaces of various scene types such as oceans, deserts, tree leaves etc and atmospheric molecules and particles is polarized and the amount of polarization depends on the surface composition and particle physical properties. This can be a source of measurement errors in satellite data if a non-polarimetric radiometric sensor is sensitive to the polarization state of light. To obtain highly accurate spectral solar radiation data from the Earth-atmosphere system for the space-borne inter-calibration studies as proposed in NASA's Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission and the CLARREO Pathfinder (CPF) mission, the spectral polarization state of the reflected solar light at the top of atmosphere (TOA) must be known with sufficient accuracy. The degree of polarization (DOP) and the angle of linear polarization (AOLP) of the light at the TOA as functions of incident and viewing geometry and scene type construct the Polarization Distribution Models (PDMs) for correction of polarization-induced error of satellite data. In this work, algorithms for modeling the spectral polarization state of reflected sunlight from various types of Earth, including oceans, deserts, vegetated land surfaces and these scene types with all kinds of clouds, are developed. By comparing the model results with the PARASOL satellite data, our numerical results demonstrate that the model can provide a reliable approach for making the spectral PDMs for wavelengths between 320 and 2300 nm for satellite inter-calibration applications as proposed in the CLARREO and the CLARREO CPF missions.

Sun, Wenbo↗

The use of zeolites to generate PET phantoms for the validation of quantification strategies in oncology

Purpose: In recent years, segmentation algorithms and activity quantification methods have been proposed for oncological {sup 18}F-fluorodeoxyglucose (FDG) PET. A full assessment of these algorithms, necessary for a clinical transfer, requires a validation on data sets provided with a reliable ground truth as to the imaged activity distribution, which must be as realistic as possible. The aim of this work is to propose a strategy to simulate lesions of uniform uptake and irregular shape in an anthropomorphic phantom, with the possibility to easily obtain a ground truth as to lesion activity and borders. Methods: Lesions were simulated with samples of clinoptilolite, a family of natural zeolites of irregular shape, able to absorb aqueous solutions of {sup 18}F-FDG, available in a wide size range, and nontoxic. Zeolites were soaked in solutions of {sup 18}F-FDG for increasing times up to 120 min and their absorptive properties were characterized as function of soaking duration, solution concentration, and zeolite dry weight. Saturated zeolites were wrapped in Parafilm, positioned inside an Alderson thorax-abdomen phantom and imaged with a PET-CT scanner. The ground truth for the activity distribution of each zeolite was obtained by segmenting high-resolution finely aligned CT images, on the basis of independently obtained volume measurements. The fine alignment between CT and PET was validated by comparing the CT-derived ground truth to a set of zeolites' PET threshold segmentations in terms of Dice index and volume error. Results: The soaking time necessary to achieve saturation increases with zeolite dry weight, with a maximum of about 90 min for the largest sample. At saturation, a linear dependence of the uptake normalized to the solution concentration on zeolite dry weight (R{sup 2}= 0.988), as well as a uniform distribution of the activity over the entire zeolite volume from PET imaging were demonstrated. These findings indicate that the {sup 18}F-FDG solution is able to saturate the zeolite pores and that the concentration does not influence the distribution uniformity of both solution and solute, at least at the trace concentrations used for zeolite activation. An additional proof of uniformity of zeolite saturation was obtained observing a correspondence between uptake and adsorbed volume of solution, corresponding to about 27.8% of zeolite volume. As to the ground truth for zeolites positioned inside the phantom, the segmentation of finely aligned CT images provided reliable borders, as demonstrated by a mean absolute volume error of 2.8% with respect to the PET threshold segmentation corresponding to the maximum Dice. Conclusions: The proposed methodology allowed obtaining an experimental phantom data set that can be used as a feasible tool to test and validate quantification and segmentation algorithms for PET in oncology. The phantom is currently under consideration for being included in a benchmark designed by AAPM TG211, which will be available to the community to evaluate PET automatic segmentation methods.

60 APPLIED LIFE SCIENCES↗

Optimizing the Performance of Radionuclide Identification Software in the Hunt for Nuclear Security Threats

The Radionuclide Analysis Kit (RNAK), my team’s most recent nuclide identification software, is entering the testing phase. A question arises: will removing rare nuclides from the software’s library improve its overall performance? An affirmative response indicates fundamental errors in the software’s framework, while a negative response confirms the effectiveness of the software’s key machine learning algorithms. After thorough testing, I found that the performance of RNAK cannot be improved with the library choice effect, thus verifying the effectiveness of RNAK’s algorithms—multiple linear regression, Bayesian network using the Viterbi algorithm, and branch and bound search.

97 MATHEMATICS AND COMPUTING↗

SU-F-T-559: High-Resolution Scintillating Fiber Array for In-Vivo Real-Time SRS and SBRT Patient QA

Purpose: A high-resolution scintillating fiber detector was built for in-vivo real-time patient specific quality assurance (QA). The detector is designed for stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS) to monitor treatment delivery and detect real-time deviations from planned dose to increase patient safety and treatment accuracy. Methods: The detector consists of two high-density scintillating fiber arrays layered to form an X-Y grid which can be attached to the accessory tray of a medical linac for SBRT and cone SRS treatment QA. Fiber arrays consist of 128 scintillating fibers embedded within a precision-machined, high-transmission polymer substrate with 0.8mm pitch. The fibers are coupled on both ends to high-sensitivity photodetectors and the output is recorded through a high-speed analog-to-digital converter to capture the linac pulse sequence as treatment delivery progresses. The detector has a software controlled 360 degree rotational system to capture angular beam projections for high-resolution beam profile reconstruction. Results: The detector was validated using SRS cone sizes from 6mm to 34mm and MLC defined field sizes from 5×5mm2 to 100×100mm2. The detector output response is linear with dose and is dose rate independent. Each field can be reconstructed accurately with a spatial resolution of 0.8mm and the current beam output is displayed every 50msec. Dosimetric errors of 1% with respect to the treatment plan can be identified and clinically significant deviations from the expected treatment can be displayed in real-time to alert the therapists. Conclusion: The high resolution detector is capable of reconstructing beam profiles in real-time with submillimeter resolution and 1% dose resolution. This system has the ability to project in-vivo both spatial and dosimetric errors during SBRT and SRS treatments when only a non-clinically significant fraction of the intended dose was delivered. The device has the potential to establish new standards for in-vivo patient specific QA.

60 APPLIED LIFE SCIENCES↗

A generalized polynomial chaos based ensemble Kalman filter with high accuracy

As one of the most adopted sequential data assimilation methods in many areas, especially those involving complex nonlinear dynamics, the ensemble Kalman filter (EnKF) has been under extensive investigation regarding its properties and efficiency. Compared to other variants of the Kalman filter (KF), EnKF is straightforward to implement, as it employs random ensembles to represent solution states. This, however, introduces sampling errors that affect the accuracy of EnKF in a negative manner. Though sampling errors can be easily reduced by using a large number of samples, in practice this is undesirable as each ensemble member is a solution of the system of state equations and can be time consuming to compute for large-scale problems. In this paper we present an efficient EnKF implementation via generalized polynomial chaos (gPC) expansion. The key ingredients of the proposed approach involve (1) solving the system of stochastic state equations via the gPC methodology to gain efficiency; and (2) sampling the gPC approximation of the stochastic solution with an arbitrarily large number of samples, at virtually no additional computational cost, to drastically reduce the sampling errors. The resulting algorithm thus achieves a high accuracy at reduced computational cost, compared to the classical implementations of EnKF. Numerical examples are provided to verify the convergence property and accuracy improvement of the new algorithm. We also prove that for linear systems with Gaussian noise, the first-order gPC Kalman filter method is equivalent to the exact Kalman filter.

97 MATHEMATICS AND COMPUTING↗

Statistical Error Analysis on White-Light Filter Ratio Experiments to Measure Electron Parameters

The Filter ratio technique to remotely measure electron temperature and speed using four color filters in visible light and a polarization camera was described in detail in four articles by Reginald et al., Solar physics, (2018, 2019a, 2019b, 2020). In these four articles we quantified the systematic error associated with using models of symmetric corona to interpret results from asymmetric corona. We also showed the criteria applied to select the bandwidths of filters, and the pros and cons of replacing the traditional linear polarizer with a polarization camera to measure pB. What started in 1990s as ground experiments conducted during total solar eclipses that lasted for a few minutes lead to a balloon borne experiment lasting eight hours in 2019 and will blossom into a space experiment on the International Space Station in 2023. Due to constraints on the bandwidths of the four filters, a successful mission requires quantification of the statistical error using Monte Carlo simulation to generate two feasibility profiles, which are unique to the design parameters of the coronagraph, to comprehend the feasibility to measure temperature and speed within the desired temporal and spatial resolutions. For the statistical error analysis, we use modeled K and F corona profiles, representative theoretical diffraction, scattering, and vignetting profiles, assumed efficiencies for lenses, mirrors, and polarizers, assumed detector properties on quantum efficiency, full well depth, dark noise, and read noise, and assumed instrument properties on aperture diameter, solid angle, and pixel resolution. We hope future white-light coronagraphs will exhibit capabilities to measure electron density, temperature, and speed.

Nelson Reginald↗

A Comparison of In-Room Computerized Tomography Options for Detection of Fiducial Markers in Prostate Cancer Radiotherapy

Purpose: To compare volumetric in-room computed tomography (CT) and kilovoltage (kV) cone-beam CT (CBCT) to planar imaging with respect to their ability to localize fiducial markers (FMs) for radiotherapy of prostate cancer. Methods and Materials: Image guidance options from two linear accelerators were compared in terms of identifying the center of gravity (COG) of FMs from the isocenter: a Siemens Primatom, where the couch is rotated 180 degrees from the treatment isocenter to the in-room CT vs. electronic portal imaging (EPI); and a Varian OBI system, where kV CBCT, EPI, and planar kV radiographs were compared. In all, 387 image pairs (CBCT = 133; CT = 254) from 18 patients were analyzed. A clinical tolerance of 3 mm was predefined as the acceptable threshold for agreement. Results: COG location on in-room CT and EPI was in agreement 96.9%, 85.8%, and 89.0% of the time in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions, respectively, vs. 99.2%, 91.7%, and 93.2% for the CBCT and EPI analysis. The CBCT vs. kV radiographs were in agreement 100% (LR), 85.4% (SI), and 88.5% (AP), and EPI vs. kV radiographs were in agreement 100% (LR), 94.6% (SI), and 91.5% (AP) of the time. Conclusion: Identification of FMs on volumetric or planar images was found to be not equivalent ({+-}3 mm) using either linear accelerator. Intrafraction prostate motion, interpretation of FM location, and spatial properties of images are contributing factors. Although in-room CT has superior image quality, the process of realigning the treatment couch to acquire a CT introduces an error, highlighting the benefits of a single isocentric system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonlinear modelling of polymer electrolyte membrane fuel cell stack using nonlinear cancellation technique

Fuel cells are promising new energy conversion devices that are friendly to the environment. A set of control systems are required in order to operate a fuel cell based power plant system optimally. For the purpose of control system design, an accurate fuel cell stack model in describing the dynamics of the real system is needed. Currently, linear model are widely used for fuel cell stack control purposes, but it has limitations in narrow operation range. While nonlinear models lead to nonlinear control implemnetation whos more complex and hard computing. In this research, nonlinear cancellation technique will be used to transform a nonlinear model into a linear form while maintaining the nonlinear characteristics. The transformation is done by replacing the input of the original model by a certain virtual input that has nonlinear relationship with the original input. Then the equality of the two models is tested by running a series of simulation. Input variation of H2, O2 and H2O as well as disturbance input I (current load) are studied by simulation. The error of comparison between the proposed model and the original nonlinear model are less than 1 %. Thus we can conclude that nonlinear cancellation technique can be used to represent fuel cell nonlinear model in a simple linear form while maintaining the nonlinear characteristics and therefore retain the wide operation range.

30 DIRECT ENERGY CONVERSION↗

Mitigating baryonic effects with a theoretical error covariance

ABSTRACT One of the primary sources of uncertainties in modelling the cosmic-shear power spectrum on small scales is the effect of baryonic physics. Accurate cosmology for stage-IV surveys requires knowledge of the matter power spectrum deep in the non-linear regime at the per cent level. Therefore, it is important to develop reliable mitigation techniques to take into account baryonic uncertainties if information from small scales is to be considered in the cosmological analysis. In this work, we develop a new mitigation method for dealing with baryonic physics for the case of the shear angular power spectrum. The method is based on an augmented covariance matrix that incorporates baryonic uncertainties informed by hydrodynamical simulations. We use the results from 13 hydrodynamical simulations and the residual errors arising from a fit to a ΛCDM model using the extended halo model code HMCode to account for baryonic physics. These residual errors are used to model a so-called theoretical error covariance matrix that is added to the original covariance matrix. In order to assess the performance of the method, we use the 2D tomographic shear from four hydrodynamical simulations that have different extremes of baryonic parameters as mock data and run a likelihood analysis comparing the residual bias on Ωm and σ8 of our method and the HMCode for an LSST-like survey. We use different modelling of the theoretical error covariance matrix to test the robustness of the method. We show that it is possible to reduce the bias in the determination of the tested cosmological parameters at the price of a modest decrease in the precision.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative capabilities of STXM to measure spatially resolved organic volume fractions of mixed organic/inorganic particles

Scanning transmission X-ray microscopy coupled with near-edge X-ray absorption and fine structure (STXM-NEXAFS) spectroscopy can be used to characterize the morphology and composition of aerosol particles. Here, two inorganic/organic systems are used to validate the calculation of organic volume fraction (OVF) and determine the level of associated error by using carbon K-edge STXM data at 278, 285.4, 288.6, and 320 eV. Using the mixture of sodium chloride and sucrose as one system and ammonium sulfate and sucrose as another, three solutions were made with 10:1, 1:1, and 1:10 mass ratios (inorganic to organic). The OVFs of the organic-rich aerosols of both systems deviated from the bulk OVF by less than 1%, while the inorganic-rich aerosols deviated by approximately 1 %. Aerosols from the equal mass mixture deviated more (about 4 %) due to thick inorganic regions exceeding the linear range of Beer's law. These calculations were performed after checking the data for poor image alignment, defocusing issues, and particles too thick to be analyzed. The potential for systematic error in the OVF calculation was also tested by assuming the incorrect composition. There is a small (about 0.5 %) OVF difference if the organic is erroneously assumed to be adipic acid rather than the known organic, sucrose. A much larger difference (up to 25 %) is seen if sodium chloride is assumed instead of ammonium sulfate. These results show that the OVF calculations are fairly insensitive to the organic while being much more sensitive to the choice of inorganic.

47 OTHER INSTRUMENTATION↗

Measures of model performance based on the log accuracy ratio

Quantitative assessment of modeling and forecasting of continuous quantities uses a variety of approaches. We review existing literature describing metrics for forecast accuracy and bias, concentrating on those based on relative errors and percentage errors. Of these accuracy metrics, the mean absolute percentage error (MAPE) is one of the most common across many fields and has been widely applied in recent space science literature and we highlight the benefits and drawbacks of MAPE and proposed alternatives. We then introduce the log accuracy ratio, and derive from it two metrics: the median symmetric accuracy; and the symmetric signed percentage bias. Robust methods for estimating the spread of a multiplicative linear model using the log accuracy ratio are also presented. The developed metrics are shown to be easy to interpret, robust, and to mitigate the key drawbacks of their more widely-used counterparts based on relative errors and percentage errors. Their use is illustrated with radiation belt electron flux modeling examples.

54 ENVIRONMENTAL SCIENCES↗

Functional Principal Component Analysis of Radio–Optical Reference Frame Tie

The Gaia optical reference frame is intrinsically undefined with respect to global orientation and spin, so it needs to be anchored in the radio-based International Celestial Reference Frame (ICRF) to provide a referenced and quasi-inertial celestial coordinate system. The link between the two fundamental frames is realized through two samples of distant extragalactic sources, mostly active galactic nuclei and quasars, but only the smaller sample of radio-loud ICRF sources with optical counterparts is available to determine the mutual orientation. The robustness of this link can be mathematically formulated in the framework of functional principal component analysis using a set of vector spherical harmonics to represent the differences in celestial positions of the common objects. The weakest eigenvectors are computed, which describe the greatest deficiency of the link. The deficient or poorly determined terms are specific vector fields on the sphere that carry the largest errors of absolute astrometry using Gaia in reference to the ICRF. This analysis provides guidelines for the future development of the ICRF maximizing the accuracy of the link over the entire celestial sphere. A measure of the robustness of a least-squares solution, which can be applied to any linear model fitting problem, is introduced to help discriminate between reference frame tie models of different degrees.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗