Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Level Set”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Modeling and simulation of transitional Rayleigh–Taylor flow with partially averaged Navier–Stokes equations

In this work, the partially averaged Navier–Stokes (PANS) equations are used to predict the variable-density Rayleigh–Taylor (RT) flow at Atwood number 0.5 and maximum Reynolds number 500. This is a prototypical problem of material mixing, featuring laminar, transitional, and turbulent flow, instabilities and coherent structures, density fluctuations, and production of turbulence kinetic energy by both shear and buoyancy mechanisms. These features pose numerous challenges to modeling and simulation, making the RT flow ideal to develop the validation space of the recently proposed PANS Besnard–Harlow–Rauenzahn-linear eddy viscosity model closure. The numerical simulations are conducted at different levels of physical resolution and test three approaches to set the parameters $f_\phi$ defining the range of physically resolved scales. The computations demonstrate the efficiency (accuracy vs cost) of the PANS model predicting the spatiotemporal development of the RT flow. Results comparable to large-eddy simulations and direct numerical simulations are obtained at significantly lower physical resolution without the limitations of the Reynolds-averaged Navier–Stokes equations in these transitional flows. The data also illustrate the importance of appropriate selection of the physical resolution and the resolved fraction of each dependent quantity $\phi$ of the turbulent closure, $f_\phi$. These two aspects determine the ability of the model to resolve the flow phenomena not amenable to modeling by the closure and, as such, the computations’ fidelity.

Navier Stokes equations↗

Transferability of data-driven, many-body models for CO 2 simulations in the vapor and liquid phases

Here, extending on the previous work by Riera et al. [J. Chem. Theory Comput. 16, 2246–2257 (2020)], we introduce a second generation family of data-driven many-body MB-nrg models for CO 2 and systematically assess how the strength and anisotropy of the CO 2 –CO 2 interactions affect the models’ ability to predict vapor, liquid, and vapor–liquid equilibrium properties. Building upon the many-body expansion formalism, we construct a series of MB-nrg models by fitting one-body and two-body reference energies calculated at the coupled cluster level of theory for large monomer and dimer training sets. Advancing from the first generation models, we employ the charge model 5 scheme to determine the atomic charges and systematically scale the two-body energies to obtain more accurate descriptions of vapor, liquid, and vapor–liquid equilibrium properties. Challenges in model construction arise due to the anisotropic nature and small magnitude of the interaction energies in CO 2 , calling for the necessity of highly accurate descriptions of the multidimensional energy landscape of liquid CO 2 . These findings emphasize the key role played by the training set quality in the development of transferable, data-driven models, which, accurately representing high-dimensional many-body effects, can enable predictive computer simulations of molecular fluids across the entire phase diagram.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ON THE MAXIMUM MASS OF STELLAR BLACK HOLES

We present the spectrum of compact object masses: neutron stars and black holes (BHs) that originate from single stars in different environments. In particular, we calculate the dependence of maximum BH mass on metallicity and on some specific wind mass loss rates (e.g., Hurley et al. and Vink et al.). Our calculations show that the highest mass BHs observed in the Galaxy M{sub bh} {approx} 15 M{sub sun} in the high metallicity environment (Z = Z{sub sun} = 0.02) can be explained with stellar models and the wind mass loss rates adopted here. To reach this result we had to set luminous blue variable mass loss rates at the level of {approx}10{sup -4} M{sub sun} yr{sup -1} and to employ metallicity-dependent Wolf-Rayet winds. With such winds, calibrated on Galactic BH mass measurements, the maximum BH mass obtained for moderate metallicity (Z = 0.3 Z{sub sun} = 0.006) is M{sub bh,max} = 30 M{sub sun}. This is a rather striking finding as the mass of the most massive known stellar BH is M{sub bh} = 23-34 M{sub sun} and, in fact, it is located in a small star-forming galaxy with moderate metallicity. We find that in the very low (globular cluster-like) metallicity environment the maximum BH mass can be as high as M{sub bh,max} = 80 M{sub sun} (Z = 0.01 Z{sub sun} = 0.0002). It is interesting to note that X-ray luminosity from Eddington-limited accretion onto an 80 M{sub sun} BH is of the order of {approx}10{sup 40} erg s{sup -1} and is comparable to luminosities of some known ultra-luminous X-ray sources. We emphasize that our results were obtained for single stars only and that binary interactions may alter these maximum BH masses (e.g., accretion from a close companion). This is strictly a proof-of-principle study which demonstrates that stellar models can naturally explain even the most massive known stellar BHs.

79 ASTRONOMY AND ASTROPHYSICS↗

VERITAS OBSERVATIONS OF THE TeV BINARY LS I +61{sup 0} 303 DURING 2008-2010

We present the results of observations of the TeV binary LS I +61{sup 0} 303 with the VERITAS telescope array between 2008 and 2010, at energies above 300 GeV. In the past, both ground-based gamma-ray telescopes VERITAS and MAGIC have reported detections of TeV emission near the apastron phases of the binary orbit. The observations presented here show no strong evidence for TeV emission during these orbital phases; however, during observations taken in late 2010, significant emission was detected from the source close to the phase of superior conjunction (much closer to periastron passage) at a 5.6 standard deviation (5.6{sigma}) post-trials significance. In total, between 2008 October and 2010 December a total exposure of 64.5 hr was accumulated with VERITAS on LS I +61{sup 0} 303, resulting in an excess at the 3.3{sigma} significance level for constant emission over the entire integrated data set. The flux upper limits derived for emission during the previously reliably active TeV phases (i.e., close to apastron) are less than 5% of the Crab Nebula flux in the same energy range. This result stands in apparent contrast to previous observations by both MAGIC and VERITAS which detected the source during these phases at 10% of the Crab Nebula flux. During the two year span of observations, a large amount of X-ray data were also accrued on LS I +61{sup 0} 303 by the Swift X-ray Telescope and the Rossi X-ray Timing Explorer Proportional Counter Array. We find no evidence for a correlation between emission in the X-ray and TeV regimes during 20 directly overlapping observations. We also comment on data obtained contemporaneously by the Fermi Large Area Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

PRECISE LABORATORY MEASUREMENTS OF TRANS-DCOOH AND TRANS-HCOOD FOR ASTROPHYSICAL OBSERVATIONS

The rotational spectra of the mono-deuterated isotopologues of trans-formic acid, trans-DCOOH and trans-HCOOD, were investigated. In the millimeter- and submillimeter-wave frequency regions the Lamb-dip technique was exploited to obtain sub-Doppler resolution and to resolve the hyperfine structure due to the deuterium and hydrogen nuclei, thus enabling the accurate determination of the corresponding hyperfine constants. The experimental determination was supported by high-level quantum-chemical calculations at the coupled-cluster level of theory using large atomic-orbital basis sets. The Lamb-dip measurements were also supplemented by THz Doppler-limited measurements in order to extend the predictive capability of the available spectroscopic parameters to higher frequencies.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision measurement of the local bias of dark matter halos

We present accurate measurements of the linear, quadratic, and cubic local bias of dark matter halos, using curved 'separate universe' N-body simulations which effectively incorporate an infinite-wavelength overdensity. This can be seen as an exact implementation of the peak-background split argument. We compare the results with the linear and quadratic bias measured from the halo-matter power spectrum and bispectrum, and find good agreement. On the other hand, the standard peak-background split applied to the Sheth and Tormen (1999) and Tinker et al. (2008) halo mass functions matches the measured linear bias parameter only at the level of 10%. The prediction from the excursion set-peaks approach performs much better, which can be attributed to the stochastic moving barrier employed in the excursion set-peaks prediction. We also provide convenient fitting formulas for the nonlinear bias parameters b{sub 2}(b{sub 1}) and b{sub 3}(b{sub 1}), which work well over a range of redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

The large scale polarization explorer (LSPE) for CMB measurements: performance forecast

The measurement of the polarization of the Cosmic Microwave Background (CMB) radiation is one of the current frontiers in cosmology. In particular, the detection of the divergence-free component of the polarization field, the B-mode component, reveals the presence of gravitational waves in the early Universe. The detection of such component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. The measurement of the polarization of the Cosmic Microwave Background (CMB) radiation is one of the current frontiers in cosmology. In particular, the detection of the primordial divergence-free component of the polarization field, the B-mode, could reveal the presence of gravitational waves in the early Universe. The detection of such a component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. We present the updated performance forecast of the Large Scale Polarization Explorer (LSPE), a program dedicated to the measurement of the CMB polarization. LSPE is composed of two instruments: LSPE-Strip, a radiometer-based telescope on the ground in Tenerife-Teide observatory, and LSPE-SWIPE (Short-Wavelength Instrument for the Polarization Explorer) a bolometer-based instrument designed to fly on a winter arctic stratospheric long-duration balloon. The program is among the few dedicated to observation of the Northern Hemisphere, while most of the international effort is focused into ground-based observation in the Southern Hemisphere. Measurements are currently scheduled in Winter 2022/23 for LSPE-SWIPE, with a flight duration up to 15 days, and in Summer 2022 with two years observations for LSPE-Strip. In this work, we describe the main features of the two instruments, identifying the most critical aspects of the design, in terms of impact on the performance forecast. We estimate the expected sensitivity of each instrument and propagate their combined observing power to the sensitivity to cosmological parameters, including the effect of scanning strategy, component separation, residual foregrounds and partial sky coverage. We also set requirements on the control of the most critical systematic effects and describe techniques to mitigate their impact. LSPE will reach a sensitivity in tensor-to-scalar ratio of σr < 0.01, set an upper limit r < 0.015 at 95% confidence level, and improve constraints on other cosmological parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

PIERCING THE GLARE: A DIRECT IMAGING SEARCH FOR PLANETS IN THE SIRIUS SYSTEM

Astrometric monitoring of the Sirius binary system over the past century has yielded several predictions for an unseen third system component, the most recent one suggesting a {approx}<50 M{sub Jup} object in a {approx}6.3 year orbit around Sirius A. Here we present two epochs of high-contrast imaging observations performed with Subaru IRCS and AO188 in the 4.05 {mu}m narrowband Br {alpha} filter. These data surpass previous observations by an order of magnitude in detectable companion mass, allowing us to probe the relevant separation range down to the planetary-mass regime (6-12 M{sub Jup} at 1'', 2-4 M{sub Jup} at 2'', and 1.6 M{sub Jup} beyond 4''). We complement these data with one epoch of M-band observations from MMT/AO Clio, which reach comparable performance. No data set reveals any companion candidates above the 5{sigma} level, allowing us to refute the existence of Sirius C as suggested by the previous astrometric analysis. Furthermore, our Br {alpha} photometry of Sirius B confirms the lack of an infrared excess beyond the white dwarf's blackbody spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

Co-designing Spectral Transformation Oracles with Hybrid Oscillator-Qubit Quantum Processors: From Algorithms to Compilation

We co-design a family of quantum eigenvalue transformation oracles that can be efficiently implemented on hybrid discrete- or continuous-variable (qubit or qumode) hardware. To illustrate the oracle’s representation-theoretic power and near-term experimental accessibility, we encode a Gaussian imaginary time-evolution spectral filter. As a result, we define a continuous linear combination of unitaries block encoding. Due to the ancillary qumode’s infinite-dimensional nature, continuous-variable qumodes constitute a powerful compilation tool for encoding continuous spectral functions without discretization errors while minimizing resource requirements. We then focus on the ubiquitous task of preparing eigenstates in quantum spin models. For completeness, we provide an end-to-end compilation which expresses high-level oracles in terms of an experimentally realizable instruction set architecture in both 1D and 2D. Finally, we examine the leading-order effects of physical errors and highlight open research directions. Our algorithms scale linearly with the spatial extent of the target system and are applicable to both near-term and large-scale quantum processors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Examination of decay heat measurements and their relevance for understanding the origin of the reactor antineutrino anomaly

Measurements of the decay energy released as a function of time following the thermal neutron induced fission of 235 U and 239,241 Pu were performed in the 1970s at Oak Ridge National Laboratory with the purpose of quantifying possible loss of coolant accident scenarios. The derivative of this decay energy with respect to time, known in technical parlance as decay heat, is mainly composed of two terms, that of the electrons produced together with antineutrinos in the $β$-minus decay of the neutron-rich fission products, and that of the $γ$ rays produced in the subsequent decay of excited nuclear levels. In this work we study if this extensive set of decay energy measurements can be used to assess the reactor antineutrino anomaly, that is, the approximately 5% deficit of electron antineutrinos produced by nuclear reactors, first deduced by Mention and collaborators in 2011, and observed by the major reactor antineutrino experiments since. Furthermore, with the assistance of nuclear databases, we are able to obtain the ratio of electron spectra under equilibrium conditions for 235 U to 239 Pu, in better agreement with the lower trend recently reported by Kopeikin and collaborators, as well as those for 235 U to 241 Pu and 241 Pu to 239 Pu, which do not agree well with those measured at the Institut Laue-Langevin in the 1980s. We conclude that a new experimental campaign is needed to measure the electron spectra utilizing a high resolution and signal-to-noise-ratio electron spectrometer and a highly precise fission normalization procedure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of J / ψ decays to e + e − e + e − and e + e − μ + μ −

Using a data sample of 4.481 × 10 8 ψ ( 3686 ) events collected with the BESIII detector, we report the first observation of the four-lepton-decays J / ψ → e + e − e + e − and J / ψ → e + e − μ + μ − utilizing the process ψ ( 3686 ) → π + π − J / ψ . The branching fractions are determined to be [ 5.48 ± 0.31 ( stat ) ± 0.45 ( syst ) ] × 10 − 5 and [ 3.53 ± 0.22 ( stat ) ± 0.13 ( syst ) ] × 10 − 5 , respectively. The results are consistent with theoretical predictions. No significant signal is observed for J / ψ → μ + μ − μ + μ − , and an upper limit on the branching fraction is set at 1.6 × 10 − 6 at the 90% confidence level. A C P asymmetry observable is constructed for the first two channels, which is measured to be ( − 0.012 ± 0.054 ± 0.010 ) and ( 0.062 ± 0.059 ± 0.006 ) , respectively. No evidence for C P violation is observed in this process. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Measurement of exclusive Υ ( 1 S ) and Υ ( 2 S ) decays into vector-pseudoscalar final states

Using samples of 102 million $Υ(1S)$ and 158 million $Υ(2S)$ events collected with the Belle detector, we study exclusive hadronic decays of these two bottomonium resonances to $K^0_sK^+ \pi^-$ and charge-conjugate (c.c.) states, $π^+π^-π^0π^0$, and $π^+π^-π^0$, and to the two-body Vector-Pseudoscalar $(K^*(892)^0\bar{K}^0+c.c.$, $K^*(892)^-K^++c.c.$, $ωπ^0$, and $ρπ$) final states. For the first time, signals are observed in the modes $Υ(1S)$ → $K^0_sK^+\pi^- + c.c.$, $π^+π^-π^0π^0$, and $Υ(2S)$→$π^+π^-π^0π^0$, and evidence is found for the modes $Υ(1S)$→$π^+π^-π^0$, $K^*(892)^0\bar{K}^0+c.c.$, and $Υ(2S)$ → $K^0_sK^+\pi^- + c.c.$ Branching fractions are measured for all the processes, while 90% confidence level upper limits on the branching fractions are also set for the modes with a statistical significance of less than $3σ$. The ratios of the branching fractions of $Υ(2S)$ and $Υ(1S)$ decays into the same final state are used to test a perturbative QCD prediction for OZI-suppressed bottomonium decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of the f 0 ( 980 ) and f 0 ( 500 ) Scalar Mesons through the Decay D s + → π + π − e + ν e

Using e + e − collision data corresponding to an integrated luminosity of 7.33 fb − 1 recorded by the BESIII detector at center-of-mass energies between 4.128 and 4.226 GeV, we present an analysis of the decay D s + → π + π − e + ν e , where the D s + is produced via the process e + e − → D s * ± D s ∓ . We observe the f 0 ( 980 ) in the π + π − system and the branching fraction of the decay D s + → f 0 ( 980 ) e + ν e with f 0 ( 980 ) → π + π − measured to be ( 1.72 ± 0.1 3 stat ± 0.1 0 syst ) × 10 − 3 , where the uncertainties are statistical and systematic, respectively. The dynamics of the D s + → f 0 ( 980 ) e + ν e decay are studied with the simple pole parametrization of the hadronic form factor and the Flatté formula describing the f 0 ( 980 ) in the differential decay rate, and the product of the form factor f + f 0 ( 0 ) and the c → s Cabibbo-Kobayashi-Maskawa matrix element | V c s | is determined for the first time to be f + f 0 ( 0 ) | V c s | = 0.504 ± 0.01 7 stat ± 0.03 5 syst . Furthermore, the decay D s + → f 0 ( 500 ) e + ν e is searched for the first time but no signal is found. The upper limit on the branching fraction of D s + → f 0 ( 500 ) e + ν e , f 0 ( 500 ) → π + π − decay is set to be 3.3 × 10 − 4 at 90% confidence level. Published by the American Physical Society 2024

Ablikim, M.↗

Random coordinate descent: A simple alternative for optimizing parameterized quantum circuits

Variational quantum algorithms rely on the optimization of parameterized quantum circuits in noisy settings. The commonly used back-propagation procedure in classical machine learning is not directly applicable in this setting due to the collapse of quantum states after measurements. Thus, gradient estimations constitute a significant overhead in a gradient-based optimization of such quantum circuits. This paper introduces a random coordinate descent algorithm as a practical and easy-to-implement alternative to the full gradient descent algorithm. This algorithm only requires one partial derivative at each iteration. Motivated by the behavior of measurement noise in the practical optimization of parameterized quantum circuits, this paper presents an optimization problem setting that is amenable to analysis. Under this setting, the random coordinate descent algorithm exhibits the same level of stochastic stability as the full gradient approach, making it as resilient to noise. The complexity of the random coordinate descent method is generally no worse than that of the gradient descent and can be much better for various quantum optimization problems with anisotropic Lipschitz constants. Theoretical analysis and extensive numerical experiments validate our findings. Published by the American Physical Society 2024

Ding, Zhiyan (ORCID:000000018863403X)↗

Demonstrating SolarPILOT’s Python API Through Heliostat Optimal Aimpoint Strategy Use Case

SolarPILOT is a software package that generates solar field layouts and characterizes the optical performance of concentrating solar power (CSP) tower systems. SolarPILOT was developed by the National Renewable Energy Laboratory (NREL) as a stand-alone desktop application but has also been incorporated into NREL’s1 System Advisor Model (SAM) in a simplified format. Prior means for user interaction with SolarPILOT have included the application’s graphical interface, the SAM routines with limited configurability, and through a built-in scripting language called “LK.” This paper presents a new, full-featured, Python-based application programmable interface (API) for SolarPILOT, which we hereafter refer to as CoPylot. CoPylot provides access to all SolarPILOT’s capabilities to generate and characterize power tower CSP systems seamlessly through Python. Supported capabilities include (i) creating and destroying a model instance with message reporting tools; (ii) accessing and setting any SolarPILOT variable including custom land boundaries for field layouts; (iii) programmatically managing receiver and heliostat objects with varied attributes for systems with multiple receiver or heliostat types; (iv) generating, assigning, and modifying solar field layouts including the ability to set individual heliostat locations, aimpoints, soiling rates, and reflectivity levels; (v) simulating solar field performance; (vi) returning detailed results describing performance of individual heliostats, the aggregate field, and receiver flux distribution; and, (vii) exporting Python-based model instances to multiple file formats. CoPylot enables Python users to perform detailed CSP tower analysis utilizing either the Hermite expansion technique (analytical) or the SolTrace ray-tracing engine. In addition to CoPylot’s functionality, Python users have access to the over 100,000 open-source libraries to develop, analyze, optimize, and visualize power tower CSP research. This enables CSP researchers to perform analysis that was previously not possible through SolarPILOT’s existing interfaces. This paper discusses the capabilities of CoPylot and presents a use case wherein we demonstrate optimal solar field aiming strategies.

41 EE - Solar Energy Technologies Office (EE-4S)↗

DQE of wireless digital detectors: Comparative performance with differing filtration schemes

Purpose: Wireless flat panel detectors are gaining increased usage in portable medical imaging. Two such detectors were evaluated and compared with a conventional flat-panel detector using the formalism of the International Electrotechnical Commission (IEC 62220-1) for measuring modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE) using two different filtration schemes.Methods: Raw images were acquired for three image receptors (DRX-1C and DRX-1, Carestream Health; Inc., Pixium 4600, Trixell) using a radiographic system with a well-characterized output (Philips Super80 CP, Philips Healthcare). Free in-air exposures were measured using a calibrated radiation meter (Unfors Mult-O-Meter Type 407, Unfors Instruments AB). Additional aluminum filtration and a new alternative combined copper-aluminum filtration were used to conform the x ray output to IEC-specified beam quality definitions RQA5 and RQA9. Using the IEC 62220-1 formalism, each detector was evaluated at X{sub N}/2, X{sub N}, and 2X{sub N}, where the normal exposure level to the detector surface (X{sub N}) was set to 8.73 μGy (1.0 mR). The prescribed edge test device was used to evaluate the MTF, while the NNPS was measured using uniform images. The DQE was then calculated from the MTF and NNPS and compared across detectors, exposures, and filtration schemes.Results: The three DR systems had largely comparable MTFs with DRX-1 demonstrating lower values above 1.0 cycles/mm. At each exposure, DRX-1C and Pixium detectors demonstrated better noise performance than that of DRX-1. Zero-frequency DQEs for DRX-1C, Pixium, and DRX-1 detectors were approximately 74%, 63%, and 38% for RQA5 and 50%, 42%, and 28% for RQA9, respectively.Conclusions: DRX-1C detector exhibited superior DQE performance compared to Pixium and DRX-1. In terms of filtration, the alternative filtration was found to provide comparable performance in terms of rank ordering of different detectors with the added convenience of being less bulky for in-the-field measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the quantitative histogram parameters of volume transfer constant [standard deviation (SD), 98th percentile, and range], rate constant (SD), blood volume fraction (mean, SD, 98th percentile, and range), and blood flow (mean, SD, median, 98th percentile, and range) for sampling intervals between 10 and 15 s. Conclusions: The proposed method of PCA filtering combined with the AIF estimation technique allows low frequency scanning for DCE-CT study to reduce patient radiation dose. The results indicate that the method is useful in pixel-by-pixel kinetic analysis of DCE-CT data for patients with cervical cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗